Chinese Optics Letters

Magnetic field stabilization system designed for the cold-atom coherent population-trapping clock

Zhan Chang, Zhu Ma, Jiatao Wu, Maojie Li, Chengyin Han, Bo Lü, Chaohong Lee

Published Jan 1, 2024• 5 citations
Publisher

Abstract

Accurate control of magnetic fields is crucial for cold-atom experiments, often necessitating custom-designed control systems due to limitations in commercially available power supplies.Here, we demonstrate precise and flexible control of a static magnetic field by employing a field-programmable gate array and a feedback loop.This setup enables us to maintain exceptionally stable current with a fractional stability of 1 ppm within 30 s.The error signal of the feedback loop exhibited a noise level of 10 -5 A•Hz -1/2 for control bandwidths below 10 kHz.Utilizing this precise magnetic field control system, we investigate the second-order Zeeman shift in the context of cold-atom coherent population-trapping (CPT) clocks.Our analysis reveals the second-order Zeeman coefficient to be 574.21Hz/G 2 , with an uncertainty of 1.36 Hz/G 2 .Consequently, the magnetic field stabilization system we developed allows us to achieve a second-order Zeeman shift below 10 -14 , surpassing the long-term stability of current cold-atom CPT clocks.

DOI
10.3788/col202422.080202

Related papers

Magnetic field stabilization system for atomic physics experiments

B. Merkel, K. Thirumalai, J. E. Tarlton +4 more

Atomic physics experiments commonly use millitesla-scale magnetic fields to provide a quantization axis. As atomic transition frequencies depend on the magnitude of this field, many experiments require a stable absolute field. Most setups use electromagnets, which require a power supply stability not usually met by commercially available units. We demonstrate the stabilization of a field of 14.6 mT to 4.3 nT rms noise (0.29 ppm), compared to noise of >100 nT without any stabilization. The rms noise is measured using a field-dependent hyperfine transition in a single 43Ca+ ion held in a Paul trap at the center of the magnetic field coils. For the 43Ca+ “atomic clock” qubit transition at 14.6 mT, which depends on the field only in second order, this would yield a projected coherence time of many hours. Our system consists of a feedback loop and a feedforward circuit that control the current through the field coils and could easily be adapted to other field amplitudes, making it suitable for other applications such as neutral atom traps.

arXiv:1808.03310•Review of Scientific Instruments•Apr 1, 2019•59 citations

Cold-atom double- Λ coherent population trapping clock

François-Xavier Esnault, E. Blanshan, Eugene N. Ivanov +3 more

Miniature atomic clocks based on coherent population trapping (CPT) states in thermal atoms are an important component in many field applications, particularly where satellite frequency standards are not accessible. Cold-atom CPT clocks promise improved accuracy and stability over existing commercial technologies. Here we demonstrate a cold-atom CPT clock based on ${}^{87}$Rb using a high-contrast double-$\ensuremath{\Lambda}$ configuration. Doppler frequency shifts are explained using a simple model and canceled by interrogating the atoms with counterpropagating light beams. We realize a compact cold-atom CPT clock with a fractional frequency stability of $4\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}11}{\ensuremath{\tau}}^{\ensuremath{-}1/2}$, thus demonstrating the potential of these devices. We also show that the long-term stability is currently limited by the second-order Zeeman shift to $2\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}12}$ at 1000 s.

