Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Optical Ion Clock with Engineered Immunity to Motion-Induced Frequency Shifts — E8 Intelligence Research

Andrew Stewart Caldin

Published Nov 10, 2026• 0 citations
Publisher

Abstract

Spectroscopic frequency shifts due to residual motion of the probed atoms significantly contribute to the uncertainty budgets of state-of-the-art optical ion clocks. For clock transitions with second-order Doppler and quadratic Stark shifts of opposite signs, it is possible to configure electrodynamic ion confinement such that these two shift effects become anticorrelated causing zero net shift. Here, we introduce a spectroscopic interrogation protocol which leads, for systems with unknown and varying motional energy gain rates, to first-order auto-suppression of corresponding frequency shifts without requiring the opposite-sign configuration. We experimentally demonstrate the proposed method on a new ytterbium ion optical clock probing the 467 nm electric octupole (E3) transition, where the combined fractional uncertainty contribution from motion-induced frequency shifts is reduced from $1.3\times10^{-18}$ to $0.3\times10^{-18}$. An interleaved optical frequency ratio measurement agai Author: Andrew Stewart Caldin, Independent Researcher, UK. Part of the E8 Intelligence Research series. Platform: e8intelligence.com

DOI
10.5281/zenodo.24099315

Related papers

Optical Ion Clock with Engineered Immunity to Motion-Induced Frequency Shifts

Mark Lide, Wesley Hardin, Christian Sanner

Spectroscopic frequency shifts due to residual motion of the probed atoms significantly contribute to the uncertainty budgets of state-of-the-art optical ion clocks. For clock transitions with second-order Doppler and quadratic Stark shifts of opposite signs, it is possible to configure electrodynamic ion confinement such that these two shift effects become anticorrelated causing zero net shift. Here, we introduce a spectroscopic interrogation protocol which leads, for systems with unknown and varying motional energy gain rates, to first-order auto-suppression of corresponding frequency shifts without requiring the opposite-sign configuration. We experimentally demonstrate the proposed method on a new ytterbium ion optical clock probing the 467 nm electric octupole (E3) transition, where the combined fractional uncertainty contribution from motion-induced frequency shifts is reduced from $1.3\times10^{-18}$ to $0.3\times10^{-18}$. An interleaved optical frequency ratio measurement against ytterbium's electric quadrupole transition (E2) at 435 nm delivers an E3/E2 frequency ratio of $0.932 \,829 \,404 \,530 \,965 \, 340 (39)$. Combined with previously published ratio data this leads to a limit for a potential fractional temporal variation of the fine-structure constant of $2.4 (2.7) \times 10^{-19}/$yr, in agreement with existing bounds.

physics.atom-phCross-listedarXiv:2609.26775•Sep 23, 2026

Single-Ion Atomic Clock with 3 × 10 − 18 Systematic Uncertainty

Nils Huntemann, Christian Sanner, B. Lipphardt +2 more

We experimentally investigate an optical frequency standard based on the (2)S1/2(F=0)→(2)F7/2(F=3) electric octupole (E3) transition of a single trapped (171)Yb+ ion. For the spectroscopy of this strongly forbidden transition, we utilize a Ramsey-type excitation scheme that provides immunity to probe-induced frequency shifts. The cancellation of these shifts is controlled by interleaved single-pulse Rabi spectroscopy, which reduces the related relative frequency uncertainty to 1.1×10(-18). To determine the frequency shift due to thermal radiation emitted by the ion's environment, we measure the static scalar differential polarizability of the E3 transition as 0.888(16)×10(-40) J m(2)/V(2) and a dynamic correction η(300 K)=-0.0015(7). This reduces the uncertainty due to thermal radiation to 1.8×10(-18). The residual motion of the ion yields the largest contribution (2.1×10(-18)) to the total systematic relative uncertainty of the clock of 3.2×10(-18).

