arXiv:2002.11906 · Review of Scientific Instruments

High-resolution imaging of Rydberg atoms in optical lattices using an aspheric-lens objective in vacuum

Chuyang Shen, Cheng Chen, Xiaoling Wu, Shen Dong, Yue Cui, Li You, Meng Khoon Tey

Published Jun 1, 2020• 4 citations
arXivHTMLPDF

Abstract

We present a high-resolution, simple, and versatile system for imaging ultracold Rydberg atoms in optical lattices. The imaging objective is a single aspheric lens [with a working distance of 20.6 mm and a numerical aperture (NA) of 0.51] placed inside the vacuum chamber. Adopting a large-working-distance lens leaves room for electrodes and electrostatic shields to control electric fields around Rydberg atoms. With this setup, we achieve a Rayleigh resolution of 1.10 μm or 1.41λ (λ = 780 nm), limited by the NA of the aspheric lens. For systems of highly excited Rydberg states with blockade radii greater than a few μm, the resolution achieved is sufficient for studying many physical processes of interest.

DOI
10.1063/5.0006026

Related papers

An adaptable two-lens high-resolution objective for single-site resolved imaging of atoms in optical lattices

Matthias W. Gempel, Torsten Hartmann, Torben Schulze +3 more

In this paper, we present a high-resolution, simple, and versatile imaging system for single-site resolved imaging of atoms in optical lattices. The system, which relies on an adaptable infinite conjugate two-lens design, has a numerical aperture of 0.52, which can in the ideal case be further extended to 0.57. It is optimized for imaging on the sodium D2-line but allows us to tune the objective’s diffraction limited performance between 400 nm and 1000 nm by changing the distance between the two lenses. Furthermore, the objective is designed to be integrated into a typical atomic physics vacuum apparatus where the operating distance can be large (>20 mm) and diffraction limited performance still needs to be achieved when imaging through thick vacuum windows (6 mm to 10 mm). Imaging gold nanoparticles, using a wavelength of 589 nm which corresponds to the D2-line of sodium atoms, we measure diffraction limited performance and a resolution corresponding to an Airy radius of less than 0.7 µm, enabling potential single-site resolution in the commonly used 532 nm optical lattice spacing.

Review of Scientific Instruments•May 1, 2019•8 citations

Microscopic trapping and high-resolution imaging of ultra cold Rydberg atoms

Harish Rathore

In this work we describe the design and implementation of an optical system that enables the study of the interactions of Rydberg atoms or other Rydberg species in well-defined geometries. To understand and observe the dynamics of Rydberg interactions, the ability to engineer different arrangements of microscopic cold atom traps and manipulate their positions with a precision of a few microns is essential. This is accomplished by a custom designed high-numerical-aperture long-working-distance objective lens and a spatial light modulator device to control the phase of an incoming optical beam. Several different trap geometries have been realized, with a spatial resolution of a few microns, including a 1-dimensional chain, a 2-dimensional square grid, and a circular array of traps. The objective lens has been designed to provide diffraction limited performance at multiple wavelengths facilitating the creation of not only micron-scale atom traps but also the fluorescence imaging of trapped atoms. The system enables precise control over trap positions, and hence the locations at which atoms might be excited, with applications in, for example, the study of long-range interactions between Rydberg atoms, the creation of long-range Rydberg molecules, the implementation of qubits for quantum computing based on Rydberg atoms, and in quantum simulation.

•Jul 22, 2020•0 citations

Design of compact high resolution imaging system for cold atom experiments

Xiaoyang Shen, Yi-Hao Cheng, Xia Lin

In cold atom experiments, high resolution imaging systems have been used to extract in-situ density information when studying quantum gases, which is one of the hot topics in this field. Such a system is usually called “quantum-gas microscope”. In order to achieve a long working distance and large magnification, high resolution imaging of cold atoms through a vacuum window usually requires a long distance between the atoms and the camera. However, due to space limitation caused by a large number of nearby optical elements, it may be difficult to realize a long imaging system, which is a common case in cold atom experiments. Herein we present an imaging system that can achieve a short distance between the atoms and the image plane with diffraction-limited 1 μm resolution and 50 magnification. The telephoto lens design is adopted to reduce the back focal length and enhance the pointing stability of the imaging lens. The system is optimized at an operating wavelength of 767 nm and corrects aberrations induced by a 5-mm-thick silica vacuum window. At a working distance of 32 mm, a diffraction-limited field of view of 408 μm is obtained. The simulation result shows that by changing the air space between lenses, our design operates across a wide range of window thicknesses (0–15 mm), which makes it robust enough to be used in typical laboratories. This compact imaging system is made from commercial on-shelf Φ2 in (1 in = 2.54 cm) singlets and consists of two components: a microscope objective with a numerical aperture of 0.47 and a telephoto objective with a long effective focal length of 1826 mm. Both are infinitely corrected, allowing the distance between them to be adjusted to insert optical elements for irradiating atoms with laser beams of different wavelengths without affecting the imaging resolution. Taking the manufacturing and assembling tolerances into consideration, the Monte Carlo analyses show that more than 95% of the random samples are diffraction-limited within the field of view. This high success rate ensures that these two objectives can be achieved easily in the experiment. Combined with its performance with other wavelengths (470–1064 nm), this imaging system can be used for imaging different atom species, such as sodium, lithium, and cesium.

