The structure of optimal receiver is discussed for optical sensor measuring a small displacement of probe mass. Due to nonlinear interaction of the field and the mirror, a reflected wave is in squeezed state (natural squeezing), two quadratures of which are correlated and therefore one can increase signal-to-noise ratio and overcome the SQL. A measurement procedure realizing such correlation processing of two quadratures is clarified. The required combination of quadratures can be produced via mixing of pump field reflected from the mirror with local oscillator phase modulated field in duel-detector homodyne scheme. Such measurement procedure could be useful not only for resonant bar gravitational detector but for laser longbase interferometric detectors as well.
The structure of optimal receiver is discussed for optical sensor measuring a small displacement of probe mass. Due to nonlinear interaction of the field and the mirror, a reflected wave is in squeezed state (natural squeezing), two quadratures of which are correlated and therefore one can increase signal-to-noise ratio and overcome the SQL. A measurement procedure realizing such correlation processing of two quadratures is clarified. The required combination of quadratures can be produced via mixing of pump field reflected from the mirror with local oscillator phase modulated field in duel-detector homodyne scheme. Such measurement procedure could be useful not only for resonant bar gravitational detector but for laser longbase interferometric detectors as well.
Quantum noise is one of the limiting factors in laser-interferometric gravitational-wave (GW) detectors. The application of squeezed states in these interferometers allows the reduction of quantum noise in one quadrature. Due to opto-mechanical coupling in a GW detector the squeezed quadrature needs to be rotated within the spectrum to achieve a broadband noise reduction. So far, the implementation of additional filter cavities is considered that allow for the optimal, frequency-dependent rotation of the squeezed quadrature. However, these cavities need to have low loss, a length in the order of \unit[100]{m} and must be situated in the vacuum system, making them cost-intensive. In 2017, Ma and coworkers proposed a scheme for the broadband quantum-noise reduction without the need of additional filter cavities. It was shown by Brown et al. that a similar scheme can be used to broadband-enhance interferometers with a detuned signal-recycling cavity. Here, we performed a proof-of-principle experiment of the proposal on a table-top-scale. Squeezed states were produced detuned to the carrier field of a \unit[2.5]{m}-linear cavity and read out in a bichromatic homodyne detection. The frequencies of the lower and upper local oscillator were at entangled sidebands of the squeezed field. Depending on the relations between the involved frequencies, we can address both variants of the proposal. We show, that the frequency-dependences of the resulting noise spectra fit to a theoretical model we derived from the theory used by Ma et al. With this work we set the path towards an implementation of these schemes in a GW-detector prototype, where the compatibility of the approach with a low-frequency suspended interferometer can be tested. Moreover, we used the same setup to show nonclassical interferometer enhancement at low frequencies by high-frequency squeezed states. Here, a heterodyne readout scheme was implemented to avoid limiting noises at low frequencies. The application of squeezed states centered around the local oscillator frequency yielded an improvement in signal-to-noise ratio of $\unit[3.4]{dB}\pm\unit[0.3]{dB}$. Additionally, I designed, built and characterized a compact source of squeezed vacuum-states at \unit[1064]{nm} with a footprint of just $\unit[0.8]{m^2}$. I show measurements of squeezed states from this source with a reduction of quantum noise of $\unit[10.7]{dB}\pm\unit[0.2]{dB}$ below the vacuum noise and present a noise reduction in the frequency range from \unit[70]{kHz} to \unit[65]{MHz}.
We propose an ultrasensitive displacement measurement scheme to overcome the standard quantum limit (SQL) in the unresolved sideband cavity optomechanical system with nonlinear optomechanical coupling and squeezed light injection. By introducing the optimized quantum correlation, which is enabled by suitable choices of the squeezing angle, squeezing level, power of the probe light, and measurement angle of homodyne detection, the off-resonant displacement sensitivity reaches 6 dB below the SQL in linear optomechanical coupling. In contrast, displacement sensitivities with a coherent probe plus variational readout and squeezed probe plus fixed measurement angle (phase quadrature) are 2.6 dB and 4.6 dB below the SQL, respectively. By combining linear and quadratic optomechanical coupling, we show that the displacement sensitivity can be further improved to 9.6 dB below the SQL. Our results have potential applications in gravitational-wave detectors, quantum metrology, and the search for dark matter.