arXiv:1602.03908•Physical Review Letters•Feb 8, 2016•702 citations

The Development of the NIM-Yb1 Ion Optical Clock

Shaoyang Dai, Yani Zuo, Chaowei Wang +6 more

Optical clocks serve as the benchmark devices for the next-generation definition of the second and have significant applications in testing the theories beyong the standard models, dark matter research, and related fields.The ytterbium ion optical clock, featuring two clock transition lines, is among the most precise optical clocks with the lowest uncertainties.The National Institute of Metrology, China (NIM), initiated research on ytterbium ion optical clocks in 2021.Based on an end-cap ion trap, a vacuum system has been established.A 370 nm thirdharmonic fiber laser, along with 760 nm and 935 nm DFB lasers, ensures a stable operation of the optical system.To date, both the electric quadrupole and electric octupole clock transitions have been observed.A 2.8 Hz linewidth of the electric octupole transition has been achieved, with a stability of 1.7E-15 τ -1/2 after closed-loop locking.The uncertainties due to AC Starks shift from clock laser and second-order Doppler shifts are being evaluated, with an expected total uncertainty below 5E-18.

URSI Asia-Pacific Radio Science Conference•Jan 1, 2025•1 citation

Evaluation of the electric quadrupole shift in the ytterbium single-ion optical clock

Chao-Wei Wang, Shao-Yang Dai, Ya-Ni Zuo +4 more

Abstract Optical clocks with ultralow uncertainty are strong candidates for the next redefinition of the SI second. The 171 Yb + single-ion clock is particularly attractive owing to its two clock transitions (E2 and E3) and its potential for low uncertainty. A major contribution to the uncertainty budget arises from the electric-quadrupole shift, caused by the interaction between the atomic quadrupole moment and the electric-field gradient at the trap center and strongly dependent on the orientation of the quantization axis. To evaluate this shift, a simplified orthogonal magnetic-field method was employed: three mutually orthogonal magnetic-field directions are generated together with an auxiliary non-orthogonal field. With a dual-condition locking scheme, we measure the E2 transition frequency differences between magnetic-field configurations, infer the electric-field gradient, and apply corrections for the associated quadratic Zeeman shifts. The uncertainty due to magnetic-field misalignment is quantified using a calibrated current-to-field model. The resulting electric-quadrupole shift correction for the 2 S 1/2 → 2 F 7/2 (E3) transition is 3.24 mHz, corresponding to a fractional uncertainty of 1.1×10 −18 in the absolute frequency measurement.

Chinese Physics B•Apr 17, 2026•0 citations

A dual species optical atomic clock

Martin Steinel

Frequency standards based on optical transitions between electronic states of trapped ions have reached uncertainties below 10−18 [1]. The Stark shift caused by room-temperature blackbody radiation (BBR) causes the largest correction for most high-performance optical clock. The systematic uncertainty of 171Yb+ clocks based on the 2S1/2 (F = 0) → 2D3/2 (F = 2) electric quadrupole (E2) and 2S1/2 (F = 0) → 2F7/2 (F = 3) electric octupole (E3) transitions is currently limited to 28×10−18 and 1.5×10−18, respectively, by the fractional accuracy of the differential polarizability Δαdc of approximately 2% [2]. In the scope of this thesis, a dual species clock based on 171Yb+ and 88Sr+ ions was set up, operated and evaluated, to overcome this barrier. Since Δαdc is known with a smaller fractional uncertainty of 0.04% for the 2S1/2 → 2D5/2 E2 transition of 88Sr+ [3], this allows for a transfer of Δαdc from 88Sr+ to 171Yb+ following a method proposed in [4]. The optical intensity of a laser is calibrated with the Stark shift it causes on the 88Sr+ clock transition, allowing for the determination of Δαdc of the 171Yb+ clock transitions. This allows for a reduction of the fractional uncertainty of Δαdc for both 171Yb+ clock transitions below 0.4% and clock operation on the E2 and E3 transition with a fractional BBR shift uncertainty of 0.84×10−18 and 0.24×10−18 is enabled, respectively. However the value of Δαdc determined in this thesis does not agree with [2], a fractional offset of approximately 14% is observed. To investigate this discrepancy further, Δαdc is measured in the same manner as in [2] for the 88Sr+ clock transition. The same offset of approximately 14% is found, calling the accuracy of at least one of these methods into question. Finally, the first optical frequency ratio ℛ between the 88Sr+ clock transition and the 171Yb+ E3 transition is measured. The fractional uncertainty of ℛ is 23×10−18. ℛ in combination with the absolute frequency of the E3 transition allows for the determination of the 88Sr+ absolute frequency νSr+ with an uncertainty limited by the caesium references. The value of νSr+ falls outside of the recommended range, but is corroborated by measurements of the same quantity by other institutes [5, 6]. [1] M. Marshall et al., Phys. Rev. Lett. 135, 033201 (2025) [2] N. Huntemann et al., Phys. Rev. Lett. 116, 063001 (2016) [3] T. Lindvall et al., Phys. Rev. Lett. 135, 043402 (2025) [4] M. D. Barrett et al., Phys. Rev. A 100, 043418 (2019) [5] C. Marceau et al., Metrologia 62.4, 045001 (2025) [6] T. Lindvall et al., Phys. Rev. Appl. 24, 044082 (2025)

