Optimally detuned parametric amplification amplifies a signal in a resonator that is driven off-resonance, with respect to a signal mode, using a far-detuned pump. This pump establishes a parametric drive strength, and is "far-detuned" in that its detuning from the signal mode is greater than the drive strength. The amplitude and frequency of the pump are chosen so that the eigenfrequency of the resulting Bogoliobov mode matches a photonic loss rate of the Bogoliobov mode. In this case, a signal coupled into the Bogoliobov mode will be amplified with a gain that is broader and flatter than that achieved with conventional parametric amplification, and is not limited by a gain-bandwidth product. Optimally detuned parametric amplification may be used for degenerate or non-degenerate parametric amplification, and may be used to amplify microwaves, light, electronic signals, acoustic waves, or any other type of signal that can be amplified using conventional parametric amplification.
Optimally detuned parametric amplification amplifies a signal in a resonator that is driven off-resonance, with respect to a signal mode, using a far-detuned pump. This pump establishes a parametric drive strength, and is "far-detuned" in that its detuning from the signal mode is greater than the drive strength. The amplitude and frequency of the pump are chosen so that the eigenfrequency of the resulting Bogoliobov mode matches a photonic loss rate of the Bogoliobov mode. In this case, a signal coupled into the Bogoliobov mode will be amplified with a gain that is broader and flatter than that achieved with conventional parametric amplification, and is not limited by a gain-bandwidth product. Optimally detuned parametric amplification may be used for degenerate or non-degenerate parametric amplification, and may be used to amplify microwaves, light, electronic signals, acoustic waves, or any other type of signal that can be amplified using conventional parametric amplification.
Optimally detuned parametric amplification amplifies a signal in a resonator that is driven off-resonance, with respect to a signal mode, using a far-detuned pump. This pump establishes a parametric drive strength, and is "far-detuned" in that its detuning from the signal mode is greater than the drive strength. The amplitude and frequency of the pump are chosen so that the eigenfrequency of the resulting Bogoliobov mode matches a photonic loss rate of the Bogoliobov mode. In this case, a signal coupled into the Bogoliobov mode will be amplified with a gain that is broader and flatter than that achieved with conventional parametric amplification, and is not limited by a gain-bandwidth product. Optimally detuned parametric amplification may be used for degenerate or non-degenerate parametric amplification, and may be used to amplify microwaves, light, electronic signals, acoustic waves, or any other type of signal that can be amplified using conventional parametric amplification.
A quantum-statistical treatment of degenerate (single-mode) parametric amplification is given in which the pump is allowed to have time-dependent amplitude and phase. This relaxes earlier restrictions of a constant pump in exact resonance with the signal. Solutions are obtained for the case where the ratio of the time derivative of the pump phase to the coupling strength between pump and signal is constant. This includes the special case of simple offresonance, where the pump has a constant frequency differing from twice the signal frequency by a given amount (and has constant amplitude). The Wigner distribution for the signal mode is obtained (the P distribution does not in general exist as a well-defined function beyond a finite time interval for this process) and is used to determine the time development of the expectation values of various field operators of interest, such as field strengths and fluctuations. A critical point exists in the solution for the photon annihilation operator such that the behavior of the solution and the resulting quantities which it determines is divided into an exponential region and an oscillatory region. The critical point defines, from the expectation value for the photon number, the condition for amplification. For the case of simple off-resonance, this gives the frequency range of amplification. A calculation without using the rotating-wave approximation is given in the Appendix which shows that, to first order, the same range is obtained as when the approximation is used. The effect of damping is given, showing, e.g., how it slows the growth rate of the signal (in the region of amplification) and how it narrows the frequency range of amplification. The effect of a time-dependent pump (and damping) on the breakdown of the P distribution is also described.
