Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Acta Optica Sinica

冷原子及超冷原子干涉陀螺仪(特邀)

岳柯伟 Yue Kewei, 樊耀塬 Fan Yaoyuan, 曹朗 Cao Lang, 王青 Wang Qing, 张球新 Zhang Qiuxin, 胡栋 Hu Dong, 王宇 Wang Yu, 周小计 Zhou Xiaoji

Published Jan 1, 2025• 1 citation
Publisher

Abstract

Significance A gyroscope is a core sensor for measuring the angular velocity of an object’s motion. It is designed to calibrate the position, attitude, and heading of navigation systems, with its precision directly determining the reliability of positioning systems. Traditional mechanical gyroscopes, micro-electro-mechanical system (MEMS) gyroscopes, and optical gyroscopes are constrained by factors such as mechanical wear, machining precision, and size, thus limiting their application scenarios and making it difficult to further improve long-term stability. Cold atom and ultracold atom interferometric gyroscopes based on the matter wave Sagnac effect utilize laser cooling technology to reduce atoms to the μK to nK temperature range, significantly enhancing matter-wave coherence. Their theoretical sensitivity is 1011 times higher than that of optical interferometers, with long-term stability potentially reaching the order of 10-16 rad/s. This provides a new solution to overcoming traditional technological bottlenecks and achieving strategic-grade inertial navigation. Simultaneously, cold atom and ultracold atom interferometric gyroscopes can overcome the limitations of thermal atom gyroscopes, such as shorter atomic coherence time and bulky interferometric setups. While preserving the advantages of matter-wave interferometry, they possess the potential for integration and miniaturization, holding application significance in the fields of national defense and security, space science, and civil positioning. Progress Atom interferometric gyroscopes developed to date can be divided based on atomic source temperature characteristics into thermal atom, cold atom, and ultracold atom interferometric gyroscopes. Current experimental thermal atom interferometric gyroscopes have achieved long-term stability on the order of 10-10 rad/s. However, their short atomic coherence time and large interferometric setups have led to the proposal of various schemes adopting cold atoms as the interference source. Cold atom interferometric gyroscopes are primarily divided into two types based on the atomic source type and manipulation method, including the continuous atomic beam type and pulsed atomic cloud type. The method by employing continuous cold atomic beams preserves the advantage of high bandwidth characteristics of thermal atomic beam interferometric gyroscopes while effectively reducing device size without sacrificing sensitivity (Fig. 3). The pulsed cloud scheme for cold atom interferometric gyroscopes employs discretely launched cold atom clouds, utilizing designed laser pulse sequences to coherently split, reflect, and recombine atomic wave packets, and constructing spatially separated Sagnac interference loops. These devices typically adopt a projectile configuration (Figs. 4 and 5). Depending on the laser pulse sequence adopted during the interference experiment, they can be further divided into three-pulse and four-pulse types. Three-pulse sequence interferometers usually employ two identical, counter propagating atom clouds launched toward each other to form a dual interference loop. Four-pulse sequence interferometers often utilize a single atom cloud launched to form a butterfly shaped interference loop. Compared to atomic beam gyroscopes, they have advantages in the more flexible manipulation of coherent atoms. Ultracold atom interferometric gyroscopes developed from cold atom gyroscopes utilize laser cooling and evaporative cooling techniques to prepare neutral atoms (such as 87Rb) in the nK temperature range, forming Bose-Einstein condensates (BECs). Their unique quantum properties provide key advantages for building high-performance atom interferometric gyroscopes. On the one hand, longer coherence time allows for the design of more complex interference paths such as multi-loop circuits, enabling larger effective Sagnac interference areas within limited physical space. On the other hand, ultracold atoms can be precisely confined and guided by electromagnetic fields (magnetic traps, optical traps), enabling highly controllable, compact interference loop configurations that significantly enhance measurement sensitivity per unit volume (Figs. 6?10). These schemes demonstrate the unique advantages of cold atom and ultracold atom interferometry in terms of sensitivity, stability, and multi-dimensional sensing, providing new avenues for the further development of inertial navigation technology. Conclusions and Prospects Cold atom and ultracold atom interferometric gyroscopes based on matter-wave interference principles feature significant development potential. Current research has validated the feasibility of various technical approaches and yielded notable results. However, much of the research remains at the laboratory stage, with a gap remaining to achieve theoretical precision limits and engineering applications. Future efforts should be focus on further integrating the advantages of multiple disciplines, improving measurement accuracy and stability, and intensifying research on engineering applications. In the long term, with the maturation of quantum control technology and micronano fabrication processes, practical, miniaturized, and integrated inertial units are expected to emerge. This will promote atomic gyroscopes from the laboratory stage into real applications, redefining the precision limits of inertial navigation.

