APS Open Science
Atomic free-spin-precession magnetometer for biomagnetic measurements in Earth-range magnetic fields
Philipp Neufeld, Janine Riedrich‐Möller, Tino Fuchs, Dmitry Budker
Abstract
We present an implementation of an atomic magnetometer based on free spin precession of optically pumped Rb 87 atoms. The design features a microfabricated vapor cell with an effective volume of 7.1 mm 3 containing isotopically enriched Rb 87 and nitrogen buffer gas. The magnetometer is designed to operate in the Earth-field range, exhibiting a magnetic noise floor of about 147 fT / Hz at field strengths comparable to Earth's magnetic field, i.e., around 50 μ T . This is in close agreement with the Cramér-Rao lower bound of 118 fT / Hz . The good sensitivity as well as the high dynamic range enables a wide range of applications, including magnetocardiography and geomagnetic measurements.