A Submillimeter Wave SIS Heterodyne Receiver Using Nb Tunnel Junctions with Integrated Tuning Circuits for 626 GHz

Morvan C. Salez, William R. McGrath, Pascal Febvre, B. Bumble, Henry George LeDuc

Published Aug 11, 1993• 0 citations
OpenAlex

Abstract

So far, the most sensitive heterodyne receivers in the millimeter-wave and submillimeter-wave frequency ranges have used the mixing response of the quasiparticle currents in SIS tunnel junctions.

Related papers

A Submillimeter Wave SIS Receiver for 547 GHz

William R. McGrath, Pascal Febvre, Hamid Javadi +3 more

The most sensitive heterodyne receivers used for millimeter wave and submillimeter wave radioastronomy employ superconductor-insulator-superconductor tunnel junctions as the nonlinear mixing element.

•Mar 30, 1993•4 citations

Quasi-optical submillimeter-wave SIS mixers with NbN/A1N/NbN tunnel junctions

Yoshinori Uzawa, Zhen Wang, Akira Kawakami

We report on low-noise heterodyne mixing with NbN/A1N/NbN tunnel junctions in the submillimeter-wave region for the first time. The receiver consists of the quasi-optical NbN SIS mixer with an integrated tuning circuit in which a radial short stub tuner is incorporated to resonate out the junction capacitance for RF matching and a balanced IF circuit for broadband IF matching. The prepared NbN SIS junction has a current density of 20 kA/cm 2 and is about 1 I1111 in diameter, supplying a small coC JRN product (o)CJRN = 3 at 300 GHz). The junctions showed good dc I-V characteristics, excellent submillimeter-wave responses and sensitive heterodyne mixing responses. From 254 to 350 GHz the average receiver noise temperature measured using by the standard Y-factor method was about 250 K (DSB) at 5 K. The lowest receiver noise temperature, 200 K (DSB), was obtained at around 303 GHz. Comparing NbN/A1N/NbN and Nb/A10x/Nb tunnel junction performance with the same tuning circuit showed that the frequency dependence of the receiver noise temperature agreed well in the two receivers. These results suggest that our well-controlled NbN SIS junctions can be used for terahertz mixer elements instead of Nb SIS junctions.

•Mar 1, 1996•2 citations

SIS receivers for millimeter and submillimeter-wave detection

Domenico Andreone, L. Brunetti, V. Lacquaniti +2 more

In this work we report the current status in our development of sensitive heterodyne detectors for efficient down-conversion of submillimeter-wave signals to D-band. These detectors use the strong non-linearity of Nb/Al-AlO/sub x//Nb tunnel junctions and employ preferably quasi-optical techniques to couple local-oscillator and radio-frequency signals to the superconducting junctions via a log-periodic antenna and hyper-hemispherical lens combination. Several devices have been fabricated and tested.

IEEE Transactions on Applied Superconductivity•Mar 1, 2001•3 citations

0.5-THz waveguide SIS mixers with NbN/AlN/NbN technology - art. no. 684013

Jing Li, Takeda Masanon, Zhen Wang

Heterodyne mixers based on superconducting SIS (superconductor-insulator-superconductor) tunnel junctions have been demonstrated to be the most sensitive coherent detectors at millimeter and submillimeter wavelengths. In fact, conventional superconducting SIS mixers with Nb/AIO(x)/Nb junction and Nb/SiO2/Nb tuning circuit have shown good performances with the noise temperature reaching as low as three times the quantum limit below 0.7THz, which is the gap frequency of Nb-based SIS junctions. However, due to the large loss in Nb thin-film superconducting microstrip lines, the noise performance of Nb SIS mixers deteriorates significantly above 0.7THz. With a gap frequency double that of Nb-based SIS junctions, NbN-based SIS junctions are of particular interest for the development of heterodyne mixers in the terahertz region.

•Jan 1, 2008•0 citations

Performance of an SIS receiver over 460 GHz to 640 GHz using submicron Nb junctions with integrated RF tuning circuits

Pascal Febvre

The most sensitive heterodyne receivers used formillimeter wave and submillimeter wave radioastronomyemploy superconductor-insulator-superconductor (SIS)tunnel junctions as the nonlinear mixing element. Goodperformance has recently been reported for SIS junctionsused in planar mixer circuits and waveguide mixers fromabout 300 GHz to 500 GHz. We have developed asubmillimeter wave SIS heterodyne receiver for observingimportant rotational transitions of molecules in theinterstellar medium near 550 GHz and 630 GHz. Thisreceiver is based on a waveguide mixer with an adjustablebackshort and E-plane tuner [1]. The mixer uses a highcurrent density, 0.25 gm2 Nb-A1Ox-Nb tunnel junctiondefined by electron beam lithography [2]. The capacitanceof the junction is compensated with an integrated RFsuperconductive microstrip tuning circuit. The receiverperformance has been measured over the frequency range460 GHz to 640 GHz. DSB receiver noise temperatures aslow as 200 ± 17 K at 540 GHz and 362 ± 33 K at626 GHz have been obtained. In addition, negativedifferential resistance has been observed in the DC I-Vcurve at frequencies around 491 GHz. These results indicatethat the superconductive Nb microstrip transmission linesused in the tuning circuits are low-loss and perform well upto at least 90% of the superconductor energy gap frequency.

