Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Acta Physica Sinica

Design of compact high resolution imaging system for cold atom experiments

Xiaoyang Shen, Yi-Hao Cheng, Xia Lin

Published Dec 15, 2023• 0 citations
Publisher

Abstract

In cold atom experiments, high resolution imaging systems have been used to extract in-situ density information when studying quantum gases, which is one of the hot topics in this field. Such a system is usually called “quantum-gas microscope”. In order to achieve a long working distance and large magnification, high resolution imaging of cold atoms through a vacuum window usually requires a long distance between the atoms and the camera. However, due to space limitation caused by a large number of nearby optical elements, it may be difficult to realize a long imaging system, which is a common case in cold atom experiments. Herein we present an imaging system that can achieve a short distance between the atoms and the image plane with diffraction-limited 1 μm resolution and 50 magnification. The telephoto lens design is adopted to reduce the back focal length and enhance the pointing stability of the imaging lens. The system is optimized at an operating wavelength of 767 nm and corrects aberrations induced by a 5-mm-thick silica vacuum window. At a working distance of 32 mm, a diffraction-limited field of view of 408 μm is obtained. The simulation result shows that by changing the air space between lenses, our design operates across a wide range of window thicknesses (0–15 mm), which makes it robust enough to be used in typical laboratories. This compact imaging system is made from commercial on-shelf Φ2 in (1 in = 2.54 cm) singlets and consists of two components: a microscope objective with a numerical aperture of 0.47 and a telephoto objective with a long effective focal length of 1826 mm. Both are infinitely corrected, allowing the distance between them to be adjusted to insert optical elements for irradiating atoms with laser beams of different wavelengths without affecting the imaging resolution. Taking the manufacturing and assembling tolerances into consideration, the Monte Carlo analyses show that more than 95% of the random samples are diffraction-limited within the field of view. This high success rate ensures that these two objectives can be achieved easily in the experiment. Combined with its performance with other wavelengths (470–1064 nm), this imaging system can be used for imaging different atom species, such as sodium, lithium, and cesium.

DOI
10.7498/aps.73.20231689

Related papers

A versatile high resolution objective for imaging quantum gases

L. M. Bennie, Philip T. Starkey, M. Jasperse +3 more

We present a high resolution objective lens made entirely from catalog singlets that has a numerical aperture of 0.36. It corrects for aberrations introduced by a glass window and has a long working distance of 35 mm, making it suitable for imaging objects within a vacuum system. This offers simple high resolution imaging for many in the quantum gas community. The objective achieves a resolution of 1.3 μm at the design wavelength of 780 nm, and a diffraction-limited field of view of 360 μm when imaging through a 5 mm thick window. Images of a resolution target and a pinhole show quantitative agreement with the simulated lens performance. The objective is suitable for diffraction-limited monochromatic imaging on the D2 line of all the alkalis by changing only the aperture diameter, retaining numerical apertures above 0.32. The design corrects for window thicknesses of up to 15 mm if the singlet spacings are modified.

arXiv:1302.4166•Optics Express•Apr 4, 2013•23 citations

An adaptable two-lens high-resolution objective for single-site resolved imaging of atoms in optical lattices

Matthias W. Gempel, Torsten Hartmann, Torben Schulze +3 more

In this paper, we present a high-resolution, simple, and versatile imaging system for single-site resolved imaging of atoms in optical lattices. The system, which relies on an adaptable infinite conjugate two-lens design, has a numerical aperture of 0.52, which can in the ideal case be further extended to 0.57. It is optimized for imaging on the sodium D2-line but allows us to tune the objective’s diffraction limited performance between 400 nm and 1000 nm by changing the distance between the two lenses. Furthermore, the objective is designed to be integrated into a typical atomic physics vacuum apparatus where the operating distance can be large (>20 mm) and diffraction limited performance still needs to be achieved when imaging through thick vacuum windows (6 mm to 10 mm). Imaging gold nanoparticles, using a wavelength of 589 nm which corresponds to the D2-line of sodium atoms, we measure diffraction limited performance and a resolution corresponding to an Airy radius of less than 0.7 µm, enabling potential single-site resolution in the commonly used 532 nm optical lattice spacing.

Review of Scientific Instruments•May 1, 2019•8 citations

Quantum gas microscope assisted with T-shape vacuum viewports

Ye Tian, Zhongchi Zhang, Jilai Ye +3 more

A quantum gas microscope plays an important role in cold-atom experiments, which provides a high-resolution imaging of the spatial distributions of cold atoms. Here we design, build and calibrate an integrated microscope for quantum gases with all the optical components fixed outside the vacuum chamber. It provides large numerical aperture (NA) of 0.75, as well as good optical access from side for atom loading in cold-atom experiments due to long working distance (7 mm fused silica+6 mm vacuum) of the microscope objective. We make a special design of the vacuum viewport with a T-shape window, to suppress the window flatness distortion introduced by the metal-glass binding process, and protect the high-resolution imaging from distortions due to unflattened window. The achieved Strehl ratio is 0.9204 using scanning-near-field microscopy (SNOM) fiber coupling incoherent light as point light source.

