Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Applied Physics Letters

Multiparametric sensing with the nitrogen-vacancy color center in diamond

Leon Advena, Tofianme Sorgwe, Florian Sledz, Mario Agio, Assegid M. Flatae

Published Jan 19, 2026• 2 citations
Publisher

Abstract

Modern sensing applications increasingly require the simultaneous measurement of multiple physical parameters with high sensitivity. However, traditional sensors often suffer from cross-sensitivity to different variables, making it difficult to separate overlapping effects, such as those caused by temperature and magnetic fields, in complex environments. This challenge highlights the need for robust multiparametric sensors capable of independently and accurately monitoring diverse conditions in real time. In this context, nitrogen-vacancy (NV) centers in diamond present a promising solution. These atomic-scale defects can be optically initialized, manipulated, and read out via laser excitation using optically detected magnetic resonance (ODMR), and they can operate under ambient and harsh conditions. In this work, we demonstrate a simultaneous and internally cross-validated sensing platform capable of detecting both magnetic fields and temperature with a sensitivity of around 500 nT/Hz and 10 mK/Hz, respectively. Our method integrates ODMR, zero-phonon line spectral shifts, and linewidth broadening, each providing independent spectral signatures sensitive to distinct physical effects. This approach enhances measurement precision, enables internal consistency checks, and decouples intertwined phenomena such as temperature-induced variations in magnetization. The demonstrated technique significantly expands the functional capabilities of NV-based sensors, advancing their potential for high-precision metrology in complex environments.

DOI
10.1063/5.0300868

Related papers

Novel Magnetic-Sensing Modalities with Nitrogen-Vacancy Centers in Diamond

Huijie Zheng, Arne Wickenbrock, Georgios Chatzidrosos +16 more

In modern-day quantum metrology, quantum sensors are widely employed to detect weak magnetic fields or nanoscale signals. Quantum devices, exploiting quantum coherence, are inevitably connected to physical constants and can achieve accuracy, repeatability, and precision approaching fundamental limits. As a result, these sensors have shown utility in a wide range of research domains spanning both science and technology. A rapidly emerging quantum sensing platform employs atomic-scale defects in crystals. In particular, magnetometry using nitrogen-vacancy (NV) color centers in diamond has garnered increasing interest. NV systems possess a combination of remarkable properties, optical addressability, long coherence times, and biocompatibility. Sensors based on NV centers excel in spatial resolution and magnetic sensitivity. These diamond-based sensors promise comparable combination of high spatial resolution and magnetic sensitivity without cryogenic operation. The above properties of NV magnetometers promise increasingly integrated quantum measurement technology, as a result, they have been extensively developed with various protocols and find use in numerous applications spanning materials characterization, nuclear magnetic resonance (NMR), condensed matter physics, paleomagnetism, neuroscience and living systems biology, and industrial vector magnetometry. In this chapter, NV centers are explored for magnetic sensing in a number of contexts. In general, we introduce novel regimes for magnetic-field probes with NV ensembles. Specifically, NV centers are developed for sensitive magnetometers for applications where microwaves (MWs) are prohibitively invasive and operations need to be carried out under zero ambient magnetic field. The primary goal of our discussion is to improve the utility of these NV center-based magnetometers.

IntechOpen eBooks•Feb 8, 2021•1 citation

Nitrogen vacancies (NV) centers in diamond for magnetic sensors and quantum sensing

Mayeul Chipaux, Stéphane Xavier, Alexandre Tallaire +6 more

Nitrogen Vacancy (NV) centers are point defects in diamond that allow magnetic field sensing based on Optically Detected Magnetic Resonance (ODMR). They are processed in ultrapure single-domain CVD grown diamond crystals and can be operated at room temperature. This results in solid-state sensors with a wide variety of applications. Ensemble of NV centers can be used to perform wide-field magnetic imaging with sensitivity in the nT range. Single NV centers can also be processed, which allows sensing at the atomic scale. This possibility, combined with its unique coherence properties, make NV center an ideal candidate for quantum sensing.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Feb 8, 2015•3 citations

Precision temperature sensing in the presence of magnetic field noise and vice-versa using nitrogen-vacancy centers in diamond

