Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

IEEE Transactions on Instrumentation and Measurement

A novel method to compensate for the effect of light shift in a rubidium atomic clock pumped by a semiconductor laser

Minoru Hashimoto, Motoichi Ohtsu

Published Jun 1, 1990• 27 citations
Publisher

Abstract

Precise measurement of the shift (i.e. microwave frequency shift induced by the electric field of the pumping light) in a rubidium atomic clock pumped by a semiconductor laser is discussed. The spectral lineshape of the microwave resonance, which is used as a frequency discriminator for the atomic clock in the optical microwave double resonance experiment, depends strongly on the spatial distribution of the laser beam intensity, laser frequency detuning, and modulation parameters of the microwave frequency. Based on measurements of the deformation of the resonance lineshape, a self-tuning system was built to compensate for the effect of light shift. As a result of controlling the laser frequency with this system, long-term drift of the microwave frequency as low as 6.3*10/sup -13//h was obtained.>

DOI
10.1109/19.106272

Related papers

Modulation transfer and optical Stark effect in a rubidium atomic clock pumped by a semiconductor laser

Minora Hashimoto, Motoichi Ohtsu

Novel spectral line shapes of optical-microwave double resonance with an extremely narrow line width were observed in a rubidium atomic clock pumped by a semiconductor laser. It was confirmed that these novel spectral line shapes of double resonance were due to the modulation-transfer effect. These spectral line shapes were calculated by solving the equation of motion of the density matrix that describes the modulation-transfer process. The calculated results agree with the experimental results. By using the calculated results of the influence of the optical Stark effect on these spectral line shapes, characteristics of the inhomogeneous light shift were evaluated quantitatively for the frequency-modulated microwave. Furthermore, optimum values of modulation parameters were found by computer simulation in order to obtain the highest microwave frequency stability of the atomic clocks. An experiment was carried out employing these optimum parameters, and a short-term frequency stability as high as σy(τ) = 7.9 × 10−13τ−1/2 was obtained, where τ is an integration time of measurement.

Journal of the Optical Society of America B•Oct 1, 1989•27 citations

Experiments on a semiconductor laser pumped rubidium atomic clock

Minoru Hashimoto, Motoichi Ohtsu

Experiments were carried out to evaluate the performances of a semiconductor laser pumped rubidium (87Rb) atomic clock. Two kinds of Rb gas cells were used and their performances were compared [gas cell A (natural rubidium (87Rb/85Rb =\frac{3}{7}) and buffer gases) and gas cell B (87Rb and buffer gases)]. The highest microwave frequency stabilities were estimated as3.4 \times 10^{-12} \tau^{-1/2}and2.7 \times 10^{-12} \tau^{-1/2}at the optimal gas cell temperatures of 60°C and 48°C for the gas cellsAandB, respectively (τ: integration time). The light shift, i.e., microwave frequency shift induced by laser light, was measured as -0.50 Hz/MHz and -0.11 Hz/MHz for the gas cellsAandBat their optimal operating conditions given above. As an improved experiment by utilizing high temporal coherence of the laser, a novel double resonance spectral line shape with a drastically narrower linewidth was demonstrated. A technique, similar to FM laser spectroscopy, was employed for this purpose by utilizing laser FM sidebands which are induced by microwave frequency modulation and nonlinear susceptibility of three-level87Rb atoms. The minimum linewidth obtained was 20 Hz, which can be used as a sensitive frequency discriminator for an improved87Rb atomic clock.

IEEE Journal of Quantum Electronics•Apr 1, 1987•63 citations

Analysis of the light shift in a Rb atomic clock pumped by detuned laser

勲 松田, 静夫 山口, Isao Matsuda +1 more

ln recent years, laser pumped Rb atomic clocks have been numerously studied and developed to reduce "light shift" and increase the accuracy and stability of the frequency. Previously, we reoorted on the measurement of the linewidths and S/N of the optical-microwave double resonance signal and the light shift in a Rb atomic clock pumped by a stabilized diode laser. In this paper, the light shift was numerically calculated by using the theory proposed by Cohen-Tannoudji & Barrat. Furthermore, contributions of the laser power and frequency detuning to the light shift were also estimated to attain the microwave frequency stability as high as 10^<-12>.

