The Journal of Physical Chemistry Letters

Quantum Light-Enhanced Two-Photon Imaging of Breast Cancer Cells

Oleg P. Varnavski, Carolyn E. Gunthardt, Aasia O. Rehman, Gary D. Luker, Theodore G. Goodson III

Published Mar 23, 2022• 43 citations
Publisher

Abstract

Correct biological interpretation from cell imaging can be achieved only if the observed phenomena proceed with negligible perturbation from the imaging system. Herein, we demonstrate microscopic images of breast cancer cells created by the fluorescence selectively excited in the process of entangled two-photon absorption in a scanning microscope at an excitation intensity orders of magnitude lower than that used for classical two-photon microscopy. Quantum enhanced entangled two-photon microscopy has shown cell imaging capabilities at an unprecedented low excitation intensity of ∼3.6 × 10 7 photons/s, which is a million times lower than the excitation level for the classical two-photon fluorescence image obtained in the same microscope. The extremely low light probe intensity demonstrated in entangled two-photon microscopy is of critical importance to minimize photobleaching during repetitive imaging and damage to cells in live-cell applications. This technology opens new avenues in cell investigations with light microscopy, such as enhanced selectivity and time–frequency resolution.

DOI
10.1021/acs.jpclett.2c00695

Related papers

Two-Photon Fluorescence Microscopy at Extremely Low Excitation Intensity: The Power of Quantum Correlations

Oleg P. Varnavski, Theodore G. Goodson III

Quantum entanglement has been shown to imply correlations stronger than those allowed by classical models. The possibility of performing tasks that are classically impossible has made quantum entanglement a powerful resource for the development of novel methods and applications in various fields of research such as quantum computing, quantum cryptography, and quantum metrology. There is a great need for the development of next generation instrumentation and technologies utilizing entangled quantum light. Among the many applications of nonclassical states of light, nonlinear microscopy has the potential to make an impact in broad areas of science from physics to biology. Here, the microscopic image created by the fluorescence selectively excited by the process of the entangled two-photon absorption is reported. Entangled two-photon microscopy offers nonlinear imaging capabilities at an unprecedented low excitation intensity 10 7, which is 6 orders of magnitude lower than the excitation level for the classical two-photon image. The nonmonotonic dependence of the image on the femtosecond delay between the components of the entangled photon pair is demonstrated. This delay dependence is a result of specific quantum interference effects associated with the entanglement and this is not observable with classical excitation light. In combination with novel spectroscopic capabilities provided by a nonclassical light excitation, this is of critical importance for sensing and biological applications.

Journal of the American Chemical Society•Jul 9, 2020•91 citations

Imaging Brain Tissue with Quantum Light at Low Power

Oleg P. Varnavski, P. Johnson, Tiecheng Liu +3 more

Light-induced tissue damage is a crucial limitation for traditional microscopy of the living brain, underscoring the need for new techniques that minimize exposure of samples to light. Here, we tested the hypothesis that quantum light, i.e., entangled photons, could detect brain structures at a lower excitation energy. In a proof of principle, we show microscopic images of fixed brain tissue in the hippocampus area created by fluorescence selective excitation in the process of entangled two-photon absorption in a scanning microscope. Quantum-enhanced entangled two-photon microscopy (TPM) had brain imaging capabilities at an unprecedented low excitation intensity of ∼3.6 × 10 7 photons/s, orders of magnitude lower than the excitation level for the classical two-photon fluorescence image obtained in the same microscope. The extremely low light probe intensity demonstrated in entangled TPM is of critical importance in the investigation of neural activity to minimize heating and photobleaching during repetitive imaging. It may have important functional implications in optogenetic technology, removing unintended heating and accumulated photodamage effects. This technology also opens avenues in spatially resolved brain tissue investigations with quantum light, providing new capabilities in local spectroscopy.

The Journal of Physical Chemistry B•Nov 13, 2024•5 citations

Quantum Imaging of Bone Tissue Using Entangled Two-Photon Microscopy

Paloma Johnson, Bishal Saha, Oleg P. Varnavski +3 more

Tracking the progression of the bone resorption process is important for clinical research and development of pharmaceuticals for bone-related diseases. Although fluorescence imaging is found to be one of the powerful tools for studying bone, conventional fluorescence microscopy relies on extremely high excitation powers that induce photobleaching and phototoxic effects on biological samples, preventing long-term observations. To overcome these limitations, we propose a quantum light-based approach using entangled two-photon fluorescence microscopy (ETPFM). We demonstrate ETPFM for imaging fixed demineralized unstained and Hoechst- and DAPI-stained bone sections at photon fluxes nearly 6 orders of magnitude lower than classical two-photon excitation. This quantum-correlated light preserves tissue integrity, eliminates photobleaching, and reveals microstructures with high contrast. Endogenous fluorescence is detected without exogenous dyes, and osteoclast cells are clearly resolved in the stained bone sections. ETPFM thus provides a minimally invasive, quantum-enhanced approach for long-term imaging of bone microenvironments.