Adam M. Wojciechowski, Mürsel Karadas, Christian Osterkamp +5 more

We demonstrate a technique for precision sensing of the temperature or the magnetic field by simultaneously driving two hyperfine transitions involving distinct electronic states of the nitrogen-vacancy center in diamond. Frequency modulation of both driving fields is used with either the same or opposite phase, resulting in the immunity to fluctuations in either the magnetic field or the temperature, respectively. In this way, a sensitivity of 1.4 nT Hz−1∕2 or 430 μK Hz−1∕2 is demonstrated. The presented technique only requires a single frequency demodulator and enables the use of phase-sensitive camera imaging sensors. A simple extension of the method utilizing two demodulators allows for simultaneous, independent, and high-bandwidth monitoring of both the magnetic field and the temperature.

arXiv:1802.07224•Applied Physics Letters•Jul 2, 2018•59 citations

Development of a multi-channel highly-sensitive diamond quantum sensor

Atsumi Yoshimura, Ayumi Kanamoto, Naota Sekiguchi +9 more

Diamond quantum sensors utilizing nitrogen-vacancy (NV) centers in diamond can measure a tiny magnetic-field variation at room temperature with a high linearity and high spatial resolution. Because of these advantages, they have been actively studied for application to measure a biomagnetic field. In biomagnetic sensing applications, it is effective to measure at multiple points simultaneously with high sensitivity. In this study, we developed a highly sensitive diamond quantum sensor that can simultaneously measure the magnetic field at two points at the millimeter interval. We used two diamonds that were split from one HPHT-grown diamond and placed them at the 3-mm interval. A laser-induced fluorescence from the two diamonds were detected by a single photodiode. We applied different bias magnetic fields to each diamond, and thus the magnetic resonances at these diamonds had different resonance frequencies. By applying microwave fields whose frequencies were modulated at different modulation frequencies, the magnetic fields at the two diamonds can be obtained independently after demodulation. The noise spectral densities in the magnetic field measurement at the two diamonds’ locations. Since the measurement was performed outside a magnetic shield, a severe low-frequency environmental noise from railways and power line (50 Hz) noise peaks were observed. We evaluated the field sensitivities at the two diamonds to be 22 pT/√Hz in 25-300 Hz range with neglecting the power-line noise peaks and the environment noise peaks. The capability of simultaneously measuring a magnetic field at two points with the such high sensitivities will facilitate the biomagnetic sensing applications.

•Mar 19, 2025•0 citations

Nitrogen Vacancy Centers in Diamond for Quantum Biosensing: Magnetometry Techniques, Platforms and Applications

Sirsendu Ghosal, Umakant Prajapati, Sachin Negi +3 more

Quantum sensing using nitrogen-vacancy (NV) centers in diamond has emerged as a powerful platform for detecting ultra-low magnetic fields under ambient conditions. Owing to their long spin coherence times, optical addressability, and compatibility with aqueous environments, it has found widespread applications in biosensing and bio-imaging. This review presents the fundamental principles and recent advances in NV-based quantum magnetometry for biosensing applications, with a particular focus on measurements in aqueous medium and at cellular and molecular length scales. We discuss the underlying spin physics of NV centers and highlight two primary detection modalities: optically detected magnetic resonance (ODMR) and T1 relaxometry-based sensing and how these approaches aids in the detection of both static magnetic fields and dynamic magnetic noise arising from biological processes. The review explores key application areas, including nanoscale nuclear magnetic resonance (NMR), monitoring of neural activity, detection of abnormal or rogue cells using NV-based platforms etc. In addition, strategies for enhancing sensitivity, such as surface functionalization of nanodiamonds, femtosecond (fs) laser-written photonic structures, and integration with microfluidic and lab-on-chip systems have also been discussed in depth. We also address the critical challenges, including surface-induced decoherence, charge-state instability, and signal-to-noise limitations in biofluids associated with NV-based biosensing applications. Finally, we outline future prospects, highlighting how NV-based magnetic biosensing provides a promising pathway for translating quantum sensing technologies into practical biomedical applications.

