Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

International Conference on Infrared, Millimeter, and Terahertz Waves (IRMMW-THz)

Terahertz Direct Detection Behavior of a Superconducting NbN bolometer by Noise Thermometry

Hao Gao, Wei Miao, Kangmin Zhou, Sheng‐Cai Shi

Published Sep 1, 2019• 0 citations
Publisher

Abstract

In this paper, we report the investigation of direct detection behavior of a superconducting niobium nitride (NbN) hot electron bolometer (HEB) based on noise thermometry. The HEB consists of a microbridge made from 5.5 nm thick NbN film and a twin slot antenna for radiation coupling. In the microbridge, hot electron system is generated after radiation pumping and it creates extra noise at RF frequencies. We measured the response of the noise at 0.5-1.8 GHz and the noise equivalent power (NEP) of the superconducting NbN HEB at different bias voltages. The measurement result shows that the superconducting NbN HEB has a noise equivalent power of 1.24×10-12W/Hz1/2at its optimal bias point. We also compared the noise equivalent power measured by noise thermometry at two different readout bandwidths. The measured results are found to be in good agreement with the theoretical one.

DOI
10.1109/irmmw-thz.2019.8873966

Related papers

Investigation of superconducting NbN hot-electron bolometers for terahertz direct detection

Jiaqiang Zhong, Wei Miao, Wen Zhang +2 more

In this paper, we report on the terahertz (THz) direct detection performance of two superconducting niobium nitride (NbN) hot-electron bolometers (HEBs) of different micro-bridge sizes. At the optimum bias point, the two HEB devices show similar thermal conductance (~80nW/K). The measured responsivity coincides well with the electrical responsivity calculated from the measured current-voltage (IV) curves at different bath temperatures. The noise equivalent power (NEP) of the two HEB devices is found to be about 10-12W/√Hz.

URSI General Assembly and Scientific Symposium•Aug 1, 2014•0 citations

Terahertz direct detectors based on superconducting hot electron bolometers with microwave injection

Shoulu Jiang, X. F. Li, Runfeng Su +5 more

Terahertz (THz) direct detectors based on superconducting niobium nitride (NbN) hot electron bolometers (HEBs) with microwave (MW) injection have been studied. Compared to the thermal biasing method, the injected MW is used here to bias the HEB to the optimum point. MW can be expected to be used as the easy read out for the detecting array. The used NbN HEB has an excellent performance as heterodyne detector with the noise temperature of 403 K working at 4.2 K and 0.65 THz. As the result, the noise equivalent power (NEP) of 1.4 pW/Hz1/2and the response time of 64 ps have been obtained for the direct detectors with MW injection.

International Conference on Infrared, Millimeter, and Terahertz Waves (IRMMW-THz)•Aug 1, 2017•2 citations

Terahertz Direct Detectors Based on Superconducting Hot Electron Bolometers with Microwave Biasing

Shoulu Jiang, Xianfeng Li, Runfeng Su +7 more

Terahertz (THz) direct detectors based on superconducting niobium nitride (NbN) hot electron bolometers (HEBs) with microwave (MW) biasing are studied. The MW is used to bias the HEB to the optimum point and to readout the impedance changes caused by the incident THz signals. Compared with the thermal biasing method, this method would be more promising in large scale array with simple readout. The used NbN HEB has an excellent performance as heterodyne detector with the double sideband noise temperature (TN) of 403 K working at 4.2 K and 0.65 THz. As a result, the noise equivalent power of 1.5 pW/Hz1/2 and the response time of 64 ps are obtained for the direct detectors based on the NbN HEBs and working at 4.2 K and 0.65 THz.

Chinese Physics Letters•Aug 1, 2017•7 citations

Appropriate microwave frequency selection for biasing superconducting hot electron bolometers as terahertz direct detectors

Shoulu Jiang, X F Li, Xiaoqing Jia +5 more

Terahertz (THz) direct detectors based on superconducting niobium nitride (NbN) hot electron bolometers (HEBs) and biased by a simple microwave (MW) source have been studied. The frequency and power of the MW are selected by measuring the MW responses of the current–voltage ( I–V ) curves and resistance–temperature ( R–T ) curves of the NbN HEBs. The non-uniform absorption theory is used to explain the current jumps in the I–V curves and the resistance jumps in the R–T curves. Compared to the thermal biasing, the MW biasing method can improve the sensitivity, make the readout system much easier and consumes less liquid helium, which is important for long lasting experiments. The noise equivalent power (NEP) of 1.6 pW Hz −1/2 and the response time of 86 ps are obtained for the detectors working at 4.2 K and 0.65 THz.

