Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:gr-qc/0401119 · Classical and Quantum Gravity

Squeezed light for the interferometric detection of high-frequency gravitational waves

Roman Schnabel, J. Harms, K. A. Strain, K. Danzmann

Published Feb 12, 2004• 26 citations
arXivHTMLPDF

Abstract

The quantum noise of the light field is a fundamental noise source in interferometric gravitational wave detectors. Injected squeezed light is capable of reducing the quantum noise contribution to the detector noise floor to values that surpass the so-called Standard-Quantum-Limit (SQL). In particular, squeezed light is useful for the detection of gravitational waves at high frequencies where interferometers are typically shot-noise limited, although the SQL might not be beaten in this case. We theoretically analyze the quantum noise of the signal-recycled laser interferometric gravitational-wave detector GEO600 with additional input and output optics, namely frequency-dependent squeezing of the vacuum state of light entering the dark port and frequency-dependent homodyne detection. We focus on the frequency range between 1 kHz and 10 kHz, where, although signal recycled, the detector is still shot-noise limited. It is found that the GEO600 detector with present design parameters will benefit from frequency dependent squeezed light. Assuming a squeezing strength of -6 dB in quantum noise variance, the interferometer will become thermal noise limited up to 4 kHz without further reduction of bandwidth. At higher frequencies the linear noise spectral density of GEO600 will still be dominated by shot-noise and improved by a factor of 10^{6dB/20dB}~2 according to the squeezing strength assumed. The interferometer might reach a strain sensitivity of 6x10^{-23} above 1 kHz (tunable) with a bandwidth of around 350 Hz. We propose a scheme to implement the desired frequency dependent squeezing by introducing an additional optical component to GEO600s signal-recycling cavity.

DOI
10.1088/0264-9381/21/5/099

Related papers

Quantum enhancement of a 4km laser interferometer gravitational-wave detector

S. Chua

The ability to directly detect gravitational waves will open a completely new branch of astronomy to view the Universe, one that is inaccessible to electromagnetic-based astronomy. First generation ground-based interferometric gravitational-wave detectors have achieved strain sensitivities of order one part in ten to the twenty-one, at 100 Hz detection frequency. A new generation of detectors are under construction, designed to improve on the sensitivity of the first-generation detectors by a factor of 10. The quantum nature of light will broadly limit the sensitivity of these new instruments. This quantum noise will originate from the quantum vacuum fluctuations that enter the unused port of the interferometer. One of the most promising options for reducing the quantum noise impact and further increasing the sensitivity is applying quantum squeezed vacuum states. These squeezed states have lower noise in one quadrature than the vacuum state. By replacing the quantum vacuum fluctuations entering the interferometer with squeezed vacuum states, the quantum noise impact is reduced. This thesis firstly details the development of a squeezed light source that produces squeezed states applicable for enhancing interferometric gravitational-wave detectors. A doubly-resonant, travelling-wave bow-tie cavity squeezed light source is presented. For the first time, greater than 10 dB of quantum noise suppression across the gravitational-wave detection band is directly observed, and 11.6 dB of quantum noise suppression is observed above 200 Hz. This squeezing cavity design also has benefits with intrinsic isolation to backscattered light. Experiments that quantify this isolation are reported. The properties affecting squeezing magnitude and low-frequency squeezing measurement are discussed. In addition, a modified squeezing-ellipse-phase control technique for squeezed vacuum states is presented. This thesis secondly presents results from the LIGO Squeezed Light Injection Experiment, undertaken to test squeezed light injection into a 4 km interferometric gravitational-wave detector. The results of the experiment show the first measurement of squeezing-enhancement in a 4 km gravitational-wave detector, with 2.15 dB measured above 250 Hz. This represents the best sensitivity to gravitational waves yet achieved at these frequencies by any single gravitational-wave detector to date. An unknown area was whether the addition of a squeezer would introduce noise couplings that degrade the crucial low frequency sensitivity. The results demonstrate that injected squeezed states are compatible with low frequency gravitational-wave measurement. The characterisation of squeezing-injection optical losses and fluctuations of the squeezing angle are also reported. The knowledge and processes gained, from both the squeezed light source development work and the LIGO Squeezed Light Injection Experiment, will inform the design, planning and implementation of squeezed states in future gravitational-wave detectors.