DOI
10.3788/aos251521

Related papers

High-performance gyroscope for rotational seismology.

Nathan Marliere, Mohamed Guessoum, Rémi Geiger +1 more

The Sagnac effect is at the heart of the modern precision inertial sensors. An interferometer with a physical area, when spun, exhibits a phase shift atits output. Measuring this phase-shift leads to a direct measurement of the rotation rate.The SYRTE dual-axis cold-atom gyroscope represents the state-of-art of atomic gyroscopes. With its large physical area (11cm2) and a long interrogation time of 800 ms, it offers both the sensitivity and stability 3 × 10^10 rad.s−1 to push the Sagnac measurement to an unprecedented accuracy level. Demonstrating such performance required the control and characterization of the experimental parameters and systematic effects and the precise knowledge of the scale factor. The cold-atom gyroscope experiment is based on atomic interferometry, where cooled Cesium-atoms (2μK) are launched vertically (∼ 5m/s) to be interrogated with a sequence of four Raman pulses (allowing an internal and external control over atomic states). The pulses play the role of atomic optics by splitting and guiding the matter-waves along the arms of the interferometer. By the end, transition probability measurement gives access to the phase-shift induced by rotation.I will present our recent work done to develop new methods that will improve the gyroscope sensitivity. The Double diffraction, atom diffraction inboth ±¯h⃗keff directions, should enables a measurement setup with no dead time based on the use of two correlated interleaved interferometers. Thus, the vibration and rotation noises that limits the sensitivity should average to achieve the detection noise, targeting the standard quantum projection noise.

•Sep 5, 2023•0 citations

Research Status and Prospects of Cold Atom Interferometry Gyroscope in Inertial Navigation Fields

Wei Chun-hu

With the progress of laser cooling and other atom optics technologies, the cold atom interferometry gyroscope based on cold atom wave is developing rapidly, and it promises to be a novel gyroscope technology in inertial navigation areas. The research status of cold atom interferometry gyroscope and the principle of atom interferometry are introduced, and a comparative analysis of the characteristics among the three distinct types of cold atom interferometry gyroscopes in Stanford University, Observatoire de Paris and Hanover University is carried out. The improving schemes and developing prospects of cold atom interferometry gyroscope are discussed by focusing on its current limitations, aiming at its wider application in inertial navigation fields.

Modern Navigation•Jan 1, 2013•1 citation

Development of compact cold-atom sensors for inertial navigation

Baptiste Battelier, B. Barrett, Lauriane Fouché +7 more

Inertial sensors based on cold atom interferometry exhibit many interesting features for applications related to inertial navigation, particularly in terms of sensitivity and long-term stability. However, at present the typical atom interferometer is still very much an experiment—consisting of a bulky, static apparatus with a limited dynamic range and high sensitivity to environmental effects. To be compliant with mobile applications further development is needed. In this work, we present a compact and mobile experiment, which we recently used to achieve the first inertial measurements with an atomic accelerometer onboard an aircraft. By integrating classical inertial sensors into our apparatus, we are able to operate the atomic sensor well beyond its standard operating range, corresponding to half of an interference fringe. We report atom-based acceleration measurements along both the horizontal and vertical axes of the aircraft with one-shot sensitivities of 2.3 × 10−4 g over a range of ∼ 0.1 g. The same technology can be used to develop cold-atom gyroscopes, which could surpass the best optical gyroscopes in terms of long-term sensitivity. Our apparatus was also designed to study multi-axis atom interferometry with the goal of realizing a full inertial measurement unit comprised of the three axes of acceleration and rotation. Finally, we present a compact and tunable laser system, which constitutes an essential part of any cold-atom-based sensor. The architecture of the laser is based on phase modulating a single fiber-optic laser diode, and can be tuned over a range of 1 GHz in less than 200 μs.

