Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

IEEE Transactions on Instrumentation and Measurement

Nonlinear Zeeman Effect Suppression for CPT Atom Magnetometers

Qiuchang Jia, Feifan Yang, Xianyang Huo, Pengcheng Du, Jin Li

Published Jan 1, 2026• 0 citations
Publisher

Abstract

Geomagnetic measurement relies on high-sensitivity sensors, where coherent population trapping (CPT) magnetometers show promise due to advantages such as no dead zone and miniaturization capability. However, their sensitivity in geomagnetic environments is limited by the nonlinear Zeeman effect. This article establishes a magnetic field measurement model that suppresses this effect by utilizing the linear relationship between the external magnetic field and the frequency difference of the two peaks resulting from the resplitting of the zeroth-order CPT resonance. Theoretical analysis confirms that, at geomagnetic field strength, the frequency difference maintains a strict linear proportionality of 55.713 kHz/mT, whereas traditional methods fail due to higher order energy shifts. To enhance the weak CPT resonance, a closed-loop control system based on spontaneous fluorescence feedback was implemented, stabilizing the excited-state population via real-time laser power adjustment. Experimental results show that under closed-loop operation, the CPT signal amplitude increases approximately threefold with no significant linewidth broadening, theoretically improving sensitivity by 1.1 times, and the resplit double-peak structure is clearly observed in a geomagnetic environment. This approach provides a viable strategy for improving the sensitivity and accuracy of CPT magnetometers in geomagnetic field measurements.

DOI
10.1109/tim.2026.3720863

Related papers

Magnetic Field Measurement Using Peak-Locked Zeeman Coherent Population Trapping Resonance in Rubidium Vapor

Renu Tripathi, G. S. Pati

A sensor for magnetic field measurement is developed using a small (centimeter size) rubidium cell. A high contrast Zeeman coherent population trapping (CPT) resonance is produced by the magnetic dither in the sensor solenoid, and a peak-locked servo is implemented for magnetic field measurement. Sensitivity close to 110 pT/ √Hz has been achieved in axial field measurement. The CPT-based magnetic sensor is capable of measuring sub-nanotesla level magnetic field variations at high (microtesla) field strength. We discussed possible sources of noise and broadening which are affecting the performance of the sensor, and suggest changes that will further improve the performance of the sensor.

IEEE photonics journal•Jun 13, 2019•8 citations

Four-peak tracking autonomous omni-directional CPT atomic magnetometer

XueFeng WANG, YiCheng DENG, XiangDong LU +2 more

Omni-directional measurement of the geomagnetic field in satellites is necessary. Coherent population trapping (CPT) atomic magnetometer is theoretically capable of omni-directional measurement of magnetic fields, but it requires a reference signal in the direction of the magnetic field. To solve this problem, a new control method was proposed in this paper to trap four CPT signals. First, the control system demodulates the CPT differential signals with n=–3, n=–2, n=+2, and n=+3 by a time-division frequency modulation. Second, these CPT differential signals are fused to obtain two new feedback signals: one feedback signal used to calibrate the central frequency between n=±2 or n=±3, and the other feedback signal used to adjust the frequency between the central frequency and the CPT signals with n=±2 or n=±3. When a change in the magnetic field direction causes CPT signals with n=±2 or ±3 to disappear, the two feedback signals remain unaffected. Therefore, this control method does not require a fluxgate magnetometer to provide the magnetic field direction for mode switching and can obtain continuous magnetic data without losing lock in the range of 0°–360°. This means that it is an autonomous omni-directional CPT atomic magnetometer.

Zhongguo kexue. Wulixue Lixue Tianwenxue•Sep 4, 2024•0 citations

Loop-locked coherent population trapping magnetometer based on a fiber electro-optic modulator

Yong Hu, Y. Y. Feng, Chi Xu +2 more

We have set up a coherent population trapping (CPT)-based magnetometer prototype with the D1 line of ⁸⁷Rb atoms. The dichromatic light field is derived from a fiber electro-optic modulator (FEOM) connected to an external cavity laser diode. A CPT resonance signal with a 516 Hz linewidth is observed. By feeding back the derivative of the resonance curve to the FEOM with a proportional integral controller, of which the voltage output is directly converted to the measured magnetic field intensity, the resonance peak is locked to the environmental magnetic field. The measurement data we have achieved are well matched with the data measured by a commercial fluxgate magnetometer within 2 nT, and the sensitivity is better than 8 pT/√Hz in a parallel B field.