•Jan 1, 2013•1 citation

Beyond the quantum limit : a squeezed-light laser in GEO 600

Khalaidovski, Aleksandr

Albert Einstein's General Theory of Relativity predicts the existence of ripples in space- time, the so-called gravitational waves (GWs). In the past two decades, an international array of ground-based, kilometer-scale Michelson interferometers has been set up aiming at a rst observation. These Earth-bound GW detectors target signals at audio frequen- cies in a band of ca. 10 Hz { 10 kHz. At Fourier frequencies above 1 kHz, their sensitivity is limited by quantum noise. This shot-noise arises from the zero-point uctuations of the electromagnetic eld, the so-called vacuum uctuations , which enter the interferometer through its anti-symmetric signal port. Future generations of GW observatories will even be limited by quantum noise almost over their entire detection band [ ET ]. A `classical' solution to further improve the signal-to-shot-noise ratio (SNR) of the observatories consists in an increase of the circulating light power. A higher optical load inside the interferometer will, however, lead to thermally-induced beam distortion as well as to an increased radiation pressure noise level. This will eectively result in an upper limit for the optical light power employable in future GW observatory generations. An alternative approach to improve the SNR is based on the injection of so-called squeezed states of light. Such a light eld has a characteristic non-classical noise distribution in the eld quadratures. Injected from the signal port, the squeezed state replaces the vacuum state, thereby reducing the interferometer's quantum noise. The rst part of this thesis discusses the setup of a squeezed-light laser for the German- British GW observatory GEO 600. During characterization of the device, a noise reduc- tion of up to 9.6 dB below the vacuum noise level was observed in the frequency band of 10 Hz {10 kHz, setting a new benchmark for squeezing observed at audio frequencies. Corrected for detection losses, this value furthermore corresponds to more than 11 dB of squeezing available for injection into the dark port of GEO 600. Situated on a 1 : 15 m 1 : 35 m optical breadboard, the device features transportability and can be operated independently of the GW interferometer. A key feature of the squeezed-light laser is its unprecedented long-term stability. The longest characterization measurements lasted for 20 h with an overall duty cycle of more than 99 %. In the second part of this thesis, the implementation of squeezed light into GEO 600 is presented along with the results achieved. The observatory shot noise was reduced by up to 3.4 dB, corresponding to an improvement in sensitivity by a factor of up to 1.5. For isotropically distributed GW sources, this corresponds to an increase in detection probability by 1.5 3 3.4. This makes GEO 600 the rst large-scale GW interferometer with a non-classically enhanced sensitivity. Based on the performance of the squeezed- light laser, a sensitivity improvement by a factor of two, corresponding to an equivalent optical power increase by a factor of four, seems feasible in the near future.

•Jan 1, 2011•9 citations

Generation and detection of low-frequency squeezing for gravitational-wave detection

Michael Stefszky

Gravitational-wave astronomy promises a radically new method of investigating the universe, one that does not detect elementary particles, but rather ripples in space-time itself. One might expect that with this radically new method, our understanding of the universe will make an equally giant leap. One of the most promising methods for the eventual detection of gravitational-waves is that of interferometric gravitational-wave detection. The sensitivity of these devices is nothing short of amazing, and their sensitivity continues to improve. The next generation of detectors are expected reach a point where increasing the laser power, previously used to increase the sensitivity, is no longer expected to provide any benefit. One of the most promising options for further increasing the sensitivity, through reduction of the quantum noise, is via the application of "squeezed states of light". Squeezed states of light are light fields for which the noise of some observable has been reduced below the quantum noise limit. These states have been shown for many years to offer increased sensitivity in interferometers and recently in interferometric gravitational-wave detectors. One of the most challenging tasks to make suitable squeezed light sources for these detectors is to produce low-frequency squeezing, corresponding to the detection band of these interferometers. This thesis details the doubly resonant travelling wave bow-tie squeezer as a source of squeezing for interferometric gravitational-wave detection. This squeezer achieves record results of squeezing in the gravitational-wave detection band. For the first time, 10 dB of shot noise suppression at 10Hz is directly observed and above 200Hz, 11.6 dB is observed. The work presented in this thesis provides evidence that further substantiates previous progress indicating that squeezed states of light are now ready for full-time integration into interferometric gravitational-wave detectors. The new cavity design, described in detail throughout this thesis, is shown to outperform previous designs and provide benefits when integrating squeezing into these detectors, in particular, isolation to backscattered light from the interferometer. The noise sources that typically lead to degradation in squeezing measurements are investigated and discussed. Additionally, a modification to the standard locking technique used to control these vacuum squeezed states, coherent locking, is presented and discussed. The modified technique reduces the required number of locking loops and provides a larger beat note from which to derive an error signal for one of the remaining loops. A squeezer using these design philosophies is then constructed and used to inject squeezing into the LIGO gravitational-wave detector. Injection of the squeezed state provides enhancement of the sensitivity of the detector at frequencies around 200Hz and above. The sensitivity seen was equivalent to approximately 2 dB of shot noise reduction. The enhancement is limited by the loss within the interferometer. Injection of the squeezed state did not show any degradation in the sensitivity of the device below 200Hz, indicating for the first time that noise couplings between the interferometer and the squeezer could be sufficiently suppressed at these frequencies even for the most sensitive detectors.

