Development of Low-Noise Two-stage dc-SQUID for TES Detector Readout

Nan Li, Mengjie Song, Sixiao Hu, Wentao Wu, Songqing Liu, Tangchong Kuang, Yudong Gu, Xiangxiang Ren, Xufang Li, He Gao, Zhengwei Li, Fangjun Lu

Published Jan 27, 2026• 0 citations
arXivHTMLPDF

Abstract

Direct-current superconducting quantum interference devices (dc-SQUIDs) are one of the most sensitive magnetic detectors. These sensors are extensively used in the readout of superconducting transition edge sensors (TESs), which are used for the detection of weak signals. A cosmic microwave background (CMB) polarization telescope operating in 22-48 GHz is currently under developing. The TESs calorimeter of the telescope will be readout by a time-division multiplexer (TDM) SQUID readout system. We develop a two-stage dc-SQUID amplifier circuit, comprising an input-stage SQUID with 4 SQUID cells and a series SQUID array (SSA) with 100 SQUID cells. This configuration has been shown to achieve extremely high signal gain while effectively controlling system noise. We assess the system noise at $300$ $mK$ in an adiabatic demagnetisation refrigerator (ADR). The the measured magnetic flux noise of the two-stage SQUID circuit system is approximately $0.3$ $μΦ_{0}/\sqrt{Hz}$ at $10$ $kHz$. The current noise equivalent to the input coil of input SQUID is about $2.4$ $pA/\sqrt{Hz}$. This result meets the low-noise readout requirements of the CMB TES and other applications with TES detectors.

DOI
10.48550/arxiv.2601.19565

Related papers

Development of low-noise two-stage dc-SQUID for TES detector readout

Nan Li, Mengjie Song, Sixiao Hu +9 more

Abstract Direct-current superconducting quantum interference devices (dc-SQUIDs) are one of the most sensitive magnetic detectors. These sensors are extensively used in the readout of superconducting transition edge sensors (TESs), which are used for the detection of weak signals. A cosmic microwave background (CMB) polarization telescope operating in 22–48 GHz is currently under developing. The TESs calorimeter of the telescope will be readout by a time-division multiplexer SQUID readout system. We develop a two-stage dc-SQUID amplifier circuit, comprising an input-stage SQUID with 4 SQUID cells and a series SQUID array with 100 SQUID cells. This configuration has been shown to achieve extremely high signal gain while effectively controlling system noise. We assess the system noise at 300 mK in an adiabatic demagnetization refrigerator. The measured magnetic flux noise of the two-stage SQUID circuit system is approximately 0.3 μ Φ 0 / Hz at 10 kHz. The current noise equivalent to the input coil of input SQUID is about 2.4 pA / Hz . This result meets the low-noise readout requirements of the CMB TES and other applications with TES detectors.

Superconductor Science and Technology•Apr 1, 2026•0 citations

Development of second-order gradient DC SQUIDs for the readout of superconducting TES detectors

Z. F. Feng, Xuefeng Zhou, Q. X. Ma +12 more

Superconducting transition-edge sensors (TESs) are highly sensitive detectors, can detect electromagnetic wave radiations from millimeter/submillimeter, optical to x/γ rays, suitable for astrophysics, quantum information, and biosensing. Direct current superconducting quantum interference devices (DC SQUIDs) are the detector of choice for TES readout, thanks to their low noise, low impedance, and low power dissipation. In this work, we designed the DC SQUID with a second-order gradient structure, which can effectively mitigate the effect of external magnetic flux. We optimized the fabrication process and successfully fabricated the high-performance DC SQUID with Nb/Al-AlOx/Nb Josephson junctions (critical current density: JC~1μA/μm2). The properties of the fabricated DC SQUID were in good agreement with the simulation results. Meanwhile, the measured flux noise was 6 μΦ0/√Hz, corresponding to a current noise of 100 pA/√Hz. Furthermore, we demonstrated the capability of the DC SQUID to read out the TES detector, including I-V curves, photon pulse response, and noise performance.

