Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

IEEE Transactions on Applied Superconductivity

First Integration of Two-Level Time-Division Multiplexed Differential Readout With a Prototype CMB-S4 Detector Array

Brianna Cantrall, Shawn Henderson, Zeeshan Ahmed, Adam J. Anderson, Carina Baker, Shannon M. Duff, Malcolm Durkin, Sho M. Gibbs, Gunther M. Haller, Johannes Hubmayr, Hogan Nguyen, Christopher Rooney, L. Sapozhnikov, Sara M. Simon

Published Jul 29, 2026• 1 citation
Publisher

Abstract

Future cosmic microwave background (CMB) surveys will require an order of magnitude more detectors than are currently deployed in the most densely packed fielded experiments. This calls for a multiplexed readout capable of handling the increased integration complexity, heat load on the lowest temperature stages, and cost for such experiments. One choice of readout technology is direct current (DC) superconducting quantum interference device (SQUID)-based time-division multiplexing (TDM). This technology, along with transition-edge sensor (TES) detector technology, has been successfully deployed by multiple CMB experiments over the past decade. However, current experiments implementing TDM have not yet demonstrated the combination of multiplexing (MUX) factor, sampling rate, and noise performance at the scale of a next-generation experiment, such as CMB Stage 4 (CMB-S4). In order to meet these requirements, an advanced TDM architecture has been developed that features increased amplification of TES signals and increased bandwidth compared to previous MUX chip designs, as well as implementation of fully symmetric, differential circuits and hierarchical row addressing. We report on the first integration and noise characterization of this advanced TDM architecture with a prototype CMB-S4 dichroic detector wafer sensitive to the 90 and 150 GHz bands. Limitations of the legacy warm electronics used in this work preclude direct tests of the hierarchical MUX and fully differential signal paths; we instead focus on noise characterization at the SQUID and detector levels. Based on our measurements, the full system performance is projected to exceed CMB-S4 design requirements.

DOI
10.1109/tasc.2026.3718237

Related papers

Development of low-noise two-stage dc-SQUID for TES detector readout

Nan Li, Mengjie Song, Sixiao Hu +9 more

Abstract Direct-current superconducting quantum interference devices (dc-SQUIDs) are one of the most sensitive magnetic detectors. These sensors are extensively used in the readout of superconducting transition edge sensors (TESs), which are used for the detection of weak signals. A cosmic microwave background (CMB) polarization telescope operating in 22–48 GHz is currently under developing. The TESs calorimeter of the telescope will be readout by a time-division multiplexer SQUID readout system. We develop a two-stage dc-SQUID amplifier circuit, comprising an input-stage SQUID with 4 SQUID cells and a series SQUID array with 100 SQUID cells. This configuration has been shown to achieve extremely high signal gain while effectively controlling system noise. We assess the system noise at 300 mK in an adiabatic demagnetization refrigerator. The measured magnetic flux noise of the two-stage SQUID circuit system is approximately 0.3 μ Φ 0 / Hz at 10 kHz. The current noise equivalent to the input coil of input SQUID is about 2.4 pA / Hz . This result meets the low-noise readout requirements of the CMB TES and other applications with TES detectors.

arXiv:2601.19565•Superconductor Science and Technology•Apr 1, 2026•0 citations

Highly-multiplexed microwave SQUID readout using the SLAC Microresonator Radio Frequency (SMuRF) electronics for future CMB and sub-millimeter surveys

