Optics Express

Quantum gas microscope assisted with T-shape vacuum viewports

Ye Tian, Zhongchi Zhang, Jilai Ye, Yajuan Zhao, Jiazhong Hu, Wenlan Chen

Published Sep 14, 2022• 0 citations
Publisher

Abstract

A quantum gas microscope plays an important role in cold-atom experiments, which provides a high-resolution imaging of the spatial distributions of cold atoms. Here we design, build and calibrate an integrated microscope for quantum gases with all the optical components fixed outside the vacuum chamber. It provides large numerical aperture (NA) of 0.75, as well as good optical access from side for atom loading in cold-atom experiments due to long working distance (7 mm fused silica+6 mm vacuum) of the microscope objective. We make a special design of the vacuum viewport with a T-shape window, to suppress the window flatness distortion introduced by the metal-glass binding process, and protect the high-resolution imaging from distortions due to unflattened window. The achieved Strehl ratio is 0.9204 using scanning-near-field microscopy (SNOM) fiber coupling incoherent light as point light source.

DOI
10.1364/oe.471041

Related papers

Design of compact high resolution imaging system for cold atom experiments

Xiaoyang Shen, Yi-Hao Cheng, Xia Lin

In cold atom experiments, high resolution imaging systems have been used to extract in-situ density information when studying quantum gases, which is one of the hot topics in this field. Such a system is usually called “quantum-gas microscope”. In order to achieve a long working distance and large magnification, high resolution imaging of cold atoms through a vacuum window usually requires a long distance between the atoms and the camera. However, due to space limitation caused by a large number of nearby optical elements, it may be difficult to realize a long imaging system, which is a common case in cold atom experiments. Herein we present an imaging system that can achieve a short distance between the atoms and the image plane with diffraction-limited 1 μm resolution and 50 magnification. The telephoto lens design is adopted to reduce the back focal length and enhance the pointing stability of the imaging lens. The system is optimized at an operating wavelength of 767 nm and corrects aberrations induced by a 5-mm-thick silica vacuum window. At a working distance of 32 mm, a diffraction-limited field of view of 408 μm is obtained. The simulation result shows that by changing the air space between lenses, our design operates across a wide range of window thicknesses (0–15 mm), which makes it robust enough to be used in typical laboratories. This compact imaging system is made from commercial on-shelf Φ2 in (1 in = 2.54 cm) singlets and consists of two components: a microscope objective with a numerical aperture of 0.47 and a telephoto objective with a long effective focal length of 1826 mm. Both are infinitely corrected, allowing the distance between them to be adjusted to insert optical elements for irradiating atoms with laser beams of different wavelengths without affecting the imaging resolution. Taking the manufacturing and assembling tolerances into consideration, the Monte Carlo analyses show that more than 95% of the random samples are diffraction-limited within the field of view. This high success rate ensures that these two objectives can be achieved easily in the experiment. Combined with its performance with other wavelengths (470–1064 nm), this imaging system can be used for imaging different atom species, such as sodium, lithium, and cesium.

Acta Physica Sinica•Dec 15, 2023•0 citations

A versatile high resolution objective for imaging quantum gases

L. M. Bennie, Philip T. Starkey, M. Jasperse +3 more

We present a high resolution objective lens made entirely from catalog singlets that has a numerical aperture of 0.36. It corrects for aberrations introduced by a glass window and has a long working distance of 35 mm, making it suitable for imaging objects within a vacuum system. This offers simple high resolution imaging for many in the quantum gas community. The objective achieves a resolution of 1.3 μm at the design wavelength of 780 nm, and a diffraction-limited field of view of 360 μm when imaging through a 5 mm thick window. Images of a resolution target and a pinhole show quantitative agreement with the simulated lens performance. The objective is suitable for diffraction-limited monochromatic imaging on the D2 line of all the alkalis by changing only the aperture diameter, retaining numerical apertures above 0.32. The design corrects for window thicknesses of up to 15 mm if the singlet spacings are modified.

