Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Applied Physics Reviews

Mid-infrared multidimensional upconversion imaging: Progress and prospects

Jianan Fang, Kun Huang, Ruiyang Qin, Zhen Qi, Heping Zeng

Published Aug 21, 2026• 2 citations
Publisher

Abstract

Mid-infrared (MIR) imaging plays a pivotal role in chemical sensing, biomedicine, and material analysis, yet its further development is fundamentally constrained by limited room-temperature sensitivity and the lack of efficient multidimensional light-field control. In recent years, frequency upconversion imaging has emerged as a rapidly advancing approach that translates MIR signals to the visible or near-infrared domain, enabling high-sensitivity detection with mature, low-noise photonic platforms. More importantly, by engineering the pump field in nonlinear frequency conversion processes, a multidimensional imaging framework has been established, enabling indirect, all-optical encoding and retrieval of multiple degrees of freedom—including amplitude, phase, spectrum, time, and polarization—of MIR light fields. This paradigm shifts complex light-field manipulation from the MIR to technologically mature short-wavelength regimes, overcoming intrinsic limitations of conventional approaches. In this review, we systematically summarize the principles, architectures, and representative methodologies of MIR upconversion multidimensional imaging, and outline future directions toward high-sensitivity, high-dimensional, and integrated imaging systems, with implications extending to broader photonic and information processing domains.

DOI
10.1063/5.0342756

Related papers

Mid-infrared single-photon upconversion spectroscopy based on temporal-spectral quantum correlation

Yujie Cai, Yu Chen, Xiaoning Xin +2 more

Promoting the sensitivity of mid-infrared (MIR) spectroscopy to the single-photon level is a critical need for investigating photosensitive biological samples and chemical reactions. MIR spectroscopy based on frequency upconversion is a compelling pioneer allowing high-efficiency MIR spectral measurement with well-developed single-photon detectors, which overcomes the main limitations of high thermal noise of current MIR detectors. However, noise from other nonlinear processes caused by strong pump fields hinders the development of the upconversion-based MIR spectroscopy to reach the single-photon level. Here, a broadband MIR single-photon frequency upconversion spectroscopy is demonstrated based on the temporal-spectral quantum correlation of non-degenerate photon pairs, which is well preserved in the frequency upconversion process and is fully used in extracting the signals from tremendous noise caused by the strong pump. A correlation spectrum broader than 660 nm is achieved and applied for the demonstration of sample identification under a low incident photon flux of 0.09 average photons per pulse. The system is featured with non-destructive and robust operation, which makes single-photon-level MIR spectroscopy an appealing option in biochemical applications.

Photonics Research•Sep 22, 2022•28 citations

Quantum-enhanced mid-infrared single-photon frequency up-conversion detection with loss and noise resilience

Xiaoying Wang, Yu Chen, Yujie Cai +4 more

Mid-infrared (MIR) detection remains challenging due to limited detector sensitivity and strong background noise. Frequency up-conversion enables MIR detection with visible-range detectors but suffers from limited robustness and additional noise generated in the nonlinear process. We demonstrate a quantum-enhanced MIR frequency up-conversion detection system that generates strongly non-degenerate, time-correlated photon pairs via spontaneous parametric down-conversion and detects MIR photons under severe loss and noise. With a 62 dB transmission loss and background noise 28 times higher than the detected signal, the quantum signal-to-noise ratio substantially surpasses that of classical photon counting. The system achieves stable signal retrieval under unpredictable noise fluctuations, highlighting its robustness in dynamically varying environments. These results establish a basis for practical sensing and imaging applications of quantum-enhanced MIR detection.

Optics Letters•Oct 10, 2025•1 citation

Mid-infrared single-photon upconversion spectroscopy enabled by nonlocal wavelength-to-time mapping

Yujie Cai, Yu Chen, Konstantin E. Dorfman +4 more

Ultrasensitive spectroscopy is an essential component in mid-infrared (MIR) technology. However, the drawbacks of MIR detectors pose challenges to robust MIR spectroscopy at the single-photon level. We propose an MIR single-photon frequency upconversion spectroscopy nonlocally mapping the MIR information to the time domain. Broadband MIR photons from spontaneous parametric downconversion are frequency-upconverted to the near-infrared band with quantum correlation preservation. Via the group delay of fiber, the MIR spectral information within a 1.18-micrometer bandwidth of 2.76 to 3.94 micrometers is then successfully projected to arrival times of correlated photon pairs. Under the conditions of 6.4 × 10 6 photons per second illumination, the transmission spectra of polymers with single-photon sensitivity are demonstrated using single-pixel detectors. The developed approach circumvents scanning and frequency selection instability, which stands out for its inherent compatibility for evolving environments and scalability for various wavelengths. Because of its high sensitivity and robustness, characterization of biochemical samples and weak measurement of quantum systems are possible to foresee.