•Jan 1, 2012•1 citation

Gravitational-wave detection beyond the quantum shot-noise limit : the integration of squeezed light in GEO 600

Emil Schreiber

The first detections of gravitational waves have opened an exciting new field of astronomy. One of the most fundamental limitations for the sensitivity of current and future interferometric gravitational-wave detectors is imposed by the quantum nature of light: Quantum vacuum fluctuations entering the interferometer through the readout port will contribute to the detection noise, at high frequencies in the form of shot noise and at low frequencies by radiation pressure noise. A promising way to reduce this quantum noise is the injection of squeezed states of light that have a lower uncertainty in one quadrature than the vacuum state. The GEO 600 gravitational-wave detector demonstrated the use of squeezed light in 2010 and it is now the first detector to routinely apply squeezing to improve its sensitivity beyond the limits set by classical quantum shot noise. This thesis details the practical aspects of long-term stable and efficient squeezed-light integration in a large-scale gravitational-wave detector. Imperfections that can limit the amount of observable non-classical noise improvement, such as optical losses and phase fluctuations, were studied in detail and methods for their mitigation were developed. Novel control schemes for the active stabilisation of the squeezed light field's phase and alignment were one main focus of the investigations. At the same time, important experience was gathered in the operation of the squeezed light source over long timescales. Over the course of the thesis work, improvements were implemented that significantly increased the performance of the squeezed-light application. Squeezing was injected with an overall duty cycle of 88%, reaching a noise reduction of up to 4.4 dB, corresponding to a 40% lowered shot-noise level. This work has firmly established the practical application of squeezing as a mature technology. The gained knowledge will directly inform the implementation of squeezed light for all future gravitational-wave detectors.

•Jan 1, 2018•1 citation

Advanced techniques for squeezed-light-enhanced gravitational-wave detection

J. Gniesmer

Quantum noise is one of the limiting factors in laser-interferometric gravitational-wave (GW) detectors. The application of squeezed states in these interferometers allows the reduction of quantum noise in one quadrature. Due to opto-mechanical coupling in a GW detector the squeezed quadrature needs to be rotated within the spectrum to achieve a broadband noise reduction. So far, the implementation of additional filter cavities is considered that allow for the optimal, frequency-dependent rotation of the squeezed quadrature. However, these cavities need to have low loss, a length in the order of \unit[100]{m} and must be situated in the vacuum system, making them cost-intensive. In 2017, Ma and coworkers proposed a scheme for the broadband quantum-noise reduction without the need of additional filter cavities. It was shown by Brown et al. that a similar scheme can be used to broadband-enhance interferometers with a detuned signal-recycling cavity. Here, we performed a proof-of-principle experiment of the proposal on a table-top-scale. Squeezed states were produced detuned to the carrier field of a \unit[2.5]{m}-linear cavity and read out in a bichromatic homodyne detection. The frequencies of the lower and upper local oscillator were at entangled sidebands of the squeezed field. Depending on the relations between the involved frequencies, we can address both variants of the proposal. We show, that the frequency-dependences of the resulting noise spectra fit to a theoretical model we derived from the theory used by Ma et al. With this work we set the path towards an implementation of these schemes in a GW-detector prototype, where the compatibility of the approach with a low-frequency suspended interferometer can be tested. Moreover, we used the same setup to show nonclassical interferometer enhancement at low frequencies by high-frequency squeezed states. Here, a heterodyne readout scheme was implemented to avoid limiting noises at low frequencies. The application of squeezed states centered around the local oscillator frequency yielded an improvement in signal-to-noise ratio of $\unit[3.4]{dB}\pm\unit[0.3]{dB}$. Additionally, I designed, built and characterized a compact source of squeezed vacuum-states at \unit[1064]{nm} with a footprint of just $\unit[0.8]{m^2}$. I show measurements of squeezed states from this source with a reduction of quantum noise of $\unit[10.7]{dB}\pm\unit[0.2]{dB}$ below the vacuum noise and present a noise reduction in the frequency range from \unit[70]{kHz} to \unit[65]{MHz}.