arXiv:1302.4166•Optics Express•Apr 4, 2013•23 citations

Imaging Fermionic Atoms in a Quantum Gas Microscope

Graham J. A. Edge

This thesis describes the methods used to achieve single-atom and single-site resolved fluorescence imaging of a quantum gas of fermionic atoms held in an optical lattice. This kind of quantum gas microscopy has been previously applied to bosonic atoms in two experiments, and has allowed for extensive studies of many-body quantum systems. Here we detail methods to extend the techniques of quantum gas microscopy to fermionic species of atoms, opening the door to quantum simulation of electronic models of condensed matter physics. We prepare quantum degenerate gases of fermionic 40K through sympathetic cooling with a gas of \Rb. The gas prepared is trapped less than 1 mm away from a thin vacuum window, an experimental geometry which permits interrogation with a large Numerical Aperture microscope objective. The cloud is loaded into a 527 nm-period cubic optical lattice, ideal for quantum simulation of many-body models of fermionic particles such as the Hubbard model. The optical lattice is designed to allow for potential depths up to V/kB = 250 microKelvin, sufficient to strongly confine 40K atoms into individual lattice sites. EIT cooling --- a technique previously demonstrated in ion-trapping experiments --- is used to cool the fermionic atoms deeply towards the ground motional state of the lattice wells. We collect the photons scattered during continuous application of EIT cooling, while atoms are kept pinned in the lattice for many seconds. We strongly suppress all other sources of light with the use of a modulated cooling scheme and a spinning chopper wheel. Collecting the scattered light produced during 2 s of EIT cooling allows us to resolve single atoms in a fluorescence image. We demonstrate that the high resolution of our imaging apparatus also permits atom positions to be precisely identified on the length scale of the optical lattice. Thus we demonstrate the realisation of a quantum gas microscope for fermionic atoms, allowing for precise investigation of the ground states and dynamics of correlated quantum states of fermionic particles.

•Jun 1, 2017•0 citations

Quantum Gas Microscopy of Bosonic Correlations in the Continuum

Jinggang Xiang

This thesis details the complete upgrade and renovation of an existing experimental platform into a high-resolution quantum gas microscope for ultracold 87Rb atoms. Quantum gas microscopes enable site-resolved imaging, providing unprecedented access to quantum statistical effects and many-body phenomena. While such instruments are often employed to study physics in optical lattices, we have innovatively adapted our apparatus to investigate bulk system behavior. A major part of this project involved upgrading the scientific apparatus and retrofitting the previous system. We introduced new optical components, including a high-NA objective, and improved the vacuum system for better optical access. Extensive lab renovations, from upgrading the optical table to reorganizing the laser and imaging setups, were carried out to enhance mechanical and thermal stability. Rigorous optical benchmarking confirmed that the objective achieves diffractionlimited imaging, which is critical for resolving single atoms. This capability allowed us to detect density fluctuations at the scale of the thermal de Broglie wavelength in a quasi-two-dimensional gas of 87Rb atoms. In an experiment resembling Hanbury Brown and Twiss interferometry, we measured a 30% enhancement in the second-order correlation function in situ, demonstrating strong bosonic bunching. This outcome underscores the microscope’s precision and the importance of high-resolution imaging in capturing subtle quantum statistical effects. The successful realization of this apparatus demonstrates the utility of quantum gas microscopes in probing bulk systems. With this new platform in place, future studies can explore critical phenomena, many-body correlations, matter-wave emission, and quantum simulations with cold atoms.

•May 1, 2025•0 citations

Design and assembly of a cavity microscope with high numerical aperture for quantum simulations

Gaia Bolognini, Z. Xue, Michael Alexander Eichenberger +5 more

We present the design and assembly of a cavity microscope for quantum simulations with ultracold atoms. The system integrates a high-finesse optical cavity with a pair of high-numerical aperture lenses sharing a common optical axis, enabling simultaneous operation with light close-to-atomic resonance. The system keeps the advantages of a rigid, single-block structure holding the lenses and cavity together, and improves over existing designs by using most of the solid angle left free by the cavity mode for imaging and atomic manipulation purposes. The cavity has a length of 19.786 mm, a finesse of 2.35 × 10 4 and operates 214 µm away from the concentric limit, deep in the strong coupling regime. The two lenses offer a numerical aperture of 0.52 each and maximal optical access in all directions transverse to the cavity axis, compatible with applications in quantum-gas microscopes, micro-tweezer arrays or few-fermions systems, as well as future cavity-assisted quantum simulation protocols demanding sub-cavity-mode control of the atom-cavity coupling.

arXiv:2505.10733•Optics Express•Sep 1, 2025•2 citations

High-resolution imaging and manipulation of cold atoms through a multimode fiber

Sébastien Garcia, Nicolas Vitrant, Kilian Müller +1 more

A high imaging resolution or a tight focus of a laser beam imposes a certain minimal numerical aperture (NA) of the optical system. Macroscopic high NA lenses constraint strongly the spatial organization of experiments, in particular when imaging or trapping cold atoms inside a vacuum chamber. Multimode fibers, in conjunction with spatial light modulators, offer an interesting alternative to high NA lenses. Indeed, they are flexible optical waveguides with very small transverse dimensions (∼ 100 μm), and reasonably high NA (up to 0.5). For those reasons, the use of multimode fibers for imaging or laser manipulation purposes has been widely studied in the past years. Here, we transfer these techniques to the field of cold atoms with a multimode fiber forming a compact optical bridge between the inside and the outside of an ultra-high vacuum chamber. We manipulate atoms with laser beams produced through the fiber by digital optical phase conjugation with a spatial light modulator. We are able to transport a small cloud of cold rubidium atoms with a moving optical lattice at about 200 μm from the fiber tip. We can then load them in small optical tweezers with a waist of 1.2 μm. By characterizing the propagation of light modes inside the fiber, we numerically invert its transformation and we reconstruct absorption images of the trapped atoms with a resolution of approximately 1 μm. These results pave the way towards the efficient use of multimode fibers in spatially constrained quantum technology platforms relying on cold atoms.