Shawn Henderson, Zeeshan Ahmed, David Brown +29 more

The next generation of cryogenic CMB and submillimeter cameras under development require densely instrumented sensor arrays to meet their science goals. The readout of large numbers (~10,000-100,000 per camera) of sub-Kelvin sensors, for instance as proposed for the CMB-S4 experiment, will require substantial improvements in cold and warm readout techniques. To reduce the readout cost per sensor and integration complexity, efforts are presently focused on achieving higher multiplexing density while maintaining readout noise subdominant to intrinsic detector noise and presenting manageable thermal loads. Highly-multiplexed cold readout technologies in active development include Microwave Kinetic Inductance Sensors (MKIDs) and microwave rf-SQUIDs. Both exploit the high quality factors of superconducting microwave resonators to densely channelize sub-Kelvin sensors into the bandwidth of a microwave transmission line. In the case of microwave SQUID multiplexing, arrays of transition-edge sensors (TES) are multiplexed by coupling each TES to its own superconducting microwave resonator through an rf-SQUID. We present advancements in the development of a new warm readout system for microwave SQUID multiplexing, the SLAC Superconducting Microresonator RF electronics, or SMuRF, by adapting SLAC National Accelerator Laboratory's Advanced Telecommunications Computing Architecture (ATCA) FPGA Common Platform. SMuRF aims to read out 4000 microwave SQUID channels between 4 and 8 GHz per RF line. Each compact SMuRF system is built onto a single ATCA carrier blade. Daughter boards on the blade implement RF frequency-division multiplexing using FPGAs, fast DACs and ADCs, and an analog up- and down-conversion chain. The system reads out changes in flux in each resonator-coupled rf-SQUID by monitoring the change in the transmitted amplitude and frequency of RF tones produced at each resonator's fundamental frequency. The SMuRF system is unique in its ability to track each tone, minimizing the total RF power required to readout each resonator, thereby significantly reducing the linearity requirements on the cold and warm readout. Here, we present measurements of the readout noise and linearity of the first full SMuRF system, including a demonstration of closed-loop tone tracking on a 528 channel cryogenic microwave SQUID multiplexer. SMuRF is being explored as a potential readout solution for a number of future CMB projects including Simons Observatory, BICEP Array, CCAT-prime, Ali-CPT, and CMB-S4. In addition, parallel development of the platform is underway to adapt SMuRF to read out both MKID and fast X-ray TES calorimeter arrays.

arXiv:1809.03689•Millimeter, Submillimeter, and Far-Infrared Detectors and Instrumentation for Astronomy XI•Jul 18, 2018•62 citations

Prototype of the room-temperature readout system for microwave multiplexing readout of transition edge sensor

Yuanda Wang, Cao Ping, Weigang Yin +8 more

Transition Edge Sensors (TESs) are highly sensitive cryogenic detectors widely used in astronomy, high-energy physics and nuclear radiation detection. As TES is increasingly deployed in large-scale arrays to improve sensitivity and effective collecting area, multiplexed readout becomes essential for reducing system complexity. Microwave SQUID multiplexing (μMUX) technology combining superconducting resonators with radio-frequency superconducting quantum interference devices (RF-SQUIDs), represents a state-of-the-art solution. In this work, a room-temperature readout prototype for TES μMUX readout was designed. The system features a scalable two-stage architecture, including a highly integrated, chassis-independent front-end signal processing module and back-end event-reconstruction module. A high-frequency-resolution frequency-comb signal generation method with real-time, per-tone frequency and phase tunability was developed. In addition, optimization of the firmware implementation effectively overcomes the computational-resource bottleneck of the Field Programmable Gate Array (FPGA). The prototype supports autonomous frequency sweeping, parameter diagnostics, and online event reconstruction. Self-test shows S 21 phase noise better than −110 dBc/Hz at −30 dBm, remaining stable with increasing channel count. Joint tests with a μMUX cryogenic system successfully captured the RF-SQUID response and achieved an equivalent noise current of 44 pA/√Hz referred to the TES, validating the prototype as a practical solution of the room-temperature system for TES μMUX readout.

Nuclear Engineering and Technology•Oct 30, 2026•0 citations

Microwave SQUID multiplexer demonstration for cosmic microwave background imagers

B. Dober, D. T. Becker, D. A. Bennett +10 more

Key performance characteristics are demonstrated for the microwave SQUID multiplexer (µmux) coupled to transition edge sensor (TES) bolometers that have been optimized for cosmic microwave background (CMB) observations. In a 64-channel demonstration, we show that the µmux produces a white, input referred current noise level of [Formula: see text] at -77 dB microwave probe tone power, which is well below expected fundamental detector and photon noise sources for a ground-based CMB-optimized bolometer. Operated with negligible photon loading, we measure [Formula: see text] in the TES-coupled channels biased at 65% of the sensor normal resistance. This noise level is consistent with that predicted from bolometer thermal fluctuation (i.e. phonon) noise. Furthermore, the power spectral density is white over a range of frequencies down to ~ 100 mHz, which enables CMB mapping on large angular scales that constrain the physics of inflation. Additionally, we report cross-talk measurements that indicate a level below 0.3%, which is less than the level of cross-talk from multiplexed readout systems in deployed CMB imagers. These measurements demonstrate the µmux as a viable readout technique for future CMB imaging instruments.