Superconductor Science and Technology•Feb 22, 2017•28 citations

Terahertz (THz) direct detectors based on superconducting HEBs with thermal, THz and microwave biasing methods (Conference Presentation)

Jian Chen

Superconducting hot electron bolometers (HEBs) are widely used as terahertz (THz) heterodyne detectors (mixers) and becoming the most advantageous candidate for low noise receiver at frequencies above 1.2 THz. However, there is still lack of accurate theoretical modeling which explains the complex mechanism of different aspects of superconducting HEBs. These difficulties do not prevent researchers around the world from making experimental progress. In the last few years, superconducting HEBs are also used as THz direct detectors to develop the array for the applications in biology, medicine and security systems. Recently, a noise equivalent power (NEP) of 0.2 pW/√Hz at 2.5 THz is reported for the superconducting HEBs with thermal biasing. Instead of thermal one, microwave (MW) which was first used to stabilize the HEB mixer is also applied to bias the device as a direct detector. Furthermore, THz can be used to bias the HEBs, if THz sources can be provided easy. Although MW biasing can improve sensitivity of the superconducting HEB direct detectors, little work has been done to compare the responsivity and NEP among the THz direct detectors with thermal, THz and MW biasing. To find a best biasing method, we have studied the similarities and differences of the direct detectors based on the superconducting HEBs with three different biasing methods. The fabricated NbN HEB detectors consist of a complementary logarithmic-spiral antenna made of gold and an NbN film (bridge) connecting across the antenna’s inner terminals. We have fabricated the niobium nitride (NbN) superconducting HEB mixers with the system double sideband (DSB) noise temperature better than 8 times of the quantum limit: hf/kB (where h is the Planck constant, kB is the Boltzmann constant and f is the operating frequency) at the frequencies higher than 1 THz. Here, the mixer chips with the system DSB noise temperature of about 400 K and the intermediate frequency (IF) gain bandwidth (GBW) of larger than 5 GHz at 4.2 K and 0.65 THz have been used. As the direct detectors, the current responsivity of 290 A/W and 105 A/W are obtained for MW and THz biasing, which about one order higher than that of thermal biasing. The NEP of 2.7 pW/√Hz is obtained with MW biasing, which can be expected to be improved in the future.

Next-Generation Spectroscopic Technologies•May 14, 2019•0 citations

Terahertz (THz) Direct Detectors based on Superconducting HEBs with Thermal, Microwave and THz Biasing

Runfeng Su, Y. D. Zhang, Xuecou Tu +6 more

Terahertz (THz) direct detectors based on superconducting niobium nitride (NbN) hot electron bolometers (HEBs) with thermal, microwave (MW) and THz biasing have been studied at 0.65 THz and 4.2 K in detail. The current responsivity and noise equivalent power (NEP) have been measured and compared respectively. The detectors with the MW and THz biasing have about one order higher current responsivity than that of the thermal one. With the MW biasing, an NEP at the order of pW/√Hz is obtained by choosing the MW frequency and power appropriately.

