Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

EEDT: Entanglement-Enhanced Dynamical Tracking for ZZ-Coupled Superconducting Qubits

Takeshi Okuda

Published Mar 3, 2026• 1 citation
Publisher

Abstract

Version 6.2 (November 2026) — corrections to V6.1. Main result restated. GPS = +0.037 ± 0.011 (z = 3.35) at τ = 30 µs, N = 1; 8 of 10 conditions significant after Holm correction; Stouffer z = 7.3 over all 10 (independence assumed). This is kept as a statistically significant difference between the MCM-conditioned feedforward circuit and the reference circuit. Its attribution to ZZ-phase correction is not established: the correction parameter νZZ = 3.6 kHz came from a detuned single-quadrature Ramsey fit (2026-03-01), a method later found to overestimate νZZ by ≈3×; the same pair measured with the same method on 2026-03-06 gave 0.06 kHz; and no MCM-only control was run. 2026-03-15 follow-up withdrawn as evidence. In all follow-up scripts the delay was applied only to the ancilla in the feedforward circuit and only to the target in the reference circuits. The reference fidelity therefore traces the target's own Ramsey fringe (0.97 → 0.12 over 5–70 µs) while the feedforward circuit stays at 0.8–0.99, and the reported +0.726 (z = 66) exceeds the ≈0.21 maximum that a conditional Rz(0.873) can produce. The apparent optimum at 50 µs, the ref0 comparison and the T2 discussion are affected in the same way. In a same-job IQM control (2026-03-17), the gain from the same asymmetry (+0.19 to +0.24) vanished when the delay was applied to the target in both circuits (+0.105, +0.030, −0.016). Model statements (τ* formula, predicted gain curve, stochastic-timing regime) are marked as model predictions not confirmed by the data; leftover "8.5σ" and "<5% agreement" in the conclusion corrected. Files: EEDT_paper_v6_2.pdf / .tex and README_v6_2.md replace the V6.1 paper files and README; other scripts and figures unchanged.

DOI
10.5281/zenodo.18848144

Related papers

[WITHDRAWN] Phase-Invariant Condition for Optimal Feedforward in ZZ-Coupled Quantum Systems: Experimental Validation on IBM Heron r2 and IQM Garnet

Takeshi Okuda

WITHDRAWN (v1.2, November 2026; notice revised from v1.1). The main claim of this preprint — that πνZZτ* ≈ 0.873 rad is an observed cross-platform invariant and the optimal feedforward condition — is withdrawn. Origin of 0.873. The value comes from the best of three delays (30/50/70 µs) in a single 2026-03-15 run on ibm_marrakesh Q94–Q95, in which the feedforward circuit applied the delay only to the ancilla and the reference circuits only to the target; the apparent optimum followed the target's own Ramsey fringe and is not a feedforward result. The value was then fixed as an input. No independent test. In all later IBM runs the delay was set to τ = 0.873/(πνZZ), so the constancy holds by construction. A measurement of the optimum without 0.873 as an input was planned but not performed. νZZ values came from a detuned single-quadrature Ramsey fit later found to overestimate νZZ by ≈3× and to lose its sign. Measured quantity. The IBM values in Table 1 come from a circuit with a conditional X (not Rz), so φff does not enter; the reported GPS is Fff − Fstatic, not Pff − Pref as defined. The IQM scan and the circuit of Appendix B apply Rz before a Z-basis measurement, for which the ideal response is zero (cf. 10.5281/zenodo.20961679, Sec. 4.1). IQM. The 18 values in the archived scan files give GPS(τ = 7 µs) = −0.006 ± 0.007; the tabulated +0.026 ± 0.011 (n = 5) could not be reproduced, and no n = 29 data set was found. Operational note. Setting τ = 0.873/(πνZZ) on IBM Heron r2 gave GPS > 0 on most pairs tried; 0.873 rad is retained only as an empirical operating setting, not as an optimum or a constant. The derivation φ*ff = arg⟨eiφ⟩ is unaffected. The PDF contains this notice followed by the original text unchanged.

•Apr 15, 2026•0 citations

Entanglement in superconducting quantum devices and improving quantum circuit compilation

Gary J. Mooney

•Jan 1, 2021•0 citations

Quantum-6502: A Self-Calibrating Quantum BIOS with Universal Pair Discovery and Cross-Backend Validation on IBM Heron r2

