WITHDRAWN (v1.2, November 2026; notice revised from v1.1). The main claim of this preprint — that πνZZτ* ≈ 0.873 rad is an observed cross-platform invariant and the optimal feedforward condition — is withdrawn. Origin of 0.873. The value comes from the best of three delays (30/50/70 µs) in a single 2026-03-15 run on ibm_marrakesh Q94–Q95, in which the feedforward circuit applied the delay only to the ancilla and the reference circuits only to the target; the apparent optimum followed the target's own Ramsey fringe and is not a feedforward result. The value was then fixed as an input. No independent test. In all later IBM runs the delay was set to τ = 0.873/(πνZZ), so the constancy holds by construction. A measurement of the optimum without 0.873 as an input was planned but not performed. νZZ values came from a detuned single-quadrature Ramsey fit later found to overestimate νZZ by ≈3× and to lose its sign. Measured quantity. The IBM values in Table 1 come from a circuit with a conditional X (not Rz), so φff does not enter; the reported GPS is Fff − Fstatic, not Pff − Pref as defined. The IQM scan and the circuit of Appendix B apply Rz before a Z-basis measurement, for which the ideal response is zero (cf. 10.5281/zenodo.20961679, Sec. 4.1). IQM. The 18 values in the archived scan files give GPS(τ = 7 µs) = −0.006 ± 0.007; the tabulated +0.026 ± 0.011 (n = 5) could not be reproduced, and no n = 29 data set was found. Operational note. Setting τ = 0.873/(πνZZ) on IBM Heron r2 gave GPS > 0 on most pairs tried; 0.873 rad is retained only as an empirical operating setting, not as an optimum or a constant. The derivation φ*ff = arg⟨eiφ⟩ is unaffected. The PDF contains this notice followed by the original text unchanged.
WITHDRAWN (v1.2, November 2026; notice revised from v1.1). The main claim of this preprint — that πνZZτ* ≈ 0.873 rad is an observed cross-platform invariant and the optimal feedforward condition — is withdrawn. Origin of 0.873. The value comes from the best of three delays (30/50/70 µs) in a single 2026-03-15 run on ibm_marrakesh Q94–Q95, in which the feedforward circuit applied the delay only to the ancilla and the reference circuits only to the target; the apparent optimum followed the target's own Ramsey fringe and is not a feedforward result. The value was then fixed as an input. No independent test. In all later IBM runs the delay was set to τ = 0.873/(πνZZ), so the constancy holds by construction. A measurement of the optimum without 0.873 as an input was planned but not performed. νZZ values came from a detuned single-quadrature Ramsey fit later found to overestimate νZZ by ≈3× and to lose its sign. Measured quantity. The IBM values in Table 1 come from a circuit with a conditional X (not Rz), so φff does not enter; the reported GPS is Fff − Fstatic, not Pff − Pref as defined. The IQM scan and the circuit of Appendix B apply Rz before a Z-basis measurement, for which the ideal response is zero (cf. 10.5281/zenodo.20961679, Sec. 4.1). IQM. The 18 values in the archived scan files give GPS(τ = 7 µs) = −0.006 ± 0.007; the tabulated +0.026 ± 0.011 (n = 5) could not be reproduced, and no n = 29 data set was found. Operational note. Setting τ = 0.873/(πνZZ) on IBM Heron r2 gave GPS > 0 on most pairs tried; 0.873 rad is retained only as an empirical operating setting, not as an optimum or a constant. The derivation φ*ff = arg⟨eiφ⟩ is unaffected. The PDF contains this notice followed by the original text unchanged.
