Instruments and Experimental Techniques

Objective Lens with a Numerical Aperture of 0.4 for Optical Tweezers for Ytterbium Atoms

Artem A. Golovizin, N. Yu. Shlykov, M. O. Yaushev, S. V. Klimov, A. A. Dvurechenskii, Д. О. Трегубов, N. Kolachevsky

Published Oct 1, 2025• 1 citation
Publisher

Abstract

Abstract A wide-aperture objective lens (OL) is developed for experiments with ultracold ytterbium atoms and its characteristics are described. The OL consists of standard models of an aspherical lens and an achromatic doublet, has a numerical aperture of 0.4 and a working distance of 30–35 mm, and is adjusted for a 5‑mm-thick vacuum window. The formation of optical tweezers at a wavelength of 759 nm with a waist radius of 0.92 μm and an image of the optical-tweezers plane at a wavelength of 556 nm with a resolution of several microns has been experimentally demonstrated. The developed OL is simple to manufacture and suitable for use in a wide range of experiments (including those involving thulium atoms), in which the geometry of the vacuum chamber requires the use of an OL with a long working distance.

DOI
10.1134/s0020441225701076

Related papers

High-resolution imaging of Rydberg atoms in optical lattices using an aspheric-lens objective in vacuum

Chuyang Shen, Cheng Chen, Xiaoling Wu +4 more

We present a high-resolution, simple, and versatile system for imaging ultracold Rydberg atoms in optical lattices. The imaging objective is a single aspheric lens [with a working distance of 20.6 mm and a numerical aperture (NA) of 0.51] placed inside the vacuum chamber. Adopting a large-working-distance lens leaves room for electrodes and electrostatic shields to control electric fields around Rydberg atoms. With this setup, we achieve a Rayleigh resolution of 1.10 μm or 1.41λ (λ = 780 nm), limited by the NA of the aspheric lens. For systems of highly excited Rydberg states with blockade radii greater than a few μm, the resolution achieved is sufficient for studying many physical processes of interest.

arXiv:2002.11906•Review of Scientific Instruments•Jun 1, 2020•4 citations

High-resolution ex vacuo objective for cold atom experiments

Xiao Min Li, Feng Zhou, Ke Min +4 more

We present a versatile and cost-efficient objective with a five-lens configuration, which consists completely of commercial singlets. The home-built objective has a numerical aperture (NA) of 0.44 and a long working distance of 35.9 mm, making it suitable for ex vacuo utilization. A diffraction-limited resolution of 1.08 μm and a field of view of about 210 μm are achieved when a 780 nm light passes through a 5 mm thick vacuum window. Moreover, such a design can be well adapted to a broad range of laser wavelengths (560-1000 nm) and vacuum window thicknesses (0-6 mm) by simply modifying one lens spacing, while maintaining a NA of above 0.43. The characteristics of the objective are evaluated experimentally, which are in good agreement with the simulations. Also, the objective has been successfully used for single-atom trapping and detecting in experiments. We believe that it will find more applications in various cold atom experiments.

Applied Optics•Sep 6, 2018•17 citations

Single-Atom Trapping in a Metasurface-Lens Optical Tweezer

Ting‐Wei Hsu, Wenqi Zhu, Tobias Thiele +4 more

Optical metasurfaces of subwavelength pillars have provided new capabilities for the versatile definition of the amplitude, phase, and polarization of light.In this work, we demonstrate that an efficient dielectric metasurface lens can be used to trap and image single neutral atoms with a long working distance from the lens of 3 mm.We characterize the high-numerical-aperture optical tweezers using the trapped atoms and compare with numerical computations of the metasurface-lens performance.We predict that future metasurfaces for atom trapping will be able to leverage multiple ongoing developments in metasurface design and enable multifunctional control in complex quantum information experiments with neutral-atom arrays.

arXiv:2110.11559•PRX Quantum•Aug 1, 2022•69 citations

Long working distance objective lenses for single atom trapping and imaging

Jonathan D. Pritchard, Joshua Isaacs, Mark E. Saffman

We present a pair of optimized objective lenses with long working distances of 117 mm and 65 mm, respectively, that offer diffraction limited performance for both Cs and Rb wavelengths when imaging through standard vacuum windows. The designs utilise standard catalog lens elements to provide a simple and cost-effective solution. Objective 1 provides NA = 0.175 offering 3 μm resolution whilst objective 2 is optimized for high collection efficiency with NA = 0.29 and 1.8 μm resolution. This flexible design can be further extended for use at shorter wavelengths by simply re-optimising the lens separations.