The quantum noise of the light field is a fundamental noise source in interferometric gravitational wave detectors. Injected squeezed light is capable of reducing the quantum noise contribution to the detector noise floor to values that surpass the so-called Standard-Quantum-Limit (SQL). In particular, squeezed light is useful for the detection of gravitational waves at high frequencies where interferometers are typically shot-noise limited, although the SQL might not be beaten in this case. We theoretically analyze the quantum noise of the signal-recycled laser interferometric gravitational-wave detector GEO600 with additional input and output optics, namely frequency-dependent squeezing of the vacuum state of light entering the dark port and frequency-dependent homodyne detection. We focus on the frequency range between 1 kHz and 10 kHz, where, although signal recycled, the detector is still shot-noise limited. It is found that the GEO600 detector with present design parameters will benefit from frequency dependent squeezed light. Assuming a squeezing strength of -6 dB in quantum noise variance, the interferometer will become thermal noise limited up to 4 kHz without further reduction of bandwidth. At higher frequencies the linear noise spectral density of GEO600 will still be dominated by shot-noise and improved by a factor of 10^{6dB/20dB}~2 according to the squeezing strength assumed. The interferometer might reach a strain sensitivity of 6x10^{-23} above 1 kHz (tunable) with a bandwidth of around 350 Hz. We propose a scheme to implement the desired frequency dependent squeezing by introducing an additional optical component to GEO600s signal-recycling cavity.
We suggest an interferometric scheme assisted by squeezing and linear feedback to realize the whole class of field-quadrature quantum nondemolition measurements, from Von Neumann projective measurement to a fully nondestructive noninformative one. In our setup, the signal under investigation is mixed with a squeezed probe in an interferometer and, at the output, one of the two modes is revealed through homodyne detection. The second beam is then amplitude-modulated according to the outcome of the measurement, and finally squeezed according to the transmittivity of the interferometer. Using strongly squeezed or antisqueezed probes respectively, one achieves either a projective measurement, i.e., homodyne statistics arbitrarily close to the intrinsic quadrature distribution of the signal, and conditional outputs approaching the corresponding eigenstates, or a fully nondestructive one, characterized by an almost uniform homodyne statistics, and by an output state arbitrarily close to the input signal. By varying the squeezing between these two extremes, or simply by tuning the internal phase shift of the interferometer, the whole set of intermediate cases may also be obtained. In particular, an optimal quantum nondemolition measurement of quadrature may be achieved, which minimizes the information gain versus state disturbance tradeoff.
ABSTRACT The possibility of sensitivity improvement for parametric transducers with two-component pump by new algorithm of data processing is discussed. Keywords : Quantum noises , parametric systems , quantum non-demolation measurement , optimal filtration of vector signals 1. INTRODUCTION A measurement of a weak classical force acting on a high quality mechanical system plays an important role infundamental physical experiments with probe bodies (for example, in detection of cosmic gravitational waves). Anelaboration of a low noise sensitive element which is able to record a weak displacement of mechanical system is espessially essential in these experiments. The most perspective variant of such transducers is an optical Fabry-Perot interferometer in which one mirror is rigidly connected to a mass of a mechanical oscillator.A maximal sensitivity of a parametric transducer based on modulation of a reactive parameter of an electrical(optical) system is defined in non-regenerative regime by the standard quantum limit'
Squeezed states of light are an important tool for optical measurements below the shot noise limit and for optical realizations of quantum information systems. Recently, squeezed vacuum states were deployed to enhance the shot noise limited performance of gravitational wave detectors. In most practical implementations of squeezing enhancement, relative fluctuations between the squeezed quadrature angle and the measured quadrature (sometimes called squeezing angle jitter or phase noise) are one limit to the noise reduction that can be achieved. We present calculations of several effects that lead to quadrature fluctuations, and use these estimates to account for the observed quadrature fluctuations in a LIGO gravitational wave detector. We discuss the implications of this work for quantum enhanced advanced detectors and even more sensitive third generation detectors.