Physical Review A•Oct 31, 2013•83 citations

Simple and active magnetic-field stabilization for cold atom experiments

Zhi-Xin Duan, Wei-Tao Wu, Yuetong Lin +1 more

Cold atom experiments usually need a controllable and low-noise bias magnetic field to provide a quantization axis. Most labs need home-made stabilization of the field according to the actual setup, as commercially available power supply cannot directly satisfy their requirements. Here, by measuring the field fluctuations and active feedback modulating current supply of the applied magnetic field, we successfully demonstrate a field of 10.58 G with a stability to the level of 2.8 × 10−7 in a duration of 5 min. The root mean square noise is reduced to 0.05 mG, compared to the noise of 1.3 mG without stabilization. The coherence time of the magnetic-field sensitive transition between the rubidium ground states F=1,mF=−1 and 1,0, as measured by Rabi oscillation, is extended to 19.2 ms from the unstabilized value of 1.3 ms. This result is long enough for most experiments on quantum simulation and precision measurement. As our system has no passive magnetic shielding and additional compensation coils, it is highly simple and compact to provide the stable magnetic field and would be adapted to various applications with cold atoms.

Review of Scientific Instruments•Dec 1, 2022•12 citations

Frequency biases in a cold-atom coherent population trapping clock

Elizabeth A. Donley, E. Blanshan, François-Xavier Esnault +1 more

A compact cold-atom clock based on coherent population trapping (CPT) has been developed. The clock typically demonstrates a short-term fractional frequency stability of 4×10−11/√τ, limited by frequency noise on the interrogation lasers. The clock interrogates a sample of 2×105atoms under free-fall with typical cycle and Ramsey periods of 50 ms and 16 ms, respectively. The largest two systematic frequency shifts that can limit the clock's long-term stability are the light shift and the Doppler shift.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•May 1, 2014•2 citations

Direct control of high magnetic fields for cold atom experiments based on NV centers

Alexander Hesse, Kerim Köster, Jakob M. Steiner +5 more

Abstract In ultracold quantum gases, the interactions between the individual atoms can be controlled by applying magnetic bias fields. As magnetic field fluctuations limit the precision here, typically a feedback loop needs to be employed to regulate the current through a pair of Helmholtz coils. No commercially available magnetic field sensor allows to measure large fields directly with high enough precision, leading to many unsatisfactory solutions being used in experiments. Here, we demonstrate a direct magnetic field stabilization in a regime previously not accessible, using NV centers as the magnetic field sensor. This allows us to measure and stabilize fields of 4.66 mT down to 12 nT RMS noise over the course of 24 h, measured on a 1 Hz bandwidth. We achieve a control of better than 1 ppm after 20 min of integration time, ensuring high long-term stability for experiments. This approach extends direct magnetic field control to strong magnetic fields, which could enable new precise quantum simulations in this regime.