Infrared, Millimeter-Wave, and Terahertz Technologies•Nov 19, 2025•0 citations

Development of series SQUID array with on-chip filter for TES detector

Wentao Wu, Zhirong Lin, Zhi Ni +10 more

A cold preamplifier based on superconducting quantum interference devices (SQUIDs) is currently the preferred readout technology for the low-noise transition edge sensor (TES). In this work, we have designed and fabricated a series SQUID array (SSA) amplifier for the TES detector readout circuit. In this SSA amplifier, each SQUID cell is composed of a first-order gradiometer formed using two equally large square washers, and an on-chip low pass filter (LPF) as a radio-frequency (RF) choke has been developed to reduce the Josephson oscillation interference between individual SQUID cells. In addition, a highly symmetric layout has been designed carefully to provide a fully consistent embedded electromagnetic environment and achieve coherent flux operation. The measured results show smooth V–Φ characteristics and a swing voltage that increases linearly with increasing SQUID cell number N. A white flux noise level as low as 0.28 μ Φ 0/Hz1/2 is achieved at 0.1 K, corresponding to a low current noise level of 7 pA/Hz1/2. We analyze the measured noise contribution at mK-scale temperatures and find that the dominant noise derives from a combination of the SSA intrinsic noise and the equivalent current noise of the room temperature electronics.

Chinese Physics B•Sep 30, 2021•7 citations

Sensitivity enhancement of Quantum Design dc superconducting quantum interference devices in two-stage configuration

R. Mezzena, Andrea Vinante, P. Falferi +5 more

The energy sensitivity of a direct current (dc) superconducting quantum interference device (SQUID) can be improved if it is operated in a two-stage configuration. Employing this technique, a commercial dc SQUID system was modified and made competitive with other sensors especially designed for very low noise applications. We report the noise measurements performed in the temperature range 4.2 K–25 mK. At 4.2 K, the coupled energy sensitivity obtained with the two-stage dc SQUID was approximately ten times better than with a conventional readout electronics. The noise energy decreases linearly until approximately 300 mK, in good agreement with theoretical previsions. At lower temperature the hot-electron effect produces a saturation and the best energy sensitivity measured with open input coil is 35 ℏ.

Review of Scientific Instruments•Sep 1, 2001•31 citations

Low-noise ultra-high-speed dc SQUID readout electronics

D. Drung, Colmar Hinnrichs, H.-J. Barthelmess

User-friendly ultra-high-speed readout electronics for dc superconducting quantum interference devices (SQUIDs) are presented. To maximize the system bandwidth, the SQUID is directly read out without flux modulation. A composite preamplifier is used consisting of a slow dc amplifier in parallel with a fast ac amplifier. In this way, excellent dc precision and a high amplifier bandwidth of 50 MHz are achieved, simultaneously. A virtual 50 Ω amplifier input resistance with negligible excess noise is realized by active shunting, i.e., by applying feedback from preamplifier output to input via a high resistance. The white voltage and current noise levels are 0.33 nV Hz −1 and 2.6 pA Hz −1/2 , respectively. The electronics is fully computer controlled via a microcontroller integrated into the flux-locked loop (FLL) board. Easy-to-use software makes the various electronic settings accessible. A wide bias voltage range of 1.3 mV enables the readout of series SQUID arrays. Furthermore, additional current sources allow the operation of two-stage SQUIDs or transition edge sensors. The electronics was tested using various SQUIDs with input inductances between 30 nH and 1.5 µH. Typically, the maximum FLL bandwidth was 20 MHz, which is close to the theoretical limit given by transmission line delay within the FLL. Slew rates of up to 4.6 Φ 0 µs −1 were achieved with series SQUID arrays. Current noise levels as low as 0.47 pA Hz −1/2 and coupled energy sensitivities between 90 h and 500 h were measured at 4.2 K, where h is the Planck constant. The noise did not degrade when the system bandwidth was increased to the maximum value of about 20 MHz. With a two-stage set-up, intrinsic white energy sensitivities of 30 h and 2.3 h were measured at 4.2 and 0.3 K, respectively.

Superconductor Science and Technology•Feb 27, 2006•72 citations

Strongly coupled, low noise dc-SQUID amplifiers

J. Pleikies

The dc Superconducting Quantum Interference Device (dc-SQUID) is one of the most sensitive magnetic field sensors available. In this thesis we concentrate on its application as an amplifier. In this configuration, an input circuit of interest can be connected by means of a coupling coil. The intended application of our developed low-Tc SQUID amplifiers is the readout of the first spherical gravitational wave antenna MiniGRAIL. Using small-signal analysis as well as numerical simulations, we study the achievable signal-to-noise ratio of such sensors in practical measurements. Published theories and studies could be extended. Some interesting points treated are the influence of the often used negative feedback (flux-locked loop), an altered input impedance of the SQUID amplifier and the influence of back-action noise, which directly affects the object of interest. The altered operation of the SQUID due to the presence of the input circuit is studied in numerical experiments. Another important issue, the influence of integrated input coils on the dynamics of SQUIDs, is investigated theoretically and experimentally. The performance of our developed sensors is compared to numerical simulations on detailed models. The results give insights into the behavior, design and usage of dc-SQUIDs with integrated coils. For a SQUID with input inductances of 1.5 μH we reached a good coupled energy sensitivity of about 170 ¯h in a dilution refrigerator. Furthermore, we investigated the hot-electron effect. This effect typically limits the sensitivity of superconducting electronics at sub-Kelvin bath temperatures due to a weakened electron-phonon coupling. We performed heating experiments on thin-film resistors which are similar to the shunt resistors of the Josephson junctions used in our sensors. The suppression of the hot-electron effect via electronic thermal transport to attached cooling fins is investigated both experimentally, theoretically and numerically. The numerical technique turns out to be a useful tool for the thermal design of superconducting electronics.