arXiv:1605.02454•Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Apr 29, 2016•94 citations

Interferometry with Bose-Einstein condensates for inertial sensing

Sven Abend

Matter-wave interferometers show great a potential for improving inertial sensing. The absence of drifts recommends them for a variety of applications in geodesy, navigation, or fundamental physics. Here, ultracold atomic ensembles, featuring a velocity distribution well below the photon recoil velocity, open up new perspectives. In contrast to standard laser cooling methods, they allow to reach better beam-splitting efficiencies and, hence, a higher contrast as well as to reduce systematic uncertainties and biases. Presently, Bose-Einstein condensates (BECs) provide the means to achieve the lowest expansion energies of few picokelvin. Indeed, the momentum distribution of a BEC can be further narrowed after reaching the regime of ballistic expansion, where all mean field energy is converted to kinetic energy, by the application of the delta-kick collimation technique. With such ensembles, Bragg processes can be driven with an efficiency of above 95% as well as Bloch oscillations performed without large atomic losses or dephasing. Both enable efficient large momentum transfer in interferometers to enhance their sensitivity for inertial effects. In a so-called twin-lattice atom interferometers more than thousand photon recoils are used to form compact but sensitive atom interferometers. These methods not only bring in reach extremely accurate gravimeters and accelerometers but also gyroscopes. Like the Sagnac effect in ring laser or fiber gyroscopes, the sensitivity of atom interferometers to rotations increases with the space-time area enclosed by the interferometer. In the case of light interferometers, the latter can be enlarged by forming multiple fiber loops. However, the equivalent for matter-wave interferometers remains an experimental challenge. An atom interferometer with scalable area may be formed in a twin lattice combined with a relaunch mechanism to obtain multi loops as well. Due to this scalability, it offers the perspective of reaching unprecedented sensitivities for rotations in comparably compact sensor head setups. Moreover, atom-chip technologies offer the possibility to generate a BEC and perform delta-kick collimation in a fast and reliable away, paving the way for field-deployable miniaturized atomic devices. Last but not least, the extremely low expansion energies of BECs open up to extend the time atoms spend in the interferometer to tens of seconds. This brings in reach unprecedented sensitivities in space-borne applications such as satellite geodesy.

SPIE Quantum Technologies for Defence and Security•Nov 15, 2024•0 citations

CONSTRUCTION AND CHARACTERIZATION OF A DUAL ATOMIC BEAM ACCELEROMETER/GYROSCOPE

Michael Manicchia

Current sensors used for inertial navigation are based on technology with inherent sensitivity limitations. Atom interferometry is a very promising replacement, which could yield many orders of magnitude of improvement in sensitivity, leading to more accurate navigation over longer periods of time relative to current technology. This research investigates the physics of atom interferometry through the construction and characterization of an atomic accelerometer/gyroscope combination. In contrast to current state-of-the-art atomic sensors, which use pulsed cold atom sources and pulsed laser beams, the apparatus investigated relies purely on continuous atomic and laser beams. These differences would result in a sensor that lends itself more readily to smaller sizing, lower power consumption, and reduced complexity. This change in approach to atomic interferometry also introduces challenges resulting from laser and atomic beam divergences and the velocity averaging due to both longitudinal and transverse temperature, which this dissertation shows how to overcome. The work contained herein explores many stages of construction of an atomic gyro including the demonstration and characterization of two-dimensional laser cooling of atoms, stimulated Raman transitions, and Ramsey and spin echo interference. The implications for future research are also outlined and discussed.