Superconducting resonator parametric amplifiers are potentially important components for a wide variety of fundamental physics experiments and utilitarian applications. We propose and realise an operating scheme that achieves amplification through the use of non-degenerate pumps, which addresses two key challenges in the design of parametric amplifiers: non-continuous gain across the amplification band and pump tone removal. We have experimentally demonstrated the non-degenerate pumping scheme using a half-wave resonator amplifier based on NbN thin-film, and measured a peak gain of 26 dB and 3-dB bandwidth of 0.5 MHz. The two non-degenerate pump tones were positioned ∼10 ∼ 10 bandwidths above and below the frequency at which peak gain occurs. We have found the non-degenerate pumping scheme to be more stable compared to the usual degenerate pumping scheme in terms of gain drift over time, by a factor of 4. This scheme also retains the usual flexibility of NbN resonator parametric amplifiers in terms of reliable amplification in a ∼4 ∼ 4 K environment, and is suitable for cross-harmonic amplification. The use of pump tones at different frequencies allows phase-sensitive amplification when the signal tone is degenerate with the idler tone. A gain of 23 dB and squeezing ratio of 6 dB were measured.
This version develops a preregisterable and falsifiable experimental framework for investi-gating parametric optical amplification of weak biomedical signals.The framework explicitly distinguishes spontaneous parametric down-conversion fromseeded parametric amplification and treats the latter as the primary amplification mechanism.The signal path is modeled asweak optical input → parametric amplifier → loss/filtering → detector → statistical inference.The theoretical model is based on a two-mode Bogoliubov transformation,aˆs,out = uaˆs,in + vaˆ†i,in,with|u|2 − |v|2 = 1for the ideal lossless case.The framework separately models amplifier gain, quantum noise, optical loss, detectorinefficiency, electronic noise, pump noise, phase noise, mode mismatch, gain saturation, andpump depletion.Two operating modes are considered:1. phase-insensitive amplification, in which both quadratures are amplified and unavoidablequantum noise is introduced;2. phase-sensitive amplification, in which one selected quadrature can be amplified withlower added noise under appropriate phase matching.The primary endpoint is a prespecified detector-level signal-to-noise metric comparing theparametric amplifier with a gain-matched reference architecture.Secondary endpoints include the measured noise figure, effective gain, detection threshold,and downstream classification performance.The v3.1 framework introduces preregistered performance thresholds, a locked test set,independent calibration, blocked randomization, blinded analysis where feasible, hierarchical. statistical models, uncertainty propagation, multiplicity control, negative-control experiments,saturation diagnostics, and explicit falsification criteria.The proposal does not claim a universal amplification advantage, quantum supremacy, orclinical diagnostic capability.
This short and opinionated review starts with the concept of quantum signals at microwave frequencies and focuses on the principle of linear parametric amplification. This process emerges from the dispersive nonlinearity of Josephson junctions driven with appropriate tones. We discuss two defining characteristics of the corresponding amplifying devices: i) the number of modes excited by the signal, idler and pump waves and ii) the number of independent ports through which these waves enter into the circuit.
In this Master thesis, I present a theoretical description and experimental measurements of a tunable microwave resonator operated as a parametric amplifier. Superconducting parametric amplifiers have attracted great interest in recent years as it has been demonstrated that they can operate with a noise performance at the standard quantum limit. \nParametric amplification is achieved in the devices by modulating the electrical length of the resonator at twice the resonance frequency. The device measured in this thesis consists of a quarter-wavelength microwave resonator fabricated in a thin-film aluminum coplanar waveguide geometry. With a termination to ground through a Superconducting Quantum Interference Device (SQUID), the boundary condition of the resonator becomes sensitive to an applied magnetic field. This enables the tuning of the resonance frequencies, using a DC magnetic field, over a wide frequency range of 670MHz. Similarly, an AC magnetic field then allows for the modulation of the resonator electrical length at microwave frequencies. \nWe characterized the device by first measuring the DC tuning curves of the 2nd and 3rd harmonics of the resonator, around 4 GHz and 6 GHz respectively. We then studied parametric amplification in the device when the electrical length was modulated at approximately twice the resonance frequency of one of the modes. We scanned the pump frequency and pump power over a wide range to study the region in parameters which gives parametric gain. We performed an in-depth parameter sweep over this region, identifying pump parameters that provided maximum gain and maximum system noise improvements compared the following HEMT amplifier. \nWe find that the use of the parametric amplifier can improve the system noise temperature by more than 10 dB compared to a start-of-the-art commercial HEMT amplifier. This implies a performance near the standard quantum limit.