•Jan 1, 1992•0 citations

A frequency shift compensation method for light shift and vapor-cell temperature shift in atomic clocks

Dou Li, Kangqi Liu, Linzhen Zhao +1 more

Light shift and vapor-cell temperature shift are the two most significant factors dominating the long-term instability of compact atomic clocks. Due to the different physical mechanisms, there is not yet a solution that can effectively suppress the frequency shifts induced by these two effects. Here, we propose a 'resonance-offset' locking approach that compensates for the two physical frequency shifts. In this approach, the additional offset locking shift can effectively counteract the atomic resonance shifts arising from changes in vapor-cell temperature and light power, reducing the net impact on the clock's frequency to nearly zero. We have demonstrated this strategy on the 778 nm Rubidium two-photon optical frequency standard, successfully compensating for light shift and cell-temperature shift, respectively. This general method is particularly appealing for compact vapor-cell microwave and optical atomic clocks designed for the excellent stability rather than accuracy.

arXiv:2405.14281•May 23, 2024•2 citations

Simple method of light-shift suppression in optical pumping systems

B. H. McGuyer, Yuan‐Yu Jau, W. Happer

We report a simple method to suppress the light shift in optical pumping systems. This method uses only frequency modulation of a radio frequency or microwave source, which is used to excite an atomic resonance, to simultaneously lock the source frequency to the atomic resonance and lock the pumping light frequency to suppress the light shift. We experimentally validate the method in a vapor-cell atomic clock and verify the results through numerical simulation. This technique can be applied to many optical pumping systems that experience light shifts. It is especially useful for atomic frequency standards because it improves long-term performance, reduces the influence of the laser, and requires less equipment than previous methods.

arXiv:1302.4160•Applied Physics Letters•Jun 22, 2009•59 citations

Rubidium chip-scale atomic clock with improved long-term stability through light intensity optimization and compensation for laser frequency detuning

Yaolin Zhang, Wanpeng Yang, Shuangyou Zhang +1 more

We demonstrate the implementation of a Rb87 chip-scale atomic clock (CSAC) that has improved long-term stability. A simple method of reducing the frequency drift in the CSAC is proposed. As well as the well-known effect of light intensity on the clock frequency, our analysis shows that the frequency drift that is due to laser frequency detuning (LFD) variation originates from asymmetry in the coherent laser fields, and thus, we propose to actively compensate the clock frequency by using variations in the light intensity and LFD. We performed experiments to obtain precise clock frequency sensitivities to the light intensity and LFD, and the frequency drift was reduced from 7.1×10−11/day to 6.9×10−13/day with the frequency compensation method. Additionally, the CSAC with an optimized configuration of light intensity and microwave power showed evident long-term frequency stability improvement, from 8.9×10−11 to 8.7×10−12 at 105 s. Therefore, our method is useful in reducing the frequency drift of CSACs and could be potentially used in applications that require moderate long-term stability of sub-1×10−11.

