Journal of Experimental and Theoretical Physics Letters

Shot Noise Features of a Terahertz Superconducting Bolometer

Pavel A. Prudkovskii

Published Sep 1, 2026• 0 citations
Publisher

Abstract

The fluctuations in the response of a terahertz superconducting hot electron bolometer, associated with the discreteness of photon absorption events, during the detection of weak radiation fluxes, were theoretically studied. It is shown that the nonlinear dependence of the resistance of a superconducting NbN film near the critical temperature leads to an asymmetric distribution of the local temperature of the electron subsystem; an analytical expression for this distribution is obtained. Using numerical simulation, it is shown that the proximity of the bolometer operating point to the instability region located in the section of the negative slope of the current-voltage characteristic of the superconducting film, at weak radiation fluxes, can lead to a significant asymmetry in the distribution of the bolometer response and even to its non-monotonic dependence on the radiation intensity.

DOI
10.1134/s0021364026607712

Related papers

Terahertz Direct Detection Behavior of a Superconducting NbN bolometer by Noise Thermometry

Hao Gao, Wei Miao, Kangmin Zhou +1 more

In this paper, we report the investigation of direct detection behavior of a superconducting niobium nitride (NbN) hot electron bolometer (HEB) based on noise thermometry. The HEB consists of a microbridge made from 5.5 nm thick NbN film and a twin slot antenna for radiation coupling. In the microbridge, hot electron system is generated after radiation pumping and it creates extra noise at RF frequencies. We measured the response of the noise at 0.5-1.8 GHz and the noise equivalent power (NEP) of the superconducting NbN HEB at different bias voltages. The measurement result shows that the superconducting NbN HEB has a noise equivalent power of 1.24×10-12W/Hz1/2at its optimal bias point. We also compared the noise equivalent power measured by noise thermometry at two different readout bandwidths. The measured results are found to be in good agreement with the theoretical one.

International Conference on Infrared, Millimeter, and Terahertz Waves (IRMMW-THz)•Sep 1, 2019•0 citations

‘Elementary’ pulses in the response of a superconducting hot-electron bolometer to terahertz photons

T. I. Novikova, A. V. Osipenkov, P. Prudkovskii +1 more

Abstract Statistical characteristics of the photoresponse of a superconducting hot-electron bolometer detector were measured under illumination by low-power terahertz pulses of 25 ns duration and 1.5 THz frequency. The pulses were generated via nonlinear-optical effects of parametric down-conversion in Mg:LiNbO 3 crystal, which was cooled to 4.5 K and pumped by a pulsed laser. The asymmetric experimental histograms of the photoresponse values obtained at different levels of incident radiation power were approximated by the Poisson-weighted sum of functions representing the convolutions of varying numbers of Gaussian distributions of elementary photocurrent pulses and the dark current distribution. It was found that the average number, the mean value, and the variance of such elementary pulses change with incident power. Specifically, the mean value and standard deviation of these pulses both grow monotonically with the increase in the mean current response, while their number tends to reach saturation at high powers. Conclusions were made about the fluctuating nature of elementary pulses, which is related to the formation of different configurations of hot spots appearing due to absorption of photons in different areas of the superconducting film. An estimate of the maximum lifetime of a hot spot was made based on the experimental data.

Laser Physics Letters•Mar 31, 2026•2 citations

Rigorous Analysis of a Superconducting Hot-Electron Bolometer Mixer: Theory and Comparison with Experiment

Rainer S. Nebosis, Alexei D. Semenov, Yu. P. Gousev +1 more

We present theoretical analysis of the performance of a superconducting hot-electron bolometer mixer with electron cooling due to electron phonon interaction. The analysis is based on a complete set of thermal balance equations for phonons and electrons. A non-thermal action of a dc current has been considered phenomenologically using an analytical fit of isothermal current-voltage characteristics of the mixer. The operation point of the mixer has been determined as a result of the heating by both the power of a local oscillator and the power dissipated by the current. Electron temperature fluctuations, Nyquist noise, and shot noise have been supposed to only contribute to the mixer noise. The conversion gain and the noise temperature of the mixer have been evaluated taking into account an electro-thermal feedback between the mixer and an intermediate frequency circuit with an arbitrary impedance. We have obtained general expressions for the conversion gain, noise temperature and impedance which enabled us to estimate ultimate performance of a superconducting hot-electron bolometer mixer. Theoretical predictions are in good agreement with experimental results obtained for a NbN hot-electron bolometer mixer at a radiation frequency of 2.5 THz.

