Symposium on Frequency Standards and Metrology

THE PULSED OPTICALLY PUMPED CLOCK: MICROWAVE AND OPTICAL DETECTION

Salvatore Micalizio, Aldo Godone, Filippo Levi, Claudio Eligio Calosso

Published May 1, 2009• 0 citations
Publisher

Abstract

We present theoretical and experimental studies concerning the realization of a rubidium vapor cell frequency standard based on the pulsed optical pumping (POP) technique. This technique is extremely powerful since it avoids in principle the light shift effect and the noise conversions from the laser to the clock signal. The detection of the clock transition in the microwave domain (the so called POP maser) has been extensively investigated at INRIM and a frequency stability of 1.1 × 10-12τ-1/2 has been measured until integration times of 105 s, reaching the level of 5 × 10-15 (drift removed). The optical detection is still under evaluation but this technique may lead in effect to some advantages with respect to the microwave detection, such as a lower or negligible cavity pulling, a lower operation temperature (which implies a lower spin exchange contribution) and a higher signal-to-noise ratio. All these features may lead to a better frequency stability performance than that previously reached. Read More: http://www.worldscientific.com/doi/abs/10.1142/9789812838223_0040

DOI
10.1142/9789812838223_0040

Related papers

Study of Pulsed Optically Pumped Rb Frequency Standard

Shougang Zhang

The pulsed optically pumped(POP) 87Rb vapor-cell frequency standard was studied based on the detection of free induction microwave signal or optical absorption signal.In POP operation the pumping,interrogation,and detection phases are separated in time,avoiding the coupling between microwave and optical coherence.The theoretical results show that an oscillation period doubled with respect to the classical Ramsey method which leads to a doubled atomic quality factor Q,and the reduction of optical shift and cavity pulling shift will be obtained,when the atoms are submitted to π/2 Ramsey microwave pulse.In experiment Ramsey fringes were obtained with a clock prototype based on 87Rb in buffer gas,with bandwidth of 65 Hz and 150 Hz for microwave and optical signal respectively.The frequency stability achieved was 1.2×10-12 for measurement times up to 100 s.

Wuhan Daxue xuebao. Xinxi kexue ban•Jan 1, 2011•0 citations

Pulsed optically pumped Rb clock: A high stability vapor cell frequency standard

Filippo Levi, Claudio Eligio Calosso, A. Godone +1 more

In this paper we report the results we obtained with a prototype of pulsed optically pumped (POP) Rb clock. In terms of frequency stability, an Allan deviation σy(τ)=1.7 ×10-13τ-1/2has been measured, where τ is the integration time. In addition, the long term frequency drift results below 10-14/day. In the paper we also describe a technique to stabilize the amplitude of the microwave signal using the atoms themselves as discriminator. Moreover, an anomalously large temperature sensitivity of the clock frequency and a technique to keep it under control are also reported. Finally, we describe some non linear effects that modify the shape of the clock signal represented by the Ramsey central fringe.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•Jul 1, 2013•1 citation

Pulsed optically pumped Rb87 vapor cell frequency standard: A multilevel approach

Salvatore Micalizio, Aldo Godone, Filippo Levi +1 more

We present a multilevel theoretical approach to describe the behavior of a pulsed optically pumped (POP) $^{87}\mathrm{Rb}$ frequency standard based on a microwave cavity-vapor cell arrangement. The full Zeeman manifold of the ground-state hyperfine levels is then considered, and the dynamics induced among them by relaxation processes (buffer gas, spin exchange, and cell-walls collisions) is taken into account. The model includes as well the absorption of the pumping laser along the cell and the cavity feedback on the atoms; the effects related to a nonuniform excitation of the atomic sample are also discussed. Theoretical predictions are proven with a laboratory prototype of POP passive maser in which the clock transition is excited by means of the Ramsey technique. The agreement between theory and experiment is very satisfactory from both a quantitative and qualitative point of view, in terms of the shape of the Ramsey fringes, microwave power delivered by the atoms, and short-term frequency stability. In particular, a frequency stability of $1.2\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}12}$ at one second has been measured, in very good agreement with the expected value. On this basis, the model has been extended to predict the short-term frequency stability of a POP frequency standard operating with optical detection. A shot-noise limited frequency stability (Allan deviation) of ${\ensuremath{\sigma}}_{y}(\ensuremath{\tau})\ensuremath{\approx}3\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}14}{\ensuremath{\tau}}^{\ensuremath{-}1∕2}$ is foreseen. This value can be degraded by microwave phase noise and laser fluctuations so that the overall predicted clock stability is ${\ensuremath{\sigma}}_{y}(\ensuremath{\tau})\ensuremath{\approx}1.5\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}13}{\ensuremath{\tau}}^{\ensuremath{-}1∕2}$.