quant-pharXiv:2609.04733•Sep 7, 2026

Optically Detected Spin Mixing of Nitrogen-Vacancy Centers in Diamond

Haonan Chang, Zhen-Nan 震南 Wang 王, Feilong Song +2 more

Abstract Transverse-magnetic-field-induced spin mixing in nitrogen-vacancy (NV) centers hybridizes the |0⟩ and | ± 1⟩ manifolds, degrading optical spin polarization and spin-dependent fluorescence and thereby limiting optically detected magnetic resonance (ODMR) contrast and quantum-sensor fidelity. While recent work has clarified key elements of NV photophysics, how spin mixing evolves with temperature under device-relevant operating conditions─and how it intertwines with charge-state dynamics─remains insufficiently quantified. Here we perform systematic magnetic-field-temperature (B-T) mapping of transverse-field-induced photoluminescence (PL) quenching in an ensemble of NV centers. By spectrally resolving the NV– and NV0 zero-phonon-line emission, we disentangle spin-mixing-driven contrast loss within NV– from correlated changes in charge-state-resolved fluorescence. We introduce an operational critical field Bc extracted from the PL-contrast line shape, which provides a compact, reproducible figure-of-merit for transverse-field robustness and enables straightforward comparison across temperatures and field geometries. The measured temperature dependence of Bc is captured by a concise model incorporating phonon-mediated excited-state orbital dynamics, establishing a predictive framework for optimizing operating conditions and benchmarking ensemble NV sensing platforms.