arXiv:1605.09051•Review of Scientific Instruments•Jul 1, 2016•24 citations

Diffraction-limited optics for single-atom manipulation

Yvan R. P. Sortais, H. Marion, Charles Tuchendler +8 more

We present an optical system designed to capture and observe a single neutral atom in an optical dipole trap, created by focusing a laser beam using a large-numerical-aperture $(\mathrm{NA}=0.5)$ aspheric lens. We experimentally evaluate the performance of the optical system and show that it is diffraction limited over a broad spectral range $(\ensuremath{\sim}200\phantom{\rule{0.3em}{0ex}}\mathrm{nm})$ with a large transverse field $(\ifmmode\pm\else\textpm\fi{}25\phantom{\rule{0.3em}{0ex}}\ensuremath{\mu}\mathrm{m})$. The optical tweezer created at the focal point of the lens is able to trap single atoms of $^{87}\mathrm{Rb}$ and to detect them individually with a large collection efficiency. We measure the oscillation frequency of the atom in the dipole trap and use this value as an independent determination of the waist of the optical tweezer. Finally, we produce with the same lens two dipole traps separated by $2.2\phantom{\rule{0.3em}{0ex}}\ensuremath{\mu}\mathrm{m}$ and show that the imaging system can resolve the two atoms.

arXiv:quant-ph/0610071•Physical Review A•Jan 8, 2007•129 citations

Design of compact high resolution imaging system for cold atom experiments

Xiaoyang Shen, Yi-Hao Cheng, Xia Lin

In cold atom experiments, high resolution imaging systems have been used to extract in-situ density information when studying quantum gases, which is one of the hot topics in this field. Such a system is usually called “quantum-gas microscope”. In order to achieve a long working distance and large magnification, high resolution imaging of cold atoms through a vacuum window usually requires a long distance between the atoms and the camera. However, due to space limitation caused by a large number of nearby optical elements, it may be difficult to realize a long imaging system, which is a common case in cold atom experiments. Herein we present an imaging system that can achieve a short distance between the atoms and the image plane with diffraction-limited 1 μm resolution and 50 magnification. The telephoto lens design is adopted to reduce the back focal length and enhance the pointing stability of the imaging lens. The system is optimized at an operating wavelength of 767 nm and corrects aberrations induced by a 5-mm-thick silica vacuum window. At a working distance of 32 mm, a diffraction-limited field of view of 408 μm is obtained. The simulation result shows that by changing the air space between lenses, our design operates across a wide range of window thicknesses (0–15 mm), which makes it robust enough to be used in typical laboratories. This compact imaging system is made from commercial on-shelf Φ2 in (1 in = 2.54 cm) singlets and consists of two components: a microscope objective with a numerical aperture of 0.47 and a telephoto objective with a long effective focal length of 1826 mm. Both are infinitely corrected, allowing the distance between them to be adjusted to insert optical elements for irradiating atoms with laser beams of different wavelengths without affecting the imaging resolution. Taking the manufacturing and assembling tolerances into consideration, the Monte Carlo analyses show that more than 95% of the random samples are diffraction-limited within the field of view. This high success rate ensures that these two objectives can be achieved easily in the experiment. Combined with its performance with other wavelengths (470–1064 nm), this imaging system can be used for imaging different atom species, such as sodium, lithium, and cesium.