Version 6.2 (November 2026) — corrections to V6.1. Main result restated. GPS = +0.037 ± 0.011 (z = 3.35) at τ = 30 µs, N = 1; 8 of 10 conditions significant after Holm correction; Stouffer z = 7.3 over all 10 (independence assumed). This is kept as a statistically significant difference between the MCM-conditioned feedforward circuit and the reference circuit. Its attribution to ZZ-phase correction is not established: the correction parameter νZZ = 3.6 kHz came from a detuned single-quadrature Ramsey fit (2026-03-01), a method later found to overestimate νZZ by ≈3×; the same pair measured with the same method on 2026-03-06 gave 0.06 kHz; and no MCM-only control was run. 2026-03-15 follow-up withdrawn as evidence. In all follow-up scripts the delay was applied only to the ancilla in the feedforward circuit and only to the target in the reference circuits. The reference fidelity therefore traces the target's own Ramsey fringe (0.97 → 0.12 over 5–70 µs) while the feedforward circuit stays at 0.8–0.99, and the reported +0.726 (z = 66) exceeds the ≈0.21 maximum that a conditional Rz(0.873) can produce. The apparent optimum at 50 µs, the ref0 comparison and the T2 discussion are affected in the same way. In a same-job IQM control (2026-03-17), the gain from the same asymmetry (+0.19 to +0.24) vanished when the delay was applied to the target in both circuits (+0.105, +0.030, −0.016). Model statements (τ* formula, predicted gain curve, stochastic-timing regime) are marked as model predictions not confirmed by the data; leftover "8.5σ" and "<5% agreement" in the conclusion corrected. Files: EEDT_paper_v6_2.pdf / .tex and README_v6_2.md replace the V6.1 paper files and README; other scripts and figures unchanged.
Withdrawn (version 2, 2026-11-06). The central claim of version 1 does not hold. A control run with a fixed qubit layout shows no state dependence of the damping, and the 465-gate failures do not test the transfer assumption. A two-page withdrawal notice precedes the unchanged original text in the PDF; the conclusions of version 1 should not be used. Control run FS40. The same three 161-gate circuits as in version 1 (identical angles) were transpiled once with a common initial layout and a fixed transpiler seed; the two-qubit gate sequence is identical for all angles, and layout and gate hash are stored with the data. On ibm_marrakesh (one job, five circuits, two repeats, 32,768 shots each) the raw ⟨K²⟩ values are 157.15, 158.63 and 158.41 (±0.65); the largest violation of the affine transfer bound is 0.5σ, against up to 13σ in July. The July effect does not recur. Most likely cause: in July the circuits were transpiled separately without a fixed layout or seed, and the layouts were not recorded. 465-gate failures. In all seven cross-validations calibration and target circuits differ in depth (140–300 two-qubit gates), so the failures show only that a per-gate extrapolation between differently routed circuits fails. The only structurally identical repeat at 465 gates agrees (107.50 ± 2.10 vs. 107.12 ± 2.17). What remains is standard practice, not a new result: fix and record layout and seed in any transfer test, and use calibration and target circuits of equal depth and routing. FS40 code and data: fs40_control_run_data_2026-11-06.zip (this record). Original data set: doi:10.5281/zenodo.22953020. Original abstract of version 1 (withdrawn): On a superconducting processor, the damping that reference-based error mitigation must carry from a reference circuit to a signal circuit is not a property of the circuit: at identical depth, routing and gate content, changing only a rotation angle moves it by twenty to thirty standard deviations (χ²/dof = 116), while three repetitions of one and the same circuit agree within shot noise (1.5). The transfer assumption behind most mitigation schemes is seldom testable, because the exact answer on the signal circuit is usually unknown. Here it is known on every circuit. The observable is collective, ⟨K²⟩ of a 24-qubit nuclear shell-model state on ibm_marrakesh, read inside a postselected symmetry sector. At 161 two-qubit gates it is reconstructed to about one unit. At 465 gates two independent corrections fail: a mixture estimator with an in-situ calibrated false-positive kernel loses identifiability, and an operator-level renormalization without any shape model misses the known values by −69 to +283 units. From this diagnosis follows a pre-flight test, costing about ten seconds of processor time, that decides before a production run whether reference-based mitigation can work for a given observable and depth.
Version 10 (November 2026) — corrections to v9. The v8 hardware result (ibm_marrakesh Q6–Q7) remains unconfirmed, but the reason is restated. v9 said that later runs of the same protocol family did not reproduce it; those runs (GPS v3–v6) used a different protocol without post-selection. v10 instead states: the correction angles in the v8 run were at most 0.02 rad (νZZ = 0.13 kHz, 30 µs wait), which can change the fidelity by at most ≈0.01. The reported gains (up to +0.112, σ ≈ 0.02–0.04 from ≈80–400 post-selected shots per setting) therefore cannot be attributed to the correction and are consistent with statistical fluctuation. No direct replication with the same post-selected protocol was performed. Section 4.4, Fig. 2, Table 3, the device-compatibility paragraph and the conclusion are updated accordingly. Earlier changes (v9, retained): the Nmeas = 8 gain (+0.112, z = 2.7) does not pass Bonferroni correction over the 8 tested settings; the a-priori region contains five settings, and Holm over these leaves Nmeas = 2 and 8; the convergence proposition bounds the post-selected fidelity but does not predict the gain; MCM dead-time explains only part of the theory–experiment gap.
