Technical Physics Letters
Benchmarking a Long-Range Interacting Fermionic Model on IBM Heron r2 Processors: Zero-Noise Extrapolation versus Symmetry-Based Post-Selection on a 6-Qubit Ring Testbed
A. G. Kiiamov, Tayurskii Dmitrii Albertovich
Abstract
We benchmark two error-mitigation strategies for digital quantum simulation of a long-range interacting fermionic model on IBM Heron r2 superconducting processors. The testbed is a minimal exactly solvable system—two spinless electrons on a 6-site ring with repulsive $${\text{1/}}r$$ chord-distance Coulomb interactions—whose ground state exhibits a smooth Wigner-dimer localization crossover quantified by the antipodal occupation probability $${P_3}(U)$$ . Circuit parameters of a particle-number-conserving variational ansatz are optimized classically; the quantum processors execute only final energy and configuration measurements. We compare (i) zero-noise extrapolation (ZNE) applied to the full Hamiltonian with (ii) a hybrid estimator in which the off-diagonal kinetic energy is measured with ZNE while the diagonal interaction energy is reconstructed from particle-number post-selected bitstrings. Across eight interaction strengths $$U{\text{/}}t \in [5,75]$$ , five measurement sessions on two devices (ibm_fez, ibm_marrakesh), and three circuit depths, the hybrid estimator achieves, in the interacting regime $$U{\text{/}}t \geqslant 15$$ , relative ground-state energy errors of 4.3–14% that decrease systematically with $$U$$ —an order of magnitude better than full-Hamiltonian ZNE (29–85%)—and reproduces the localization crossover in $${P_3}(U)$$ . At $$U{\text{/}}t = 5$$ , where $${E_0} \approx 0.08{\kern 1pt} t$$ renders the relative error ill-conditioned, the absolute hybrid error is $$0.62{\kern 1pt} t$$ , in line with the rest of the scan. A depth scan at fixed $$U{\text{/}}t = 45$$ shows that the shallowest circuit wins despite a 1.8% ansatz expressivity penalty, quantifying the expressivity–noise trade-off. Shot-noise uncertainties, recovered exactly from per-noise-factor data, are below one percentage point in relative energy error for the hybrid estimator (versus 7–14 percentage points for ZNE at equal shot budget) and an order of magnitude smaller than the measured inter-session calibration spread. The exact variational bound $${E_{{\text{exp}}}} \geqslant {E_{{\text{theory}}}}$$ is satisfied in all 27 full-Hamiltonian hardware energy measurements. All data were acquired with under nine minutes of QPU time on the free IBM Quantum Open Plan.