arXiv:2003.08101•New Journal of Physics•Feb 1, 2021•8 citations

Cancellation of Doppler shifts in a cold-atom CPT clock

Elizabeth A. Donley, François-Xavier Esnault, E. Blanshan +1 more

A compact cold-atom clock based on coherent population trapping (CPT) is being developed. Long-term goals for the clock include achieving a fractional frequency accuracy of 1×10-13in a package of less than 10 cm3in volume. Here we present an overview of a prototype clock design, and a systematic evaluation of the first-order Doppler shift. We also introduce our second-generation physics package.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•Jul 1, 2013•2 citations
Accurate control of magnetic fields is crucial for cold-atom experiments, often necessitating custom-designed control systems due to limitations in commercially available power supplies.Here, we demonstrate precise and flexible control of a static magnetic field by employing a field-programmable gate array and a feedback loop.This setup enables us to maintain exceptionally stable current with a fractional stability of 1 ppm within 30 s.The error signal of the feedback loop exhibited a noise level of 10 -5 A•Hz -1/2 for control bandwidths below 10 kHz.Utilizing this precise magnetic field control system, we investigate the second-order Zeeman shift in the context of cold-atom coherent population-trapping (CPT) clocks.Our analysis reveals the second-order Zeeman coefficient to be 574.21Hz/G 2 , with an uncertainty of 1.36 Hz/G 2 .Consequently, the magnetic field stabilization system we developed allows us to achieve a second-order Zeeman shift below 10 -14 , surpassing the long-term stability of current cold-atom CPT clocks.
Atomic physics experiments commonly use millitesla-scale magnetic fields to provide a quantization axis. As atomic transition frequencies depend on the magnitude of this field, many experiments require a stable absolute field. Most setups use electromagnets, which require a power supply stability not usually met by commercially available units. We demonstrate the stabilization of a field of 14.6 mT to 4.3 nT rms noise (0.29 ppm), compared to noise of >100 nT without any stabilization. The rms noise is measured using a field-dependent hyperfine transition in a single 43Ca+ ion held in a Paul trap at the center of the magnetic field coils. For the 43Ca+ “atomic clock” qubit transition at 14.6 mT, which depends on the field only in second order, this would yield a projected coherence time of many hours. Our system consists of a feedback loop and a feedforward circuit that control the current through the field coils and could easily be adapted to other field amplitudes, making it suitable for other applications such as neutral atom traps.
Miniature atomic clocks based on coherent population trapping (CPT) states in thermal atoms are an important component in many field applications, particularly where satellite frequency standards are not accessible. Cold-atom CPT clocks promise improved accuracy and stability over existing commercial technologies. Here we demonstrate a cold-atom CPT clock based on 87{}^{87}87Rb using a high-contrast double-$\ensuremath{\Lambda}$ configuration. Doppler frequency shifts are explained using a simple model and canceled by interrogating the atoms with counterpropagating light beams. We realize a compact cold-atom CPT clock with a fractional frequency stability of $4\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}11}{\ensuremath{\tau}}^{\ensuremath{-}1/2}$, thus demonstrating the potential of these devices. We also show that the long-term stability is currently limited by the second-order Zeeman shift to $2\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}12}$ at 1000 s.
Cold atom experiments usually need a controllable and low-noise bias magnetic field to provide a quantization axis. Most labs need home-made stabilization of the field according to the actual setup, as commercially available power supply cannot directly satisfy their requirements. Here, by measuring the field fluctuations and active feedback modulating current supply of the applied magnetic field, we successfully demonstrate a field of 10.58 G with a stability to the level of 2.8 × 10−7 in a duration of 5 min. The root mean square noise is reduced to 0.05 mG, compared to the noise of 1.3 mG without stabilization. The coherence time of the magnetic-field sensitive transition between the rubidium ground states F=1,mF=−1 and 1,0, as measured by Rabi oscillation, is extended to 19.2 ms from the unstabilized value of 1.3 ms. This result is long enough for most experiments on quantum simulation and precision measurement. As our system has no passive magnetic shielding and additional compensation coils, it is highly simple and compact to provide the stable magnetic field and would be adapted to various applications with cold atoms.
A compact cold-atom clock based on coherent population trapping (CPT) has been developed. The clock typically demonstrates a short-term fractional frequency stability of 4×10−11/√τ, limited by frequency noise on the interrogation lasers. The clock interrogates a sample of 2×105atoms under free-fall with typical cycle and Ramsey periods of 50 ms and 16 ms, respectively. The largest two systematic frequency shifts that can limit the clock's long-term stability are the light shift and the Doppler shift.
Abstract In ultracold quantum gases, the interactions between the individual atoms can be controlled by applying magnetic bias fields. As magnetic field fluctuations limit the precision here, typically a feedback loop needs to be employed to regulate the current through a pair of Helmholtz coils. No commercially available magnetic field sensor allows to measure large fields directly with high enough precision, leading to many unsatisfactory solutions being used in experiments. Here, we demonstrate a direct magnetic field stabilization in a regime previously not accessible, using NV centers as the magnetic field sensor. This allows us to measure and stabilize fields of 4.66 mT down to 12 nT RMS noise over the course of 24 h, measured on a 1 Hz bandwidth. We achieve a control of better than 1 ppm after 20 min of integration time, ensuring high long-term stability for experiments. This approach extends direct magnetic field control to strong magnetic fields, which could enable new precise quantum simulations in this regime.