Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Conference on Precision Electromagnetic Measurements

Pulsed optically pumped rubidium atomic clock with optical detection

I. H. Choi, Y.-H. Park, S. H. Lee, J. K. Lee, Taeg Yong Kwon, S. E. Park

Published Jun 1, 2008• 0 citations
Publisher

Abstract

We describe the ongoing work on a87Rb vapor-cell atomic clock using pulsed optical pumping with an optical detection technique. In order to eliminate the light shifts and to increase the stability of vapor-cell atomic clock, pulsed optical pumping technique has been used. For simplicity, direct laser absorption signal is used for the detection of a clock transition.

DOI
10.1109/cpem.2008.4574926

Related papers

Improvement of short-term stability of pulsed optically pumped rubidium atomic clock

I. H. Choi, S. B. Lee, Taeg Yong Kwon +1 more

We present a87Rb vapor-cell atomic clock using pulsed optical pumping with an optical detection technique. The pulsed optical pumping technique can eliminate the light shifts and increase the stability of vapor-cell atomic clock. For simplicity, direct laser absorption signal is used for the detection of a clock transition. A frequency stability of about 2×10-11at 1s has been measured and short term stability is improved by reducing the pulse sequence time with a real time control system.

•Jun 1, 2010•1 citation

THE PULSED OPTICALLY PUMPED CLOCK: MICROWAVE AND OPTICAL DETECTION

Salvatore Micalizio, Aldo Godone, Filippo Levi +1 more

We present theoretical and experimental studies concerning the realization of a rubidium vapor cell frequency standard based on the pulsed optical pumping (POP) technique. This technique is extremely powerful since it avoids in principle the light shift effect and the noise conversions from the laser to the clock signal. The detection of the clock transition in the microwave domain (the so called POP maser) has been extensively investigated at INRIM and a frequency stability of 1.1 × 10-12τ-1/2 has been measured until integration times of 105 s, reaching the level of 5 × 10-15 (drift removed). The optical detection is still under evaluation but this technique may lead in effect to some advantages with respect to the microwave detection, such as a lower or negligible cavity pulling, a lower operation temperature (which implies a lower spin exchange contribution) and a higher signal-to-noise ratio. All these features may lead to a better frequency stability performance than that previously reached. Read More: http://www.worldscientific.com/doi/abs/10.1142/9789812838223_0040

Symposium on Frequency Standards and Metrology•May 1, 2009•0 citations

Atomic Clock Using Microwave Pulse-Coherent Techniques

Maurice Arditi, T. R. Carver

In order to eliminate the light shifts and to increase the stability of gas-cell atomic clocks using optical pumping of the alkali atoms, the detection of a microwave pulse-induced coherent emission is used as the correction signal to lock a crystal oscillator to the atomic transition. Also, the line width of the O-O hyperfine transition is artificially narrowed by subjecting the atoms in the cell to two phase-coherent microwave pulses. In this case the resonance line has a width characteristic of the pulse-repetition frequency which can be made several times smaller than the natural line width in the cell. Proper timing of the sequence of microwave pulses and light pulses for optical pumping is necessary to conserve phase coherence and to obtain a well-defined Ramsey pattern. Results of the tests on a laboratory model using Rubidium-87 atoms show the elimination of the light shifts and an improvement of the short-term stability of the crystal oscillator by one order of magnitude.

IEEE Transactions on Instrumentation and Measurement•Jun 1, 1964•42 citations

Pulsed optically pumped rubidium clock with high frequency-stability performance

Salvatore Micalizio, A. Godone, Claudio Eligio Calosso +3 more

In this paper, we present the performance of a vapor-cell rubidium frequency standard working in the pulsed regime, in which the clock signal is represented by a Ramsey pattern observed on an optically detected laser absorption signal. The main experimental results agree with previously reported theoretical predictions. In particular, we measured a relative frequency stability of σy(τ) - 1.6 × 10(-13)τ-1/2 for integration times, τ, up to 200 s, which represents a record in short-term stability for a vapor-cell clock. We also discuss the most important physical phenomena that contribute to this result.

IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control•Mar 1, 2012•30 citations

A laser optically-pumped Rubidium vapour-cell frequency standard using a DFB laser diode

C. Affolderbach, G. Mileti, Fabien Droz

A laser optically-pumped vapour-cell atomic frequency standard ("Rb clock") using a DFB laser diode as pump light source is presented. The Rb clock is based on probing the ground-state hyperfine "clock" transition at 6.8 GHz of atomic87Rb, by optical-microwave double-resonance technique. The frequency stability of the clock is measured.