•Apr 1, 2009•0 citations
Direct-current superconducting quantum interference devices (dc-SQUIDs) are one of the most sensitive magnetic detectors. These sensors are extensively used in the readout of superconducting transition edge sensors (TESs), which are used for the detection of weak signals. A cosmic microwave background (CMB) polarization telescope operating in 22-48 GHz is currently under developing. The TESs calorimeter of the telescope will be readout by a time-division multiplexer (TDM) SQUID readout system. We develop a two-stage dc-SQUID amplifier circuit, comprising an input-stage SQUID with 4 SQUID cells and a series SQUID array (SSA) with 100 SQUID cells. This configuration has been shown to achieve extremely high signal gain while effectively controlling system noise. We assess the system noise at 300300300 mKmKmK in an adiabatic demagnetisation refrigerator (ADR). The the measured magnetic flux noise of the two-stage SQUID circuit system is approximately 0.30.30.3 μΦ0/HzμΦ_{0}/\sqrt{Hz}μΦ0​/Hz​ at 101010 kHzkHzkHz. The current noise equivalent to the input coil of input SQUID is about 2.42.42.4 pA/HzpA/\sqrt{Hz}pA/Hz​. This result meets the low-noise readout requirements of the CMB TES and other applications with TES detectors.
Abstract Direct-current superconducting quantum interference devices (dc-SQUIDs) are one of the most sensitive magnetic detectors. These sensors are extensively used in the readout of superconducting transition edge sensors (TESs), which are used for the detection of weak signals. A cosmic microwave background (CMB) polarization telescope operating in 22–48 GHz is currently under developing. The TESs calorimeter of the telescope will be readout by a time-division multiplexer SQUID readout system. We develop a two-stage dc-SQUID amplifier circuit, comprising an input-stage SQUID with 4 SQUID cells and a series SQUID array with 100 SQUID cells. This configuration has been shown to achieve extremely high signal gain while effectively controlling system noise. We assess the system noise at 300 mK in an adiabatic demagnetization refrigerator. The measured magnetic flux noise of the two-stage SQUID circuit system is approximately 0.3 μ Φ 0 / Hz at 10 kHz. The current noise equivalent to the input coil of input SQUID is about 2.4 pA / Hz . This result meets the low-noise readout requirements of the CMB TES and other applications with TES detectors.
Superconducting transition-edge sensors (TESs) are highly sensitive detectors, can detect electromagnetic wave radiations from millimeter/submillimeter, optical to x/γ rays, suitable for astrophysics, quantum information, and biosensing. Direct current superconducting quantum interference devices (DC SQUIDs) are the detector of choice for TES readout, thanks to their low noise, low impedance, and low power dissipation. In this work, we designed the DC SQUID with a second-order gradient structure, which can effectively mitigate the effect of external magnetic flux. We optimized the fabrication process and successfully fabricated the high-performance DC SQUID with Nb/Al-AlOx/Nb Josephson junctions (critical current density: JC~1μA/μm2). The properties of the fabricated DC SQUID were in good agreement with the simulation results. Meanwhile, the measured flux noise was 6 μΦ0/√Hz, corresponding to a current noise of 100 pA/√Hz. Furthermore, we demonstrated the capability of the DC SQUID to read out the TES detector, including I-V curves, photon pulse response, and noise performance.
A cold preamplifier based on superconducting quantum interference devices (SQUIDs) is currently the preferred readout technology for the low-noise transition edge sensor (TES). In this work, we have designed and fabricated a series SQUID array (SSA) amplifier for the TES detector readout circuit. In this SSA amplifier, each SQUID cell is composed of a first-order gradiometer formed using two equally large square washers, and an on-chip low pass filter (LPF) as a radio-frequency (RF) choke has been developed to reduce the Josephson oscillation interference between individual SQUID cells. In addition, a highly symmetric layout has been designed carefully to provide a fully consistent embedded electromagnetic environment and achieve coherent flux operation. The measured results show smooth V–Φ characteristics and a swing voltage that increases linearly with increasing SQUID cell number N. A white flux noise level as low as 0.28 μ Φ 0/Hz1/2 is achieved at 0.1 K, corresponding to a low current noise level of 7 pA/Hz1/2. We analyze the measured noise contribution at mK-scale temperatures and find that the dominant noise derives from a combination of the SSA intrinsic noise and the equivalent current noise of the room temperature electronics.