Journal of the Optical Society of America B•Jul 25, 2016•62 citations
Precise measurement of the shift (i.e. microwave frequency shift induced by the electric field of the pumping light) in a rubidium atomic clock pumped by a semiconductor laser is discussed. The spectral lineshape of the microwave resonance, which is used as a frequency discriminator for the atomic clock in the optical microwave double resonance experiment, depends strongly on the spatial distribution of the laser beam intensity, laser frequency detuning, and modulation parameters of the microwave frequency. Based on measurements of the deformation of the resonance lineshape, a self-tuning system was built to compensate for the effect of light shift. As a result of controlling the laser frequency with this system, long-term drift of the microwave frequency as low as 6.3*10/sup -13//h was obtained.>
Novel spectral line shapes of optical-microwave double resonance with an extremely narrow line width were observed in a rubidium atomic clock pumped by a semiconductor laser. It was confirmed that these novel spectral line shapes of double resonance were due to the modulation-transfer effect. These spectral line shapes were calculated by solving the equation of motion of the density matrix that describes the modulation-transfer process. The calculated results agree with the experimental results. By using the calculated results of the influence of the optical Stark effect on these spectral line shapes, characteristics of the inhomogeneous light shift were evaluated quantitatively for the frequency-modulated microwave. Furthermore, optimum values of modulation parameters were found by computer simulation in order to obtain the highest microwave frequency stability of the atomic clocks. An experiment was carried out employing these optimum parameters, and a short-term frequency stability as high as σy(τ) = 7.9 × 10−13τ−1/2 was obtained, where τ is an integration time of measurement.
Experiments were carried out to evaluate the performances of a semiconductor laser pumped rubidium (87Rb) atomic clock. Two kinds of Rb gas cells were used and their performances were compared [gas cell A (natural rubidium (87Rb/85Rb =\frac{3}{7}) and buffer gases) and gas cell B (87Rb and buffer gases)]. The highest microwave frequency stabilities were estimated as3.4 \times 10^{-12} \tau^{-1/2}and2.7 \times 10^{-12} \tau^{-1/2}at the optimal gas cell temperatures of 60°C and 48°C for the gas cellsAandB, respectively (τ: integration time). The light shift, i.e., microwave frequency shift induced by laser light, was measured as -0.50 Hz/MHz and -0.11 Hz/MHz for the gas cellsAandBat their optimal operating conditions given above. As an improved experiment by utilizing high temporal coherence of the laser, a novel double resonance spectral line shape with a drastically narrower linewidth was demonstrated. A technique, similar to FM laser spectroscopy, was employed for this purpose by utilizing laser FM sidebands which are induced by microwave frequency modulation and nonlinear susceptibility of three-level87Rb atoms. The minimum linewidth obtained was 20 Hz, which can be used as a sensitive frequency discriminator for an improved87Rb atomic clock.
ln recent years, laser pumped Rb atomic clocks have been numerously studied and developed to reduce "light shift" and increase the accuracy and stability of the frequency. Previously, we reoorted on the measurement of the linewidths and S/N of the optical-microwave double resonance signal and the light shift in a Rb atomic clock pumped by a stabilized diode laser. In this paper, the light shift was numerically calculated by using the theory proposed by Cohen-Tannoudji & Barrat. Furthermore, contributions of the laser power and frequency detuning to the light shift were also estimated to attain the microwave frequency stability as high as 10^<-12>.
Light shift and vapor-cell temperature shift are the two most significant factors dominating the long-term instability of compact atomic clocks. Due to the different physical mechanisms, there is not yet a solution that can effectively suppress the frequency shifts induced by these two effects. Here, we propose a 'resonance-offset' locking approach that compensates for the two physical frequency shifts. In this approach, the additional offset locking shift can effectively counteract the atomic resonance shifts arising from changes in vapor-cell temperature and light power, reducing the net impact on the clock's frequency to nearly zero. We have demonstrated this strategy on the 778 nm Rubidium two-photon optical frequency standard, successfully compensating for light shift and cell-temperature shift, respectively. This general method is particularly appealing for compact vapor-cell microwave and optical atomic clocks designed for the excellent stability rather than accuracy.
We report a simple method to suppress the light shift in optical pumping systems. This method uses only frequency modulation of a radio frequency or microwave source, which is used to excite an atomic resonance, to simultaneously lock the source frequency to the atomic resonance and lock the pumping light frequency to suppress the light shift. We experimentally validate the method in a vapor-cell atomic clock and verify the results through numerical simulation. This technique can be applied to many optical pumping systems that experience light shifts. It is especially useful for atomic frequency standards because it improves long-term performance, reduces the influence of the laser, and requires less equipment than previous methods.
We demonstrate the implementation of a Rb87 chip-scale atomic clock (CSAC) that has improved long-term stability. A simple method of reducing the frequency drift in the CSAC is proposed. As well as the well-known effect of light intensity on the clock frequency, our analysis shows that the frequency drift that is due to laser frequency detuning (LFD) variation originates from asymmetry in the coherent laser fields, and thus, we propose to actively compensate the clock frequency by using variations in the light intensity and LFD. We performed experiments to obtain precise clock frequency sensitivities to the light intensity and LFD, and the frequency drift was reduced from 7.1×10−11/day to 6.9×10−13/day with the frequency compensation method. Additionally, the CSAC with an optimized configuration of light intensity and microwave power showed evident long-term frequency stability improvement, from 8.9×10−11 to 8.7×10−12 at 105 s. Therefore, our method is useful in reducing the frequency drift of CSACs and could be potentially used in applications that require moderate long-term stability of sub-1×10−11.