Dark-field polarization post-selected weak measurement circumvents detector saturation in label-free phase imaging

Zheng Xing, Xiaochen Yuan, Chan–Tong Lam

Published Nov 18, 2026• 0 citations
Publisher

Abstract

Label-free phase imaging of biological membranes faces a fundamental trade-off: achieving shot-noise-limited sensitivity demands high illumination power, but the resulting intense background saturates photodetectors, forcing attenuation that discards signal photons. Conventional weak-value amplification and classical dark-field imaging cannot resolve this limitation, as background and signal photons are filtered proportionally without intrinsic separation. Here we propose and theoretically prove that dark-field post-selection in a quantum weak measurement can circumvent this barrier. By projecting the probe onto a near-orthogonal polarization state, the strong static background is physically blocked while the weak, rapidly varying membrane potential signal is amplified into a detectable photon-number modulation. We rigorously derive the shot-noise-limited SNR for the post-selected scheme as $\mathrm{SNR}_{q} = 2\phi _{0}\sqrt{N_{\mathrm{total}}}$ SNR q = 2 ϕ 0 N total , independent of the post-selection angle, whereas the classical limit is clamped at $\phi _{0}\sqrt{N_{\mathrm{sat}}}$ ϕ 0 N sat due to detector saturation. Through Qiskit quantum circuit simulation and Monte Carlo photon statistics, we demonstrate that the quantum advantage persists under realistic imperfections, with required extinction ratios and readout noise levels comfortably met by standard laboratory equipment. These results establish dark-field quantum weak measurement as a practical modality for label-free functional imaging that fundamentally overcomes the detector saturation bottleneck.

DOI
10.1140/epjqt/s40507-026-00604-w

Related papers

High-resolution quantum-enhanced phase imaging of cells

Alberto Paniate, Giuseppe Ortolano, Sarika Soman +2 more

Recovering both amplitude and phase information from a system is a fundamental goal of optical imaging. At the same time, it is crucial to operate at low photon doses to avoid altering the sample, particularly in biological applications. Quantum imaging provides a powerful route to extract more information per photon than classical techniques, which are ultimately limited by shot-noise. However, the trade-off between quantum noise reduction and spatial resolution has long been regarded as a major obstacle to the application of quantum techniques to small cellular and sub-cellular structures, where they could offer the greatest benefits. Here, we overcome this limitation by demonstrating sub-shot-noise quantitative phase imaging of biological cells based on the transport-of-intensity equation, enabling high-fidelity, label-free imaging of key cellular and sub-cellular features. We achieve high-resolution phase imaging limited only by the numerical aperture, while simultaneously obtaining a resolution-independent quantum advantage. Unlike other quantum imaging approaches, our method operates in a quasi-single-shot, wide-field configuration, retrieves both phase and amplitude information, and does not rely on interferometric measurements, making it intrinsically fast and stable. These results pave the way for the immediate application of sub-shot-noise imaging in biological microscopy.

arXiv:2506.07965•Optica•Feb 23, 2026•6 citations

Enhanced long-wavelength signal detection via a quantum antenna

Ding Wang, Shenchao Jin, Xiayang Fan +5 more

Detection of long-wavelength signal is of importance for diverse sensing and communication applications. Conventional metal antennas are limited in this regime, particularly when compactness and high sensitivity are both required. Despite intrinsic advantages for electric-field sensing across an ultra-broad range from DC to terahertz, Rydberg atoms still face challenges in practical long-wavelength signal detection, motivating the development of more sensitive and scalable approaches. In this work, we experimentally show that such a signal acting on the Rydberg state can be converted into a polarization variation of the probe laser, and realize signal extraction by appropriately utilizing the polarization degrees of freedom. Based on such a mechanism, we further design and implement a quantum weak measurement scheme, which clearly suppresses the technical noise and leads to considerable improvement of performance. Evaluation of the sensitivities across different post-selection angles demonstrates that the weak measurement results agree well with the theoretical model predictions. The advantages of our method are analyzed from multiple aspects, including characterizing the responses over different frequencies and comparing the responses of the weak measurement scheme and the traditional transmission-based method. After accounting for the screening effect of a measured ratio of 17% where the Rb 87 atoms experience a substantially reduced field inside the glass cell, the performance reaches 33 μV cm −1 Hz −1/2 in sensitivity and 1.0 μV cm −1 in minimal detectable field for an integration time of 1000 s, as perceived by the atoms.