Applied Optics•Mar 27, 2014•11 citations

CPT Magnetometer with Atomic Energy Level Modulation

Liu Guo-Bin, Runchang Du, Liu Chao-Yang +1 more

We propose and experimentally investigate a coherent population trapping state based magnetometer prototype with 87 Rb atoms. Through modulating Zeeman sublevels with an ac magnetic field, not only a phase sensitive detection scheme suitable for miniature magnetometer is realized, but also the detection resolution of magnetic field intensity could be improved by a factor of two. Our study result indicates that it is a promising low power consumption miniature sensitive low magnetic field sensor offering spatially resolved measurement at the sub-millimetre level.

Chinese Physics Letters•Feb 1, 2008•17 citations

Magnetic field stabilization system designed for the cold-atom coherent population-trapping clock

Zhan Chang, Zhu Ma, Jiatao Wu +4 more

Accurate control of magnetic fields is crucial for cold-atom experiments, often necessitating custom-designed control systems due to limitations in commercially available power supplies.Here, we demonstrate precise and flexible control of a static magnetic field by employing a field-programmable gate array and a feedback loop.This setup enables us to maintain exceptionally stable current with a fractional stability of 1 ppm within 30 s.The error signal of the feedback loop exhibited a noise level of 10 -5 A•Hz -1/2 for control bandwidths below 10 kHz.Utilizing this precise magnetic field control system, we investigate the second-order Zeeman shift in the context of cold-atom coherent population-trapping (CPT) clocks.Our analysis reveals the second-order Zeeman coefficient to be 574.21Hz/G 2 , with an uncertainty of 1.36 Hz/G 2 .Consequently, the magnetic field stabilization system we developed allows us to achieve a second-order Zeeman shift below 10 -14 , surpassing the long-term stability of current cold-atom CPT clocks.

Chinese Optics Letters•Jan 1, 2024•5 citations

Dead-Zone-Free Atomic Magnetometry with Simultaneous Excitation of Orientation and Alignment Resonances

Amit Ben-Kish, Michael V. Romalis

Atomic magnetometers have very high absolute precision and sensitivity to magnetic fields but suffer from a fundamental problem: the vectorial or tensorial interaction of light with atoms leads to "dead zones," certain orientations of the magnetic field where the magnetometer loses its sensitivity. We demonstrate a simple polarization modulation scheme that simultaneously creates coherent population trapping (CPT) in orientation and alignment, thereby eliminating dead zones. Using 87Rb in a 10 Torr buffer gas cell we measure narrow, high-contrast CPT transparency peaks for all orientations and also show the absence of systematic effects associated with nonlinear Zeeman splitting.