•Jun 1, 2020•2 citations

Limits on the sensitivity of a cold atom interferometry gyroscope

Wenjie Xu, Lele Chen, Ming-Jie Nie +2 more

We present a precision atom interferometry gyroscope with a Sagnac area of 6.0 cm 2 . To drive the cold atom interferometry gyroscope, we utilize two sets of Raman beams with a pulse sequence of π /2- π - π - π /2. We present a procedure for aligning the two sets of Raman beams at the microradian level by making use of the atom interferometer itself in different configurations. Additionally, we measured the atomic cloud trajectory and implemented a spatial symmetry alignment for the atom interferometer. With these improvements, we construct a sensitive atom gyroscope with a stability of 1 nrad/s at an integration time of 10000 s. We analyzed the influence of Raman beams and the limitations of the system, and present the technical limits to the sensitivity and long-term stability. Finally, we point out the primary sources of noise in the atom interferometry gyroscope, clearing the way for the construction of further large-area atom gyroscopes.

Optics Express•Nov 8, 2024•8 citations
Significance A gyroscope is a core sensor for measuring the angular velocity of an object’s motion. It is designed to calibrate the position, attitude, and heading of navigation systems, with its precision directly determining the reliability of positioning systems. Traditional mechanical gyroscopes, micro-electro-mechanical system (MEMS) gyroscopes, and optical gyroscopes are constrained by factors such as mechanical wear, machining precision, and size, thus limiting their application scenarios and making it difficult to further improve long-term stability. Cold atom and ultracold atom interferometric gyroscopes based on the matter wave Sagnac effect utilize laser cooling technology to reduce atoms to the μK to nK temperature range, significantly enhancing matter-wave coherence. Their theoretical sensitivity is 1011 times higher than that of optical interferometers, with long-term stability potentially reaching the order of 10-16 rad/s. This provides a new solution to overcoming traditional technological bottlenecks and achieving strategic-grade inertial navigation. Simultaneously, cold atom and ultracold atom interferometric gyroscopes can overcome the limitations of thermal atom gyroscopes, such as shorter atomic coherence time and bulky interferometric setups. While preserving the advantages of matter-wave interferometry, they possess the potential for integration and miniaturization, holding application significance in the fields of national defense and security, space science, and civil positioning. Progress Atom interferometric gyroscopes developed to date can be divided based on atomic source temperature characteristics into thermal atom, cold atom, and ultracold atom interferometric gyroscopes. Current experimental thermal atom interferometric gyroscopes have achieved long-term stability on the order of 10-10 rad/s. However, their short atomic coherence time and large interferometric setups have led to the proposal of various schemes adopting cold atoms as the interference source. Cold atom interferometric gyroscopes are primarily divided into two types based on the atomic source type and manipulation method, including the continuous atomic beam type and pulsed atomic cloud type. The method by employing continuous cold atomic beams preserves the advantage of high bandwidth characteristics of thermal atomic beam interferometric gyroscopes while effectively reducing device size without sacrificing sensitivity (Fig. 3). The pulsed cloud scheme for cold atom interferometric gyroscopes employs discretely launched cold atom clouds, utilizing designed laser pulse sequences to coherently split, reflect, and recombine atomic wave packets, and constructing spatially separated Sagnac interference loops. These devices typically adopt a projectile configuration (Figs. 4 and 5). Depending on the laser pulse sequence adopted during the interference experiment, they can be further divided into three-pulse and four-pulse types. Three-pulse sequence interferometers usually employ two identical, counter propagating atom clouds launched toward each other to form a dual interference loop. Four-pulse sequence interferometers often utilize a single atom cloud launched to form a butterfly shaped interference loop. Compared to atomic beam gyroscopes, they have advantages in the more flexible manipulation of coherent atoms. Ultracold atom interferometric gyroscopes developed from cold atom gyroscopes utilize laser cooling and evaporative cooling techniques to prepare neutral atoms (such as 87Rb) in the nK temperature range, forming Bose-Einstein condensates (BECs). Their unique quantum properties provide key advantages for building high-performance atom interferometric gyroscopes. On the one hand, longer coherence time allows for the design of more complex interference paths such as multi-loop circuits, enabling larger effective Sagnac interference areas within limited physical space. On the other hand, ultracold atoms can be precisely confined and guided by