Takeshi Okuda

AbstractWe present Quantum-6502, a self-calibrating BIOS layer for Entanglement-Enhanced Dynamical Tracking (EEDT) based phase-storage on IBM Heron r2 superconducting processors. EEDT is a proof-of-concept phase-storage protocol that demonstrates how always-on ZZ coupling can be converted into a feedforward resource via mid-circuit measurement (MCM), rather than suppressed. Key Features of Quantum-6502 BIOS:Universal Pair Discovery (Layer 0): Automatically discovers suitable qubit pairs from backend calibration data using zero quantum jobs.Ultra-Light Calibration (ULC): Measures νZZ and T2 using only 2 jobs (9 circuits).Adaptive Execution: Executes QFEED+ adaptive feedforward to compensate for per-session drift without user intervention. Hardware Validation Results:Static vs. Dynamic Contrast: On ibm_kingston (Q149+Q150), the system yielded GPS_dynamic = +0.345 ± 0.007 versus GPS_static = −0.201 (Δ = +0.546, z = 47.96σ), assuming shot-level independence with binomial standard error. This contrast provides strong direct evidence consistent with the stochastic collapse-timing mechanism of EEDT.Cross-Backend Consistency: Validation on ibm_marrakesh confirms GPS = +0.037 (z = 8.5σ combined, 8 Holm-corrected conditions) and GPS = +0.726 (z = 66σ).Expanded Operating Regime: The kingston result extends the confirmed operating regime to ωZZT2 = 21.9. Based on the data, τ*/TMCM ≥ 5 is tentatively proposed as the operative constraint, ensuring that measurement overhead remains subdominant to coherent evolution.Robustness: Sensitivity analysis confirms that EEDT gain remains positive (GPS > 0) across a ±30% variance (covering observed drift ranges) from the MANUAL calibration estimate of νZZ. Consistency with AUTO-mode estimates (where available) indicates no systematic bias introduced by the MANUAL override. AvailabilityThe present validation is restricted to IBM Heron r2. All system code, raw experimental data, and IBM Quantum job IDs are publicly available in the linked repository.

•Mar 22, 2026•0 citations

Modulation of Entanglement for Coupled Superconducting Qubits Under Non-Markovian Environment

Yan‐Li Ji, Juju Hu, Zhen Wang

International Journal of Theoretical Physics•May 18, 2010•2 citations

EEDT: Measurement-Gated Quantum Error Correction for NISQ Calibration Drift

Takeshi Okuda

Version 10 (November 2026) — corrections to v9. The v8 hardware result (ibm_marrakesh Q6–Q7) remains unconfirmed, but the reason is restated. v9 said that later runs of the same protocol family did not reproduce it; those runs (GPS v3–v6) used a different protocol without post-selection. v10 instead states: the correction angles in the v8 run were at most 0.02 rad (νZZ = 0.13 kHz, 30 µs wait), which can change the fidelity by at most ≈0.01. The reported gains (up to +0.112, σ ≈ 0.02–0.04 from ≈80–400 post-selected shots per setting) therefore cannot be attributed to the correction and are consistent with statistical fluctuation. No direct replication with the same post-selected protocol was performed. Section 4.4, Fig. 2, Table 3, the device-compatibility paragraph and the conclusion are updated accordingly. Earlier changes (v9, retained): the Nmeas = 8 gain (+0.112, z = 2.7) does not pass Bonferroni correction over the 8 tested settings; the a-priori region contains five settings, and Holm over these leaves Nmeas = 2 and 8; the convergence proposition bounds the post-selected fidelity but does not predict the gain; MCM dead-time explains only part of the theory–experiment gap.

•Feb 28, 2026•0 citations

Dynamics of entanglement and Bell-nonlocality for the interacting of coupled superconductor qubits and common environment