Two acquisitions on physical qubit 0 of IBM Fez examine Ramsey, centered Hahn-echo and pre-idle phaseresponse, followed by asymmetric echo placement. WAVE002 (November 6, 2026) contains 416 circuits and53,248 shots. WAVE003 (November 14, 2026) contains 240 circuits and 61,440 shots. Centered echo exceededRamsey at the WAVE002 8-microsecond anchor and exceeded both quarter- and three-quarter-position echoesat both tested WAVE003 holds. The main contrasts survive a publication-level simultaneous uncertaintyallocation across both studies, conditional on independent bounded shots The supplement supplies recorded shots and counts, frozen analyzers, circuit inventories and readable instructions, archived results, offline replay and labeled exploratory model comparisons. The original WAVE002 sparse-count failure and its lossless correction are preserved. The acquisitions are complementary, not identical independent replications. Physical shot independence, pulse timing and chronological execution were not independently attested. An uncertainty-aware absolute-response comparison finds conventional quasi-static and slow finite-correlation models compatible with all pooled gain coordinates. An unsuccessful retrospective point forecast is preserved alongside its broad training-only uncertainty. No unexplained anomaly, technological improvement, unique noise mechanism, calibrated memory fidelity or new echo method is established. AI assistance is disclosed. This is a preprint, not a claim of peer review or journal acceptance.
AbstractWe present Quantum-6502, a self-calibrating BIOS layer for Entanglement-Enhanced Dynamical Tracking (EEDT) based phase-storage on IBM Heron r2 superconducting processors. EEDT is a proof-of-concept phase-storage protocol that demonstrates how always-on ZZ coupling can be converted into a feedforward resource via mid-circuit measurement (MCM), rather than suppressed. Key Features of Quantum-6502 BIOS:Universal Pair Discovery (Layer 0): Automatically discovers suitable qubit pairs from backend calibration data using zero quantum jobs.Ultra-Light Calibration (ULC): Measures νZZ and T2 using only 2 jobs (9 circuits).Adaptive Execution: Executes QFEED+ adaptive feedforward to compensate for per-session drift without user intervention. Hardware Validation Results:Static vs. Dynamic Contrast: On ibm_kingston (Q149+Q150), the system yielded GPS_dynamic = +0.345 ± 0.007 versus GPS_static = −0.201 (Δ = +0.546, z = 47.96σ), assuming shot-level independence with binomial standard error. This contrast provides strong direct evidence consistent with the stochastic collapse-timing mechanism of EEDT.Cross-Backend Consistency: Validation on ibm_marrakesh confirms GPS = +0.037 (z = 8.5σ combined, 8 Holm-corrected conditions) and GPS = +0.726 (z = 66σ).Expanded Operating Regime: The kingston result extends the confirmed operating regime to ωZZT2 = 21.9. Based on the data, τ*/TMCM ≥ 5 is tentatively proposed as the operative constraint, ensuring that measurement overhead remains subdominant to coherent evolution.Robustness: Sensitivity analysis confirms that EEDT gain remains positive (GPS > 0) across a ±30% variance (covering observed drift ranges) from the MANUAL calibration estimate of νZZ. Consistency with AUTO-mode estimates (where available) indicates no systematic bias introduced by the MANUAL override. AvailabilityThe present validation is restricted to IBM Heron r2. All system code, raw experimental data, and IBM Quantum job IDs are publicly available in the linked repository.
A feedforward protocol that converts decoherence into an information resource for quantum control. The Bell Decay Clock encodes timing information in measurement-resolved decay pathways of entangled states, enabling mid-circuit measurement (MCM) to extract useful classical information even after phase coherence is lost. Key results:- IBM Heron: Bell clock maintains GPS > 0 over 3-4x wider window than ZZ clock (18/18 points, z > 5σ)- IQM Garnet: ZZ clock fails completely (GPS < 0, all points), Bell clock succeeds (GPS = +0.19, 4.4σ)- Static vs Dynamic control: ΔGPS = +0.55 isolates MCM feedback as active mechanism- Universal feedforward phase ϕ* = 0.873 rad verified across 3 independent qubit pairs Related: EEDT protocol (DOI: 10.5281/zenodo.19029431)Code: https://github.com/okudat9/Quantum-6502