•Dec 16, 2025•0 citations

A TRAPPED 171 Yb + ION OPTICAL FREQUENCY STANDARD BASED ON THE S 1/2 - F 7/2 TRANSITION

P. GILL, Stephen A. Webster, G. HUANG +7 more

The single cold 171 Yb + ion has two optical clock transitions available. One of these is the 2 S 1/2 - 2 D 3/2 quadrupole (E2) transition at 436 nm. The other is the 2 S 1/2 - 2 F 7/2 octupole (E3) transition at 467 nm, which has an extremely narrow theoretical linewidth on account of the 6-year lifetime of its F 7/2 upper level. This paper reports progress on both these clock transitions at NPL. In particular, the absolute frequency of the observed octupole transition has recently been measured with an uncertainty of 12 Hz (1σ) for an octupole linewidth of < 40 Hz. Contributions from major shifts such as the AC Stark shift and second order Zeeman shift have been measured, and quadrupole and blackbody shifts estimated. The frequency ratio between the 171 Yb + quadrupole and octupole transitions demonstrates one of the largest sensitivities for monitoring possible time variation of the fine structure constant. Ultra-stable probe laser light at 436 nm has recently been generated to interrogate the quadrupole clock transition, in preparation for measuring both clock transitions simultaneously.

Symposium on Frequency Standards and Metrology•May 1, 2009•0 citations
Spectroscopic frequency shifts due to residual motion of the probed atoms significantly contribute to the uncertainty budgets of state-of-the-art optical ion clocks. For clock transitions with second-order Doppler and quadratic Stark shifts of opposite signs, it is possible to configure electrodynamic ion confinement such that these two shift effects become anticorrelated causing zero net shift. Here, we introduce a spectroscopic interrogation protocol which leads, for systems with unknown and varying motional energy gain rates, to first-order auto-suppression of corresponding frequency shifts without requiring the opposite-sign configuration. We experimentally demonstrate the proposed method on a new ytterbium ion optical clock probing the 467 nm electric octupole (E3) transition, where the combined fractional uncertainty contribution from motion-induced frequency shifts is reduced from 1.3×10−181.3\times10^{-18}1.3×10−18 to 0.3×10−180.3\times10^{-18}0.3×10−18. An interleaved optical frequency ratio measurement agai Author: Andrew Stewart Caldin, Independent Researcher, UK. Part of the E8 Intelligence Research series. Platform: e8intelligence.com
Spectroscopic frequency shifts due to residual motion of the probed atoms significantly contribute to the uncertainty budgets of state-of-the-art optical ion clocks. For clock transitions with second-order Doppler and quadratic Stark shifts of opposite signs, it is possible to configure electrodynamic ion confinement such that these two shift effects become anticorrelated causing zero net shift. Here, we introduce a spectroscopic interrogation protocol which leads, for systems with unknown and varying motional energy gain rates, to first-order auto-suppression of corresponding frequency shifts without requiring the opposite-sign configuration. We experimentally demonstrate the proposed method on a new ytterbium ion optical clock probing the 467 nm electric octupole (E3) transition, where the combined fractional uncertainty contribution from motion-induced frequency shifts is reduced from 1.3×10−181.3\times10^{-18}1.3×10−18 to 0.3×10−180.3\times10^{-18}0.3×10−18. An interleaved optical frequency ratio measurement against ytterbium's electric quadrupole transition (E2) at 435 nm delivers an E3/E2 frequency ratio of 0.932 829 404 530 965 340(39)0.932 \,829 \,404 \,530 \,965 \, 340 (39)0.932829404530965340(39). Combined with previously published ratio data this leads to a limit for a potential fractional temporal variation of the fine-structure constant of 2.4(2.7)×10−19/2.4 (2.7) \times 10^{-19}/2.4(2.7)×10−19/yr, in agreement with existing bounds.
