Analysis of the light shift in a Rb atomic clock pumped by detuned laser

勲 松田, 静夫 山口, Isao Matsuda, Shizuo Yamaguchi

Published Jan 1, 1992• 0 citations
OpenAlex

Abstract

ln recent years, laser pumped Rb atomic clocks have been numerously studied and developed to reduce "light shift" and increase the accuracy and stability of the frequency. Previously, we reoorted on the measurement of the linewidths and S/N of the optical-microwave double resonance signal and the light shift in a Rb atomic clock pumped by a stabilized diode laser. In this paper, the light shift was numerically calculated by using the theory proposed by Cohen-Tannoudji & Barrat. Furthermore, contributions of the laser power and frequency detuning to the light shift were also estimated to attain the microwave frequency stability as high as 10^<-12>.

Related papers

Analysis of the light shift effect in the /sup 87/Rb frequency standard

F. Levi, Carlo Novero, A. Godone

The /sup 87/Rb cell frequency standard, optically pumped by a laser diode, is of great interest in the development of high short-term stability oscillators. We report experiments performed on a rubidium cell prototype aiming at evaluate the transfer of the laser noise to the hyperfine clock transition via the light shift effect, which appears to be the main contribution to the observed short term frequency stability in this kind of standard. Pulsed optical pumping will also be examined in order to strongly reduce the light shift effect and to achieve the theoretical limit never approached up to now despite the strong detected microwave signals.

Conference on Precision Electromagnetic Measurements•Dec 24, 2002•0 citations

A novel method to compensate for the effect of light shift in a rubidium atomic clock pumped by a semiconductor laser

Minoru Hashimoto, Motoichi Ohtsu

Precise measurement of the shift (i.e. microwave frequency shift induced by the electric field of the pumping light) in a rubidium atomic clock pumped by a semiconductor laser is discussed. The spectral lineshape of the microwave resonance, which is used as a frequency discriminator for the atomic clock in the optical microwave double resonance experiment, depends strongly on the spatial distribution of the laser beam intensity, laser frequency detuning, and modulation parameters of the microwave frequency. Based on measurements of the deformation of the resonance lineshape, a self-tuning system was built to compensate for the effect of light shift. As a result of controlling the laser frequency with this system, long-term drift of the microwave frequency as low as 6.3*10/sup -13//h was obtained.>

IEEE Transactions on Instrumentation and Measurement•Jun 1, 1990•24 citations

Study of Rb 0-0 hyperfine double-resonance transition in a wall-coated cell

Thejesh Bandi, C. Affolderbach, G. Mileti

In this paper, we present our studies on double resonance using atomic 87Rb in a wall-coated cell, in view of applications in a laser-pumped Rb atomic frequency standard. We study the systematic clock frequency shifts in a wall-coated cell, such as light shift, microwave power shift [11, 12] and shift due to cell temperature [13] (for the cell body, and for the Rb reservoir, also called the cell stem). We also report on our clock stability measurement using the wallcoated cell in DR scheme, and discuss the influence of the shift parameters first on the frequency stability of the clock.

European Frequency and Time Forum•Apr 1, 2010•5 citations

Cell-based stabilized laser sources and light-shifts in pulsed Rb atomic clocks

Nil Almat, William Moreno, Matthieu Pellaton +4 more

We report on a narrow-linewidth diode laser source emitting at 780 nm, based on frequency doubling from 1.56 μm, which is frequency stabilized on the D2 transition line of Rubidium (Rb). This compact laser source shows a frequency stability of 2·10-12at 1 s and-12for τ up to 104s. This laser source is evaluated in a modular four-laser setup to identify and locate the sources of instabilities. In view of the lasers' applications to vapor-cell Rb atomic clocks, we also studied the various light-shift coefficients in a pulsed optically-pumped Rb clock. Finally, we evaluate the impact of the frequency and intensity instabilities of the frequency-doubled optical sources on the clock stability.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•Jul 1, 2017•1 citation

Fundamental characteristics of a laser pumped Rb atomic oscillator

Isao MATSUDA, Shizuo Yamaguchi, 林原, 毅 +1 more

The operation of a Rb atomic oscillator optically pumped by semiconductor laser was investigated. The laser frequency was stabilized to the Rb D_1 line by using a Rb cell containing the natural Rb and the mixed gas of Argon and Nitrogen (Ar/N_2=1.25, 37 Torr). The optical-microwave double resonance signal was also obtained by the same cell. The microwave resonant frequency shifts due to the Power, the pumping frequency offset and the beam diameter of the pumping laser were measured.