•Jan 1, 2019•0 citations

Squeezed light for gravitational wave astronomy

H. Vahlbruch

During the recent years an international network of interferometric gravitational wave (GW) detectors has been commissioned and searches for various classes of GWsignals are ongoing.Although the observatories are beginning to reach astrophysically interesting sensitivity levels, extensive upgrades are aimed for the next decade bringing us into the era of gravitational wave astronomy.One approach to enhance the detector sensitivity is the injection of squeezed vacuum states of light replacing the vacuum fluctuations entering the detector through its antisymmetric port.In this thesis the unprecedented generation of squeezed vacuum states with a noise power 6.5 dB below vacuum noise within the entire detection bandwidth of ground-based GW-detectors (10 Hz -10 kHz) was experimentally demonstrated at a wavelength of 1064 nm.For the first time a coherent control scheme was employed for comprehensive phase control of the experimental setup.This scheme is directly applicable to future GW-detector topologies.In addition, parasitic interference induced by scattered light was found to be a dominant noise source degrading squeezed states in the audio band.The compatibility of squeezed field injection into a detuned operated dual-recycled Michelson interferometer was demonstrated in a table top experiment.A detected non-classical sensitivity improvement of up to 3.0 dB within the entire detection bandwidth (5 -15 MHz) was accomplished by optimal preparation of the injected squeezing by means of a detuned locked filter cavity.In a further experiment strongly squeezed vacuum states were generated in the MHz-regime.With a maximum measured quantum noise reduction of 11.5 dB below the shot noise limit a new benchmark was set.This was achieved by suppression of phase noise and a remarkable reduction of optical loss in the experimental setup.Based on the squeezed light sources developed in this thesis and the experimental results achieved, a conceptual design of a compact squeezed light source was devised, allowing for a high duty cycle sensitivity improvement of GW-detectors.

