arXiv:1910.01768 · Journal of Applied Physics

Subpicotesla scalar atomic magnetometer with a microfabricated cell

Rui Zhang, Terry Dyer, Nathan Brockie, Roozbeh Parsa, Rahul Mhaskar

Published Sep 26, 2019• 17 citations
arXivHTMLPDF

Abstract

We demonstrated a scalar atomic magnetometer using a microfabricated Cs vapor cell. The atomic spin precession is driven by an amplitude-modulated circularly-polarized pump laser resonant on the D1 transition of Cs atoms and detected by an off-resonant linearly-polarized probe laser using a balanced polarimeter setup. Under a magnetic field with amplitude in the Earth's magnetic field range, the magnetometer in the gradiometer mode can reach sensitivities below 150fT/Hz, which shows that the magnetometer by itself can achieve sub-100fT/Hz sensitivities. In addition to its high sensitivity, the magnetometer has a bandwidth close to 1 kHz due to the broad magnetic resonance inside the small vapor cell. Our experiment suggests the feasibility of a portable low-power and high-performance magnetometer which can be operated in the Earth's magnetic field. Such a device will greatly reduce the restrictions on the operating environment and expand the range of applications for atomic magnetometers, such as detection of nuclear magnetic resonance in low magnetic fields.

DOI
10.1063/1.5113520

Related papers

Subpicotesla scalar atomic magnetometer with a microfabricated cell

Rui Zhang, T. Dyer, N. L. Brockie +2 more

We demonstrated a scalar atomic magnetometer using a microfabricated Cs vapor cell. The atomic spin precession is driven by an amplitude-modulated circularly-polarized pump laser resonant on the D1 transition of Cs atoms and detected by an off-resonant linearly-polarized probe laser using a balanced polarimeter setup. Under a magnetic field with amplitude in the Earth's magnetic field range, the magnetometer in the gradiometer mode can reach sensitivities below 150fT/√Hz, which shows that the magnetometer by itself can achieve sub-100fT/√Hz sensitivities. In addition to its high sensitivity, the magnetometer has a bandwidth close to 1 kHz due to the broad magnetic resonance inside the small vapor cell. Our experiment suggests the feasibility of a portable low-power and high-performance magnetometer which can be operated in the Earth's magnetic field. Such a device will greatly reduce the restrictions on the operating environment and expand the range of applications for atomic magnetometers, such as detection of nuclear magnetic resonance in low magnetic fields

•Sep 28, 2019•1 citation

Pulsed operation of a miniature scalar optically pumped magnetometer

Vladislav P. Gerginov, Sean Krzyzewski, Svenja A. Knappe

A scalar magnetic field sensor based on a millimeter-size Rb87 vapor cell is described. The magnetometer uses nearly copropagating pump and probe laser beams, amplitude modulation of the pump beam, and detection through monitoring the polarization rotation of the detuned probe beam. The circularly polarized pump laser resonantly drives a spin precession in the alkali atoms at the Larmor frequency. A modulation signal on the probe laser polarization is detected with a lock-in amplifier. Since the Larmor precession is driven all-optically, potential cross talk between sensors is minimized. And since the pump light is turned off during most of the precession cycle, large offsets of the resonance, typically present in a single-beam Bell–Bloom scheme, are avoided. At the same time, relatively high sensitivities can be reached even in millimeter-size vapor cells: The magnetometer achieves a sensitivity of 1 pT/Hz1/2 in a sensitive volume of 16 mm3, limited by environmental noise. When a gradiometer configuration is used to cancel the environmental noise, the magnetometer sensitivity reaches 300 fT/Hz1/2. We systematically study the dependence of the magnetometer performance on the optical duty cycles of the pump light and find that better performance is achieved with shorter duty cycles, with the highest values measured at 1.25% duty cycle.

Journal of the Optical Society of America B•Jun 15, 2017•57 citations

Atomic free-spin-precession magnetometer for biomagnetic measurements in Earth-range magnetic fields

Philipp Neufeld, Janine Riedrich‐Möller, Tino Fuchs +1 more

We present an implementation of an atomic magnetometer based on free spin precession of optically pumped Rb 87 atoms. The design features a microfabricated vapor cell with an effective volume of 7.1 mm 3 containing isotopically enriched Rb 87 and nitrogen buffer gas. The magnetometer is designed to operate in the Earth-field range, exhibiting a magnetic noise floor of about 147 fT / Hz at field strengths comparable to Earth's magnetic field, i.e., around 50 μ T . This is in close agreement with the Cramér-Rao lower bound of 118 fT / Hz . The good sensitivity as well as the high dynamic range enables a wide range of applications, including magnetocardiography and geomagnetic measurements.

