Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Physical Review A

Degenerate parametric amplification with time-dependent pump amplitude and phase

Maurice T. Raiford

Published May 1, 1974• 45 citations
Publisher

Abstract

A quantum-statistical treatment of degenerate (single-mode) parametric amplification is given in which the pump is allowed to have time-dependent amplitude and phase. This relaxes earlier restrictions of a constant pump in exact resonance with the signal. Solutions are obtained for the case where the ratio of the time derivative of the pump phase to the coupling strength between pump and signal is constant. This includes the special case of simple offresonance, where the pump has a constant frequency differing from twice the signal frequency by a given amount (and has constant amplitude). The Wigner distribution for the signal mode is obtained (the $P$ distribution does not in general exist as a well-defined function beyond a finite time interval for this process) and is used to determine the time development of the expectation values of various field operators of interest, such as field strengths and fluctuations. A critical point exists in the solution for the photon annihilation operator such that the behavior of the solution and the resulting quantities which it determines is divided into an exponential region and an oscillatory region. The critical point defines, from the expectation value for the photon number, the condition for amplification. For the case of simple off-resonance, this gives the frequency range of amplification. A calculation without using the rotating-wave approximation is given in the Appendix which shows that, to first order, the same range is obtained as when the approximation is used. The effect of damping is given, showing, e.g., how it slows the growth rate of the signal (in the region of amplification) and how it narrows the frequency range of amplification. The effect of a time-dependent pump (and damping) on the breakdown of the $P$ distribution is also described.

DOI
10.1103/physreva.9.2060

Related papers

Statistical Dynamics of Quantum Oscillators and Parametric Amplification in a Single Mode

Maurice T. Raiford

The description of the statistical dynamics of quantum oscillators is formulated in terms of the Wigner distribution, analogous to the more commonly used $P$ distribution, with explicit formulas being obtained for its time evolution and for average values. This formulation is desirable because, e.g., the Wigner distribution always exists whereas the $P$ distribution does not. The formalism is applied to the process of parametric amplification in a single mode, which may be considered as the degenerate form of the well-known two-mode case. This degeneracy gives rise to significantly different properties; for example, the $P$ distribution for the single mode of interest evolves from a circularly symmetric two-dimensional Gaussian into an elliptically symmetric form and ceases to exist after a finite time, even for amplification in the presence of losses. This is contrary to the two-mode case. The corresponding Wigner distribution is found to exist as a well-behaved function for all time as expected, regardless of the amount of losses, and is used to calculate average values of various quantities of interest. It is found, e.g., that in the lossless case the average number of photons in the signal mode always becomes infinite as $t\ensuremath{\rightarrow}\ensuremath{\infty}$. This is in contrast to the corresponding classical result for the lossless case which allows the signal to decay rather than to grow with time, depending on the relative phase between the signal and the pump. Field fluctuations are discussed and found to have some unusual properties. The combination of frequency up-conversion with single-mode amplification is also described briefly. The effect of the quantization of the pump oscillator is considered in an Appendix.

Physical Review A•Oct 1, 1970•61 citations

Effect of the pump state on the behavior of the degenerate parametric amplifier

Mark S. Hillery, Daoqi Yu, János A. Bergou

We study the effect of non-coherent-state pumps on the behavior of the degenerate parametric amplifier. This is done both by developing some exact results and by extending the parametric approximation. Relations are found between the number fluctuations in the pump and those in the signal. The effect of initial phase uncertainty in the pump on the squeezing in the signal is also determined. In addition, we find that rotational symmetry in phase space of the signal-mode state is twice that of the pump-mode state. This implies, for example, that a pump in the squeezed vacuum state will produce a signal-mode state with a four-pronged structure. The effect of a squeezed pump with nonzero amplitude is studied by using a more general form of the parametric approximation. It is shown that in the time interval during which the parametric approximation is valid the effect of this pump is the same as one which is an incoherent superposition of coherent states. We find that while the squeezing of the pump degrades the squeezing of the signal it enhances its amplitude-squared squeezing.