arXiv:1710.04326•Applied Physics Letters•Dec 11, 2017•61 citations

A prototype of 5-channel microwave SQUID multiplexer for primordial gravitational wave detection

Xianfeng Zhou, Zhi-Fa Feng, Min Li +10 more

Abstract Primordial gravitational waves (PGWs) can only be detected by measuring the B-mode polarization of the cosmic microwave background (CMB) and large-scale arrays based on superconducting transition-edge sensors (TES) are the detectors of the choice thanks to the background-limited sensitivity. Different multiplexing readout techniques have been developed to combine the signals from multiple detectors into a reduced number of readout channels. Microwave SQUID multiplexing (μMUX) has the highest multiplexing factor, suitable for large-scale TES array readout. We are developing μMUX chips to read out TES array for the detection of PGWs. We have designed and fabricated a prototype of a 5-channel μMUX chip consisting of distributed quarter-wavelength coplanar waveguide (CPW) resonators and radio-frequency superconducting quantum interference devices (RF SQUIDs). The measured quality factor of the CPW resonators working at 4.7-4.9 GHz is higher than 104. The maximum frequency shift is about 290 kHz on average, compatible with the resonator bandwidth (~380 kHz). The mean value of magnetic flux noise is 1.1 μ$\Phi_0 / \sqrt{\mathrm{Hz}} @ 5$ kHz, corresponding to a current noise of 40 $\mathrm{pA} / \sqrt{\mathrm{Hz}}$.

Chinese Physics B•Feb 12, 2026•1 citation

Development of a microwave SQUID multiplexer for superconducting transition-edge sensor bolometer arrays

Zhi-Fa Feng, Xian-Feng Zhou, M Y Li +10 more

Abstract A microwave SQUID multiplexer ( μ MUX) with a high multiplexing factor is a promising readout approach for large-scale superconducting transition-edge sensor (TES) bolometer arrays. This paper reports on the characteristics of 16-channel μ MUX prototype chips and a 60-channel readout module developed to read out TES bolometers for the Ali cosmic microwave background polarization telescope (AliCPT). We designed two different coupling structures between the resonator and the radio-frequency superconducting interference device: design A with a mutual inductance ( M T ) of 2.3 pH and design B with an M T of 6.5 pH. For design A, the mean resonator bandwidth ( Δ f BW ) and peak-to-peak frequency shift ( Δ f pp ) are approximately 610 kHz and 290 kHz, respectively. The measured mean open-loop current noise is less than 40 pA / Hz . Preliminary results indicate that crosstalk between adjacent channels is below 1% in our design A μ MUX chip. A measured channel with design B shows a Δ f BW of 586 kHz and a current noise of 33 pA / Hz , similar to the design A channels. In comparison, the Δ f pp of 803 kHz is much larger than the design A channels due to a larger M T . The readout module, consisting of two design A chips and two design B chips, shows 60 resonances, corresponding to a yield of 94%. In the future, we will place 32 design A channels within the same chip dimension to increase the channel density and build a larger readout module suitable for AliCPT TES arrays.