Acta Physica Sinica•Dec 15, 2023•0 citations
Abstract A wide-aperture objective lens (OL) is developed for experiments with ultracold ytterbium atoms and its characteristics are described. The OL consists of standard models of an aspherical lens and an achromatic doublet, has a numerical aperture of 0.4 and a working distance of 30–35 mm, and is adjusted for a 5‑mm-thick vacuum window. The formation of optical tweezers at a wavelength of 759 nm with a waist radius of 0.92 μm and an image of the optical-tweezers plane at a wavelength of 556 nm with a resolution of several microns has been experimentally demonstrated. The developed OL is simple to manufacture and suitable for use in a wide range of experiments (including those involving thulium atoms), in which the geometry of the vacuum chamber requires the use of an OL with a long working distance.
We present a high-resolution, simple, and versatile system for imaging ultracold Rydberg atoms in optical lattices. The imaging objective is a single aspheric lens [with a working distance of 20.6 mm and a numerical aperture (NA) of 0.51] placed inside the vacuum chamber. Adopting a large-working-distance lens leaves room for electrodes and electrostatic shields to control electric fields around Rydberg atoms. With this setup, we achieve a Rayleigh resolution of 1.10 μm or 1.41λ (λ = 780 nm), limited by the NA of the aspheric lens. For systems of highly excited Rydberg states with blockade radii greater than a few μm, the resolution achieved is sufficient for studying many physical processes of interest.
We present a versatile and cost-efficient objective with a five-lens configuration, which consists completely of commercial singlets. The home-built objective has a numerical aperture (NA) of 0.44 and a long working distance of 35.9 mm, making it suitable for ex vacuo utilization. A diffraction-limited resolution of 1.08 μm and a field of view of about 210 μm are achieved when a 780 nm light passes through a 5 mm thick vacuum window. Moreover, such a design can be well adapted to a broad range of laser wavelengths (560-1000 nm) and vacuum window thicknesses (0-6 mm) by simply modifying one lens spacing, while maintaining a NA of above 0.43. The characteristics of the objective are evaluated experimentally, which are in good agreement with the simulations. Also, the objective has been successfully used for single-atom trapping and detecting in experiments. We believe that it will find more applications in various cold atom experiments.
Optical metasurfaces of subwavelength pillars have provided new capabilities for the versatile definition of the amplitude, phase, and polarization of light.In this work, we demonstrate that an efficient dielectric metasurface lens can be used to trap and image single neutral atoms with a long working distance from the lens of 3 mm.We characterize the high-numerical-aperture optical tweezers using the trapped atoms and compare with numerical computations of the metasurface-lens performance.We predict that future metasurfaces for atom trapping will be able to leverage multiple ongoing developments in metasurface design and enable multifunctional control in complex quantum information experiments with neutral-atom arrays.
We present a pair of optimized objective lenses with long working distances of 117 mm and 65 mm, respectively, that offer diffraction limited performance for both Cs and Rb wavelengths when imaging through standard vacuum windows. The designs utilise standard catalog lens elements to provide a simple and cost-effective solution. Objective 1 provides NA = 0.175 offering 3 μm resolution whilst objective 2 is optimized for high collection efficiency with NA = 0.29 and 1.8 μm resolution. This flexible design can be further extended for use at shorter wavelengths by simply re-optimising the lens separations.
We present an optical system designed to capture and observe a single neutral atom in an optical dipole trap, created by focusing a laser beam using a large-numerical-aperture (NA=0.5)(\mathrm{NA}=0.5)(NA=0.5) aspheric lens. We experimentally evaluate the performance of the optical system and show that it is diffraction limited over a broad spectral range $(\ensuremath{\sim}200\phantom{\rule{0.3em}{0ex}}\mathrm{nm})$ with a large transverse field $(\ifmmode\pm\else\textpm\fi{}25\phantom{\rule{0.3em}{0ex}}\ensuremath{\mu}\mathrm{m})$. The optical tweezer created at the focal point of the lens is able to trap single atoms of 87Rb^{87}\mathrm{Rb}87Rb and to detect them individually with a large collection efficiency. We measure the oscillation frequency of the atom in the dipole trap and use this value as an independent determination of the waist of the optical tweezer. Finally, we produce with the same lens two dipole traps separated by $2.2\phantom{\rule{0.3em}{0ex}}\ensuremath{\mu}\mathrm{m}$ and show that the imaging system can resolve the two atoms.
In cold atom experiments, high resolution imaging systems have been used to extract in-situ density information when studying quantum gases, which is one of the hot topics in this field. Such a system is usually called “quantum-gas microscope”. In order to achieve a long working distance and large magnification, high resolution imaging of cold atoms through a vacuum window usually requires a long distance between the atoms and the camera. However, due to space limitation caused by a large number of nearby optical elements, it may be difficult to realize a long imaging system, which is a common case in cold atom experiments. Herein we present an imaging system that can achieve a short distance between the atoms and the image plane with diffraction-limited 1 μm resolution and 50 magnification. The telephoto lens design is adopted to reduce the back focal length and enhance the pointing stability of the imaging lens. The system is optimized at an operating wavelength of 767 nm and corrects aberrations induced by a 5-mm-thick silica vacuum window. At a working distance of 32 mm, a diffraction-limited field of view of 408 μm is obtained. The simulation result shows that by changing the air space between lenses, our design operates across a wide range of window thicknesses (0–15 mm), which makes it robust enough to be used in typical laboratories. This compact imaging system is made from commercial on-shelf Φ2 in (1 in = 2.54 cm) singlets and consists of two components: a microscope objective with a numerical aperture of 0.47 and a telephoto objective with a long effective focal length of 1826 mm. Both are infinitely corrected, allowing the distance between them to be adjusted to insert optical elements for irradiating atoms with laser beams of different wavelengths without affecting the imaging resolution. Taking the manufacturing and assembling tolerances into consideration, the Monte Carlo analyses show that more than 95% of the random samples are diffraction-limited within the field of view. This high success rate ensures that these two objectives can be achieved easily in the experiment. Combined with its performance with other wavelengths (470–1064 nm), this imaging system can be used for imaging different atom species, such as sodium, lithium, and cesium.