Science Advances•Apr 19, 2024•37 citations

Two-dimensional infrared and mid-infrared imaging by single-photon frequency upconversion

Ruikai Tang, Wenjie Wu, Xiongjie Li +3 more

Single-photon frequency upconversion is an effective method of infrared single-photon detection and imaging by converting the long-wavelength photons to shorter wavelengths to match the detector’s spectral response. We realized few-photon level 2D infrared imaging with a coincidence frequency upconversion system in a bulk periodically poled lithium niobate crystal. Moreover, the infrared photons carrying orbital angular momentum were converted to the visible regime with high efficiency, while the orbital angular momentum of the photons was well conserved during the frequency upconversion process. The single-photon frequency upconversion method was also used for mid-infrared imaging at 3.39 µm with high efficiency and low noise.

Journal of Modern Optics•Mar 17, 2015•15 citations

Mid-infrared quantum scanning microscopy via visible light beyond spatial correlations

Josué Ricardo León-Torres, Vasile-Laurenţiu Dosan, M. M. Ćurčić +4 more

The mid-infrared (MIR) region of the electromagnetic spectrum spans from 2- to 25-$μ\mathrm{m}$, serving as a valuable tool for accessing rich chemical information. Functional groups, lipids, and other complex molecules can be analyzed by optical absorption measurements due to their vibrational modes in the MIR spectral region. Over the past few decades, this field has faced challenges due to difficulties in generating MIR light and the limited maturity of detection systems in this spectral range. Quantum imaging with undetected light (QIUL) provides a spectrally tuneable photon-pair source, in which the sample can be illuminated with MIR light while visible (VIS) light is employed for detection and image reconstruction, overcoming the detection limitations and benefiting from the rich chemical information of the MIR spectral region. All previous QIUL implementations are based on spatial correlations, which are never perfect and thus hindered the imaging performance. In this work, we implement a raster-scanning QIUL method that is independent of the strength of the spatial correlations and achieves a spatial resolution beyond the limitations of these correlations.

arXiv:2505.04490•May 7, 2025•0 citations

QCL frequency stabilization and measurement with 100 Hz - level linewidth, drift and inaccuracy, using a robust upconversion technique

Michael G. Hansen, E. Magoulakis, Q.-F. Chen +2 more

The mid-infrared (MIR) spectral range (λ > 4.5 µm) is of interest in both applied and fundamental spectroscopy, for diverse applications such as trace gas detection and molecular frequency metrology. Approaches currently pursued for enabling MIR spectroscopy with accurate frequency control are based on generating the desired radiation by down-conversion, either of frequency combs or of cw near-infrared (NIR) sources. Such downconverted sources, however, typically have low power per frequency interval.