Physical Review A•Jan 6, 2009•50 citations

The pulsed optically pumped Rb frequency standards in National Time Service Center

Du Zhi-jing, Shougang Zhang, Jie Liu +3 more

In this paper we report a laboratory prototype of pulsed optically pumped (POP) rubidium frequency standard. In POP operation the pumping, interrogation, and detection phases are separated in time, avoiding the coupling between microwave and optical coherence. The POP87Rb vapor-cell frequency standard was studied experimentally based on the detection of free induction microwave signal or optical absorption signal. Ramsey fringes were obtained based on87Rb in buffer gas, with FWHM of 65Hz and 150Hz for microwave and optical central Ramsey fringes respectively. The atomic quality factor was on the order of 108. With microwave detection, the achieved frequency stability was 1.2×10-12τ-1/2(τ=1~100s).

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•May 1, 2012•2 citations

Demonstration of a high-performance pulsed optically pumped Rb clock based on a compact magnetron-type microwave cavity

Seung Won Kang, Mohammadreza Gharavipour, C. Affolderbach +2 more

We demonstrate a high-performance pulsed optically pumped (POP) Rb vapor-cell clock based on a magnetron-type microwave cavity of only 44 cm3 external volume. Using optical detection, an unprecedented 35% contrast of the Ramsey signal has been obtained. Both the signal-to-noise ratio (of 30 000) and the estimated shot-noise limit of 1.7 × 10−14 τ−1/2 are at the same level as those found with a bigger cylindrical TE011 cavity (100 cm3 inner volume) and are sufficient for achieving excellent clock stability. Rabi oscillations are measured and indicate a sufficiently uniform microwave magnetic field distribution inside the cavity. The instability sources for the POP clock's performance are analyzed. A short-term stability of 2.1 × 10−13 τ−1/2 is demonstrated which is consistent with the noise budget.

Journal of Applied Physics•Mar 12, 2015•63 citations

Integrated pulsed optically pumped Rb atomic clock with frequency stability of 10 − 15

Qiang Hao, Shaojie Yang, Jun Ruan +2 more

Pulsed optically pumped (POP) Rb atomic clock is considered to be a powerful technique for the Rb atomic clock due to the capability of light-shift mitigation and atomic spectroscopy narrowing. Relevant investigations are conducted over two decades, however, no integrated prototype of such a kind of clock has been reported yet. Here, we present an integrated prototype of the POP Rb atomic clock and quantitatively characterize its physical properties. The atomic clock shows a short-term fractional frequency stability of $2.6\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}13}/\sqrt{\ensuremath{\tau}}$ (where $\ensuremath{\tau}$ is the averaging time), and comes to $2.3\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}15}$ with 40 000 s averaging (drift removed) under atmospheric conditions. Physical effects contributing to the long-term frequency stability are carefully analyzed and cavity-pulling shift is identified as the leading limit. The techniques presented here enable realizing a low ${10}^{\ensuremath{-}15}$ level vapor-cell atomic clock under atmospheric conditions, which could benefit a wide range of terrestrial applications, such as quantum communication, decimeter-level terrestrial positioning.