Superconductor Science and Technology•Sep 1, 2026•0 citations
Future cosmic microwave background (CMB) surveys will require an order of magnitude more detectors than are currently deployed in the most densely packed fielded experiments. This calls for a multiplexed readout capable of handling the increased integration complexity, heat load on the lowest temperature stages, and cost for such experiments. One choice of readout technology is direct current (DC) superconducting quantum interference device (SQUID)-based time-division multiplexing (TDM). This technology, along with transition-edge sensor (TES) detector technology, has been successfully deployed by multiple CMB experiments over the past decade. However, current experiments implementing TDM have not yet demonstrated the combination of multiplexing (MUX) factor, sampling rate, and noise performance at the scale of a next-generation experiment, such as CMB Stage 4 (CMB-S4). In order to meet these requirements, an advanced TDM architecture has been developed that features increased amplification of TES signals and increased bandwidth compared to previous MUX chip designs, as well as implementation of fully symmetric, differential circuits and hierarchical row addressing. We report on the first integration and noise characterization of this advanced TDM architecture with a prototype CMB-S4 dichroic detector wafer sensitive to the 90 and 150 GHz bands. Limitations of the legacy warm electronics used in this work preclude direct tests of the hierarchical MUX and fully differential signal paths; we instead focus on noise characterization at the SQUID and detector levels. Based on our measurements, the full system performance is projected to exceed CMB-S4 design requirements.
Abstract Direct-current superconducting quantum interference devices (dc-SQUIDs) are one of the most sensitive magnetic detectors. These sensors are extensively used in the readout of superconducting transition edge sensors (TESs), which are used for the detection of weak signals. A cosmic microwave background (CMB) polarization telescope operating in 22–48 GHz is currently under developing. The TESs calorimeter of the telescope will be readout by a time-division multiplexer SQUID readout system. We develop a two-stage dc-SQUID amplifier circuit, comprising an input-stage SQUID with 4 SQUID cells and a series SQUID array with 100 SQUID cells. This configuration has been shown to achieve extremely high signal gain while effectively controlling system noise. We assess the system noise at 300 mK in an adiabatic demagnetization refrigerator. The measured magnetic flux noise of the two-stage SQUID circuit system is approximately 0.3 μ Φ 0 / Hz at 10 kHz. The current noise equivalent to the input coil of input SQUID is about 2.4 pA / Hz . This result meets the low-noise readout requirements of the CMB TES and other applications with TES detectors.
The next generation of cryogenic CMB and submillimeter cameras under development require densely instrumented sensor arrays to meet their science goals. The readout of large numbers (~10,000-100,000 per camera) of sub-Kelvin sensors, for instance as proposed for the CMB-S4 experiment, will require substantial improvements in cold and warm readout techniques. To reduce the readout cost per sensor and integration complexity, efforts are presently focused on achieving higher multiplexing density while maintaining readout noise subdominant to intrinsic detector noise and presenting manageable thermal loads. Highly-multiplexed cold readout technologies in active development include Microwave Kinetic Inductance Sensors (MKIDs) and microwave rf-SQUIDs. Both exploit the high quality factors of superconducting microwave resonators to densely channelize sub-Kelvin sensors into the bandwidth of a microwave transmission line. In the case of microwave SQUID multiplexing, arrays of transition-edge sensors (TES) are multiplexed by coupling each TES to its own superconducting microwave resonator through an rf-SQUID. We present advancements in the development of a new warm readout system for microwave SQUID multiplexing, the SLAC Superconducting Microresonator RF electronics, or SMuRF, by adapting SLAC National Accelerator Laboratory's Advanced Telecommunications Computing Architecture (ATCA) FPGA Common Platform. SMuRF aims to read out 4000 microwave SQUID channels between 4 and 8 GHz per RF line. Each compact SMuRF system is built onto a single ATCA carrier blade. Daughter boards on the blade implement RF frequency-division multiplexing using FPGAs, fast DACs and ADCs, and an analog up- and down-conversion chain. The system reads out changes in flux in each resonator-coupled rf-SQUID by monitoring the change in the transmitted amplitude and frequency of RF tones produced at each resonator's fundamental frequency. The SMuRF system is unique in its ability to track each tone, minimizing the total RF power required to readout each resonator, thereby significantly reducing the linearity requirements on the cold and warm readout. Here, we present measurements of the readout noise and linearity of the first full SMuRF system, including a demonstration of closed-loop tone tracking on a 528 channel cryogenic microwave SQUID multiplexer. SMuRF is being explored as a potential readout solution for a number of future CMB projects including Simons Observatory, BICEP Array, CCAT-prime, Ali-CPT, and CMB-S4. In addition, parallel development of the platform is underway to adapt SMuRF to read out both MKID and fast X-ray TES calorimeter arrays.