Softwaretechnik-Trends•Mar 1, 1996•22 citations

Statistical features of the response of a superconducting hot-electron bolometer to extremely weak terahertz pulses of picosecond and nanosecond duration

T. I. Novikova, Kirill A. Kuznetsov, I. V. Korolev +3 more

We study the statistical distributions of the output signals of a superconducting hot-electron bolometer (HEB) detector exposed to weak photon pulses of 1 THz (terahertz) frequency. Pulses with variable photon numbers were generated through strongly non-degenerate parametric downconversion (PDC) in a LiNbO3 crystal at 4.8 K. Fundamental differences in histograms are found between two PDC pumping modes, with pulse widths of 28 ps and 10 ns. HEB response to a picosecond THz pulse was detected in the form of a single elementary electrical pulse (SEP), with the average amplitude proportional to radiation intensity and dispersion relative to the bolometer's dark current. HEB responses to extremely weak radiation intensities have been recorded using nanosecond pulsed illumination. We found that nanosecond histograms are asymmetrical and broaden as radiation intensity increases, indicating that the nanosecond response consists of several SEPs. Poisson–Gauss approximation of histograms indicates that not only the average number of SEPs increase but also the average amplitude of a SEP increases with increasing power of incident THz radiation.

Applied Physics Letters•Sep 16, 2024•7 citations

Non-uniform absorption of terahertz radiation on superconducting hot electron bolometer microbridges

W. Miao, W. Zhang, Jiaqiang Zhong +5 more

We interpret the experimental observation of a frequency-dependence of superconducting hot electron bolometer (HEB) mixers by taking into account the non-uniform absorption of the terahertz radiation on the superconducting HEB microbridge. The radiation absorption is assumed to be proportional to the local surface resistance of the HEB microbridge, which is computed using the Mattis-Bardeen theory. With this assumption the dc and mixing characteristics of a superconducting niobium-nitride (NbN) HEB device have been modeled at frequencies below and above the equilibrium gap frequency of the NbN film.

Applied Physics Letters•Feb 3, 2014•25 citations

Linear and nonlinear characteristics of NbN hot electron bolometer devices

Yan Zhuang

The superconducting HEB device is so far the most promising low noise mixer in the THz frequency range. It out-performs other existing receiver systems because it has low noise temperature and sufficient bandwidth for applications in the FIR range such as astronomy, remote sensing and plasma diagnostics. This work investigates the linear and nonlinear characteristics of NbN Hot Electron Bolometer (HEB) devices. First of all, a thorough expression of the Johnson noise and the thermal fluctuation noise has been re-derived. Our circuit model is more preferable for the HEB devices than the traditional one being used for the semiconductor bolometer. Secondly, the equivalent noise temperature of our receiver system has been significantly improved: the noise temperature went from the original 5800K to a record of 500K for silicon substrate devices. We are also getting improved noise performance for the new MgO substrate devices. The simulation results agree with the measured data very well around the optimum operating point. Finally, the device in the unstable region can be stabilized by connecting a series resistor with higher resistance than the negative resistance of the device. Two frequencies are related to the oscillation waveforms of the voltage and the current of the device. The first one is the repetition frequency that is actually related to the external circuit. The second one is the relaxation frequency that is related to the intrinsic phenomena of the device itself. The domain wall velocity and the relaxation oscillation frequency have been calculated both theoretically and experimentally. The calculated results are within a satisfactory range compared with the measured data. Also, a thorough explanation of the device oscillation process has been presented.