Photonics Research•Sep 18, 2026•1 citation

Metasurface-Assisted Quantum Nonlocal Weak-Measurement Microscopy

Jiawei Liu, Qiang Yang, Yichang Shou +5 more

In standard quantum weak measurements, preselection and postselection of quantum states are implemented in the same photon. Here we go beyond this restrictive setting and demonstrate that the preselection and postselection can be performed in two different photons, if the two photons are polarization entangled. The Pancharatnam-Berry phase metasurface is incorporated in the weak measurement system to perform weak coupling between probe wave function and spin observable. By introducing nonlocal weak measurement into the microscopy imaging system, it allows us to remotely switch different microscopy imaging modes of pure-phase objects, including bright-field, differential, and phase reconstruction. Furthermore, we demonstrate that the nonlocal weak-measurement scheme can prevent almost all environmental noise photons from detection and thus achieves a higher image contrast than the standard scheme at a low photon level. Our results provide the possibility to develop a quantum nonlocal weak-measurement microscope for label-free imaging of transparent biological samples.

Physical Review Letters•Jan 25, 2024•76 citations

Sub-Shot Noise Interferometry and Quantum Imaging

Richard E. Slusher, Arthur La Porta, Philippe Grangier +2 more

Optimizing the sensitivity for interferometric measurement of optical phase involves maximizing the intensity of the illuminating light source and minimizing any noise sources. Limits to the light source intensity may arise from the availability of a stable high-power laser or from damage to the system being measured. For example, we describe here a scanning confocal polarization microscope designed to image the dynamics of nerve networks. In this case the light intensity limit is set by several factors, including the scanning rate, the required response time and damage limits of the biological system. Assuming a stable experimental configuration for the interferometer and light source, the limiting noise source for visible light interferometry is shot-noise associated with the quantum state of the light inputs to the interferometer. Shot-noise can be thought of as arising from vacuum fluctuations entering the dark input port of the interferometer.(1) These vacuum field fluctuations combine with the light entering the other port to cause shot-noise in the detected photocurrent at the output ports of the interferometer. This shot-noise current normally limits the measured phase variance Δϕ to a value of 1/N where N is the average number of photons detected in a measurement interval. We describe an experiment which demonstrates that this shot-noise limit can be improved by injecting squeezed vacuum into the normally dark input port.(2) In this case the phase variance is reduced below the 1/N limit by the degree of squeezing. In contrast to early experiments,(2) we are now operating the interferometer in a dark fringe mode(3–5) in order to avoid setting a limit to the light level caused by detector saturation (near 1 mW).

Topical Meeting on Quantum-Limited Imaging and Image Processing•Jan 1, 1989•0 citations

Weak-value amplification beyond the standard quantum limit in position measurements

A. Nishizawa

In a weak measurement with postselection, a measurement value, called the weak value, can be amplified beyond the eigenvalues of an observable. However, there are some controversies whether weak-value amplification is practically useful in increasing the sensitivity of the measurement, in which fundamental quantum noise dominates. In this paper, we investigate the sensitivity limit of an optical interferometer when weak-value amplification is implemented, properly accounting for quantum shot noise and radiation-pressure noise. To do so, we formulate weak-value amplification in the Heisenberg picture instead of in the Schr\"odinger picture, which is conventionally used. This formulation enables us to understand intuitively what happens when the measurement outcome is postselected and the weak value is amplified. As a result, we find that the sensitivity limit is given by the standard quantum limit that is the same as in a standard interferometry. We also discuss a way to circumvent the standard quantum limit.

arXiv:1504.04777•Physical Review A•Sep 21, 2015•13 citations

Weak Value Amplification of a Post-Selected Single Photon

Matin Hallaji

Weak value amplification (WVA) is a measurement technique in which the effect of a pre- and post-selected system on a weakly interacting probe is magnified. In this thesis, I present the first experimental observation of WVA of a single photon. We observed that a signal photon - sent through a polarization interferometer and post-selected by photodetection in the almost-dark port - can act like eight photons. The effect of this single photon is measured as a nonlinear phase shift on a separate laser beam. The interaction between the two is mediated by a sample of laser- cooled 85Rb atoms. Electromagnetically induced transparency (EIT) is used to enhance the nonlinearity and overcome resonant absorption. I believe this work to be the first demonstration of WVA where a deterministic interaction is used to entangle two distinct optical systems. In WVA, the amplification is contingent on discarding a large portion of the original data set. While amplification increases measurement sensitivity, discarding data worsens it. Questioning whether these competing effects conspire to improve or diminish measurement accuracy has resulted recently in controversy. I address this question by calculating the maximum amount of information achievable with the WVA technique. By comparing this information to that achievable by the standard technique, where no post-selection is employed, I show that the WVA technique can be advantageous under a certain class of noise models. Finally, I propose a way to optimally apply the WVA technique.