•Jan 1, 2008•12 citations
The quantum noise of the light field is a fundamental noise source in interferometric gravitational wave detectors. Injected squeezed light is capable of reducing the quantum noise contribution to the detector noise floor to values that surpass the so-called Standard-Quantum-Limit (SQL). In particular, squeezed light is useful for the detection of gravitational waves at high frequencies where interferometers are typically shot-noise limited, although the SQL might not be beaten in this case. We theoretically analyze the quantum noise of the signal-recycled laser interferometric gravitational-wave detector GEO600 with additional input and output optics, namely frequency-dependent squeezing of the vacuum state of light entering the dark port and frequency-dependent homodyne detection. We focus on the frequency range between 1 kHz and 10 kHz, where, although signal recycled, the detector is still shot-noise limited. It is found that the GEO600 detector with present design parameters will benefit from frequency dependent squeezed light. Assuming a squeezing strength of -6 dB in quantum noise variance, the interferometer will become thermal noise limited up to 4 kHz without further reduction of bandwidth. At higher frequencies the linear noise spectral density of GEO600 will still be dominated by shot-noise and improved by a factor of 10^{6dB/20dB}~2 according to the squeezing strength assumed. The interferometer might reach a strain sensitivity of 6x10^{-23} above 1 kHz (tunable) with a bandwidth of around 350 Hz. We propose a scheme to implement the desired frequency dependent squeezing by introducing an additional optical component to GEO600s signal-recycling cavity.
The ability to directly detect gravitational waves will open a completely new branch of astronomy to view the Universe, one that is inaccessible to electromagnetic-based astronomy. First generation ground-based interferometric gravitational-wave detectors have achieved strain sensitivities of order one part in ten to the twenty-one, at 100 Hz detection frequency. A new generation of detectors are under construction, designed to improve on the sensitivity of the first-generation detectors by a factor of 10. The quantum nature of light will broadly limit the sensitivity of these new instruments. This quantum noise will originate from the quantum vacuum fluctuations that enter the unused port of the interferometer. One of the most promising options for reducing the quantum noise impact and further increasing the sensitivity is applying quantum squeezed vacuum states. These squeezed states have lower noise in one quadrature than the vacuum state. By replacing the quantum vacuum fluctuations entering the interferometer with squeezed vacuum states, the quantum noise impact is reduced. This thesis firstly details the development of a squeezed light source that produces squeezed states applicable for enhancing interferometric gravitational-wave detectors. A doubly-resonant, travelling-wave bow-tie cavity squeezed light source is presented. For the first time, greater than 10 dB of quantum noise suppression across the gravitational-wave detection band is directly observed, and 11.6 dB of quantum noise suppression is observed above 200 Hz. This squeezing cavity design also has benefits with intrinsic isolation to backscattered light. Experiments that quantify this isolation are reported. The properties affecting squeezing magnitude and low-frequency squeezing measurement are discussed. In addition, a modified squeezing-ellipse-phase control technique for squeezed vacuum states is presented. This thesis secondly presents results from the LIGO Squeezed Light Injection Experiment, undertaken to test squeezed light injection into a 4 km interferometric gravitational-wave detector. The results of the experiment show the first measurement of squeezing-enhancement in a 4 km gravitational-wave detector, with 2.15 dB measured above 250 Hz. This represents the best sensitivity to gravitational waves yet achieved at these frequencies by any single gravitational-wave detector to date. An unknown area was whether the addition of a squeezer would introduce noise couplings that degrade the crucial low frequency sensitivity. The results demonstrate that injected squeezed states are compatible with low frequency gravitational-wave measurement. The characterisation of squeezing-injection optical losses and fluctuations of the squeezing angle are also reported. The knowledge and processes gained, from both the squeezed light source development work and the LIGO Squeezed Light Injection Experiment, will inform the design, planning and implementation of squeezed states in future gravitational-wave detectors.
Albert Einstein's General Theory of Relativity predicts the existence of ripples in space- time, the so-called gravitational waves (GWs). In the past two decades, an international array of ground-based, kilometer-scale Michelson interferometers has been set up aiming at a rst observation. These Earth-bound GW detectors target signals at audio frequen- cies in a band of ca. 10 Hz { 10 kHz. At Fourier frequencies above 1 kHz, their sensitivity is limited by quantum noise. This shot-noise arises from the zero-point uctuations of the electromagnetic eld, the so-called vacuum uctuations , which enter the interferometer through its anti-symmetric signal port. Future generations of GW observatories will even be limited by quantum noise almost over their entire detection band [ ET ]. A `classical' solution to further improve the signal-to-shot-noise ratio (SNR) of the observatories consists in an increase of the circulating light power. A higher optical load inside the interferometer will, however, lead to thermally-induced beam distortion as well as to an increased radiation pressure noise level. This will eectively result in an upper limit for the optical light power employable in future