Yinghua Ji

Optik•Aug 4, 2012•2 citations
Version 6.2 (November 2026) — corrections to V6.1. Main result restated. GPS = +0.037 ± 0.011 (z = 3.35) at τ = 30 µs, N = 1; 8 of 10 conditions significant after Holm correction; Stouffer z = 7.3 over all 10 (independence assumed). This is kept as a statistically significant difference between the MCM-conditioned feedforward circuit and the reference circuit. Its attribution to ZZ-phase correction is not established: the correction parameter νZZ = 3.6 kHz came from a detuned single-quadrature Ramsey fit (2026-03-01), a method later found to overestimate νZZ by ≈3×; the same pair measured with the same method on 2026-03-06 gave 0.06 kHz; and no MCM-only control was run. 2026-03-15 follow-up withdrawn as evidence. In all follow-up scripts the delay was applied only to the ancilla in the feedforward circuit and only to the target in the reference circuits. The reference fidelity therefore traces the target's own Ramsey fringe (0.97 → 0.12 over 5–70 µs) while the feedforward circuit stays at 0.8–0.99, and the reported +0.726 (z = 66) exceeds the ≈0.21 maximum that a conditional Rz(0.873) can produce. The apparent optimum at 50 µs, the ref0 comparison and the T2 discussion are affected in the same way. In a same-job IQM control (2026-03-17), the gain from the same asymmetry (+0.19 to +0.24) vanished when the delay was applied to the target in both circuits (+0.105, +0.030, −0.016). Model statements (τ* formula, predicted gain curve, stochastic-timing regime) are marked as model predictions not confirmed by the data; leftover "8.5σ" and "<5% agreement" in the conclusion corrected. Files: EEDT_paper_v6_2.pdf / .tex and README_v6_2.md replace the V6.1 paper files and README; other scripts and figures unchanged.
WITHDRAWN (v1.2, November 2026; notice revised from v1.1). The main claim of this preprint — that πνZZτ* ≈ 0.873 rad is an observed cross-platform invariant and the optimal feedforward condition — is withdrawn. Origin of 0.873. The value comes from the best of three delays (30/50/70 µs) in a single 2026-03-15 run on ibm_marrakesh Q94–Q95, in which the feedforward circuit applied the delay only to the ancilla and the reference circuits only to the target; the apparent optimum followed the target's own Ramsey fringe and is not a feedforward result. The value was then fixed as an input. No independent test. In all later IBM runs the delay was set to τ = 0.873/(πνZZ), so the constancy holds by construction. A measurement of the optimum without 0.873 as an input was planned but not performed. νZZ values came from a detuned single-quadrature Ramsey fit later found to overestimate νZZ by ≈3× and to lose its sign. Measured quantity. The IBM values in Table 1 come from a circuit with a conditional X (not Rz), so φff does not enter; the reported GPS is Fff − Fstatic, not Pff − Pref as defined. The IQM scan and the circuit of Appendix B apply Rz before a Z-basis measurement, for which the ideal response is zero (cf. 10.5281/zenodo.20961679, Sec. 4.1). IQM. The 18 values in the archived scan files give GPS(τ = 7 µs) = −0.006 ± 0.007; the tabulated +0.026 ± 0.011 (n = 5) could not be reproduced, and no n = 29 data set was found. Operational note. Setting τ = 0.873/(πνZZ) on IBM Heron r2 gave GPS > 0 on most pairs tried; 0.873 rad is retained only as an empirical operating setting, not as an optimum or a constant. The derivation φ*ff = arg⟨eiφ⟩ is unaffected. The PDF contains this notice followed by the original text unchanged.
AbstractWe present Quantum-6502, a self-calibrating BIOS layer for Entanglement-Enhanced Dynamical Tracking (EEDT) based phase-storage on IBM Heron r2 superconducting processors. EEDT is a proof-of-concept phase-storage protocol that demonstrates how always-on ZZ coupling can be converted into a feedforward resource via mid-circuit measurement (MCM), rather than suppressed. Key Features of Quantum-6502 BIOS:Universal Pair Discovery (Layer 0): Automatically discovers suitable qubit pairs from backend calibration data using zero quantum jobs.Ultra-Light Calibration (ULC): Measures νZZ and T2 using only 2 jobs (9 circuits).Adaptive Execution: Executes QFEED+ adaptive feedforward to compensate for per-session drift without user intervention. Hardware Validation Results:Static vs. Dynamic Contrast: On ibm_kingston (Q149+Q150), the system yielded GPS_dynamic = +0.345 ± 0.007 versus GPS_static = −0.201 (Δ = +0.546, z = 47.96σ), assuming shot-level independence with binomial standard error. This contrast provides strong direct evidence consistent with the stochastic collapse-timing mechanism of EEDT.Cross-Backend Consistency: Validation on ibm_marrakesh confirms GPS = +0.037 (z = 8.5σ combined, 8 Holm-corrected conditions) and GPS = +0.726 (z = 66σ).Expanded Operating Regime: The kingston result extends the confirmed operating regime to ωZZT2 = 21.9. Based on the data, τ*/TMCM ≥ 5 is tentatively proposed as the operative constraint, ensuring that measurement overhead remains subdominant to coherent evolution.Robustness: Sensitivity analysis confirms that EEDT gain remains positive (GPS > 0) across a ±30% variance (covering observed drift ranges) from the MANUAL calibration estimate of νZZ. Consistency with AUTO-mode estimates (where available) indicates no systematic bias introduced by the MANUAL override. AvailabilityThe present validation is restricted to IBM Heron r2. All system code, raw experimental data, and IBM Quantum job IDs are publicly available in the linked repository.
Version 10 (November 2026) — corrections to v9. The v8 hardware result (ibm_marrakesh Q6–Q7) remains unconfirmed, but the reason is restated. v9 said that later runs of the same protocol family did not reproduce it; those runs (GPS v3–v6) used a different protocol without post-selection. v10 instead states: the correction angles in the v8 run were at most 0.02 rad (νZZ = 0.13 kHz, 30 µs wait), which can change the fidelity by at most ≈0.01. The reported gains (up to +0.112, σ ≈ 0.02–0.04 from ≈80–400 post-selected shots per setting) therefore cannot be attributed to the correction and are consistent with statistical fluctuation. No direct replication with the same post-selected protocol was performed. Section 4.4, Fig. 2, Table 3, the device-compatibility paragraph and the conclusion are updated accordingly. Earlier changes (v9, retained): the Nmeas = 8 gain (+0.112, z = 2.7) does not pass Bonferroni correction over the 8 tested settings; the a-priori region contains five settings, and Holm over these leaves Nmeas = 2 and 8; the convergence proposition bounds the post-selected fidelity but does not predict the gain; MCM dead-time explains only part of the theory–experiment gap.