•Jun 1, 2016•3 citations
Label-free phase imaging of biological membranes faces a fundamental trade-off: achieving shot-noise-limited sensitivity demands high illumination power, but the resulting intense background saturates photodetectors, forcing attenuation that discards signal photons. Conventional weak-value amplification and classical dark-field imaging cannot resolve this limitation, as background and signal photons are filtered proportionally without intrinsic separation. Here we propose and theoretically prove that dark-field post-selection in a quantum weak measurement can circumvent this barrier. By projecting the probe onto a near-orthogonal polarization state, the strong static background is physically blocked while the weak, rapidly varying membrane potential signal is amplified into a detectable photon-number modulation. We rigorously derive the shot-noise-limited SNR for the post-selected scheme as SNRq=2ϕ0Ntotal\mathrm{SNR}_{q} = 2\phi _{0}\sqrt{N_{\mathrm{total}}}SNRq​=2ϕ0​Ntotal​​ SNR q = 2 ϕ 0 N total , independent of the post-selection angle, whereas the classical limit is clamped at ϕ0Nsat\phi _{0}\sqrt{N_{\mathrm{sat}}}ϕ0​Nsat​​ ϕ 0 N sat due to detector saturation. Through Qiskit quantum circuit simulation and Monte Carlo photon statistics, we demonstrate that the quantum advantage persists under realistic imperfections, with required extinction ratios and readout noise levels comfortably met by standard laboratory equipment. These results establish dark-field quantum weak measurement as a practical modality for label-free functional imaging that fundamentally overcomes the detector saturation bottleneck.
Recovering both amplitude and phase information from a system is a fundamental goal of optical imaging. At the same time, it is crucial to operate at low photon doses to avoid altering the sample, particularly in biological applications. Quantum imaging provides a powerful route to extract more information per photon than classical techniques, which are ultimately limited by shot-noise. However, the trade-off between quantum noise reduction and spatial resolution has long been regarded as a major obstacle to the application of quantum techniques to small cellular and sub-cellular structures, where they could offer the greatest benefits. Here, we overcome this limitation by demonstrating sub-shot-noise quantitative phase imaging of biological cells based on the transport-of-intensity equation, enabling high-fidelity, label-free imaging of key cellular and sub-cellular features. We achieve high-resolution phase imaging limited only by the numerical aperture, while simultaneously obtaining a resolution-independent quantum advantage. Unlike other quantum imaging approaches, our method operates in a quasi-single-shot, wide-field configuration, retrieves both phase and amplitude information, and does not rely on interferometric measurements, making it intrinsically fast and stable. These results pave the way for the immediate application of sub-shot-noise imaging in biological microscopy.
Detection of long-wavelength signal is of importance for diverse sensing and communication applications. Conventional metal antennas are limited in this regime, particularly when compactness and high sensitivity are both required. Despite intrinsic advantages for electric-field sensing across an ultra-broad range from DC to terahertz, Rydberg atoms still face challenges in practical long-wavelength signal detection, motivating the development of more sensitive and scalable approaches. In this work, we experimentally show that such a signal acting on the Rydberg state can be converted into a polarization variation of the probe laser, and realize signal extraction by appropriately utilizing the polarization degrees of freedom. Based on such a mechanism, we further design and implement a quantum weak measurement scheme, which clearly suppresses the technical noise and leads to considerable improvement of performance. Evaluation of the sensitivities across different post-selection angles demonstrates that the weak measurement results agree well with the theoretical model predictions. The advantages of our method are analyzed from multiple aspects, including characterizing the responses over different frequencies and comparing the responses of the weak measurement scheme and the traditional transmission-based method. After accounting for the screening effect of a measured ratio of 17% where the Rb 87 atoms experience a substantially reduced field inside the glass cell, the performance reaches 33 μV cm −1 Hz −1/2 in sensitivity and 1.0 μV cm −1 in minimal detectable field for an integration time of 1000 s, as perceived by the atoms.