Acta Physica Sinica•Dec 15, 2023•0 citations

Optical System for Implementing Accurate Two-Qubit Gates on Neutral Atoms

P. I. Betleni, Ilya I. Beterov

Abstract— Schemes for laser excitation of ultracold Rydberg rubidium atoms in optical dipole traps are considered for implementing two-qubit gates on neutral atoms. We discuss advantages and disadvantages of the schemes comprising objectives arranged outside a glass cell and utilizing aspheric lenses placed inside a vacuum chamber. A scheme is suggested of the objective with a numerical aperture of 0.39 and flange focal length of 19 mm, which can be placed in a vacuum chamber and combined with a system of electrodes for controlling an electric field in the domain of atom interaction with laser radiation.

Bulletin of the Lebedev Physics Institute•May 31, 2025•1 citation

A versatile high resolution objective for imaging quantum gases

L. M. Bennie, Philip T. Starkey, M. Jasperse +3 more

We present a high resolution objective lens made entirely from catalog singlets that has a numerical aperture of 0.36. It corrects for aberrations introduced by a glass window and has a long working distance of 35 mm, making it suitable for imaging objects within a vacuum system. This offers simple high resolution imaging for many in the quantum gas community. The objective achieves a resolution of 1.3 μm at the design wavelength of 780 nm, and a diffraction-limited field of view of 360 μm when imaging through a 5 mm thick window. Images of a resolution target and a pinhole show quantitative agreement with the simulated lens performance. The objective is suitable for diffraction-limited monochromatic imaging on the D2 line of all the alkalis by changing only the aperture diameter, retaining numerical apertures above 0.32. The design corrects for window thicknesses of up to 15 mm if the singlet spacings are modified.

arXiv:1302.4166•Optics Express•Apr 4, 2013•23 citations

A high resolution ion microscope for cold atoms

Markus Stecker, Hannah Schefzyk, József Fortágh +1 more

We report on an ion-optical system that serves as a microscope for ultracold ground state and Rydberg atoms. The system is designed to achieve a magnification of up to 1000 and a spatial resolution in the 100 nm range, thereby surpassing many standard imaging techniques for cold atoms. The microscope consists of four electrostatic lenses and a microchannel plate in conjunction with a delay line detector in order to achieve single particle sensitivity with high temporal and spatial resolution. We describe the design process of the microscope including ion-optical simulations of the imaging system and characterize aberrations and the resolution limit. Furthermore, we present the experimental realization of the microscope in a cold atom setup and investigate its performance by patterned ionization with a structure size down to 2.7 μ m. The microscope meets the requirements for studying various many-body effects, ranging from correlations in cold quantum gases up to Rydberg molecule formation.