The Journal of Physical Chemistry B•Sep 4, 2026•0 citations

Investigating fluorescent amino acids with entangled two-photon excited fluorescence

Audrey V. Eshun, Ashleigh Wilson, Megan L. Shelby +8 more

Fluorescence microscopy has become integral to biological studies for the technique’s ability to elucidate structures of biomolecules for in-situ studies with high selectivity and specificity. Imaging of intrinsic indicators, such as fluorescent amino acids in proteins, provides important information, but can be challenging to accomplish. Current microscopy techniques that measure native fluorescence without the use of exogenous labels involve either direct UV excitation which is commonly non-localized and can be detrimental to the system, or multiphoton absorption which must be conducted at high intensities, therefore posing high risks of photodamage. As such, we seek to investigate an efficient way to gently excite native fluorescence in biological systems in a way that overcomes these limitations. Quantum entangled photon pairs generated via spontaneous parametric downconversion (SPDC), may be an alternative to conducting two-photon absorption (TPA) to excite fluorescence in amino acids without the high fluences currently used. These photon pairs are highly correlated in time. Thus, the arrival of one photon is simultaneously followed by the arrival of its sister photon. As a result, a molecule interacting with the photon pair should simultaneously absorb both photons, leading to a linear two-photon absorption rate, and the linearity of the two-photon process should dramatically reduce the light intensity necessary for TPA. Therefore, quantum entangled photon pairs offer the possibility of performing low intensity UV excitation using photons in the visible wavelength range. With this work, we generated and characterized entangled photons generated via SPDC, and investigated whether fluorescent amino acids can be excited, and the subsequent fluorescence induced with entangled two-photon absorption. Results show that much higher entangled two-photon rates than what are currently available are needed to measure significant signals with entangled two-photon excitation.

Quantum Effects and Measurement Techniques in Biology and Biophotonics•Mar 13, 2024•0 citations

Photon entanglement for life-science imaging: rethinking the limits of the possible

Aleksei M. Zheltikov, Marlan O. Scully

Abstract Quantum entanglement is a powerful resource that revolutionizes information science, opens new horizons in communication technologies, and pushes the frontiers of sensing and imaging. Whether or not the methods of quantum entanglement can be extended to life-science imaging is far from clear. Live biological systems are eluding quantum-optical probes, proving, time and time again, too lossy, too noisy, too warm, and too wet to be meaningfully studied by quantum states of light. The central difficulty that puts the main roadblock on the path toward entanglement-enhanced nonlinear bioimaging is that the two-photon absorption (TPA) of entangled photons can exceed the TPA of uncorrelated photons only at the level of incident photon flux densities as low as one photon per entanglement area per entanglement time. This fundamental limitation has long been believed to rule out even a thinnest chance for a success of bioimaging with entangled photons. Here, we show that new approaches in nonlinear and quantum optics, combined with the latest achievements in biotechnologies, open the routes toward efficient photon-entanglement-based strategies in TPA microscopy that can help confront long-standing challenges in life-science imaging. Unleashing the full potential of this approach will require, however, high throughputs of virus-construct delivery, high expression efficiencies of genetically encodable fluorescent markers, high-brightness sources of entangled photons, as well as a thoughtful entanglement engineering in time, space, pulse, and polarization modes. We demonstrate that suitably tailored nonlinear optical fibers can deliver entangled photon pairs confined to entanglement volumes many orders of magnitude smaller than the entanglement volumes attainable through spontaneous parametric down-conversion. These ultracompact modes of entangled photons are shown to enable a radical enhancement of the TPA of entangled photons, opening new avenues for quantum entanglement in life-science imaging.