The energy sensitivity of a direct current (dc) superconducting quantum interference device (SQUID) can be improved if it is operated in a two-stage configuration. Employing this technique, a commercial dc SQUID system was modified and made competitive with other sensors especially designed for very low noise applications. We report the noise measurements performed in the temperature range 4.2 K–25 mK. At 4.2 K, the coupled energy sensitivity obtained with the two-stage dc SQUID was approximately ten times better than with a conventional readout electronics. The noise energy decreases linearly until approximately 300 mK, in good agreement with theoretical previsions. At lower temperature the hot-electron effect produces a saturation and the best energy sensitivity measured with open input coil is 35 ℏ.
User-friendly ultra-high-speed readout electronics for dc superconducting quantum interference devices (SQUIDs) are presented. To maximize the system bandwidth, the SQUID is directly read out without flux modulation. A composite preamplifier is used consisting of a slow dc amplifier in parallel with a fast ac amplifier. In this way, excellent dc precision and a high amplifier bandwidth of 50 MHz are achieved, simultaneously. A virtual 50 Ω amplifier input resistance with negligible excess noise is realized by active shunting, i.e., by applying feedback from preamplifier output to input via a high resistance. The white voltage and current noise levels are 0.33 nV Hz −1 and 2.6 pA Hz −1/2 , respectively. The electronics is fully computer controlled via a microcontroller integrated into the flux-locked loop (FLL) board. Easy-to-use software makes the various electronic settings accessible. A wide bias voltage range of 1.3 mV enables the readout of series SQUID arrays. Furthermore, additional current sources allow the operation of two-stage SQUIDs or transition edge sensors. The electronics was tested using various SQUIDs with input inductances between 30 nH and 1.5 µH. Typically, the maximum FLL bandwidth was 20 MHz, which is close to the theoretical limit given by transmission line delay within the FLL. Slew rates of up to 4.6 Φ 0 µs −1 were achieved with series SQUID arrays. Current noise levels as low as 0.47 pA Hz −1/2 and coupled energy sensitivities between 90 h and 500 h were measured at 4.2 K, where h is the Planck constant. The noise did not degrade when the system bandwidth was increased to the maximum value of about 20 MHz. With a two-stage set-up, intrinsic white energy sensitivities of 30 h and 2.3 h were measured at 4.2 and 0.3 K, respectively.
The dc Superconducting Quantum Interference Device (dc-SQUID) is one of the most sensitive magnetic field sensors available. In this thesis we concentrate on its application as an amplifier. In this configuration, an input circuit of interest can be connected by means of a coupling coil. The intended application of our developed low-Tc SQUID amplifiers is the readout of the first spherical gravitational wave antenna MiniGRAIL. Using small-signal analysis as well as numerical simulations, we study the achievable signal-to-noise ratio of such sensors in practical measurements. Published theories and studies could be extended. Some interesting points treated are the influence of the often used negative feedback (flux-locked loop), an altered input impedance of the SQUID amplifier and the influence of back-action noise, which directly affects the object of interest. The altered operation of the SQUID due to the presence of the input circuit is studied in numerical experiments. Another important issue, the influence of integrated input coils on the dynamics of SQUIDs, is investigated theoretically and experimentally. The performance of our developed sensors is compared to numerical simulations on detailed models. The results give insights into the behavior, design and usage of dc-SQUIDs with integrated coils. For a SQUID with input inductances of 1.5 μH we reached a good coupled energy sensitivity of about 170 ¯h in a dilution refrigerator. Furthermore, we investigated the hot-electron effect. This effect typically limits the sensitivity of superconducting electronics at sub-Kelvin bath temperatures due to a weakened electron-phonon coupling. We performed heating experiments on thin-film resistors which are similar to the shunt resistors of the Josephson junctions used in our sensors. The suppression of the hot-electron effect via electronic thermal transport to attached cooling fins is investigated both experimentally, theoretically and numerically. The numerical technique turns out to be a useful tool for the thermal design of superconducting electronics.