Optics Express•Sep 14, 2022•0 citations

High-resolution ex vacuo objective for cold atom experiments

Xiao Min Li, Feng Zhou, Ke Min +4 more

We present a versatile and cost-efficient objective with a five-lens configuration, which consists completely of commercial singlets. The home-built objective has a numerical aperture (NA) of 0.44 and a long working distance of 35.9 mm, making it suitable for ex vacuo utilization. A diffraction-limited resolution of 1.08 μm and a field of view of about 210 μm are achieved when a 780 nm light passes through a 5 mm thick vacuum window. Moreover, such a design can be well adapted to a broad range of laser wavelengths (560-1000 nm) and vacuum window thicknesses (0-6 mm) by simply modifying one lens spacing, while maintaining a NA of above 0.43. The characteristics of the objective are evaluated experimentally, which are in good agreement with the simulations. Also, the objective has been successfully used for single-atom trapping and detecting in experiments. We believe that it will find more applications in various cold atom experiments.

Applied Optics•Sep 6, 2018•17 citations

Microscopic trapping and high-resolution imaging of ultra cold Rydberg atoms

Harish Rathore

In this work we describe the design and implementation of an optical system that enables the study of the interactions of Rydberg atoms or other Rydberg species in well-defined geometries. To understand and observe the dynamics of Rydberg interactions, the ability to engineer different arrangements of microscopic cold atom traps and manipulate their positions with a precision of a few microns is essential. This is accomplished by a custom designed high-numerical-aperture long-working-distance objective lens and a spatial light modulator device to control the phase of an incoming optical beam. Several different trap geometries have been realized, with a spatial resolution of a few microns, including a 1-dimensional chain, a 2-dimensional square grid, and a circular array of traps. The objective lens has been designed to provide diffraction limited performance at multiple wavelengths facilitating the creation of not only micron-scale atom traps but also the fluorescence imaging of trapped atoms. The system enables precise control over trap positions, and hence the locations at which atoms might be excited, with applications in, for example, the study of long-range interactions between Rydberg atoms, the creation of long-range Rydberg molecules, the implementation of qubits for quantum computing based on Rydberg atoms, and in quantum simulation.

•Jul 22, 2020•0 citations

A high resolution ion microscope for cold atoms

Markus Stecker, Hannah Schefzyk, József Fortágh +1 more

We report on an ion-optical system that serves as a microscope for ultracold ground state and Rydberg atoms. The system is designed to achieve a magnification of up to 1000 and a spatial resolution in the 100 nm range, thereby surpassing many standard imaging techniques for cold atoms. The microscope consists of four electrostatic lenses and a microchannel plate in conjunction with a delay line detector in order to achieve single particle sensitivity with high temporal and spatial resolution. We describe the design process of the microscope including ion-optical simulations of the imaging system and characterize aberrations and the resolution limit. Furthermore, we present the experimental realization of the microscope in a cold atom setup and investigate its performance by patterned ionization with a structure size down to 2.7 μ m. The microscope meets the requirements for studying various many-body effects, ranging from correlations in cold quantum gases up to Rydberg molecule formation.