Physics-Uspekhi•Mar 26, 2020•37 citations

Quantum microscopy of cells at the Heisenberg limit

Zhe He, Yide Zhang, Xin Tong +2 more

Entangled biphoton sources exhibit nonclassical characteristics and have been applied to imaging techniques such as ghost imaging, quantum holography, and quantum optical coherence tomography. The development of wide-field quantum imaging to date has been hindered by low spatial resolutions, speeds, and contrast-to-noise ratios (CNRs). Here, we present quantum microscopy by coincidence (QMC) with balanced pathlengths, which enables super-resolution imaging at the Heisenberg limit with substantially higher speeds and CNRs than existing wide-field quantum imaging methods. QMC benefits from a configuration with balanced pathlengths, where a pair of entangled photons traversing symmetric paths with balanced optical pathlengths in two arms behave like a single photon with half the wavelength, leading to a two-fold resolution improvement. Concurrently, QMC resists stray light up to 155 times stronger than classical signals. The low intensity and entanglement features of biphotons in QMC promise nondestructive bioimaging. QMC advances quantum imaging to the microscopic level with significant improvements in speed and CNR toward the bioimaging of cancer cells. We experimentally and theoretically prove that the configuration with balanced pathlengths illuminates an avenue for quantum-enhanced coincidence imaging at the Heisenberg limit.