Conference on Lasers and Electro-Optics Europe & European Quantum Electronics Conference (CLEO/Europe-EQEC)•Jun 1, 2007•0 citations

Integrated pulsed optically pumped Rb atomic clock with frequency stability of 10 − 15

Qiang Hao, Shaojie Yang, Jun Ruan +2 more

Pulsed optically pumped (POP) Rb atomic clock is considered to be a powerful technique for the Rb atomic clock due to the capability of light-shift mitigation and atomic spectroscopy narrowing. Relevant investigations are conducted over two decades, however, no integrated prototype of such a kind of clock has been reported yet. Here, we present an integrated prototype of the POP Rb atomic clock and quantitatively characterize its physical properties. The atomic clock shows a short-term fractional frequency stability of $2.6\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}13}/\sqrt{\ensuremath{\tau}}$ (where $\ensuremath{\tau}$ is the averaging time), and comes to $2.3\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}15}$ with 40 000 s averaging (drift removed) under atmospheric conditions. Physical effects contributing to the long-term frequency stability are carefully analyzed and cavity-pulling shift is identified as the leading limit. The techniques presented here enable realizing a low ${10}^{\ensuremath{-}15}$ level vapor-cell atomic clock under atmospheric conditions, which could benefit a wide range of terrestrial applications, such as quantum communication, decimeter-level terrestrial positioning.

Physical Review Applied•Feb 1, 2024•14 citations
We describe the ongoing work on a87Rb vapor-cell atomic clock using pulsed optical pumping with an optical detection technique. In order to eliminate the light shifts and to increase the stability of vapor-cell atomic clock, pulsed optical pumping technique has been used. For simplicity, direct laser absorption signal is used for the detection of a clock transition.
We present theoretical and experimental studies concerning the realization of a rubidium vapor cell frequency standard based on the pulsed optical pumping (POP) technique. This technique is extremely powerful since it avoids in principle the light shift effect and the noise conversions from the laser to the clock signal. The detection of the clock transition in the microwave domain (the so called POP maser) has been extensively investigated at INRIM and a frequency stability of 1.1 × 10-12τ-1/2 has been measured until integration times of 105 s, reaching the level of 5 × 10-15 (drift removed). The optical detection is still under evaluation but this technique may lead in effect to some advantages with respect to the microwave detection, such as a lower or negligible cavity pulling, a lower operation temperature (which implies a lower spin exchange contribution) and a higher signal-to-noise ratio. All these features may lead to a better frequency stability performance than that previously reached. Read More: http://www.worldscientific.com/doi/abs/10.1142/9789812838223_0040
In order to eliminate the light shifts and to increase the stability of gas-cell atomic clocks using optical pumping of the alkali atoms, the detection of a microwave pulse-induced coherent emission is used as the correction signal to lock a crystal oscillator to the atomic transition. Also, the line width of the O-O hyperfine transition is artificially narrowed by subjecting the atoms in the cell to two phase-coherent microwave pulses. In this case the resonance line has a width characteristic of the pulse-repetition frequency which can be made several times smaller than the natural line width in the cell. Proper timing of the sequence of microwave pulses and light pulses for optical pumping is necessary to conserve phase coherence and to obtain a well-defined Ramsey pattern. Results of the tests on a laboratory model using Rubidium-87 atoms show the elimination of the light shifts and an improvement of the short-term stability of the crystal oscillator by one order of magnitude.
In this paper, we present the performance of a vapor-cell rubidium frequency standard working in the pulsed regime, in which the clock signal is represented by a Ramsey pattern observed on an optically detected laser absorption signal. The main experimental results agree with previously reported theoretical predictions. In particular, we measured a relative frequency stability of σy(τ) - 1.6 × 10(-13)τ-1/2 for integration times, τ, up to 200 s, which represents a record in short-term stability for a vapor-cell clock. We also discuss the most important physical phenomena that contribute to this result.
Pulsed optically pumped (POP) Rb atomic clock is considered to be a powerful technique for the Rb atomic clock due to the capability of light-shift mitigation and atomic spectroscopy narrowing. Relevant investigations are conducted over two decades, however, no integrated prototype of such a kind of clock has been reported yet. Here, we present an integrated prototype of the POP Rb atomic clock and quantitatively characterize its physical properties. The atomic clock shows a short-term fractional frequency stability of $2.6\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}13}/\sqrt{\ensuremath{\tau}}$ (where $\ensuremath{\tau}$ is the averaging time), and comes to $2.3\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}15}$ with 40 000 s averaging (drift removed) under atmospheric conditions. Physical effects contributing to the long-term frequency stability are carefully analyzed and cavity-pulling shift is identified as the leading limit. The techniques presented here enable realizing a low ${10}^{\ensuremath{-}15}$ level vapor-cell atomic clock under atmospheric conditions, which could benefit a wide range of terrestrial applications, such as quantum communication, decimeter-level terrestrial positioning.