arXiv:1701.02915•New Journal of Physics•Apr 13, 2017•28 citations
In cold atom experiments, high resolution imaging systems have been used to extract in-situ density information when studying quantum gases, which is one of the hot topics in this field. Such a system is usually called “quantum-gas microscope”. In order to achieve a long working distance and large magnification, high resolution imaging of cold atoms through a vacuum window usually requires a long distance between the atoms and the camera. However, due to space limitation caused by a large number of nearby optical elements, it may be difficult to realize a long imaging system, which is a common case in cold atom experiments. Herein we present an imaging system that can achieve a short distance between the atoms and the image plane with diffraction-limited 1 μm resolution and 50 magnification. The telephoto lens design is adopted to reduce the back focal length and enhance the pointing stability of the imaging lens. The system is optimized at an operating wavelength of 767 nm and corrects aberrations induced by a 5-mm-thick silica vacuum window. At a working distance of 32 mm, a diffraction-limited field of view of 408 μm is obtained. The simulation result shows that by changing the air space between lenses, our design operates across a wide range of window thicknesses (0–15 mm), which makes it robust enough to be used in typical laboratories. This compact imaging system is made from commercial on-shelf Φ2 in (1 in = 2.54 cm) singlets and consists of two components: a microscope objective with a numerical aperture of 0.47 and a telephoto objective with a long effective focal length of 1826 mm. Both are infinitely corrected, allowing the distance between them to be adjusted to insert optical elements for irradiating atoms with laser beams of different wavelengths without affecting the imaging resolution. Taking the manufacturing and assembling tolerances into consideration, the Monte Carlo analyses show that more than 95% of the random samples are diffraction-limited within the field of view. This high success rate ensures that these two objectives can be achieved easily in the experiment. Combined with its performance with other wavelengths (470–1064 nm), this imaging system can be used for imaging different atom species, such as sodium, lithium, and cesium.
We present a high resolution objective lens made entirely from catalog singlets that has a numerical aperture of 0.36. It corrects for aberrations introduced by a glass window and has a long working distance of 35 mm, making it suitable for imaging objects within a vacuum system. This offers simple high resolution imaging for many in the quantum gas community. The objective achieves a resolution of 1.3 μm at the design wavelength of 780 nm, and a diffraction-limited field of view of 360 μm when imaging through a 5 mm thick window. Images of a resolution target and a pinhole show quantitative agreement with the simulated lens performance. The objective is suitable for diffraction-limited monochromatic imaging on the D2 line of all the alkalis by changing only the aperture diameter, retaining numerical apertures above 0.32. The design corrects for window thicknesses of up to 15 mm if the singlet spacings are modified.
In this paper, we present a high-resolution, simple, and versatile imaging system for single-site resolved imaging of atoms in optical lattices. The system, which relies on an adaptable infinite conjugate two-lens design, has a numerical aperture of 0.52, which can in the ideal case be further extended to 0.57. It is optimized for imaging on the sodium D2-line but allows us to tune the objective’s diffraction limited performance between 400 nm and 1000 nm by changing the distance between the two lenses. Furthermore, the objective is designed to be integrated into a typical atomic physics vacuum apparatus where the operating distance can be large (>20 mm) and diffraction limited performance still needs to be achieved when imaging through thick vacuum windows (6 mm to 10 mm). Imaging gold nanoparticles, using a wavelength of 589 nm which corresponds to the D2-line of sodium atoms, we measure diffraction limited performance and a resolution corresponding to an Airy radius of less than 0.7 µm, enabling potential single-site resolution in the commonly used 532 nm optical lattice spacing.
A quantum gas microscope plays an important role in cold-atom experiments, which provides a high-resolution imaging of the spatial distributions of cold atoms. Here we design, build and calibrate an integrated microscope for quantum gases with all the optical components fixed outside the vacuum chamber. It provides large numerical aperture (NA) of 0.75, as well as good optical access from side for atom loading in cold-atom experiments due to long working distance (7 mm fused silica+6 mm vacuum) of the microscope objective. We make a special design of the vacuum viewport with a T-shape window, to suppress the window flatness distortion introduced by the metal-glass binding process, and protect the high-resolution imaging from distortions due to unflattened window. The achieved Strehl ratio is 0.9204 using scanning-near-field microscopy (SNOM) fiber coupling incoherent light as point light source.
We present a versatile and cost-efficient objective with a five-lens configuration, which consists completely of commercial singlets. The home-built objective has a numerical aperture (NA) of 0.44 and a long working distance of 35.9 mm, making it suitable for ex vacuo utilization. A diffraction-limited resolution of 1.08 μm and a field of view of about 210 μm are achieved when a 780 nm light passes through a 5 mm thick vacuum window. Moreover, such a design can be well adapted to a broad range of laser wavelengths (560-1000 nm) and vacuum window thicknesses (0-6 mm) by simply modifying one lens spacing, while maintaining a NA of above 0.43. The characteristics of the objective are evaluated experimentally, which are in good agreement with the simulations. Also, the objective has been successfully used for single-atom trapping and detecting in experiments. We believe that it will find more applications in various cold atom experiments.
In this work we describe the design and implementation of an optical system that enables the study of the interactions of Rydberg atoms or other Rydberg species in well-defined geometries. To understand and observe the dynamics of Rydberg interactions, the ability to engineer different arrangements of microscopic cold atom traps and manipulate their positions with a precision of a few microns is essential. This is accomplished by a custom designed high-numerical-aperture long-working-distance objective lens and a spatial light modulator device to control the phase of an incoming optical beam. Several different trap geometries have been realized, with a spatial resolution of a few microns, including a 1-dimensional chain, a 2-dimensional square grid, and a circular array of traps. The objective lens has been designed to provide diffraction limited performance at multiple wavelengths facilitating the creation of not only micron-scale atom traps but also the fluorescence imaging of trapped atoms. The system enables precise control over trap positions, and hence the locations at which atoms might be excited, with applications in, for example, the study of long-range interactions between Rydberg atoms, the creation of long-range Rydberg molecules, the implementation of qubits for quantum computing based on Rydberg atoms, and in quantum simulation.
We report on an ion-optical system that serves as a microscope for ultracold ground state and Rydberg atoms. The system is designed to achieve a magnification of up to 1000 and a spatial resolution in the 100 nm range, thereby surpassing many standard imaging techniques for cold atoms. The microscope consists of four electrostatic lenses and a microchannel plate in conjunction with a delay line detector in order to achieve single particle sensitivity with high temporal and spatial resolution. We describe the design process of the microscope including ion-optical simulations of the imaging system and characterize aberrations and the resolution limit. Furthermore, we present the experimental realization of the microscope in a cold atom setup and investigate its performance by patterned ionization with a structure size down to 2.7 μ m. The microscope meets the requirements for studying various many-body effects, ranging from correlations in cold quantum gases up to Rydberg molecule formation.