Tracking the progression of the bone resorption process is important for clinical research and development of pharmaceuticals for bone-related diseases. Although fluorescence imaging is found to be one of the powerful tools for studying bone, conventional fluorescence microscopy relies on extremely high excitation powers that induce photobleaching and phototoxic effects on biological samples, preventing long-term observations. To overcome these limitations, we propose a quantum light-based approach using entangled two-photon fluorescence microscopy (ETPFM). We demonstrate ETPFM for imaging fixed demineralized unstained and Hoechst- and DAPI-stained bone sections at photon fluxes nearly 6 orders of magnitude lower than classical two-photon excitation. This quantum-correlated light preserves tissue integrity, eliminates photobleaching, and reveals microstructures with high contrast. Endogenous fluorescence is detected without exogenous dyes, and osteoclast cells are clearly resolved in the stained bone sections. ETPFM thus provides a minimally invasive, quantum-enhanced approach for long-term imaging of bone microenvironments.
Tracking the progression of the bone resorption process is important for clinical research and development of pharmaceuticals for bone-related diseases. Although fluorescence imaging is found to be one of the powerful tools for studying bone, conventional fluorescence microscopy relies on extremely high excitation powers that induce photobleaching and phototoxic effects on biological samples, preventing long-term observations. To overcome these limitations, we propose a quantum light-based approach using entangled two-photon fluorescence microscopy (ETPFM). We demonstrate ETPFM for imaging fixed demineralized unstained and Hoechst- and DAPI-stained bone sections at photon fluxes nearly 6 orders of magnitude lower than classical two-photon excitation. This quantum-correlated light preserves tissue integrity, eliminates photobleaching, and reveals microstructures with high contrast. Endogenous fluorescence is detected without exogenous dyes, and osteoclast cells are clearly resolved in the stained bone sections. ETPFM thus provides a minimally invasive, quantum-enhanced approach for long-term imaging of bone microenvironments.
Light-induced tissue damage is a crucial limitation for traditional microscopy of the living brain, underscoring the need for new techniques that minimize exposure of samples to light. Here, we tested the hypothesis that quantum light, i.e., entangled photons, could detect brain structures at a lower excitation energy. In a proof of principle, we show microscopic images of fixed brain tissue in the hippocampus area created by fluorescence selective excitation in the process of entangled two-photon absorption in a scanning microscope. Quantum-enhanced entangled two-photon microscopy (TPM) had brain imaging capabilities at an unprecedented low excitation intensity of ∼3.6 × 10 7 photons/s, orders of magnitude lower than the excitation level for the classical two-photon fluorescence image obtained in the same microscope. The extremely low light probe intensity demonstrated in entangled TPM is of critical importance in the investigation of neural activity to minimize heating and photobleaching during repetitive imaging. It may have important functional implications in optogenetic technology, removing unintended heating and accumulated photodamage effects. This technology also opens avenues in spatially resolved brain tissue investigations with quantum light, providing new capabilities in local spectroscopy.
Correct biological interpretation from cell imaging can be achieved only if the observed phenomena proceed with negligible perturbation from the imaging system. Herein, we demonstrate microscopic images of breast cancer cells created by the fluorescence selectively excited in the process of entangled two-photon absorption in a scanning microscope at an excitation intensity orders of magnitude lower than that used for classical two-photon microscopy. Quantum enhanced entangled two-photon microscopy has shown cell imaging capabilities at an unprecedented low excitation intensity of ∼3.6 × 10 7 photons/s, which is a million times lower than the excitation level for the classical two-photon fluorescence image obtained in the same microscope. The extremely low light probe intensity demonstrated in entangled two-photon microscopy is of critical importance to minimize photobleaching during repetitive imaging and damage to cells in live-cell applications. This technology opens new avenues in cell investigations with light microscopy, such as enhanced selectivity and time–frequency resolution.