International Conference on Infrared, Millimeter, and Terahertz Waves (IRMMW-THz)•Aug 30, 1993•0 citations

Superconducting detectors for infrared and millimeter waves

Paul L. Richards

Quasiparticle and Josephson tunneling currents in superconducting tunnel junctions provide nonlinear low-noise response up to terahertz frequencies. Many types of direct detector heterodyne mixer and parametric amplifier based on these effects have been explored. Only the SIS quasiparticle mixer has been sufficiently competitive to find significant applications. These mixers can have noise approaching the quantum limit TN = ℏω/k and gain larger than 10 dB. They are used at a number of observatories for molecular line radio astronomy at millimeter wavelengths. Similar applications at submillimeter wavelengths are beginning.

Conference on Lasers and Electro-Optics•Apr 25, 1988•0 citations
We report on low-noise heterodyne mixing with NbN/A1N/NbN tunnel junctions in the submillimeter-wave region for the first time. The receiver consists of the quasi-optical NbN SIS mixer with an integrated tuning circuit in which a radial short stub tuner is incorporated to resonate out the junction capacitance for RF matching and a balanced IF circuit for broadband IF matching. The prepared NbN SIS junction has a current density of 20 kA/cm 2 and is about 1 I1111 in diameter, supplying a small coC JRN product (o)CJRN = 3 at 300 GHz). The junctions showed good dc I-V characteristics, excellent submillimeter-wave responses and sensitive heterodyne mixing responses. From 254 to 350 GHz the average receiver noise temperature measured using by the standard Y-factor method was about 250 K (DSB) at 5 K. The lowest receiver noise temperature, 200 K (DSB), was obtained at around 303 GHz. Comparing NbN/A1N/NbN and Nb/A10x/Nb tunnel junction performance with the same tuning circuit showed that the frequency dependence of the receiver noise temperature agreed well in the two receivers. These results suggest that our well-controlled NbN SIS junctions can be used for terahertz mixer elements instead of Nb SIS junctions.
In this work we report the current status in our development of sensitive heterodyne detectors for efficient down-conversion of submillimeter-wave signals to D-band. These detectors use the strong non-linearity of Nb/Al-AlO/sub x//Nb tunnel junctions and employ preferably quasi-optical techniques to couple local-oscillator and radio-frequency signals to the superconducting junctions via a log-periodic antenna and hyper-hemispherical lens combination. Several devices have been fabricated and tested.
Heterodyne mixers based on superconducting SIS (superconductor-insulator-superconductor) tunnel junctions have been demonstrated to be the most sensitive coherent detectors at millimeter and submillimeter wavelengths. In fact, conventional superconducting SIS mixers with Nb/AIO(x)/Nb junction and Nb/SiO2/Nb tuning circuit have shown good performances with the noise temperature reaching as low as three times the quantum limit below 0.7THz, which is the gap frequency of Nb-based SIS junctions. However, due to the large loss in Nb thin-film superconducting microstrip lines, the noise performance of Nb SIS mixers deteriorates significantly above 0.7THz. With a gap frequency double that of Nb-based SIS junctions, NbN-based SIS junctions are of particular interest for the development of heterodyne mixers in the terahertz region.
The most sensitive heterodyne receivers used formillimeter wave and submillimeter wave radioastronomyemploy superconductor-insulator-superconductor (SIS)tunnel junctions as the nonlinear mixing element. Goodperformance has recently been reported for SIS junctionsused in planar mixer circuits and waveguide mixers fromabout 300 GHz to 500 GHz. We have developed asubmillimeter wave SIS heterodyne receiver for observingimportant rotational transitions of molecules in theinterstellar medium near 550 GHz and 630 GHz. Thisreceiver is based on a waveguide mixer with an adjustablebackshort and E-plane tuner [1]. The mixer uses a highcurrent density, 0.25 gm2 Nb-A1Ox-Nb tunnel junctiondefined by electron beam lithography [2]. The capacitanceof the junction is compensated with an integrated RFsuperconductive microstrip tuning circuit. The receiverperformance has been measured over the frequency range460 GHz to 640 GHz. DSB receiver noise temperatures aslow as 200 ± 17 K at 540 GHz and 362 ± 33 K at626 GHz have been obtained. In addition, negativedifferential resistance has been observed in the DC I-Vcurve at frequencies around 491 GHz. These results indicatethat the superconductive Nb microstrip transmission linesused in the tuning circuits are low-loss and perform well upto at least 90% of the superconductor energy gap frequency.
Quasiparticle and Josephson tunneling currents in superconducting tunnel junctions provide nonlinear low-noise response up to terahertz frequencies. Many types of direct detector heterodyne mixer and parametric amplifier based on these effects have been explored. Only the SIS quasiparticle mixer has been sufficiently competitive to find significant applications. These mixers can have noise approaching the quantum limit TN = ℏω/k and gain larger than 10 dB. They are used at a number of observatories for molecular line radio astronomy at millimeter wavelengths. Similar applications at submillimeter wavelengths are beginning.