Physical Review A•Feb 1, 1994•22 citations

Optimally detuned parametric amplification, and associated devices

Aashish A. Clerk, McDonald, Alexander

Optimally detuned parametric amplification amplifies a signal in a resonator that is driven off-resonance, with respect to a signal mode, using a far-detuned pump. This pump establishes a parametric drive strength, and is "far-detuned" in that its detuning from the signal mode is greater than the drive strength. The amplitude and frequency of the pump are chosen so that the eigenfrequency of the resulting Bogoliobov mode matches a photonic loss rate of the Bogoliobov mode. In this case, a signal coupled into the Bogoliobov mode will be amplified with a gain that is broader and flatter than that achieved with conventional parametric amplification, and is not limited by a gain-bandwidth product. Optimally detuned parametric amplification may be used for degenerate or non-degenerate parametric amplification, and may be used to amplify microwaves, light, electronic signals, acoustic waves, or any other type of signal that can be amplified using conventional parametric amplification.

•Dec 13, 2020•0 citations

Quantum Dynamics of Non-Degenerate Parametric Amplification

Per Kristian Rekdal, Bo-Sture Skagerstam

A simple model of a two-mode non-resonant parametric amplifier is studied with special regard to non-classical features such as revivals and squeezing. The methods used apply for an arbitrary pump parameter. Detailed analytical and explicit expressions are given when the coupling of the two modes has a harmonic time-dependence. Despite its simplicity the model exhibits a very broad range of intricate physical effects. We show that quantum revivals are possible for a broad continuous range of physical parameters in the case of initial Fock states. For coherent states we find that such revivals are possible only for certain discrete rational number combinations of the ratio of frequency detuning and pump parameters. Correlation effects are shown to be very sensitive to the initial state of the system.

arXiv:quant-ph/9910007•Physica Scripta•Mar 1, 2000•13 citations

Optimally Detuned Parametric Amplification, and Associated Devices

Aashish A. Clerk, McDonald, Alexander

Optimally detuned parametric amplification amplifies a signal in a resonator that is driven off-resonance, with respect to a signal mode, using a far-detuned pump. This pump establishes a parametric drive strength, and is "far-detuned" in that its detuning from the signal mode is greater than the drive strength. The amplitude and frequency of the pump are chosen so that the eigenfrequency of the resulting Bogoliobov mode matches a photonic loss rate of the Bogoliobov mode. In this case, a signal coupled into the Bogoliobov mode will be amplified with a gain that is broader and flatter than that achieved with conventional parametric amplification, and is not limited by a gain-bandwidth product. Optimally detuned parametric amplification may be used for degenerate or non-degenerate parametric amplification, and may be used to amplify microwaves, light, electronic signals, acoustic waves, or any other type of signal that can be amplified using conventional parametric amplification.

•Dec 13, 2020•0 citations

Comment on "Conversion of random-phase light into phase-coherent light"

Maurice T. Raiford

Previous results concerning the evolution of the signal towards light of well-defined phase during the degenerate parametric amplification process are pointed out, as well as how this is affected by damping, the time dependence of the pump, and the additional process of frequency up-conversion.

