Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Springer eBooks

Squeezing and Quantum Noise Quenching in Optically Pumped Atomic Clocks

G. M. Saxena, B.S. Mathur

Published Jan 1, 1993• 0 citations
Publisher
DOI
10.1007/978-1-4615-2936-1_32

Related papers

Laser-noise-immune pulsed optically pumped atomic clock by means of differential detection

Xuejie Li, Yuhan Yan, Bowen Yang +4 more

Physical Review Applied•Sep 2, 2025•0 citations

Research on Atomic Phase Feedback in Pulsed Optically Pumped Atomic Clocks

Gongxun Dong, 林锦达 Lin Jinda, 张 松 Zhang Song +2 more

Acta Optica Sinica•Jan 1, 2017•1 citation

Squeezing and quantum noise quenching in masers and lasers through atomic coherence and pump noise reduction

Claus Benkert, Marlan O. Scully, János A. Bergou +1 more

Atomic coherence, when combined with a reduction of pump noise, can lead to significant noise quenching in lasers and even squeezing in masers. Furthermore, this noise reduction can be modified in an interesting way by atomic broadening.

Physical Review A•Apr 1, 1990•8 citations

Frequency stability of a pulsed optically pumped atomic clock with narrow Ramsey linewidth

Haixiao Lin, Jianliao Deng, Jinda Lin +2 more

In general, the linewidth of the Ramsey central fringe (RCF) is equal to 1/(2T), where T is the Ramsey free-evolution time. We demonstrate that the RCF linewidth of a pulsed optically pumped (POP) atomic clock with orthogonal polarization detection based on the magneto-optical rotation effect can be narrowed down to 1/(4T). The Allan deviation of the POP atomic clock decreases from 2.4×10−13τ−1/2 to 1.4×10−13τ−1/2. This corresponds to an improvement in the frequency stability by about 60%. We also estimate the main noise sources that limit the short-term frequency stability of the POP atomic clock.

Applied Optics•Apr 12, 2018•14 citations

Progress toward a spin squeezed optical atomic clock beyond the standard quantum limit

Boris Braverman, Akio Kawasaki, Vladan Vuletić

Bulletin of the American Physical Society•Jun 11, 2015•0 citations

An optically pumped atomic clock based on a continuous slow cesium beam

Weibin Xie, Qing Wang, Xuan He +8 more

Herein, we report the scheme of an optically pumped atomic clock based on a cold cesium atomic beam source. We propose the laser system and physical mechanism of this atomic clock, wherein the atomic beam travels in an upper parabolic trajectory, thereby eliminating the light shift effect. In the experiments, when the length of the free evolution region was 167 mm, the line width of the Ramsey fringe was 37 Hz. When the expected signal-to-noise ratio of the Ramsey fringe that can be achieved is 36,000, the expected short-term frequency stability is about 3.6 × 10–14/√τ, which is significantly higher than that of a conventional optically pumped cesium clock of similar volume.

Frontiers in Physics•Dec 13, 2022•3 citations
In general, the linewidth of the Ramsey central fringe (RCF) is equal to 1/(2T), where T is the Ramsey free-evolution time. We demonstrate that the RCF linewidth of a pulsed optically pumped (POP) atomic clock with orthogonal polarization detection based on the magneto-optical rotation effect can be narrowed down to 1/(4T). The Allan deviation of the POP atomic clock decreases from 2.4×10−13τ−1/2 to 1.4×10−13τ−1/2. This corresponds to an improvement in the frequency stability by about 60%. We also estimate the main noise sources that limit the short-term frequency stability of the POP atomic clock.
Herein, we report the scheme of an optically pumped atomic clock based on a cold cesium atomic beam source. We propose the laser system and physical mechanism of this atomic clock, wherein the atomic beam travels in an upper parabolic trajectory, thereby eliminating the light shift effect. In the experiments, when the length of the free evolution region was 167 mm, the line width of the Ramsey fringe was 37 Hz. When the expected signal-to-noise ratio of the Ramsey fringe that can be achieved is 36,000, the expected short-term frequency stability is about 3.6 × 10–14/√τ, which is significantly higher than that of a conventional optically pumped cesium clock of similar volume.