Quantum entanglement has been shown to imply correlations stronger than those allowed by classical models. The possibility of performing tasks that are classically impossible has made quantum entanglement a powerful resource for the development of novel methods and applications in various fields of research such as quantum computing, quantum cryptography, and quantum metrology. There is a great need for the development of next generation instrumentation and technologies utilizing entangled quantum light. Among the many applications of nonclassical states of light, nonlinear microscopy has the potential to make an impact in broad areas of science from physics to biology. Here, the microscopic image created by the fluorescence selectively excited by the process of the entangled two-photon absorption is reported. Entangled two-photon microscopy offers nonlinear imaging capabilities at an unprecedented low excitation intensity 10 7, which is 6 orders of magnitude lower than the excitation level for the classical two-photon image. The nonmonotonic dependence of the image on the femtosecond delay between the components of the entangled photon pair is demonstrated. This delay dependence is a result of specific quantum interference effects associated with the entanglement and this is not observable with classical excitation light. In combination with novel spectroscopic capabilities provided by a nonclassical light excitation, this is of critical importance for sensing and biological applications.
All forms of microscopy that have previously been developed rely on classical sources of light, which are relatively noisy by virtue of the photons arriving randomly in time and position. We propose a new technique of two-beam optical microscopy using a nonclassical light source comprising entangled photon pairs generated by the process of nonlinear optical parametric downconversion. Entangled-photon microscopy (EPM) has the potential for providing a substantial improvement over confocal laser scanning fluorescence microscopy (CLSM) as well as over two-photon laser scanning fluorescence microscopy (TPLSM). The latter technique relies on the proportionality of the two-photon absorption rate to the square of the optical photon-flux density, and makes use of a highly focused optical beam to localize the region from which fluorescence is observed. However, because the arrival of pairs of photons is accidental in TPLSM, relatively large values of the photon-flux density are required to achieve photon coincidence and hence absorption. This can lead to undesired phototoxicity and photobleaching of the specimen. EPM, in contrast, relies on the presence of highly correlated photon pairs, which enhances the two-photon absorption rate significantly and enables lower values of the photon-flux density to be used. The process depends linearly, rather than quadratically, on the photon-flux density. Further, the EPM interaction region can be controlled by the use of two beams, providing increased flexibility in the selection of desired regions of a specimen, and leading to enhanced axial and lateral resolution.
Abstract Entangled photons with time-energy correlations are predicted to have improved sensitivity compared with classical light in two-photon fluorescence, which is promising for lowering the phototoxicity in biomedical imaging. While the mechanism has been demonstrated in atoms and crystals, the effectiveness in biological molecules has been under debate. Here we report the experimental results, including both positive and negative ones, in various samples. While entanglement induced enhancement in the sum frequency generation of a nonlinear crystal was confirmed, we observe no such enhancement in the two-photon nonlinear process of various molecules. However, we observed classical two-photon fluorescence excited by nW light in rare earth element doped core-shell structure nano-crystals, which can also be used in sensitive biomedical imaging. Our results provide guidance in characterizing the effect of entanglement in two-photon processes.
Fluorescence microscopy has become integral to biological studies for the technique’s ability to elucidate structures of biomolecules for in-situ studies with high selectivity and specificity. Imaging of intrinsic indicators, such as fluorescent amino acids in proteins, provides important information, but can be challenging to accomplish. Current microscopy techniques that measure native fluorescence without the use of exogenous labels involve either direct UV excitation which is commonly non-localized and can be detrimental to the system, or multiphoton absorption which must be conducted at high intensities, therefore posing high risks of photodamage. As such, we seek to investigate an efficient way to gently excite native fluorescence in biological systems in a way that overcomes these limitations. Quantum entangled photon pairs generated via spontaneous parametric downconversion (SPDC), may be an alternative to conducting two-photon absorption (TPA) to excite fluorescence in amino acids without the high fluences currently used. These photon pairs are highly correlated in time. Thus, the arrival of one photon is simultaneously followed by the arrival of its sister photon. As a result, a molecule interacting with the photon pair should simultaneously absorb both photons, leading to a linear two-photon absorption rate, and the linearity of the two-photon process should dramatically reduce the light intensity necessary for TPA. Therefore, quantum entangled photon pairs offer the possibility of performing low intensity UV excitation using photons in the visible wavelength range. With this work, we generated and characterized entangled photons generated via SPDC, and investigated whether fluorescent amino acids can be excited, and the subsequent fluorescence induced with entangled two-photon absorption. Results show that much higher entangled two-photon rates than what are currently available are needed to measure significant signals with entangled two-photon excitation.