Beyond the quantum limit : a squeezed-light laser in GEO 600
Khalaidovski, Aleksandr
Abstract
Albert Einstein's General Theory of Relativity predicts the existence of ripples in space- time, the so-called gravitational waves (GWs). In the past two decades, an international array of ground-based, kilometer-scale Michelson interferometers has been set up aiming at a rst observation. These Earth-bound GW detectors target signals at audio frequen- cies in a band of ca. 10 Hz { 10 kHz. At Fourier frequencies above 1 kHz, their sensitivity is limited by quantum noise. This shot-noise arises from the zero-point uctuations of the electromagnetic eld, the so-called vacuum uctuations , which enter the interferometer through its anti-symmetric signal port. Future generations of GW observatories will even be limited by quantum noise almost over their entire detection band [ ET ]. A `classical' solution to further improve the signal-to-shot-noise ratio (SNR) of the observatories consists in an increase of the circulating light power. A higher optical load inside the interferometer will, however, lead to thermally-induced beam distortion as well as to an increased radiation pressure noise level. This will eectively result in an upper limit for the optical light power employable in future GW observatory generations. An alternative approach to improve the SNR is based on the injection of so-called squeezed states of light. Such a light eld has a characteristic non-classical noise distribution in the eld quadratures. Injected from the signal port, the squeezed state replaces the vacuum state, thereby reducing the interferometer's quantum noise. The rst part of this thesis discusses the setup of a squeezed-light laser for the German- British GW observatory GEO 600. During characterization of the device, a noise reduc- tion of up to 9.6 dB below the vacuum noise level was observed in the frequency band of 10 Hz {10 kHz, setting a new benchmark for squeezing observed at audio frequencies. Corrected for detection losses, this value furthermore corresponds to more than 11 dB of squeezing available for injection into the dark port of GEO 600. Situated on a 1 : 15 m 1 : 35 m optical breadboard, the device features transportability and can be operated independently of the GW interferometer. A key feature of the squeezed-light laser is its unprecedented long-term stability. The longest characterization measurements lasted for 20 h with an overall duty cycle of more than 99 %. In the second part of this thesis, the implementation of squeezed light into GEO 600 is presented along with the results achieved. The observatory shot noise was reduced by up to 3.4 dB, corresponding to an improvement in sensitivity by a factor of up to 1.5. For isotropically distributed GW sources, this corresponds to an increase in detection probability by 1.5 3 3.4. This makes GEO 600 the rst large-scale GW interferometer with a non-classically enhanced sensitivity. Based on the performance of the squeezed- light laser, a sensitivity improvement by a factor of two, corresponding to an equivalent optical power increase by a factor of four, seems feasible in the near future.