APS Open Science•Jun 8, 2026•0 citations

Vector Atomic Magnetometer with Free Induction Decay Detection Based on a Microfabricated Vapor Cell

Pengbo Jiang, Qi Li, Jianan Qin +1 more

Atomic magnetometers are highly sensitive instruments widely used for measurements of weak magnetic field. Extracting vector information while maintaining high-precision scalar detection has become the trend in atomic magnetometer development. We introduce a vector atomic magnetometer containing a 5 mm-thick microfabricated vapor cell operating in free-induction-decay mode. By employing orthogonal modulation techniques, the system achieves high-precision in-plane vector magnetic field measurements. The high-precision vector magnetic field measurements are demonstrated in the x–z plane. The sensitivity of the total field detection in the miniaturized atomic magnetometer is 30 pT·Hz−1/2 @11 µT. The average angular error of the decoupled measurement is as low as 4.7 mrad @7.6 µT for vector magnetic fields, providing a new approach for vector magnetic field measurement in miniaturized atomic magnetometers.

Micromachines•Dec 30, 2024•2 citations

High-sensitivity operation of a single-beam atomic magnetometer for three-axis magnetic field measurement

Junjian Tang, Yueyang Zhai, Cao Li +6 more

We demonstrate a single-beam atomic magnetometer (AM) capable of measuring a three-axis magnetic field with high-sensitivity, achieved by applying a small DC offset field and a high frequency modulation field. To satisfy the miniaturization demand of AMs, an elliptically polarized light detuned by 50 GHz from the resonance transition center is employed. The circularly polarized component is used to polarize the alkali-metal atoms, while the linearly polarized light is used to detect the dynamics of the polarized spin under a magnetic field. Based on theoretical analysis, parameters that significantly affect the performance are optimized, and a sensitivity of 20 fT/Hz 1/2 in x -axis, 25 fT/Hz 1/2 in y -axis, 30 fT/Hz 1/2 in z -axis is achieved with a miniature 4 × 4 × 4 mm 87 Rb vapor cell. Moreover, we also verify that the operation principle of AMs can be used to null background magnetic fields in-situ with isotropic compensation resolution of 6.7 pT, which provides an effectively precise method for zeroing ambient magnetic field. The high-sensitivity operating of an elliptically-polarized-laser-based magnetometer provides prospective futures for constructing a compact, low-cost AM, which is particularly applicable for non-invasive bio-magnetic imaging such as array-based magnetoencephalography (MEG) and magnetocardiography (MCG).

Optics Express•May 3, 2021•123 citations

Femtotesla atomic magnetometry in a microfabricated vapor cell

W. C. Griffith, Svenja A. Knappe, John E. Kitching

We describe an optically pumped 87Rb magnetometer with 5 fT/Hz(1/2) sensitivity when operated in the spin-exchange relaxation free (SERF) regime. The magnetometer uses a microfabricated vapor cell consisting of a cavity etched in a 1 mm thick silicon wafer with anodically bonded Pyrex windows. The measurement volume of the magnetometer is 1 mm3, defined by the overlap region of a circularly polarized pump laser and a linearly polarized probe laser, both operated near 795 nm. Sensitivity limitations unique to the use of microfabricated cells are discussed.