We experimentally investigate an optical frequency standard based on the (2)S1/2(F=0)→(2)F7/2(F=3) electric octupole (E3) transition of a single trapped (171)Yb+ ion. For the spectroscopy of this strongly forbidden transition, we utilize a Ramsey-type excitation scheme that provides immunity to probe-induced frequency shifts. The cancellation of these shifts is controlled by interleaved single-pulse Rabi spectroscopy, which reduces the related relative frequency uncertainty to 1.1×10(-18). To determine the frequency shift due to thermal radiation emitted by the ion's environment, we measure the static scalar differential polarizability of the E3 transition as 0.888(16)×10(-40) J m(2)/V(2) and a dynamic correction η(300 K)=-0.0015(7). This reduces the uncertainty due to thermal radiation to 1.8×10(-18). The residual motion of the ion yields the largest contribution (2.1×10(-18)) to the total systematic relative uncertainty of the clock of 3.2×10(-18).
Optical clocks serve as the benchmark devices for the next-generation definition of the second and have significant applications in testing the theories beyong the standard models, dark matter research, and related fields.The ytterbium ion optical clock, featuring two clock transition lines, is among the most precise optical clocks with the lowest uncertainties.The National Institute of Metrology, China (NIM), initiated research on ytterbium ion optical clocks in 2021.Based on an end-cap ion trap, a vacuum system has been established.A 370 nm thirdharmonic fiber laser, along with 760 nm and 935 nm DFB lasers, ensures a stable operation of the optical system.To date, both the electric quadrupole and electric octupole clock transitions have been observed.A 2.8 Hz linewidth of the electric octupole transition has been achieved, with a stability of 1.7E-15 τ -1/2 after closed-loop locking.The uncertainties due to AC Starks shift from clock laser and second-order Doppler shifts are being evaluated, with an expected total uncertainty below 5E-18.
Abstract Optical clocks with ultralow uncertainty are strong candidates for the next redefinition of the SI second. The 171 Yb + single-ion clock is particularly attractive owing to its two clock transitions (E2 and E3) and its potential for low uncertainty. A major contribution to the uncertainty budget arises from the electric-quadrupole shift, caused by the interaction between the atomic quadrupole moment and the electric-field gradient at the trap center and strongly dependent on the orientation of the quantization axis. To evaluate this shift, a simplified orthogonal magnetic-field method was employed: three mutually orthogonal magnetic-field directions are generated together with an auxiliary non-orthogonal field. With a dual-condition locking scheme, we measure the E2 transition frequency differences between magnetic-field configurations, infer the electric-field gradient, and apply corrections for the associated quadratic Zeeman shifts. The uncertainty due to magnetic-field misalignment is quantified using a calibrated current-to-field model. The resulting electric-quadrupole shift correction for the 2 S 1/2 → 2 F 7/2 (E3) transition is 3.24 mHz, corresponding to a fractional uncertainty of 1.1×10 −18 in the absolute frequency measurement.