Journal of Bioresource Management•Jan 1, 2002•4 citations
The fluctuations in the response of a terahertz superconducting hot electron bolometer, associated with the discreteness of photon absorption events, during the detection of weak radiation fluxes, were theoretically studied. It is shown that the nonlinear dependence of the resistance of a superconducting NbN film near the critical temperature leads to an asymmetric distribution of the local temperature of the electron subsystem; an analytical expression for this distribution is obtained. Using numerical simulation, it is shown that the proximity of the bolometer operating point to the instability region located in the section of the negative slope of the current-voltage characteristic of the superconducting film, at weak radiation fluxes, can lead to a significant asymmetry in the distribution of the bolometer response and even to its non-monotonic dependence on the radiation intensity.
In this paper, we report the investigation of direct detection behavior of a superconducting niobium nitride (NbN) hot electron bolometer (HEB) based on noise thermometry. The HEB consists of a microbridge made from 5.5 nm thick NbN film and a twin slot antenna for radiation coupling. In the microbridge, hot electron system is generated after radiation pumping and it creates extra noise at RF frequencies. We measured the response of the noise at 0.5-1.8 GHz and the noise equivalent power (NEP) of the superconducting NbN HEB at different bias voltages. The measurement result shows that the superconducting NbN HEB has a noise equivalent power of 1.24×10-12W/Hz1/2at its optimal bias point. We also compared the noise equivalent power measured by noise thermometry at two different readout bandwidths. The measured results are found to be in good agreement with the theoretical one.
Abstract Statistical characteristics of the photoresponse of a superconducting hot-electron bolometer detector were measured under illumination by low-power terahertz pulses of 25 ns duration and 1.5 THz frequency. The pulses were generated via nonlinear-optical effects of parametric down-conversion in Mg:LiNbO 3 crystal, which was cooled to 4.5 K and pumped by a pulsed laser. The asymmetric experimental histograms of the photoresponse values obtained at different levels of incident radiation power were approximated by the Poisson-weighted sum of functions representing the convolutions of varying numbers of Gaussian distributions of elementary photocurrent pulses and the dark current distribution. It was found that the average number, the mean value, and the variance of such elementary pulses change with incident power. Specifically, the mean value and standard deviation of these pulses both grow monotonically with the increase in the mean current response, while their number tends to reach saturation at high powers. Conclusions were made about the fluctuating nature of elementary pulses, which is related to the formation of different configurations of hot spots appearing due to absorption of photons in different areas of the superconducting film. An estimate of the maximum lifetime of a hot spot was made based on the experimental data.
We present theoretical analysis of the performance of a superconducting hot-electron bolometer mixer with electron cooling due to electron phonon interaction. The analysis is based on a complete set of thermal balance equations for phonons and electrons. A non-thermal action of a dc current has been considered phenomenologically using an analytical fit of isothermal current-voltage characteristics of the mixer. The operation point of the mixer has been determined as a result of the heating by both the power of a local oscillator and the power dissipated by the current. Electron temperature fluctuations, Nyquist noise, and shot noise have been supposed to only contribute to the mixer noise. The conversion gain and the noise temperature of the mixer have been evaluated taking into account an electro-thermal feedback between the mixer and an intermediate frequency circuit with an arbitrary impedance. We have obtained general expressions for the conversion gain, noise temperature and impedance which enabled us to estimate ultimate performance of a superconducting hot-electron bolometer mixer. Theoretical predictions are in good agreement with experimental results obtained for a NbN hot-electron bolometer mixer at a radiation frequency of 2.5 THz.
We study the statistical distributions of the output signals of a superconducting hot-electron bolometer (HEB) detector exposed to weak photon pulses of 1 THz (terahertz) frequency. Pulses with variable photon numbers were generated through strongly non-degenerate parametric downconversion (PDC) in a LiNbO3 crystal at 4.8 K. Fundamental differences in histograms are found between two PDC pumping modes, with pulse widths of 28 ps and 10 ns. HEB response to a picosecond THz pulse was detected in the form of a single elementary electrical pulse (SEP), with the average amplitude proportional to radiation intensity and dispersion relative to the bolometer's dark current. HEB responses to extremely weak radiation intensities have been recorded using nanosecond pulsed illumination. We found that nanosecond histograms are asymmetrical and broaden as radiation intensity increases, indicating that the nanosecond response consists of several SEPs. Poisson–Gauss approximation of histograms indicates that not only the average number of SEPs increase but also the average amplitude of a SEP increases with increasing power of incident THz radiation.
We interpret the experimental observation of a frequency-dependence of superconducting hot electron bolometer (HEB) mixers by taking into account the non-uniform absorption of the terahertz radiation on the superconducting HEB microbridge. The radiation absorption is assumed to be proportional to the local surface resistance of the HEB microbridge, which is computed using the Mattis-Bardeen theory. With this assumption the dc and mixing characteristics of a superconducting niobium-nitride (NbN) HEB device have been modeled at frequencies below and above the equilibrium gap frequency of the NbN film.
The superconducting HEB device is so far the most promising low noise mixer in the THz frequency range. It out-performs other existing receiver systems because it has low noise temperature and sufficient bandwidth for applications in the FIR range such as astronomy, remote sensing and plasma diagnostics. This work investigates the linear and nonlinear characteristics of NbN Hot Electron Bolometer (HEB) devices. First of all, a thorough expression of the Johnson noise and the thermal fluctuation noise has been re-derived. Our circuit model is more preferable for the HEB devices than the traditional one being used for the semiconductor bolometer. Secondly, the equivalent noise temperature of our receiver system has been significantly improved: the noise temperature went from the original 5800K to a record of 500K for silicon substrate devices. We are also getting improved noise performance for the new MgO substrate devices. The simulation results agree with the measured data very well around the optimum operating point. Finally, the device in the unstable region can be stabilized by connecting a series resistor with higher resistance than the negative resistance of the device. Two frequencies are related to the oscillation waveforms of the voltage and the current of the device. The first one is the repetition frequency that is actually related to the external circuit. The second one is the relaxation frequency that is related to the intrinsic phenomena of the device itself. The domain wall velocity and the relaxation oscillation frequency have been calculated both theoretically and experimentally. The calculated results are within a satisfactory range compared with the measured data. Also, a thorough explanation of the device oscillation process has been presented.