GW observatory generations. An alternative approach to improve the SNR is based on the injection of so-called squeezed states of light. Such a light eld has a characteristic non-classical noise distribution in the eld quadratures. Injected from the signal port, the squeezed state replaces the vacuum state, thereby reducing the interferometer's quantum noise. The rst part of this thesis discusses the setup of a squeezed-light laser for the German- British GW observatory GEO 600. During characterization of the device, a noise reduc- tion of up to 9.6 dB below the vacuum noise level was observed in the frequency band of 10 Hz {10 kHz, setting a new benchmark for squeezing observed at audio frequencies. Corrected for detection losses, this value furthermore corresponds to more than 11 dB of squeezing available for injection into the dark port of GEO 600. Situated on a 1 : 15 m 1 : 35 m optical breadboard, the device features transportability and can be operated independently of the GW interferometer. A key feature of the squeezed-light laser is its unprecedented long-term stability. The longest characterization measurements lasted for 20 h with an overall duty cycle of more than 99 %. In the second part of this thesis, the implementation of squeezed light into GEO 600 is presented along with the results achieved. The observatory shot noise was reduced by up to 3.4 dB, corresponding to an improvement in sensitivity by a factor of up to 1.5. For isotropically distributed GW sources, this corresponds to an increase in detection probability by 1.5 3 3.4. This makes GEO 600 the rst large-scale GW interferometer with a non-classically enhanced sensitivity. Based on the performance of the squeezed- light laser, a sensitivity improvement by a factor of two, corresponding to an equivalent optical power increase by a factor of four, seems feasible in the near future.
Gravitational-wave astronomy promises a radically new method of investigating the universe, one that does not detect elementary particles, but rather ripples in space-time itself. One might expect that with this radically new method, our understanding of the universe will make an equally giant leap. One of the most promising methods for the eventual detection of gravitational-waves is that of interferometric gravitational-wave detection. The sensitivity of these devices is nothing short of amazing, and their sensitivity continues to improve. The next generation of detectors are expected reach a point where increasing the laser power, previously used to increase the sensitivity, is no longer expected to provide any benefit. One of the most promising options for further increasing the sensitivity, through reduction of the quantum noise, is via the application of "squeezed states of light". Squeezed states of light are light fields for which the noise of some observable has been reduced below the quantum noise limit. These states have been shown for many years to offer increased sensitivity in interferometers and recently in interferometric gravitational-wave detectors. One of the most challenging tasks to make suitable squeezed light sources for these detectors is to produce low-frequency squeezing, corresponding to the detection band of these interferometers. This thesis details the doubly resonant travelling wave bow-tie squeezer as a source of squeezing for interferometric gravitational-wave detection. This squeezer achieves record results of squeezing in the gravitational-wave detection band. For the first time, 10 dB of shot noise suppression at 10Hz is directly observed and above 200Hz, 11.6 dB is observed. The work presented in this thesis provides evidence that further substantiates previous progress indicating that squeezed states of light are now ready for full-time integration into interferometric gravitational-wave detectors. The new cavity design, described in detail throughout this thesis, is shown to outperform previous designs and provide benefits when integrating squeezing into these detectors, in particular, isolation to backscattered light from the interferometer. The noise sources that typically lead to degradation in squeezing measurements are investigated and discussed. Additionally, a modification to the standard locking technique used to control these vacuum squeezed states, coherent locking, is presented and discussed. The modified technique reduces the required number of locking loops and provides a larger beat note from which to derive an error signal for one of the remaining loops. A squeezer using these design philosophies is then constructed and used to inject squeezing into the LIGO gravitational-wave detector. Injection of the squeezed state provides enhancement of the sensitivity of the detector at frequencies around 200Hz and above. The sensitivity seen was equivalent to approximately 2 dB of shot noise reduction. The enhancement is limited by the loss within the interferometer. Injection of the squeezed state did not show any degradation in the sensitivity of the device below 200Hz, indicating for the first time that noise couplings between the interferometer and the squeezer could be sufficiently suppressed at these frequencies even for the most sensitive detectors.