In standard quantum weak measurements, preselection and postselection of quantum states are implemented in the same photon. Here we go beyond this restrictive setting and demonstrate that the preselection and postselection can be performed in two different photons, if the two photons are polarization entangled. The Pancharatnam-Berry phase metasurface is incorporated in the weak measurement system to perform weak coupling between probe wave function and spin observable. By introducing nonlocal weak measurement into the microscopy imaging system, it allows us to remotely switch different microscopy imaging modes of pure-phase objects, including bright-field, differential, and phase reconstruction. Furthermore, we demonstrate that the nonlocal weak-measurement scheme can prevent almost all environmental noise photons from detection and thus achieves a higher image contrast than the standard scheme at a low photon level. Our results provide the possibility to develop a quantum nonlocal weak-measurement microscope for label-free imaging of transparent biological samples.
Optimizing the sensitivity for interferometric measurement of optical phase involves maximizing the intensity of the illuminating light source and minimizing any noise sources. Limits to the light source intensity may arise from the availability of a stable high-power laser or from damage to the system being measured. For example, we describe here a scanning confocal polarization microscope designed to image the dynamics of nerve networks. In this case the light intensity limit is set by several factors, including the scanning rate, the required response time and damage limits of the biological system. Assuming a stable experimental configuration for the interferometer and light source, the limiting noise source for visible light interferometry is shot-noise associated with the quantum state of the light inputs to the interferometer. Shot-noise can be thought of as arising from vacuum fluctuations entering the dark input port of the interferometer.(1) These vacuum field fluctuations combine with the light entering the other port to cause shot-noise in the detected photocurrent at the output ports of the interferometer. This shot-noise current normally limits the measured phase variance Δϕ to a value of 1/N where N is the average number of photons detected in a measurement interval. We describe an experiment which demonstrates that this shot-noise limit can be improved by injecting squeezed vacuum into the normally dark input port.(2) In this case the phase variance is reduced below the 1/N limit by the degree of squeezing. In contrast to early experiments,(2) we are now operating the interferometer in a dark fringe mode(3–5) in order to avoid setting a limit to the light level caused by detector saturation (near 1 mW).
In a weak measurement with postselection, a measurement value, called the weak value, can be amplified beyond the eigenvalues of an observable. However, there are some controversies whether weak-value amplification is practically useful in increasing the sensitivity of the measurement, in which fundamental quantum noise dominates. In this paper, we investigate the sensitivity limit of an optical interferometer when weak-value amplification is implemented, properly accounting for quantum shot noise and radiation-pressure noise. To do so, we formulate weak-value amplification in the Heisenberg picture instead of in the Schr\"odinger picture, which is conventionally used. This formulation enables us to understand intuitively what happens when the measurement outcome is postselected and the weak value is amplified. As a result, we find that the sensitivity limit is given by the standard quantum limit that is the same as in a standard interferometry. We also discuss a way to circumvent the standard quantum limit.
Weak value amplification (WVA) is a measurement technique in which the effect of a pre- and post-selected system on a weakly interacting probe is magnified. In this thesis, I present the first experimental observation of WVA of a single photon. We observed that a signal photon - sent through a polarization interferometer and post-selected by photodetection in the almost-dark port - can act like eight photons. The effect of this single photon is measured as a nonlinear phase shift on a separate laser beam. The interaction between the two is mediated by a sample of laser- cooled 85Rb atoms. Electromagnetically induced transparency (EIT) is used to enhance the nonlinearity and overcome resonant absorption. I believe this work to be the first demonstration of WVA where a deterministic interaction is used to entangle two distinct optical systems. In WVA, the amplification is contingent on discarding a large portion of the original data set. While amplification increases measurement sensitivity, discarding data worsens it. Questioning whether these competing effects conspire to improve or diminish measurement accuracy has resulted recently in controversy. I address this question by calculating the maximum amount of information achievable with the WVA technique. By comparing this information to that achievable by the standard technique, where no post-selection is employed, I show that the WVA technique can be advantageous under a certain class of noise models. Finally, I propose a way to optimally apply the WVA technique.