arXiv:1701.02915•New Journal of Physics•Apr 13, 2017•28 citations
We present a high-resolution, simple, and versatile system for imaging ultracold Rydberg atoms in optical lattices. The imaging objective is a single aspheric lens [with a working distance of 20.6 mm and a numerical aperture (NA) of 0.51] placed inside the vacuum chamber. Adopting a large-working-distance lens leaves room for electrodes and electrostatic shields to control electric fields around Rydberg atoms. With this setup, we achieve a Rayleigh resolution of 1.10 μm or 1.41λ (λ = 780 nm), limited by the NA of the aspheric lens. For systems of highly excited Rydberg states with blockade radii greater than a few μm, the resolution achieved is sufficient for studying many physical processes of interest.
In this paper, we present a high-resolution, simple, and versatile imaging system for single-site resolved imaging of atoms in optical lattices. The system, which relies on an adaptable infinite conjugate two-lens design, has a numerical aperture of 0.52, which can in the ideal case be further extended to 0.57. It is optimized for imaging on the sodium D2-line but allows us to tune the objective’s diffraction limited performance between 400 nm and 1000 nm by changing the distance between the two lenses. Furthermore, the objective is designed to be integrated into a typical atomic physics vacuum apparatus where the operating distance can be large (>20 mm) and diffraction limited performance still needs to be achieved when imaging through thick vacuum windows (6 mm to 10 mm). Imaging gold nanoparticles, using a wavelength of 589 nm which corresponds to the D2-line of sodium atoms, we measure diffraction limited performance and a resolution corresponding to an Airy radius of less than 0.7 µm, enabling potential single-site resolution in the commonly used 532 nm optical lattice spacing.
In this work we describe the design and implementation of an optical system that enables the study of the interactions of Rydberg atoms or other Rydberg species in well-defined geometries. To understand and observe the dynamics of Rydberg interactions, the ability to engineer different arrangements of microscopic cold atom traps and manipulate their positions with a precision of a few microns is essential. This is accomplished by a custom designed high-numerical-aperture long-working-distance objective lens and a spatial light modulator device to control the phase of an incoming optical beam. Several different trap geometries have been realized, with a spatial resolution of a few microns, including a 1-dimensional chain, a 2-dimensional square grid, and a circular array of traps. The objective lens has been designed to provide diffraction limited performance at multiple wavelengths facilitating the creation of not only micron-scale atom traps but also the fluorescence imaging of trapped atoms. The system enables precise control over trap positions, and hence the locations at which atoms might be excited, with applications in, for example, the study of long-range interactions between Rydberg atoms, the creation of long-range Rydberg molecules, the implementation of qubits for quantum computing based on Rydberg atoms, and in quantum simulation.
In cold atom experiments, high resolution imaging systems have been used to extract in-situ density information when studying quantum gases, which is one of the hot topics in this field. Such a system is usually called “quantum-gas microscope”. In order to achieve a long working distance and large magnification, high resolution imaging of cold atoms through a vacuum window usually requires a long distance between the atoms and the camera. However, due to space limitation caused by a large number of nearby optical elements, it may be difficult to realize a long imaging system, which is a common case in cold atom experiments. Herein we present an imaging system that can achieve a short distance between the atoms and the image plane with diffraction-limited 1 μm resolution and 50 magnification. The telephoto lens design is adopted to reduce the back focal length and enhance the pointing stability of the imaging lens. The system is optimized at an operating wavelength of 767 nm and corrects aberrations induced by a 5-mm-thick silica vacuum window. At a working distance of 32 mm, a diffraction-limited field of view of 408 μm is obtained. The simulation result shows that by changing the air space between lenses, our design operates across a wide range of window thicknesses (0–15 mm), which makes it robust enough to be used in typical laboratories. This compact imaging system is made from commercial on-shelf Φ2 in (1 in = 2.54 cm) singlets and consists of two components: a microscope objective with a numerical aperture of 0.47 and a telephoto objective with a long effective focal length of 1826 mm. Both are infinitely corrected, allowing the distance between them to be adjusted to insert optical elements for irradiating atoms with laser beams of different wavelengths without affecting the imaging resolution. Taking the manufacturing and assembling tolerances into consideration, the Monte Carlo analyses show that more than 95% of the random samples are diffraction-limited within the field of view. This high success rate ensures that these two objectives can be achieved easily in the experiment. Combined with its performance with other wavelengths (470–1064 nm), this imaging system can be used for imaging different atom species, such as sodium, lithium, and cesium.
Abstract— Schemes for laser excitation of ultracold Rydberg rubidium atoms in optical dipole traps are considered for implementing two-qubit gates on neutral atoms. We discuss advantages and disadvantages of the schemes comprising objectives arranged outside a glass cell and utilizing aspheric lenses placed inside a vacuum chamber. A scheme is suggested of the objective with a numerical aperture of 0.39 and flange focal length of 19 mm, which can be placed in a vacuum chamber and combined with a system of electrodes for controlling an electric field in the domain of atom interaction with laser radiation.
We present a high resolution objective lens made entirely from catalog singlets that has a numerical aperture of 0.36. It corrects for aberrations introduced by a glass window and has a long working distance of 35 mm, making it suitable for imaging objects within a vacuum system. This offers simple high resolution imaging for many in the quantum gas community. The objective achieves a resolution of 1.3 μm at the design wavelength of 780 nm, and a diffraction-limited field of view of 360 μm when imaging through a 5 mm thick window. Images of a resolution target and a pinhole show quantitative agreement with the simulated lens performance. The objective is suitable for diffraction-limited monochromatic imaging on the D2 line of all the alkalis by changing only the aperture diameter, retaining numerical apertures above 0.32. The design corrects for window thicknesses of up to 15 mm if the singlet spacings are modified.
We report on an ion-optical system that serves as a microscope for ultracold ground state and Rydberg atoms. The system is designed to achieve a magnification of up to 1000 and a spatial resolution in the 100 nm range, thereby surpassing many standard imaging techniques for cold atoms. The microscope consists of four electrostatic lenses and a microchannel plate in conjunction with a delay line detector in order to achieve single particle sensitivity with high temporal and spatial resolution. We describe the design process of the microscope including ion-optical simulations of the imaging system and characterize aberrations and the resolution limit. Furthermore, we present the experimental realization of the microscope in a cold atom setup and investigate its performance by patterned ionization with a structure size down to 2.7 μ m. The microscope meets the requirements for studying various many-body effects, ranging from correlations in cold quantum gases up to Rydberg molecule formation.