The first detections of gravitational waves have opened an exciting new field of astronomy. One of the most fundamental limitations for the sensitivity of current and future interferometric gravitational-wave detectors is imposed by the quantum nature of light: Quantum vacuum fluctuations entering the interferometer through the readout port will contribute to the detection noise, at high frequencies in the form of shot noise and at low frequencies by radiation pressure noise. A promising way to reduce this quantum noise is the injection of squeezed states of light that have a lower uncertainty in one quadrature than the vacuum state. The GEO 600 gravitational-wave detector demonstrated the use of squeezed light in 2010 and it is now the first detector to routinely apply squeezing to improve its sensitivity beyond the limits set by classical quantum shot noise. This thesis details the practical aspects of long-term stable and efficient squeezed-light integration in a large-scale gravitational-wave detector. Imperfections that can limit the amount of observable non-classical noise improvement, such as optical losses and phase fluctuations, were studied in detail and methods for their mitigation were developed. Novel control schemes for the active stabilisation of the squeezed light field's phase and alignment were one main focus of the investigations. At the same time, important experience was gathered in the operation of the squeezed light source over long timescales. Over the course of the thesis work, improvements were implemented that significantly increased the performance of the squeezed-light application. Squeezing was injected with an overall duty cycle of 88%, reaching a noise reduction of up to 4.4 dB, corresponding to a 40% lowered shot-noise level. This work has firmly established the practical application of squeezing as a mature technology. The gained knowledge will directly inform the implementation of squeezed light for all future gravitational-wave detectors.
Quantum noise is one of the limiting factors in laser-interferometric gravitational-wave (GW) detectors. The application of squeezed states in these interferometers allows the reduction of quantum noise in one quadrature. Due to opto-mechanical coupling in a GW detector the squeezed quadrature needs to be rotated within the spectrum to achieve a broadband noise reduction. So far, the implementation of additional filter cavities is considered that allow for the optimal, frequency-dependent rotation of the squeezed quadrature. However, these cavities need to have low loss, a length in the order of \unit[100]{m} and must be situated in the vacuum system, making them cost-intensive. In 2017, Ma and coworkers proposed a scheme for the broadband quantum-noise reduction without the need of additional filter cavities. It was shown by Brown et al. that a similar scheme can be used to broadband-enhance interferometers with a detuned signal-recycling cavity. Here, we performed a proof-of-principle experiment of the proposal on a table-top-scale. Squeezed states were produced detuned to the carrier field of a \unit[2.5]{m}-linear cavity and read out in a bichromatic homodyne detection. The frequencies of the lower and upper local oscillator were at entangled sidebands of the squeezed field. Depending on the relations between the involved frequencies, we can address both variants of the proposal. We show, that the frequency-dependences of the resulting noise spectra fit to a theoretical model we derived from the theory used by Ma et al. With this work we set the path towards an implementation of these schemes in a GW-detector prototype, where the compatibility of the approach with a low-frequency suspended interferometer can be tested. Moreover, we used the same setup to show nonclassical interferometer enhancement at low frequencies by high-frequency squeezed states. Here, a heterodyne readout scheme was implemented to avoid limiting noises at low frequencies. The application of squeezed states centered around the local oscillator frequency yielded an improvement in signal-to-noise ratio of $\unit[3.4]{dB}\pm\unit[0.3]{dB}$. Additionally, I designed, built and characterized a compact source of squeezed vacuum-states at \unit[1064]{nm} with a footprint of just $\unit[0.8]{m^2}$. I show measurements of squeezed states from this source with a reduction of quantum noise of $\unit[10.7]{dB}\pm\unit[0.2]{dB}$ below the vacuum noise and present a noise reduction in the frequency range from \unit[70]{kHz} to \unit[65]{MHz}.
During the recent years an international network of interferometric gravitational wave (GW) detectors has been commissioned and searches for various classes of GWsignals are ongoing.Although the observatories are beginning to reach astrophysically interesting sensitivity levels, extensive upgrades are aimed for the next decade bringing us into the era of gravitational wave astronomy.One approach to enhance the detector sensitivity is the injection of squeezed vacuum states of light replacing the vacuum fluctuations entering the detector through its antisymmetric port.In this thesis the unprecedented generation of squeezed vacuum states with a noise power 6.5 dB below vacuum noise within the entire detection bandwidth of ground-based GW-detectors (10 Hz -10 kHz) was experimentally demonstrated at a wavelength of 1064 nm.For the first time a coherent control scheme was employed for comprehensive phase control of the experimental setup.This scheme is directly applicable to future GW-detector topologies.In addition, parasitic interference induced by scattered light was found to be a dominant noise source degrading squeezed states in the audio band.The compatibility of squeezed field injection into a detuned operated dual-recycled Michelson interferometer was demonstrated in a table top experiment.A detected non-classical sensitivity improvement of up to 3.0 dB within the entire detection bandwidth (5 -15 MHz) was accomplished by optimal preparation of the injected squeezing by means of a detuned locked filter cavity.In a further experiment strongly squeezed vacuum states were generated in the MHz-regime.With a maximum measured quantum noise reduction of 11.5 dB below the shot noise limit a new benchmark was set.This was achieved by suppression of phase noise and a remarkable reduction of optical loss in the experimental setup.Based on the squeezed light sources developed in this thesis and the experimental results achieved, a conceptual design of a compact squeezed light source was devised, allowing for a high duty cycle sensitivity improvement of GW-detectors.