arXiv:1001.0345•Physical Review Letters•Nov 4, 2010•89 citations
Geomagnetic measurement relies on high-sensitivity sensors, where coherent population trapping (CPT) magnetometers show promise due to advantages such as no dead zone and miniaturization capability. However, their sensitivity in geomagnetic environments is limited by the nonlinear Zeeman effect. This article establishes a magnetic field measurement model that suppresses this effect by utilizing the linear relationship between the external magnetic field and the frequency difference of the two peaks resulting from the resplitting of the zeroth-order CPT resonance. Theoretical analysis confirms that, at geomagnetic field strength, the frequency difference maintains a strict linear proportionality of 55.713 kHz/mT, whereas traditional methods fail due to higher order energy shifts. To enhance the weak CPT resonance, a closed-loop control system based on spontaneous fluorescence feedback was implemented, stabilizing the excited-state population via real-time laser power adjustment. Experimental results show that under closed-loop operation, the CPT signal amplitude increases approximately threefold with no significant linewidth broadening, theoretically improving sensitivity by 1.1 times, and the resplit double-peak structure is clearly observed in a geomagnetic environment. This approach provides a viable strategy for improving the sensitivity and accuracy of CPT magnetometers in geomagnetic field measurements.
A sensor for magnetic field measurement is developed using a small (centimeter size) rubidium cell. A high contrast Zeeman coherent population trapping (CPT) resonance is produced by the magnetic dither in the sensor solenoid, and a peak-locked servo is implemented for magnetic field measurement. Sensitivity close to 110 pT/ √Hz has been achieved in axial field measurement. The CPT-based magnetic sensor is capable of measuring sub-nanotesla level magnetic field variations at high (microtesla) field strength. We discussed possible sources of noise and broadening which are affecting the performance of the sensor, and suggest changes that will further improve the performance of the sensor.
Omni-directional measurement of the geomagnetic field in satellites is necessary. Coherent population trapping (CPT) atomic magnetometer is theoretically capable of omni-directional measurement of magnetic fields, but it requires a reference signal in the direction of the magnetic field. To solve this problem, a new control method was proposed in this paper to trap four CPT signals. First, the control system demodulates the CPT differential signals with n=–3, n=–2, n=+2, and n=+3 by a time-division frequency modulation. Second, these CPT differential signals are fused to obtain two new feedback signals: one feedback signal used to calibrate the central frequency between n=±2 or n=±3, and the other feedback signal used to adjust the frequency between the central frequency and the CPT signals with n=±2 or n=±3. When a change in the magnetic field direction causes CPT signals with n=±2 or ±3 to disappear, the two feedback signals remain unaffected. Therefore, this control method does not require a fluxgate magnetometer to provide the magnetic field direction for mode switching and can obtain continuous magnetic data without losing lock in the range of 0°–360°. This means that it is an autonomous omni-directional CPT atomic magnetometer.
We have set up a coherent population trapping (CPT)-based magnetometer prototype with the D1 line of ⁸⁷Rb atoms. The dichromatic light field is derived from a fiber electro-optic modulator (FEOM) connected to an external cavity laser diode. A CPT resonance signal with a 516 Hz linewidth is observed. By feeding back the derivative of the resonance curve to the FEOM with a proportional integral controller, of which the voltage output is directly converted to the measured magnetic field intensity, the resonance peak is locked to the environmental magnetic field. The measurement data we have achieved are well matched with the data measured by a commercial fluxgate magnetometer within 2 nT, and the sensitivity is better than 8 pT/√Hz in a parallel B field.
We propose and experimentally investigate a coherent population trapping state based magnetometer prototype with 87 Rb atoms. Through modulating Zeeman sublevels with an ac magnetic field, not only a phase sensitive detection scheme suitable for miniature magnetometer is realized, but also the detection resolution of magnetic field intensity could be improved by a factor of two. Our study result indicates that it is a promising low power consumption miniature sensitive low magnetic field sensor offering spatially resolved measurement at the sub-millimetre level.
Accurate control of magnetic fields is crucial for cold-atom experiments, often necessitating custom-designed control systems due to limitations in commercially available power supplies.Here, we demonstrate precise and flexible control of a static magnetic field by employing a field-programmable gate array and a feedback loop.This setup enables us to maintain exceptionally stable current with a fractional stability of 1 ppm within 30 s.The error signal of the feedback loop exhibited a noise level of 10 -5 A•Hz -1/2 for control bandwidths below 10 kHz.Utilizing this precise magnetic field control system, we investigate the second-order Zeeman shift in the context of cold-atom coherent population-trapping (CPT) clocks.Our analysis reveals the second-order Zeeman coefficient to be 574.21Hz/G 2 , with an uncertainty of 1.36 Hz/G 2 .Consequently, the magnetic field stabilization system we developed allows us to achieve a second-order Zeeman shift below 10 -14 , surpassing the long-term stability of current cold-atom CPT clocks.
Atomic magnetometers have very high absolute precision and sensitivity to magnetic fields but suffer from a fundamental problem: the vectorial or tensorial interaction of light with atoms leads to "dead zones," certain orientations of the magnetic field where the magnetometer loses its sensitivity. We demonstrate a simple polarization modulation scheme that simultaneously creates coherent population trapping (CPT) in orientation and alignment, thereby eliminating dead zones. Using 87Rb in a 10 Torr buffer gas cell we measure narrow, high-contrast CPT transparency peaks for all orientations and also show the absence of systematic effects associated with nonlinear Zeeman splitting.