Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

A Submillimeter Wave SIS Receiver for 547 GHz

William R. McGrath, Pascal Febvre, Hamid Javadi, Morvan C. Salez, P. D. Batelaan, M. A. Frerking

Published Mar 30, 1993• 4 citations
OpenAlex

Abstract

The most sensitive heterodyne receivers used for millimeter wave and submillimeter wave radioastronomy employ superconductor-insulator-superconductor tunnel junctions as the nonlinear mixing element.

Related papers

A Submillimeter Wave SIS Heterodyne Receiver Using Nb Tunnel Junctions with Integrated Tuning Circuits for 626 GHz

Morvan C. Salez, William R. McGrath, Pascal Febvre +2 more

So far, the most sensitive heterodyne receivers in the millimeter-wave and submillimeter-wave frequency ranges have used the mixing response of the quasiparticle currents in SIS tunnel junctions.

•Aug 11, 1993•0 citations

Micromachined Millimeter- and Submillimeter-wave SIS Heterodyne Receivers for Remote Sensing

Qing Hu

A heterodyne mixer with a micromachined horn antenna and a superconductor -insulator-superconductor (SIS) tunnel junction as mixing element is tested in the W-band (75-115 GHz) frequency range. Micromachined integrated horn antennas consist of a dipole antenna suspended on a thin Si3N4 dielectric membrane inside a pyramidal cavity etched in silicon. The mixer performance is optimized by using a backing plane behind the dipole antenna to tune out the capacitance of the tunnel junction. The lowest receiver noise temperature of 30+/-3 K without any correction) is measured at 106 GHz with a 3-dB bandwidth of 8 GHz. This sensitivity is comparable to the state-of-the-art waveguide and quasi-optical SIS receivers, showing the potential use of micromachined horn antennas in imaging arrays.

•May 29, 1997•0 citations

Performance of an SIS receiver over 460 GHz to 640 GHz using submicron Nb junctions with integrated RF tuning circuits

Pascal Febvre

The most sensitive heterodyne receivers used formillimeter wave and submillimeter wave radioastronomyemploy superconductor-insulator-superconductor (SIS)tunnel junctions as the nonlinear mixing element. Goodperformance has recently been reported for SIS junctionsused in planar mixer circuits and waveguide mixers fromabout 300 GHz to 500 GHz. We have developed asubmillimeter wave SIS heterodyne receiver for observingimportant rotational transitions of molecules in theinterstellar medium near 550 GHz and 630 GHz. Thisreceiver is based on a waveguide mixer with an adjustablebackshort and E-plane tuner [1]. The mixer uses a highcurrent density, 0.25 gm2 Nb-A1Ox-Nb tunnel junctiondefined by electron beam lithography [2]. The capacitanceof the junction is compensated with an integrated RFsuperconductive microstrip tuning circuit. The receiverperformance has been measured over the frequency range460 GHz to 640 GHz. DSB receiver noise temperatures aslow as 200 ± 17 K at 540 GHz and 362 ± 33 K at626 GHz have been obtained. In addition, negativedifferential resistance has been observed in the DC I-Vcurve at frequencies around 491 GHz. These results indicatethat the superconductive Nb microstrip transmission linesused in the tuning circuits are low-loss and perform well upto at least 90% of the superconductor energy gap frequency.

International Conference on Infrared, Millimeter, and Terahertz Waves (IRMMW-THz)•Aug 30, 1993•0 citations

Recent progress in submillimeter and terahertz heterodyne receivers with superconducting mixers.

Karl Jacobs

•Jan 1, 1998•1 citation

Heterodyne mixing at 70 GHz with superconductor-insulator-superconductor tunnel junctions

Hans J. Hartfuss, K. H. Gundlach

International Journal of Infrared and Millimeter Waves•Sep 1, 1981•9 citations

Superconducting Sensors for Submillimeter Heterodyne Receiver Systems

Henry George LeDuc, B. Bumble, Koko G. Megerian +1 more

•Jan 1, 1996•0 citations
A heterodyne mixer with a micromachined horn antenna and a superconductor -insulator-superconductor (SIS) tunnel junction as mixing element is tested in the W-band (75-115 GHz) frequency range. Micromachined integrated horn antennas consist of a dipole antenna suspended on a thin Si3N4 dielectric membrane inside a pyramidal cavity etched in silicon. The mixer performance is optimized by using a backing plane behind the dipole antenna to tune out the capacitance of the tunnel junction. The lowest receiver noise temperature of 30+/-3 K without any correction) is measured at 106 GHz with a 3-dB bandwidth of 8 GHz. This sensitivity is comparable to the state-of-the-art waveguide and quasi-optical SIS receivers, showing the potential use of micromachined horn antennas in imaging arrays.
The most sensitive heterodyne receivers used formillimeter wave and submillimeter wave radioastronomyemploy superconductor-insulator-superconductor (SIS)tunnel junctions as the nonlinear mixing element. Goodperformance has recently been reported for SIS junctionsused in planar mixer circuits and waveguide mixers fromabout 300 GHz to 500 GHz. We have developed asubmillimeter wave SIS heterodyne receiver for observingimportant rotational transitions of molecules in theinterstellar medium near 550 GHz and 630 GHz. Thisreceiver is based on a waveguide mixer with an adjustablebackshort and E-plane tuner [1]. The mixer uses a highcurrent density, 0.25 gm2 Nb-A1Ox-Nb tunnel junctiondefined by electron beam lithography [2]. The capacitanceof the junction is compensated with an integrated RFsuperconductive microstrip tuning circuit. The receiverperformance has been measured over the frequency range460 GHz to 640 GHz. DSB receiver noise temperatures aslow as 200 ± 17 K at 540 GHz and 362 ± 33 K at626 GHz have been obtained. In addition, negativedifferential resistance has been observed in the DC I-Vcurve at frequencies around 491 GHz. These results indicatethat the superconductive Nb microstrip transmission linesused in the tuning circuits are low-loss and perform well upto at least 90% of the superconductor energy gap frequency.