Frequency standards based on optical transitions between electronic states of trapped ions have reached uncertainties below 10−18 [1]. The Stark shift caused by room-temperature blackbody radiation (BBR) causes the largest correction for most high-performance optical clock. The systematic uncertainty of 171Yb+ clocks based on the 2S1/2 (F = 0) → 2D3/2 (F = 2) electric quadrupole (E2) and 2S1/2 (F = 0) → 2F7/2 (F = 3) electric octupole (E3) transitions is currently limited to 28×10−18 and 1.5×10−18, respectively, by the fractional accuracy of the differential polarizability Δαdc of approximately 2% [2]. In the scope of this thesis, a dual species clock based on 171Yb+ and 88Sr+ ions was set up, operated and evaluated, to overcome this barrier. Since Δαdc is known with a smaller fractional uncertainty of 0.04% for the 2S1/2 → 2D5/2 E2 transition of 88Sr+ [3], this allows for a transfer of Δαdc from 88Sr+ to 171Yb+ following a method proposed in [4]. The optical intensity of a laser is calibrated with the Stark shift it causes on the 88Sr+ clock transition, allowing for the determination of Δαdc of the 171Yb+ clock transitions. This allows for a reduction of the fractional uncertainty of Δαdc for both 171Yb+ clock transitions below 0.4% and clock operation on the E2 and E3 transition with a fractional BBR shift uncertainty of 0.84×10−18 and 0.24×10−18 is enabled, respectively. However the value of Δαdc determined in this thesis does not agree with [2], a fractional offset of approximately 14% is observed. To investigate this discrepancy further, Δαdc is measured in the same manner as in [2] for the 88Sr+ clock transition. The same offset of approximately 14% is found, calling the accuracy of at least one of these methods into question. Finally, the first optical frequency ratio ℛ between the 88Sr+ clock transition and the 171Yb+ E3 transition is measured. The fractional uncertainty of ℛ is 23×10−18. ℛ in combination with the absolute frequency of the E3 transition allows for the determination of the 88Sr+ absolute frequency νSr+ with an uncertainty limited by the caesium references. The value of νSr+ falls outside of the recommended range, but is corroborated by measurements of the same quantity by other institutes [5, 6]. [1] M. Marshall et al., Phys. Rev. Lett. 135, 033201 (2025) [2] N. Huntemann et al., Phys. Rev. Lett. 116, 063001 (2016) [3] T. Lindvall et al., Phys. Rev. Lett. 135, 043402 (2025) [4] M. D. Barrett et al., Phys. Rev. A 100, 043418 (2019) [5] C. Marceau et al., Metrologia 62.4, 045001 (2025) [6] T. Lindvall et al., Phys. Rev. Appl. 24, 044082 (2025)
The single cold 171 Yb + ion has two optical clock transitions available. One of these is the 2 S 1/2 - 2 D 3/2 quadrupole (E2) transition at 436 nm. The other is the 2 S 1/2 - 2 F 7/2 octupole (E3) transition at 467 nm, which has an extremely narrow theoretical linewidth on account of the 6-year lifetime of its F 7/2 upper level. This paper reports progress on both these clock transitions at NPL. In particular, the absolute frequency of the observed octupole transition has recently been measured with an uncertainty of 12 Hz (1σ) for an octupole linewidth of < 40 Hz. Contributions from major shifts such as the AC Stark shift and second order Zeeman shift have been measured, and quadrupole and blackbody shifts estimated. The frequency ratio between the 171 Yb + quadrupole and octupole transitions demonstrates one of the largest sensitivities for monitoring possible time variation of the fine structure constant. Ultra-stable probe laser light at 436 nm has recently been generated to interrogate the quadrupole clock transition, in preparation for measuring both clock transitions simultaneously.