Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Physical Review Applied

Laser-noise-immune pulsed optically pumped atomic clock by means of differential detection

Xuejie Li, Yuhan Yan, Bowen Yang, Haojie Zhao, Jianliao Deng, Hua-Dong Cheng, L. Q. Chen

Published Sep 2, 2025• 0 citations
Publisher
DOI
10.1103/4p63-nttz

Related papers

Progress of Orthogonal Polarization Detection Technology in Pulsed Optically Pumped Atomic Clock

林锦达 Lin Jinda, 邓见辽 Deng Jianliao, 马易升 Ma Yisheng +2 more

Laser & Optoelectronics Progress•Jan 1, 2013•0 citations

Research on Atomic Phase Feedback in Pulsed Optically Pumped Atomic Clocks

Gongxun Dong, 林锦达 Lin Jinda, 张 松 Zhang Song +2 more

Acta Optica Sinica•Jan 1, 2017•1 citation

Pulsed vapor cell atomic clock with a differential Faraday rotation angle detection

Kemu Wang, Zhijing Du, Yanyan Liu +5 more

Laser intensity noise is one of the main limiting factors in pulsed vapor cell clocks. To reduce the contribution of the laser intensity noise to detection signal in the pulsed optically pumped atomic clock, a scheme based on the differential Faraday rotation angle is proposed. Theoretically, the Ramsey fringes, the sensitivity of clock frequency to laser intensity fluctuation and the signal to noise ratio for absorption, differential, and Faraday rotation angle methods are calculated and compared. Using a Wollaston prism rotated 45°relative to the incident polarization, and two photodetectors, Ramsey fringes of three detection methods are obtained simultaneously. In the proposed scheme, the long-term Faraday rotation angle fluctuation is 0.66% at 30000s, which is much smaller than fluctuation of traditional absorption signal 3.9% at 30000s. And the contribution of laser intensity noise to clock instability is also reduced. Using optimized photodetector with high common mode rejection ratio, a better performance should be expected. This proposed scheme is attractive for the development of high performance vapor clock based on pulsed optically pumped.

Optics Express•Oct 28, 2021•5 citations

Squeezing and Quantum Noise Quenching in Optically Pumped Atomic Clocks

G. M. Saxena, B.S. Mathur

Springer eBooks•Jan 1, 1993•0 citations

Pulsed optically pumped rubidium atomic clock with optical detection

I. H. Choi, Y.-H. Park, S. H. Lee +3 more

We describe the ongoing work on a87Rb vapor-cell atomic clock using pulsed optical pumping with an optical detection technique. In order to eliminate the light shifts and to increase the stability of vapor-cell atomic clock, pulsed optical pumping technique has been used. For simplicity, direct laser absorption signal is used for the detection of a clock transition.

Conference on Precision Electromagnetic Measurements•Jun 1, 2008•0 citations

Improvement of short-term stability of pulsed optically pumped rubidium atomic clock

I. H. Choi, S. B. Lee, Taeg Yong Kwon +1 more

We present a87Rb vapor-cell atomic clock using pulsed optical pumping with an optical detection technique. The pulsed optical pumping technique can eliminate the light shifts and increase the stability of vapor-cell atomic clock. For simplicity, direct laser absorption signal is used for the detection of a clock transition. A frequency stability of about 2×10-11at 1s has been measured and short term stability is improved by reducing the pulse sequence time with a real time control system.

•Jun 1, 2010•1 citation
Laser intensity noise is one of the main limiting factors in pulsed vapor cell clocks. To reduce the contribution of the laser intensity noise to detection signal in the pulsed optically pumped atomic clock, a scheme based on the differential Faraday rotation angle is proposed. Theoretically, the Ramsey fringes, the sensitivity of clock frequency to laser intensity fluctuation and the signal to noise ratio for absorption, differential, and Faraday rotation angle methods are calculated and compared. Using a Wollaston prism rotated 45°relative to the incident polarization, and two photodetectors, Ramsey fringes of three detection methods are obtained simultaneously. In the proposed scheme, the long-term Faraday rotation angle fluctuation is 0.66% at 30000s, which is much smaller than fluctuation of traditional absorption signal 3.9% at 30000s. And the contribution of laser intensity noise to clock instability is also reduced. Using optimized photodetector with high common mode rejection ratio, a better performance should be expected. This proposed scheme is attractive for the development of high performance vapor clock based on pulsed optically pumped.