European Quantum Electronics Conference (EQEC)•Jun 21, 2015•0 citations
Mid-infrared (MIR) imaging plays a pivotal role in chemical sensing, biomedicine, and material analysis, yet its further development is fundamentally constrained by limited room-temperature sensitivity and the lack of efficient multidimensional light-field control. In recent years, frequency upconversion imaging has emerged as a rapidly advancing approach that translates MIR signals to the visible or near-infrared domain, enabling high-sensitivity detection with mature, low-noise photonic platforms. More importantly, by engineering the pump field in nonlinear frequency conversion processes, a multidimensional imaging framework has been established, enabling indirect, all-optical encoding and retrieval of multiple degrees of freedom—including amplitude, phase, spectrum, time, and polarization—of MIR light fields. This paradigm shifts complex light-field manipulation from the MIR to technologically mature short-wavelength regimes, overcoming intrinsic limitations of conventional approaches. In this review, we systematically summarize the principles, architectures, and representative methodologies of MIR upconversion multidimensional imaging, and outline future directions toward high-sensitivity, high-dimensional, and integrated imaging systems, with implications extending to broader photonic and information processing domains.
Promoting the sensitivity of mid-infrared (MIR) spectroscopy to the single-photon level is a critical need for investigating photosensitive biological samples and chemical reactions. MIR spectroscopy based on frequency upconversion is a compelling pioneer allowing high-efficiency MIR spectral measurement with well-developed single-photon detectors, which overcomes the main limitations of high thermal noise of current MIR detectors. However, noise from other nonlinear processes caused by strong pump fields hinders the development of the upconversion-based MIR spectroscopy to reach the single-photon level. Here, a broadband MIR single-photon frequency upconversion spectroscopy is demonstrated based on the temporal-spectral quantum correlation of non-degenerate photon pairs, which is well preserved in the frequency upconversion process and is fully used in extracting the signals from tremendous noise caused by the strong pump. A correlation spectrum broader than 660 nm is achieved and applied for the demonstration of sample identification under a low incident photon flux of 0.09 average photons per pulse. The system is featured with non-destructive and robust operation, which makes single-photon-level MIR spectroscopy an appealing option in biochemical applications.
Mid-infrared (MIR) detection remains challenging due to limited detector sensitivity and strong background noise. Frequency up-conversion enables MIR detection with visible-range detectors but suffers from limited robustness and additional noise generated in the nonlinear process. We demonstrate a quantum-enhanced MIR frequency up-conversion detection system that generates strongly non-degenerate, time-correlated photon pairs via spontaneous parametric down-conversion and detects MIR photons under severe loss and noise. With a 62 dB transmission loss and background noise 28 times higher than the detected signal, the quantum signal-to-noise ratio substantially surpasses that of classical photon counting. The system achieves stable signal retrieval under unpredictable noise fluctuations, highlighting its robustness in dynamically varying environments. These results establish a basis for practical sensing and imaging applications of quantum-enhanced MIR detection.
Ultrasensitive spectroscopy is an essential component in mid-infrared (MIR) technology. However, the drawbacks of MIR detectors pose challenges to robust MIR spectroscopy at the single-photon level. We propose an MIR single-photon frequency upconversion spectroscopy nonlocally mapping the MIR information to the time domain. Broadband MIR photons from spontaneous parametric downconversion are frequency-upconverted to the near-infrared band with quantum correlation preservation. Via the group delay of fiber, the MIR spectral information within a 1.18-micrometer bandwidth of 2.76 to 3.94 micrometers is then successfully projected to arrival times of correlated photon pairs. Under the conditions of 6.4 × 10 6 photons per second illumination, the transmission spectra of polymers with single-photon sensitivity are demonstrated using single-pixel detectors. The developed approach circumvents scanning and frequency selection instability, which stands out for its inherent compatibility for evolving environments and scalability for various wavelengths. Because of its high sensitivity and robustness, characterization of biochemical samples and weak measurement of quantum systems are possible to foresee.
Single-photon frequency upconversion is an effective method of infrared single-photon detection and imaging by converting the long-wavelength photons to shorter wavelengths to match the detector’s spectral response. We realized few-photon level 2D infrared imaging with a coincidence frequency upconversion system in a bulk periodically poled lithium niobate crystal. Moreover, the infrared photons carrying orbital angular momentum were converted to the visible regime with high efficiency, while the orbital angular momentum of the photons was well conserved during the frequency upconversion process. The single-photon frequency upconversion method was also used for mid-infrared imaging at 3.39 µm with high efficiency and low noise.
The mid-infrared (MIR) region of the electromagnetic spectrum spans from 2- to 25-μmμ\mathrm{m}μm, serving as a valuable tool for accessing rich chemical information. Functional groups, lipids, and other complex molecules can be analyzed by optical absorption measurements due to their vibrational modes in the MIR spectral region. Over the past few decades, this field has faced challenges due to difficulties in generating MIR light and the limited maturity of detection systems in this spectral range. Quantum imaging with undetected light (QIUL) provides a spectrally tuneable photon-pair source, in which the sample can be illuminated with MIR light while visible (VIS) light is employed for detection and image reconstruction, overcoming the detection limitations and benefiting from the rich chemical information of the MIR spectral region. All previous QIUL implementations are based on spatial correlations, which are never perfect and thus hindered the imaging performance. In this work, we implement a raster-scanning QIUL method that is independent of the strength of the spatial correlations and achieves a spatial resolution beyond the limitations of these correlations.
The mid-infrared (MIR) spectral range (λ > 4.5 µm) is of interest in both applied and fundamental spectroscopy, for diverse applications such as trace gas detection and molecular frequency metrology. Approaches currently pursued for enabling MIR spectroscopy with accurate frequency control are based on generating the desired radiation by down-conversion, either of frequency combs or of cw near-infrared (NIR) sources. Such downconverted sources, however, typically have low power per frequency interval.