electromagnetic fields (magnetic traps, optical traps), enabling highly controllable, compact interference loop configurations that significantly enhance measurement sensitivity per unit volume (Figs. 6?10). These schemes demonstrate the unique advantages of cold atom and ultracold atom interferometry in terms of sensitivity, stability, and multi-dimensional sensing, providing new avenues for the further development of inertial navigation technology. Conclusions and Prospects Cold atom and ultracold atom interferometric gyroscopes based on matter-wave interference principles feature significant development potential. Current research has validated the feasibility of various technical approaches and yielded notable results. However, much of the research remains at the laboratory stage, with a gap remaining to achieve theoretical precision limits and engineering applications. Future efforts should be focus on further integrating the advantages of multiple disciplines, improving measurement accuracy and stability, and intensifying research on engineering applications. In the long term, with the maturation of quantum control technology and micronano fabrication processes, practical, miniaturized, and integrated inertial units are expected to emerge. This will promote atomic gyroscopes from the laboratory stage into real applications, redefining the precision limits of inertial navigation.
The Sagnac effect is at the heart of the modern precision inertial sensors. An interferometer with a physical area, when spun, exhibits a phase shift atits output. Measuring this phase-shift leads to a direct measurement of the rotation rate.The SYRTE dual-axis cold-atom gyroscope represents the state-of-art of atomic gyroscopes. With its large physical area (11cm2) and a long interrogation time of 800 ms, it offers both the sensitivity and stability 3 × 10^10 rad.s−1 to push the Sagnac measurement to an unprecedented accuracy level. Demonstrating such performance required the control and characterization of the experimental parameters and systematic effects and the precise knowledge of the scale factor. The cold-atom gyroscope experiment is based on atomic interferometry, where cooled Cesium-atoms (2μK) are launched vertically (∼ 5m/s) to be interrogated with a sequence of four Raman pulses (allowing an internal and external control over atomic states). The pulses play the role of atomic optics by splitting and guiding the matter-waves along the arms of the interferometer. By the end, transition probability measurement gives access to the phase-shift induced by rotation.I will present our recent work done to develop new methods that will improve the gyroscope sensitivity. The Double diffraction, atom diffraction inboth ±¯h⃗keff directions, should enables a measurement setup with no dead time based on the use of two correlated interleaved interferometers. Thus, the vibration and rotation noises that limits the sensitivity should average to achieve the detection noise, targeting the standard quantum projection noise.
With the progress of laser cooling and other atom optics technologies, the cold atom interferometry gyroscope based on cold atom wave is developing rapidly, and it promises to be a novel gyroscope technology in inertial navigation areas. The research status of cold atom interferometry gyroscope and the principle of atom interferometry are introduced, and a comparative analysis of the characteristics among the three distinct types of cold atom interferometry gyroscopes in Stanford University, Observatoire de Paris and Hanover University is carried out. The improving schemes and developing prospects of cold atom interferometry gyroscope are discussed by focusing on its current limitations, aiming at its wider application in inertial navigation fields.
Inertial sensors based on cold atom interferometry exhibit many interesting features for applications related to inertial navigation, particularly in terms of sensitivity and long-term stability. However, at present the typical atom interferometer is still very much an experiment—consisting of a bulky, static apparatus with a limited dynamic range and high sensitivity to environmental effects. To be compliant with mobile applications further development is needed. In this work, we present a compact and mobile experiment, which we recently used to achieve the first inertial measurements with an atomic accelerometer onboard an aircraft. By integrating classical inertial sensors into our apparatus, we are able to operate the atomic sensor well beyond its standard operating range, corresponding to half of an interference fringe. We report atom-based acceleration measurements along both the horizontal and vertical axes of the aircraft with one-shot sensitivities of 2.3 × 10−4 g over a range of ∼ 0.1 g. The same technology can be used to develop cold-atom gyroscopes, which could surpass the best optical gyroscopes in terms of long-term sensitivity. Our apparatus was also designed to study multi-axis atom interferometry with the goal of realizing a full inertial measurement unit comprised of the three axes of acceleration and rotation. Finally, we present a compact and tunable laser system, which constitutes an essential part of any cold-atom-based sensor. The architecture of the laser is based on phase modulating a single fiber-optic laser diode, and can be tuned over a range of 1 GHz in less than 200 μs.