•Jan 1, 1987•0 citations

A laser optically-pumped Rubidium vapour-cell frequency standard using a DFB laser diode

C. Affolderbach, G. Mileti, Fabien Droz

A laser optically-pumped vapour-cell atomic frequency standard ("Rb clock") using a DFB laser diode as pump light source is presented. The Rb clock is based on probing the ground-state hyperfine "clock" transition at 6.8 GHz of atomic87Rb, by optical-microwave double-resonance technique. The frequency stability of the clock is measured.

Conference on Lasers and Electro-Optics Europe & European Quantum Electronics Conference (CLEO/Europe-EQEC)•Jun 1, 2007•0 citations
ln recent years, laser pumped Rb atomic clocks have been numerously studied and developed to reduce "light shift" and increase the accuracy and stability of the frequency. Previously, we reoorted on the measurement of the linewidths and S/N of the optical-microwave double resonance signal and the light shift in a Rb atomic clock pumped by a stabilized diode laser. In this paper, the light shift was numerically calculated by using the theory proposed by Cohen-Tannoudji & Barrat. Furthermore, contributions of the laser power and frequency detuning to the light shift were also estimated to attain the microwave frequency stability as high as 10^<-12>.
The /sup 87/Rb cell frequency standard, optically pumped by a laser diode, is of great interest in the development of high short-term stability oscillators. We report experiments performed on a rubidium cell prototype aiming at evaluate the transfer of the laser noise to the hyperfine clock transition via the light shift effect, which appears to be the main contribution to the observed short term frequency stability in this kind of standard. Pulsed optical pumping will also be examined in order to strongly reduce the light shift effect and to achieve the theoretical limit never approached up to now despite the strong detected microwave signals.
Precise measurement of the shift (i.e. microwave frequency shift induced by the electric field of the pumping light) in a rubidium atomic clock pumped by a semiconductor laser is discussed. The spectral lineshape of the microwave resonance, which is used as a frequency discriminator for the atomic clock in the optical microwave double resonance experiment, depends strongly on the spatial distribution of the laser beam intensity, laser frequency detuning, and modulation parameters of the microwave frequency. Based on measurements of the deformation of the resonance lineshape, a self-tuning system was built to compensate for the effect of light shift. As a result of controlling the laser frequency with this system, long-term drift of the microwave frequency as low as 6.3*10/sup -13//h was obtained.>
In this paper, we present our studies on double resonance using atomic 87Rb in a wall-coated cell, in view of applications in a laser-pumped Rb atomic frequency standard. We study the systematic clock frequency shifts in a wall-coated cell, such as light shift, microwave power shift [11, 12] and shift due to cell temperature [13] (for the cell body, and for the Rb reservoir, also called the cell stem). We also report on our clock stability measurement using the wallcoated cell in DR scheme, and discuss the influence of the shift parameters first on the frequency stability of the clock.
We report on a narrow-linewidth diode laser source emitting at 780 nm, based on frequency doubling from 1.56 μm, which is frequency stabilized on the D2 transition line of Rubidium (Rb). This compact laser source shows a frequency stability of 2·10-12at 1 s and-12for τ up to 104s. This laser source is evaluated in a modular four-laser setup to identify and locate the sources of instabilities. In view of the lasers' applications to vapor-cell Rb atomic clocks, we also studied the various light-shift coefficients in a pulsed optically-pumped Rb clock. Finally, we evaluate the impact of the frequency and intensity instabilities of the frequency-doubled optical sources on the clock stability.