arXiv:2303.04948•Nature Communications•Apr 28, 2023•86 citations
Correct biological interpretation from cell imaging can be achieved only if the observed phenomena proceed with negligible perturbation from the imaging system. Herein, we demonstrate microscopic images of breast cancer cells created by the fluorescence selectively excited in the process of entangled two-photon absorption in a scanning microscope at an excitation intensity orders of magnitude lower than that used for classical two-photon microscopy. Quantum enhanced entangled two-photon microscopy has shown cell imaging capabilities at an unprecedented low excitation intensity of ∼3.6 × 10 7 photons/s, which is a million times lower than the excitation level for the classical two-photon fluorescence image obtained in the same microscope. The extremely low light probe intensity demonstrated in entangled two-photon microscopy is of critical importance to minimize photobleaching during repetitive imaging and damage to cells in live-cell applications. This technology opens new avenues in cell investigations with light microscopy, such as enhanced selectivity and time–frequency resolution.
Quantum entanglement has been shown to imply correlations stronger than those allowed by classical models. The possibility of performing tasks that are classically impossible has made quantum entanglement a powerful resource for the development of novel methods and applications in various fields of research such as quantum computing, quantum cryptography, and quantum metrology. There is a great need for the development of next generation instrumentation and technologies utilizing entangled quantum light. Among the many applications of nonclassical states of light, nonlinear microscopy has the potential to make an impact in broad areas of science from physics to biology. Here, the microscopic image created by the fluorescence selectively excited by the process of the entangled two-photon absorption is reported. Entangled two-photon microscopy offers nonlinear imaging capabilities at an unprecedented low excitation intensity 10 7, which is 6 orders of magnitude lower than the excitation level for the classical two-photon image. The nonmonotonic dependence of the image on the femtosecond delay between the components of the entangled photon pair is demonstrated. This delay dependence is a result of specific quantum interference effects associated with the entanglement and this is not observable with classical excitation light. In combination with novel spectroscopic capabilities provided by a nonclassical light excitation, this is of critical importance for sensing and biological applications.
Light-induced tissue damage is a crucial limitation for traditional microscopy of the living brain, underscoring the need for new techniques that minimize exposure of samples to light. Here, we tested the hypothesis that quantum light, i.e., entangled photons, could detect brain structures at a lower excitation energy. In a proof of principle, we show microscopic images of fixed brain tissue in the hippocampus area created by fluorescence selective excitation in the process of entangled two-photon absorption in a scanning microscope. Quantum-enhanced entangled two-photon microscopy (TPM) had brain imaging capabilities at an unprecedented low excitation intensity of ∼3.6 × 10 7 photons/s, orders of magnitude lower than the excitation level for the classical two-photon fluorescence image obtained in the same microscope. The extremely low light probe intensity demonstrated in entangled TPM is of critical importance in the investigation of neural activity to minimize heating and photobleaching during repetitive imaging. It may have important functional implications in optogenetic technology, removing unintended heating and accumulated photodamage effects. This technology also opens avenues in spatially resolved brain tissue investigations with quantum light, providing new capabilities in local spectroscopy.
Tracking the progression of the bone resorption process is important for clinical research and development of pharmaceuticals for bone-related diseases. Although fluorescence imaging is found to be one of the powerful tools for studying bone, conventional fluorescence microscopy relies on extremely high excitation powers that induce photobleaching and phototoxic effects on biological samples, preventing long-term observations. To overcome these limitations, we propose a quantum light-based approach using entangled two-photon fluorescence microscopy (ETPFM). We demonstrate ETPFM for imaging fixed demineralized unstained and Hoechst- and DAPI-stained bone sections at photon fluxes nearly 6 orders of magnitude lower than classical two-photon excitation. This quantum-correlated light preserves tissue integrity, eliminates photobleaching, and reveals microstructures with high contrast. Endogenous fluorescence is detected without exogenous dyes, and osteoclast cells are clearly resolved in the stained bone sections. ETPFM thus provides a minimally invasive, quantum-enhanced approach for long-term imaging of bone microenvironments.
Fluorescence microscopy has become integral to biological studies for the technique’s ability to elucidate structures of biomolecules for in-situ studies with high selectivity and specificity. Imaging of intrinsic indicators, such as fluorescent amino acids in proteins, provides important information, but can be challenging to accomplish. Current microscopy techniques that measure native fluorescence without the use of exogenous labels involve either direct UV excitation which is commonly non-localized and can be detrimental to the system, or multiphoton absorption which must be conducted at high intensities, therefore posing high risks of photodamage. As such, we seek to investigate an efficient way to gently excite native fluorescence in biological systems in a way that overcomes these limitations. Quantum entangled photon pairs generated via spontaneous parametric downconversion (SPDC), may be an alternative to conducting two-photon absorption (TPA) to excite fluorescence in amino acids without the high fluences currently used. These photon pairs are highly correlated in time. Thus, the arrival of one photon is simultaneously followed by the arrival of its sister photon. As a result, a molecule interacting with the photon pair should simultaneously absorb both photons, leading to a linear two-photon absorption rate, and the linearity of the two-photon process should dramatically reduce the light intensity necessary for TPA. Therefore, quantum entangled photon pairs offer the possibility of performing low intensity UV excitation using photons in the visible wavelength range. With this work, we generated and characterized entangled photons generated via SPDC, and investigated whether fluorescent amino acids can be excited, and the subsequent fluorescence induced with entangled two-photon absorption. Results show that much higher entangled two-photon rates than what are currently available are needed to measure significant signals with entangled two-photon excitation.
Abstract Quantum entanglement is a powerful resource that revolutionizes information science, opens new horizons in communication technologies, and pushes the frontiers of sensing and imaging. Whether or not the methods of quantum entanglement can be extended to life-science imaging is far from clear. Live biological systems are eluding quantum-optical probes, proving, time and time again, too lossy, too noisy, too warm, and too wet to be meaningfully studied by quantum states of light. The central difficulty that puts the main roadblock on the path toward entanglement-enhanced nonlinear bioimaging is that the two-photon absorption (TPA) of entangled photons can exceed the TPA of uncorrelated photons only at the level of incident photon flux densities as low as one photon per entanglement area per entanglement time. This fundamental limitation has long been believed to rule out even a thinnest chance for a success of bioimaging with entangled photons. Here, we show that new approaches in nonlinear and quantum optics, combined with the latest achievements in biotechnologies, open the routes toward efficient photon-entanglement-based strategies in TPA microscopy that can help confront long-standing challenges in life-science imaging. Unleashing the full potential of this approach will require, however, high throughputs of virus-construct delivery, high expression efficiencies of genetically encodable fluorescent markers, high-brightness sources of entangled photons, as well as a thoughtful entanglement engineering in time, space, pulse, and polarization modes. We demonstrate that suitably tailored nonlinear optical fibers can deliver entangled photon pairs confined to entanglement volumes many orders of magnitude smaller than the entanglement volumes attainable through spontaneous parametric down-conversion. These ultracompact modes of entangled photons are shown to enable a radical enhancement of the TPA of entangled photons, opening new avenues for quantum entanglement in life-science imaging.
Entangled biphoton sources exhibit nonclassical characteristics and have been applied to imaging techniques such as ghost imaging, quantum holography, and quantum optical coherence tomography. The development of wide-field quantum imaging to date has been hindered by low spatial resolutions, speeds, and contrast-to-noise ratios (CNRs). Here, we present quantum microscopy by coincidence (QMC) with balanced pathlengths, which enables super-resolution imaging at the Heisenberg limit with substantially higher speeds and CNRs than existing wide-field quantum imaging methods. QMC benefits from a configuration with balanced pathlengths, where a pair of entangled photons traversing symmetric paths with balanced optical pathlengths in two arms behave like a single photon with half the wavelength, leading to a two-fold resolution improvement. Concurrently, QMC resists stray light up to 155 times stronger than classical signals. The low intensity and entanglement features of biphotons in QMC promise nondestructive bioimaging. QMC advances quantum imaging to the microscopic level with significant improvements in speed and CNR toward the bioimaging of cancer cells. We experimentally and theoretically prove that the configuration with balanced pathlengths illuminates an avenue for quantum-enhanced coincidence imaging at the Heisenberg limit.