SPIE Quantum Technologies•May 31, 2022•0 citations
A quantum gas microscope plays an important role in cold-atom experiments, which provides a high-resolution imaging of the spatial distributions of cold atoms. Here we design, build and calibrate an integrated microscope for quantum gases with all the optical components fixed outside the vacuum chamber. It provides large numerical aperture (NA) of 0.75, as well as good optical access from side for atom loading in cold-atom experiments due to long working distance (7 mm fused silica+6 mm vacuum) of the microscope objective. We make a special design of the vacuum viewport with a T-shape window, to suppress the window flatness distortion introduced by the metal-glass binding process, and protect the high-resolution imaging from distortions due to unflattened window. The achieved Strehl ratio is 0.9204 using scanning-near-field microscopy (SNOM) fiber coupling incoherent light as point light source.
In cold atom experiments, high resolution imaging systems have been used to extract in-situ density information when studying quantum gases, which is one of the hot topics in this field. Such a system is usually called “quantum-gas microscope”. In order to achieve a long working distance and large magnification, high resolution imaging of cold atoms through a vacuum window usually requires a long distance between the atoms and the camera. However, due to space limitation caused by a large number of nearby optical elements, it may be difficult to realize a long imaging system, which is a common case in cold atom experiments. Herein we present an imaging system that can achieve a short distance between the atoms and the image plane with diffraction-limited 1 μm resolution and 50 magnification. The telephoto lens design is adopted to reduce the back focal length and enhance the pointing stability of the imaging lens. The system is optimized at an operating wavelength of 767 nm and corrects aberrations induced by a 5-mm-thick silica vacuum window. At a working distance of 32 mm, a diffraction-limited field of view of 408 μm is obtained. The simulation result shows that by changing the air space between lenses, our design operates across a wide range of window thicknesses (0–15 mm), which makes it robust enough to be used in typical laboratories. This compact imaging system is made from commercial on-shelf Φ2 in (1 in = 2.54 cm) singlets and consists of two components: a microscope objective with a numerical aperture of 0.47 and a telephoto objective with a long effective focal length of 1826 mm. Both are infinitely corrected, allowing the distance between them to be adjusted to insert optical elements for irradiating atoms with laser beams of different wavelengths without affecting the imaging resolution. Taking the manufacturing and assembling tolerances into consideration, the Monte Carlo analyses show that more than 95% of the random samples are diffraction-limited within the field of view. This high success rate ensures that these two objectives can be achieved easily in the experiment. Combined with its performance with other wavelengths (470–1064 nm), this imaging system can be used for imaging different atom species, such as sodium, lithium, and cesium.
We present a high resolution objective lens made entirely from catalog singlets that has a numerical aperture of 0.36. It corrects for aberrations introduced by a glass window and has a long working distance of 35 mm, making it suitable for imaging objects within a vacuum system. This offers simple high resolution imaging for many in the quantum gas community. The objective achieves a resolution of 1.3 μm at the design wavelength of 780 nm, and a diffraction-limited field of view of 360 μm when imaging through a 5 mm thick window. Images of a resolution target and a pinhole show quantitative agreement with the simulated lens performance. The objective is suitable for diffraction-limited monochromatic imaging on the D2 line of all the alkalis by changing only the aperture diameter, retaining numerical apertures above 0.32. The design corrects for window thicknesses of up to 15 mm if the singlet spacings are modified.
This thesis describes the methods used to achieve single-atom and single-site resolved fluorescence imaging of a quantum gas of fermionic atoms held in an optical lattice. This kind of quantum gas microscopy has been previously applied to bosonic atoms in two experiments, and has allowed for extensive studies of many-body quantum systems. Here we detail methods to extend the techniques of quantum gas microscopy to fermionic species of atoms, opening the door to quantum simulation of electronic models of condensed matter physics. We prepare quantum degenerate gases of fermionic 40K through sympathetic cooling with a gas of \Rb. The gas prepared is trapped less than 1 mm away from a thin vacuum window, an experimental geometry which permits interrogation with a large Numerical Aperture microscope objective. The cloud is loaded into a 527 nm-period cubic optical lattice, ideal for quantum simulation of many-body models of fermionic particles such as the Hubbard model. The optical lattice is designed to allow for potential depths up to V/kB = 250 microKelvin, sufficient to strongly confine 40K atoms into individual lattice sites. EIT