Matter-wave interferometers show great a potential for improving inertial sensing. The absence of drifts recommends them for a variety of applications in geodesy, navigation, or fundamental physics. Here, ultracold atomic ensembles, featuring a velocity distribution well below the photon recoil velocity, open up new perspectives. In contrast to standard laser cooling methods, they allow to reach better beam-splitting efficiencies and, hence, a higher contrast as well as to reduce systematic uncertainties and biases. Presently, Bose-Einstein condensates (BECs) provide the means to achieve the lowest expansion energies of few picokelvin. Indeed, the momentum distribution of a BEC can be further narrowed after reaching the regime of ballistic expansion, where all mean field energy is converted to kinetic energy, by the application of the delta-kick collimation technique. With such ensembles, Bragg processes can be driven with an efficiency of above 95% as well as Bloch oscillations performed without large atomic losses or dephasing. Both enable efficient large momentum transfer in interferometers to enhance their sensitivity for inertial effects. In a so-called twin-lattice atom interferometers more than thousand photon recoils are used to form compact but sensitive atom interferometers. These methods not only bring in reach extremely accurate gravimeters and accelerometers but also gyroscopes. Like the Sagnac effect in ring laser or fiber gyroscopes, the sensitivity of atom interferometers to rotations increases with the space-time area enclosed by the interferometer. In the case of light interferometers, the latter can be enlarged by forming multiple fiber loops. However, the equivalent for matter-wave interferometers remains an experimental challenge. An atom interferometer with scalable area may be formed in a twin lattice combined with a relaunch mechanism to obtain multi loops as well. Due to this scalability, it offers the perspective of reaching unprecedented sensitivities for rotations in comparably compact sensor head setups. Moreover, atom-chip technologies offer the possibility to generate a BEC and perform delta-kick collimation in a fast and reliable away, paving the way for field-deployable miniaturized atomic devices. Last but not least, the extremely low expansion energies of BECs open up to extend the time atoms spend in the interferometer to tens of seconds. This brings in reach unprecedented sensitivities in space-borne applications such as satellite geodesy.
Current sensors used for inertial navigation are based on technology with inherent sensitivity limitations. Atom interferometry is a very promising replacement, which could yield many orders of magnitude of improvement in sensitivity, leading to more accurate navigation over longer periods of time relative to current technology. This research investigates the physics of atom interferometry through the construction and characterization of an atomic accelerometer/gyroscope combination. In contrast to current state-of-the-art atomic sensors, which use pulsed cold atom sources and pulsed laser beams, the apparatus investigated relies purely on continuous atomic and laser beams. These differences would result in a sensor that lends itself more readily to smaller sizing, lower power consumption, and reduced complexity. This change in approach to atomic interferometry also introduces challenges resulting from laser and atomic beam divergences and the velocity averaging due to both longitudinal and transverse temperature, which this dissertation shows how to overcome. The work contained herein explores many stages of construction of an atomic gyro including the demonstration and characterization of two-dimensional laser cooling of atoms, stimulated Raman transitions, and Ramsey and spin echo interference. The implications for future research are also outlined and discussed.
We present a precision atom interferometry gyroscope with a Sagnac area of 6.0 cm 2 . To drive the cold atom interferometry gyroscope, we utilize two sets of Raman beams with a pulse sequence of π /2- π - π - π /2. We present a procedure for aligning the two sets of Raman beams at the microradian level by making use of the atom interferometer itself in different configurations. Additionally, we measured the atomic cloud trajectory and implemented a spatial symmetry alignment for the atom interferometer. With these improvements, we construct a sensitive atom gyroscope with a stability of 1 nrad/s at an integration time of 10000 s. We analyzed the influence of Raman beams and the limitations of the system, and present the technical limits to the sensitivity and long-term stability. Finally, we point out the primary sources of noise in the atom interferometry gyroscope, clearing the way for the construction of further large-area atom gyroscopes.