Physical Review A•May 1, 1975•0 citations
A quantum-statistical treatment of degenerate (single-mode) parametric amplification is given in which the pump is allowed to have time-dependent amplitude and phase. This relaxes earlier restrictions of a constant pump in exact resonance with the signal. Solutions are obtained for the case where the ratio of the time derivative of the pump phase to the coupling strength between pump and signal is constant. This includes the special case of simple offresonance, where the pump has a constant frequency differing from twice the signal frequency by a given amount (and has constant amplitude). The Wigner distribution for the signal mode is obtained (the PPP distribution does not in general exist as a well-defined function beyond a finite time interval for this process) and is used to determine the time development of the expectation values of various field operators of interest, such as field strengths and fluctuations. A critical point exists in the solution for the photon annihilation operator such that the behavior of the solution and the resulting quantities which it determines is divided into an exponential region and an oscillatory region. The critical point defines, from the expectation value for the photon number, the condition for amplification. For the case of simple off-resonance, this gives the frequency range of amplification. A calculation without using the rotating-wave approximation is given in the Appendix which shows that, to first order, the same range is obtained as when the approximation is used. The effect of damping is given, showing, e.g., how it slows the growth rate of the signal (in the region of amplification) and how it narrows the frequency range of amplification. The effect of a time-dependent pump (and damping) on the breakdown of the PPP distribution is also described.
The description of the statistical dynamics of quantum oscillators is formulated in terms of the Wigner distribution, analogous to the more commonly used PPP distribution, with explicit formulas being obtained for its time evolution and for average values. This formulation is desirable because, e.g., the Wigner distribution always exists whereas the PPP distribution does not. The formalism is applied to the process of parametric amplification in a single mode, which may be considered as the degenerate form of the well-known two-mode case. This degeneracy gives rise to significantly different properties; for example, the PPP distribution for the single mode of interest evolves from a circularly symmetric two-dimensional Gaussian into an elliptically symmetric form and ceases to exist after a finite time, even for amplification in the presence of losses. This is contrary to the two-mode case. The corresponding Wigner distribution is found to exist as a well-behaved function for all time as expected, regardless of the amount of losses, and is used to calculate average values of various quantities of interest. It is found, e.g., that in the lossless case the average number of photons in the signal mode always becomes infinite as $t\ensuremath{\rightarrow}\ensuremath{\infty}$. This is in contrast to the corresponding classical result for the lossless case which allows the signal to decay rather than to grow with time, depending on the relative phase between the signal and the pump. Field fluctuations are discussed and found to have some unusual properties. The combination of frequency up-conversion with single-mode amplification is also described briefly. The effect of the quantization of the pump oscillator is considered in an Appendix.
We study the effect of non-coherent-state pumps on the behavior of the degenerate parametric amplifier. This is done both by developing some exact results and by extending the parametric approximation. Relations are found between the number fluctuations in the pump and those in the signal. The effect of initial phase uncertainty in the pump on the squeezing in the signal is also determined. In addition, we find that rotational symmetry in phase space of the signal-mode state is twice that of the pump-mode state. This implies, for example, that a pump in the squeezed vacuum state will produce a signal-mode state with a four-pronged structure. The effect of a squeezed pump with nonzero amplitude is studied by using a more general form of the parametric approximation. It is shown that in the time interval during which the parametric approximation is valid the effect of this pump is the same as one which is an incoherent superposition of coherent states. We find that while the squeezing of the pump degrades the squeezing of the signal it enhances its amplitude-squared squeezing.
Optimally detuned parametric amplification amplifies a signal in a resonator that is driven off-resonance, with respect to a signal mode, using a far-detuned pump. This pump establishes a parametric drive strength, and is "far-detuned" in that its detuning from the signal mode is greater than the drive strength. The amplitude and frequency of the pump are chosen so that the eigenfrequency of the resulting Bogoliobov mode matches a photonic loss rate of the Bogoliobov mode. In this case, a signal coupled into the Bogoliobov mode will be amplified with a gain that is broader and flatter than that achieved with conventional parametric amplification, and is not limited by a gain-bandwidth product. Optimally detuned parametric amplification may be used for degenerate or non-degenerate parametric amplification, and may be used to amplify microwaves, light, electronic signals, acoustic waves, or any other type of signal that can be amplified using conventional parametric amplification.
A simple model of a two-mode non-resonant parametric amplifier is studied with special regard to non-classical features such as revivals and squeezing. The methods used apply for an arbitrary pump parameter. Detailed analytical and explicit expressions are given when the coupling of the two modes has a harmonic time-dependence. Despite its simplicity the model exhibits a very broad range of intricate physical effects. We show that quantum revivals are possible for a broad continuous range of physical parameters in the case of initial Fock states. For coherent states we find that such revivals are possible only for certain discrete rational number combinations of the ratio of frequency detuning and pump parameters. Correlation effects are shown to be very sensitive to the initial state of the system.
Optimally detuned parametric amplification amplifies a signal in a resonator that is driven off-resonance, with respect to a signal mode, using a far-detuned pump. This pump establishes a parametric drive strength, and is "far-detuned" in that its detuning from the signal mode is greater than the drive strength. The amplitude and frequency of the pump are chosen so that the eigenfrequency of the resulting Bogoliobov mode matches a photonic loss rate of the Bogoliobov mode. In this case, a signal coupled into the Bogoliobov mode will be amplified with a gain that is broader and flatter than that achieved with conventional parametric amplification, and is not limited by a gain-bandwidth product. Optimally detuned parametric amplification may be used for degenerate or non-degenerate parametric amplification, and may be used to amplify microwaves, light, electronic signals, acoustic waves, or any other type of signal that can be amplified using conventional parametric amplification.