cooling --- a technique previously demonstrated in ion-trapping experiments --- is used to cool the fermionic atoms deeply towards the ground motional state of the lattice wells. We collect the photons scattered during continuous application of EIT cooling, while atoms are kept pinned in the lattice for many seconds. We strongly suppress all other sources of light with the use of a modulated cooling scheme and a spinning chopper wheel. Collecting the scattered light produced during 2 s of EIT cooling allows us to resolve single atoms in a fluorescence image. We demonstrate that the high resolution of our imaging apparatus also permits atom positions to be precisely identified on the length scale of the optical lattice. Thus we demonstrate the realisation of a quantum gas microscope for fermionic atoms, allowing for precise investigation of the ground states and dynamics of correlated quantum states of fermionic particles.
This thesis details the complete upgrade and renovation of an existing experimental platform into a high-resolution quantum gas microscope for ultracold 87Rb atoms. Quantum gas microscopes enable site-resolved imaging, providing unprecedented access to quantum statistical effects and many-body phenomena. While such instruments are often employed to study physics in optical lattices, we have innovatively adapted our apparatus to investigate bulk system behavior. A major part of this project involved upgrading the scientific apparatus and retrofitting the previous system. We introduced new optical components, including a high-NA objective, and improved the vacuum system for better optical access. Extensive lab renovations, from upgrading the optical table to reorganizing the laser and imaging setups, were carried out to enhance mechanical and thermal stability. Rigorous optical benchmarking confirmed that the objective achieves diffractionlimited imaging, which is critical for resolving single atoms. This capability allowed us to detect density fluctuations at the scale of the thermal de Broglie wavelength in a quasi-two-dimensional gas of 87Rb atoms. In an experiment resembling Hanbury Brown and Twiss interferometry, we measured a 30% enhancement in the second-order correlation function in situ, demonstrating strong bosonic bunching. This outcome underscores the microscope’s precision and the importance of high-resolution imaging in capturing subtle quantum statistical effects. The successful realization of this apparatus demonstrates the utility of quantum gas microscopes in probing bulk systems. With this new platform in place, future studies can explore critical phenomena, many-body correlations, matter-wave emission, and quantum simulations with cold atoms.
We present the design and assembly of a cavity microscope for quantum simulations with ultracold atoms. The system integrates a high-finesse optical cavity with a pair of high-numerical aperture lenses sharing a common optical axis, enabling simultaneous operation with light close-to-atomic resonance. The system keeps the advantages of a rigid, single-block structure holding the lenses and cavity together, and improves over existing designs by using most of the solid angle left free by the cavity mode for imaging and atomic manipulation purposes. The cavity has a length of 19.786 mm, a finesse of 2.35 × 10 4 and operates 214 µm away from the concentric limit, deep in the strong coupling regime. The two lenses offer a numerical aperture of 0.52 each and maximal optical access in all directions transverse to the cavity axis, compatible with applications in quantum-gas microscopes, micro-tweezer arrays or few-fermions systems, as well as future cavity-assisted quantum simulation protocols demanding sub-cavity-mode control of the atom-cavity coupling.
A high imaging resolution or a tight focus of a laser beam imposes a certain minimal numerical aperture (NA) of the optical system. Macroscopic high NA lenses constraint strongly the spatial organization of experiments, in particular when imaging or trapping cold atoms inside a vacuum chamber. Multimode fibers, in conjunction with spatial light modulators, offer an interesting alternative to high NA lenses. Indeed, they are flexible optical waveguides with very small transverse dimensions (∼ 100 μm), and reasonably high NA (up to 0.5). For those reasons, the use of multimode fibers for imaging or laser manipulation purposes has been widely studied in the past years. Here, we transfer these techniques to the field of cold atoms with a multimode fiber forming a compact optical bridge between the inside and the outside of an ultra-high vacuum chamber. We manipulate atoms with laser beams produced through the fiber by digital optical phase conjugation with a spatial light modulator. We are able to transport a small cloud of cold rubidium atoms with a moving optical lattice at about 200 μm from the fiber tip. We can then load them in small optical tweezers with a waist of 1.2 μm. By characterizing the propagation of light modes inside the fiber, we numerically invert its transformation and we reconstruct absorption images of the trapped atoms with a resolution of approximately 1 μm. These results pave the way towards the efficient use of multimode fibers in spatially constrained quantum technology platforms relying on cold atoms.