ACS Photonics•Jul 24, 2026•0 citations
Modern sensing applications increasingly require the simultaneous measurement of multiple physical parameters with high sensitivity. However, traditional sensors often suffer from cross-sensitivity to different variables, making it difficult to separate overlapping effects, such as those caused by temperature and magnetic fields, in complex environments. This challenge highlights the need for robust multiparametric sensors capable of independently and accurately monitoring diverse conditions in real time. In this context, nitrogen-vacancy (NV) centers in diamond present a promising solution. These atomic-scale defects can be optically initialized, manipulated, and read out via laser excitation using optically detected magnetic resonance (ODMR), and they can operate under ambient and harsh conditions. In this work, we demonstrate a simultaneous and internally cross-validated sensing platform capable of detecting both magnetic fields and temperature with a sensitivity of around 500 nT/Hz and 10 mK/Hz, respectively. Our method integrates ODMR, zero-phonon line spectral shifts, and linewidth broadening, each providing independent spectral signatures sensitive to distinct physical effects. This approach enhances measurement precision, enables internal consistency checks, and decouples intertwined phenomena such as temperature-induced variations in magnetization. The demonstrated technique significantly expands the functional capabilities of NV-based sensors, advancing their potential for high-precision metrology in complex environments.
In modern-day quantum metrology, quantum sensors are widely employed to detect weak magnetic fields or nanoscale signals. Quantum devices, exploiting quantum coherence, are inevitably connected to physical constants and can achieve accuracy, repeatability, and precision approaching fundamental limits. As a result, these sensors have shown utility in a wide range of research domains spanning both science and technology. A rapidly emerging quantum sensing platform employs atomic-scale defects in crystals. In particular, magnetometry using nitrogen-vacancy (NV) color centers in diamond has garnered increasing interest. NV systems possess a combination of remarkable properties, optical addressability, long coherence times, and biocompatibility. Sensors based on NV centers excel in spatial resolution and magnetic sensitivity. These diamond-based sensors promise comparable combination of high spatial resolution and magnetic sensitivity without cryogenic operation. The above properties of NV magnetometers promise increasingly integrated quantum measurement technology, as a result, they have been extensively developed with various protocols and find use in numerous applications spanning materials characterization, nuclear magnetic resonance (NMR), condensed matter physics, paleomagnetism, neuroscience and living systems biology, and industrial vector magnetometry. In this chapter, NV centers are explored for magnetic sensing in a number of contexts. In general, we introduce novel regimes for magnetic-field probes with NV ensembles. Specifically, NV centers are developed for sensitive magnetometers for applications where microwaves (MWs) are prohibitively invasive and operations need to be carried out under zero ambient magnetic field. The primary goal of our discussion is to improve the utility of these NV center-based magnetometers.
Nitrogen Vacancy (NV) centers are point defects in diamond that allow magnetic field sensing based on Optically Detected Magnetic Resonance (ODMR). They are processed in ultrapure single-domain CVD grown diamond crystals and can be operated at room temperature. This results in solid-state sensors with a wide variety of applications. Ensemble of NV centers can be used to perform wide-field magnetic imaging with sensitivity in the nT range. Single NV centers can also be processed, which allows sensing at the atomic scale. This possibility, combined with its unique coherence properties, make NV center an ideal candidate for quantum sensing.
We demonstrate a technique for precision sensing of the temperature or the magnetic field by simultaneously driving two hyperfine transitions involving distinct electronic states of the nitrogen-vacancy center in diamond. Frequency modulation of both driving fields is used with either the same or opposite phase, resulting in the immunity to fluctuations in either the magnetic field or the temperature, respectively. In this way, a sensitivity of 1.4 nT Hz−1∕2 or 430 μK Hz−1∕2 is demonstrated. The presented technique only requires a single frequency demodulator and enables the use of phase-sensitive camera imaging sensors. A simple extension of the method utilizing two demodulators allows for simultaneous, independent, and high-bandwidth monitoring of both the magnetic field and the temperature.
Diamond quantum sensors utilizing nitrogen-vacancy (NV) centers in diamond can measure a tiny magnetic-field variation at room temperature with a high linearity and high spatial resolution. Because of these advantages, they have been actively studied for application to measure a biomagnetic field. In biomagnetic sensing applications, it is effective to measure at multiple points simultaneously with high sensitivity. In this study, we developed a highly sensitive diamond quantum sensor that can simultaneously measure the magnetic field at two points at the millimeter interval. We used two diamonds that were split from one HPHT-grown diamond and placed them at the 3-mm interval. A laser-induced fluorescence from the two diamonds were detected by a single photodiode. We applied different bias magnetic fields to each diamond, and thus the magnetic resonances at these diamonds had different resonance frequencies. By applying microwave fields whose frequencies were modulated at different modulation frequencies, the magnetic fields at the two diamonds can be obtained independently after demodulation. The noise spectral densities in the magnetic field measurement at the two diamonds’ locations. Since the measurement was performed outside a magnetic shield, a severe low-frequency environmental noise from railways and power line (50 Hz) noise peaks were observed. We evaluated the field sensitivities at the two diamonds to be 22 pT/√Hz in 25-300 Hz range with neglecting the power-line noise peaks and the environment noise peaks. The capability of simultaneously measuring a magnetic field at two points with the such high sensitivities will facilitate the biomagnetic sensing applications.
Quantum sensing using nitrogen-vacancy (NV) centers in diamond has emerged as a powerful platform for detecting ultra-low magnetic fields under ambient conditions. Owing to their long spin coherence times, optical addressability, and compatibility with aqueous environments, it has found widespread applications in biosensing and bio-imaging. This review presents the fundamental principles and recent advances in NV-based quantum magnetometry for biosensing applications, with a particular focus on measurements in aqueous medium and at cellular and molecular length scales. We discuss the underlying spin physics of NV centers and highlight two primary detection modalities: optically detected magnetic resonance (ODMR) and T1 relaxometry-based sensing and how these approaches aids in the detection of both static magnetic fields and dynamic magnetic noise arising from biological processes. The review explores key application areas, including nanoscale nuclear magnetic resonance (NMR), monitoring of neural activity, detection of abnormal or rogue cells using NV-based platforms etc. In addition, strategies for enhancing sensitivity, such as surface functionalization of nanodiamonds, femtosecond (fs) laser-written photonic structures, and integration with microfluidic and lab-on-chip systems have also been discussed in depth. We also address the critical challenges, including surface-induced decoherence, charge-state instability, and signal-to-noise limitations in biofluids associated with NV-based biosensing applications. Finally, we outline future prospects, highlighting how NV-based magnetic biosensing provides a promising pathway for translating quantum sensing technologies into practical biomedical applications.
Abstract Transverse-magnetic-field-induced spin mixing in nitrogen-vacancy (NV) centers hybridizes the |0⟩ and | ± 1⟩ manifolds, degrading optical spin polarization and spin-dependent fluorescence and thereby limiting optically detected magnetic resonance (ODMR) contrast and quantum-sensor fidelity. While recent work has clarified key elements of NV photophysics, how spin mixing evolves with temperature under device-relevant operating conditions─and how it intertwines with charge-state dynamics─remains insufficiently quantified. Here we perform systematic magnetic-field-temperature (B-T) mapping of transverse-field-induced photoluminescence (PL) quenching in an ensemble of NV centers. By spectrally resolving the NV– and NV0 zero-phonon-line emission, we disentangle spin-mixing-driven contrast loss within NV– from correlated changes in charge-state-resolved fluorescence. We introduce an operational critical field Bc extracted from the PL-contrast line shape, which provides a compact, reproducible figure-of-merit for transverse-field robustness and enables straightforward comparison across temperatures and field geometries. The measured temperature dependence of Bc is captured by a concise model incorporating phonon-mediated excited-state orbital dynamics, establishing a predictive framework for optimizing operating conditions and benchmarking ensemble NV sensing platforms.