International Conference on Infrared, Millimeter, and Terahertz Waves (IRMMW-THz)•Sep 1, 2018•0 citations
In this paper, we report the investigation of direct detection behavior of a superconducting niobium nitride (NbN) hot electron bolometer (HEB) based on noise thermometry. The HEB consists of a microbridge made from 5.5 nm thick NbN film and a twin slot antenna for radiation coupling. In the microbridge, hot electron system is generated after radiation pumping and it creates extra noise at RF frequencies. We measured the response of the noise at 0.5-1.8 GHz and the noise equivalent power (NEP) of the superconducting NbN HEB at different bias voltages. The measurement result shows that the superconducting NbN HEB has a noise equivalent power of 1.24×10-12W/Hz1/2at its optimal bias point. We also compared the noise equivalent power measured by noise thermometry at two different readout bandwidths. The measured results are found to be in good agreement with the theoretical one.
In this paper, we report on the terahertz (THz) direct detection performance of two superconducting niobium nitride (NbN) hot-electron bolometers (HEBs) of different micro-bridge sizes. At the optimum bias point, the two HEB devices show similar thermal conductance (~80nW/K). The measured responsivity coincides well with the electrical responsivity calculated from the measured current-voltage (IV) curves at different bath temperatures. The noise equivalent power (NEP) of the two HEB devices is found to be about 10-12W/√Hz.
Terahertz (THz) direct detectors based on superconducting niobium nitride (NbN) hot electron bolometers (HEBs) with microwave (MW) injection have been studied. Compared to the thermal biasing method, the injected MW is used here to bias the HEB to the optimum point. MW can be expected to be used as the easy read out for the detecting array. The used NbN HEB has an excellent performance as heterodyne detector with the noise temperature of 403 K working at 4.2 K and 0.65 THz. As the result, the noise equivalent power (NEP) of 1.4 pW/Hz1/2and the response time of 64 ps have been obtained for the direct detectors with MW injection.
Terahertz (THz) direct detectors based on superconducting niobium nitride (NbN) hot electron bolometers (HEBs) with microwave (MW) biasing are studied. The MW is used to bias the HEB to the optimum point and to readout the impedance changes caused by the incident THz signals. Compared with the thermal biasing method, this method would be more promising in large scale array with simple readout. The used NbN HEB has an excellent performance as heterodyne detector with the double sideband noise temperature (TN) of 403 K working at 4.2 K and 0.65 THz. As a result, the noise equivalent power of 1.5 pW/Hz1/2 and the response time of 64 ps are obtained for the direct detectors based on the NbN HEBs and working at 4.2 K and 0.65 THz.
Terahertz (THz) direct detectors based on superconducting niobium nitride (NbN) hot electron bolometers (HEBs) and biased by a simple microwave (MW) source have been studied. The frequency and power of the MW are selected by measuring the MW responses of the current–voltage ( I–V ) curves and resistance–temperature ( R–T ) curves of the NbN HEBs. The non-uniform absorption theory is used to explain the current jumps in the I–V curves and the resistance jumps in the R–T curves. Compared to the thermal biasing, the MW biasing method can improve the sensitivity, make the readout system much easier and consumes less liquid helium, which is important for long lasting experiments. The noise equivalent power (NEP) of 1.6 pW Hz −1/2 and the response time of 86 ps are obtained for the detectors working at 4.2 K and 0.65 THz.
Superconducting hot electron bolometers (HEBs) are widely used as terahertz (THz) heterodyne detectors (mixers) and becoming the most advantageous candidate for low noise receiver at frequencies above 1.2 THz. However, there is still lack of accurate theoretical modeling which explains the complex mechanism of different aspects of superconducting HEBs. These difficulties do not prevent researchers around the world from making experimental progress. In the last few years, superconducting HEBs are also used as THz direct detectors to develop the array for the applications in biology, medicine and security systems. Recently, a noise equivalent power (NEP) of 0.2 pW/√Hz at 2.5 THz is reported for the superconducting HEBs with thermal biasing. Instead of thermal one, microwave (MW) which was first used to stabilize the HEB mixer is also applied to bias the device as a direct detector. Furthermore, THz can be used to bias the HEBs, if THz sources can be provided easy. Although MW biasing can improve sensitivity of the superconducting HEB direct detectors, little work has been done to compare the responsivity and NEP among the THz direct detectors with thermal, THz and MW biasing. To find a best biasing method, we have studied the similarities and differences of the direct detectors based on the superconducting HEBs with three different biasing methods. The fabricated NbN HEB detectors consist of a complementary logarithmic-spiral antenna made of gold and an NbN film (bridge) connecting across the antenna’s inner terminals. We have fabricated the niobium nitride (NbN) superconducting HEB mixers with the system double sideband (DSB) noise temperature better than 8 times of the quantum limit: hf/kB (where h is the Planck constant, kB is the Boltzmann constant and f is the operating frequency) at the frequencies higher than 1 THz. Here, the mixer chips with the system DSB noise temperature of about 400 K and the intermediate frequency (IF) gain bandwidth (GBW) of larger than 5 GHz at 4.2 K and 0.65 THz have been used. As the direct detectors, the current responsivity of 290 A/W and 105 A/W are obtained for MW and THz biasing, which about one order higher than that of thermal biasing. The NEP of 2.7 pW/√Hz is obtained with MW biasing, which can be expected to be improved in the future.
Terahertz (THz) direct detectors based on superconducting niobium nitride (NbN) hot electron bolometers (HEBs) with thermal, microwave (MW) and THz biasing have been studied at 0.65 THz and 4.2 K in detail. The current responsivity and noise equivalent power (NEP) have been measured and compared respectively. The detectors with the MW and THz biasing have about one order higher current responsivity than that of the thermal one. With the MW biasing, an NEP at the order of pW/√Hz is obtained by choosing the MW frequency and power appropriately.