APS•Mar 1, 2010•0 citations
We demonstrated a scalar atomic magnetometer using a microfabricated Cs vapor cell. The atomic spin precession is driven by an amplitude-modulated circularly-polarized pump laser resonant on the D1 transition of Cs atoms and detected by an off-resonant linearly-polarized probe laser using a balanced polarimeter setup. Under a magnetic field with amplitude in the Earth's magnetic field range, the magnetometer in the gradiometer mode can reach sensitivities below 150fT/Hz, which shows that the magnetometer by itself can achieve sub-100fT/Hz sensitivities. In addition to its high sensitivity, the magnetometer has a bandwidth close to 1 kHz due to the broad magnetic resonance inside the small vapor cell. Our experiment suggests the feasibility of a portable low-power and high-performance magnetometer which can be operated in the Earth's magnetic field. Such a device will greatly reduce the restrictions on the operating environment and expand the range of applications for atomic magnetometers, such as detection of nuclear magnetic resonance in low magnetic fields.
We demonstrated a scalar atomic magnetometer using a microfabricated Cs vapor cell. The atomic spin precession is driven by an amplitude-modulated circularly-polarized pump laser resonant on the D1 transition of Cs atoms and detected by an off-resonant linearly-polarized probe laser using a balanced polarimeter setup. Under a magnetic field with amplitude in the Earth's magnetic field range, the magnetometer in the gradiometer mode can reach sensitivities below 150fT/√Hz, which shows that the magnetometer by itself can achieve sub-100fT/√Hz sensitivities. In addition to its high sensitivity, the magnetometer has a bandwidth close to 1 kHz due to the broad magnetic resonance inside the small vapor cell. Our experiment suggests the feasibility of a portable low-power and high-performance magnetometer which can be operated in the Earth's magnetic field. Such a device will greatly reduce the restrictions on the operating environment and expand the range of applications for atomic magnetometers, such as detection of nuclear magnetic resonance in low magnetic fields
A scalar magnetic field sensor based on a millimeter-size Rb87 vapor cell is described. The magnetometer uses nearly copropagating pump and probe laser beams, amplitude modulation of the pump beam, and detection through monitoring the polarization rotation of the detuned probe beam. The circularly polarized pump laser resonantly drives a spin precession in the alkali atoms at the Larmor frequency. A modulation signal on the probe laser polarization is detected with a lock-in amplifier. Since the Larmor precession is driven all-optically, potential cross talk between sensors is minimized. And since the pump light is turned off during most of the precession cycle, large offsets of the resonance, typically present in a single-beam Bell–Bloom scheme, are avoided. At the same time, relatively high sensitivities can be reached even in millimeter-size vapor cells: The magnetometer achieves a sensitivity of 1 pT/Hz1/2 in a sensitive volume of 16 mm3, limited by environmental noise. When a gradiometer configuration is used to cancel the environmental noise, the magnetometer sensitivity reaches 300 fT/Hz1/2. We systematically study the dependence of the magnetometer performance on the optical duty cycles of the pump light and find that better performance is achieved with shorter duty cycles, with the highest values measured at 1.25% duty cycle.
We present an implementation of an atomic magnetometer based on free spin precession of optically pumped Rb 87 atoms. The design features a microfabricated vapor cell with an effective volume of 7.1 mm 3 containing isotopically enriched Rb 87 and nitrogen buffer gas. The magnetometer is designed to operate in the Earth-field range, exhibiting a magnetic noise floor of about 147 fT / Hz at field strengths comparable to Earth's magnetic field, i.e., around 50 μ T . This is in close agreement with the Cramér-Rao lower bound of 118 fT / Hz . The good sensitivity as well as the high dynamic range enables a wide range of applications, including magnetocardiography and geomagnetic measurements.
Atomic magnetometers are highly sensitive instruments widely used for measurements of weak magnetic field. Extracting vector information while maintaining high-precision scalar detection has become the trend in atomic magnetometer development. We introduce a vector atomic magnetometer containing a 5 mm-thick microfabricated vapor cell operating in free-induction-decay mode. By employing orthogonal modulation techniques, the system achieves high-precision in-plane vector magnetic field measurements. The high-precision vector magnetic field measurements are demonstrated in the x–z plane. The sensitivity of the total field detection in the miniaturized atomic magnetometer is 30 pT·Hz−1/2 @11 µT. The average angular error of the decoupled measurement is as low as 4.7 mrad @7.6 µT for vector magnetic fields, providing a new approach for vector magnetic field measurement in miniaturized atomic magnetometers.
We demonstrate a single-beam atomic magnetometer (AM) capable of measuring a three-axis magnetic field with high-sensitivity, achieved by applying a small DC offset field and a high frequency modulation field. To satisfy the miniaturization demand of AMs, an elliptically polarized light detuned by 50 GHz from the resonance transition center is employed. The circularly polarized component is used to polarize the alkali-metal atoms, while the linearly polarized light is used to detect the dynamics of the polarized spin under a magnetic field. Based on theoretical analysis, parameters that significantly affect the performance are optimized, and a sensitivity of 20 fT/Hz 1/2 in x -axis, 25 fT/Hz 1/2 in y -axis, 30 fT/Hz 1/2 in z -axis is achieved with a miniature 4 × 4 × 4 mm 87 Rb vapor cell. Moreover, we also verify that the operation principle of AMs can be used to null background magnetic fields in-situ with isotropic compensation resolution of 6.7 pT, which provides an effectively precise method for zeroing ambient magnetic field. The high-sensitivity operating of an elliptically-polarized-laser-based magnetometer provides prospective futures for constructing a compact, low-cost AM, which is particularly applicable for non-invasive bio-magnetic imaging such as array-based magnetoencephalography (MEG) and magnetocardiography (MCG).
We describe an optically pumped 87Rb magnetometer with 5 fT/Hz(1/2) sensitivity when operated in the spin-exchange relaxation free (SERF) regime. The magnetometer uses a microfabricated vapor cell consisting of a cavity etched in a 1 mm thick silicon wafer with anodically bonded Pyrex windows. The measurement volume of the magnetometer is 1 mm3, defined by the overlap region of a circularly polarized pump laser and a linearly polarized probe laser, both operated near 795 nm. Sensitivity limitations unique to the use of microfabricated cells are discussed.