Transition Edge Sensors (TESs) are highly sensitive cryogenic detectors widely used in astronomy, high-energy physics and nuclear radiation detection. As TES is increasingly deployed in large-scale arrays to improve sensitivity and effective collecting area, multiplexed readout becomes essential for reducing system complexity. Microwave SQUID multiplexing (μMUX) technology combining superconducting resonators with radio-frequency superconducting quantum interference devices (RF-SQUIDs), represents a state-of-the-art solution. In this work, a room-temperature readout prototype for TES μMUX readout was designed. The system features a scalable two-stage architecture, including a highly integrated, chassis-independent front-end signal processing module and back-end event-reconstruction module. A high-frequency-resolution frequency-comb signal generation method with real-time, per-tone frequency and phase tunability was developed. In addition, optimization of the firmware implementation effectively overcomes the computational-resource bottleneck of the Field Programmable Gate Array (FPGA). The prototype supports autonomous frequency sweeping, parameter diagnostics, and online event reconstruction. Self-test shows S 21 phase noise better than −110 dBc/Hz at −30 dBm, remaining stable with increasing channel count. Joint tests with a μMUX cryogenic system successfully captured the RF-SQUID response and achieved an equivalent noise current of 44 pA/√Hz referred to the TES, validating the prototype as a practical solution of the room-temperature system for TES μMUX readout.
Key performance characteristics are demonstrated for the microwave SQUID multiplexer (µmux) coupled to transition edge sensor (TES) bolometers that have been optimized for cosmic microwave background (CMB) observations. In a 64-channel demonstration, we show that the µmux produces a white, input referred current noise level of [Formula: see text] at -77 dB microwave probe tone power, which is well below expected fundamental detector and photon noise sources for a ground-based CMB-optimized bolometer. Operated with negligible photon loading, we measure [Formula: see text] in the TES-coupled channels biased at 65% of the sensor normal resistance. This noise level is consistent with that predicted from bolometer thermal fluctuation (i.e. phonon) noise. Furthermore, the power spectral density is white over a range of frequencies down to ~ 100 mHz, which enables CMB mapping on large angular scales that constrain the physics of inflation. Additionally, we report cross-talk measurements that indicate a level below 0.3%, which is less than the level of cross-talk from multiplexed readout systems in deployed CMB imagers. These measurements demonstrate the µmux as a viable readout technique for future CMB imaging instruments.
Abstract Primordial gravitational waves (PGWs) can only be detected by measuring the B-mode polarization of the cosmic microwave background (CMB) and large-scale arrays based on superconducting transition-edge sensors (TES) are the detectors of the choice thanks to the background-limited sensitivity. Different multiplexing readout techniques have been developed to combine the signals from multiple detectors into a reduced number of readout channels. Microwave SQUID multiplexing (μMUX) has the highest multiplexing factor, suitable for large-scale TES array readout. We are developing μMUX chips to read out TES array for the detection of PGWs. We have designed and fabricated a prototype of a 5-channel μMUX chip consisting of distributed quarter-wavelength coplanar waveguide (CPW) resonators and radio-frequency superconducting quantum interference devices (RF SQUIDs). The measured quality factor of the CPW resonators working at 4.7-4.9 GHz is higher than 104. The maximum frequency shift is about 290 kHz on average, compatible with the resonator bandwidth (~380 kHz). The mean value of magnetic flux noise is 1.1 μΦ0/Hz@5\Phi_0 / \sqrt{\mathrm{Hz}} @ 5Φ0​/Hz​@5 kHz, corresponding to a current noise of 40 pA/Hz\mathrm{pA} / \sqrt{\mathrm{Hz}}pA/Hz​.
Abstract A microwave SQUID multiplexer ( μ MUX) with a high multiplexing factor is a promising readout approach for large-scale superconducting transition-edge sensor (TES) bolometer arrays. This paper reports on the characteristics of 16-channel μ MUX prototype chips and a 60-channel readout module developed to read out TES bolometers for the Ali cosmic microwave background polarization telescope (AliCPT). We designed two different coupling structures between the resonator and the radio-frequency superconducting interference device: design A with a mutual inductance ( M T ) of 2.3 pH and design B with an M T of 6.5 pH. For design A, the mean resonator bandwidth ( Δ f BW ) and peak-to-peak frequency shift ( Δ f pp ) are approximately 610 kHz and 290 kHz, respectively. The measured mean open-loop current noise is less than 40 pA / Hz . Preliminary results indicate that crosstalk between adjacent channels is below 1% in our design A μ MUX chip. A measured channel with design B shows a Δ f BW of 586 kHz and a current noise of 33 pA / Hz , similar to the design A channels. In comparison, the Δ f pp of 803 kHz is much larger than the design A channels due to a larger M T . The readout module, consisting of two design A chips and two design B chips, shows 60 resonances, corresponding to a yield of 94%. In the future, we will place 32 design A channels within the same chip dimension to increase the channel density and build a larger readout module suitable for AliCPT TES arrays.