Physical Review Applied•Feb 1, 2024•14 citations
We present theoretical and experimental studies concerning the realization of a rubidium vapor cell frequency standard based on the pulsed optical pumping (POP) technique. This technique is extremely powerful since it avoids in principle the light shift effect and the noise conversions from the laser to the clock signal. The detection of the clock transition in the microwave domain (the so called POP maser) has been extensively investigated at INRIM and a frequency stability of 1.1 × 10-12τ-1/2 has been measured until integration times of 105 s, reaching the level of 5 × 10-15 (drift removed). The optical detection is still under evaluation but this technique may lead in effect to some advantages with respect to the microwave detection, such as a lower or negligible cavity pulling, a lower operation temperature (which implies a lower spin exchange contribution) and a higher signal-to-noise ratio. All these features may lead to a better frequency stability performance than that previously reached. Read More: http://www.worldscientific.com/doi/abs/10.1142/9789812838223_0040
The pulsed optically pumped(POP) 87Rb vapor-cell frequency standard was studied based on the detection of free induction microwave signal or optical absorption signal.In POP operation the pumping,interrogation,and detection phases are separated in time,avoiding the coupling between microwave and optical coherence.The theoretical results show that an oscillation period doubled with respect to the classical Ramsey method which leads to a doubled atomic quality factor Q,and the reduction of optical shift and cavity pulling shift will be obtained,when the atoms are submitted to π/2 Ramsey microwave pulse.In experiment Ramsey fringes were obtained with a clock prototype based on 87Rb in buffer gas,with bandwidth of 65 Hz and 150 Hz for microwave and optical signal respectively.The frequency stability achieved was 1.2×10-12 for measurement times up to 100 s.
In this paper we report the results we obtained with a prototype of pulsed optically pumped (POP) Rb clock. In terms of frequency stability, an Allan deviation σy(τ)=1.7 ×10-13τ-1/2has been measured, where τ is the integration time. In addition, the long term frequency drift results below 10-14/day. In the paper we also describe a technique to stabilize the amplitude of the microwave signal using the atoms themselves as discriminator. Moreover, an anomalously large temperature sensitivity of the clock frequency and a technique to keep it under control are also reported. Finally, we describe some non linear effects that modify the shape of the clock signal represented by the Ramsey central fringe.
We present a multilevel theoretical approach to describe the behavior of a pulsed optically pumped (POP) 87Rb^{87}\mathrm{Rb}87Rb frequency standard based on a microwave cavity-vapor cell arrangement. The full Zeeman manifold of the ground-state hyperfine levels is then considered, and the dynamics induced among them by relaxation processes (buffer gas, spin exchange, and cell-walls collisions) is taken into account. The model includes as well the absorption of the pumping laser along the cell and the cavity feedback on the atoms; the effects related to a nonuniform excitation of the atomic sample are also discussed. Theoretical predictions are proven with a laboratory prototype of POP passive maser in which the clock transition is excited by means of the Ramsey technique. The agreement between theory and experiment is very satisfactory from both a quantitative and qualitative point of view, in terms of the shape of the Ramsey fringes, microwave power delivered by the atoms, and short-term frequency stability. In particular, a frequency stability of $1.2\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}12}$ at one second has been measured, in very good agreement with the expected value. On this basis, the model has been extended to predict the short-term frequency stability of a POP frequency standard operating with optical detection. A shot-noise limited frequency stability (Allan deviation) of ${\ensuremath{\sigma}}_{y}(\ensuremath{\tau})\ensuremath{\approx}3\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}14}{\ensuremath{\tau}}^{\ensuremath{-}1∕2}$ is foreseen. This value can be degraded by microwave phase noise and laser fluctuations so that the overall predicted clock stability is ${\ensuremath{\sigma}}_{y}(\ensuremath{\tau})\ensuremath{\approx}1.5\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}13}{\ensuremath{\tau}}^{\ensuremath{-}1∕2}$.
In this paper we report a laboratory prototype of pulsed optically pumped (POP) rubidium frequency standard. In POP operation the pumping, interrogation, and detection phases are separated in time, avoiding the coupling between microwave and optical coherence. The POP87Rb vapor-cell frequency standard was studied experimentally based on the detection of free induction microwave signal or optical absorption signal. Ramsey fringes were obtained based on87Rb in buffer gas, with FWHM of 65Hz and 150Hz for microwave and optical central Ramsey fringes respectively. The atomic quality factor was on the order of 108. With microwave detection, the achieved frequency stability was 1.2×10-12τ-1/2(τ=1~100s).
We demonstrate a high-performance pulsed optically pumped (POP) Rb vapor-cell clock based on a magnetron-type microwave cavity of only 44 cm3 external volume. Using optical detection, an unprecedented 35% contrast of the Ramsey signal has been obtained. Both the signal-to-noise ratio (of 30 000) and the estimated shot-noise limit of 1.7 × 10−14 τ−1/2 are at the same level as those found with a bigger cylindrical TE011 cavity (100 cm3 inner volume) and are sufficient for achieving excellent clock stability. Rabi oscillations are measured and indicate a sufficiently uniform microwave magnetic field distribution inside the cavity. The instability sources for the POP clock's performance are analyzed. A short-term stability of 2.1 × 10−13 τ−1/2 is demonstrated which is consistent with the noise budget.
Pulsed optically pumped (POP) Rb atomic clock is considered to be a powerful technique for the Rb atomic clock due to the capability of light-shift mitigation and atomic spectroscopy narrowing. Relevant investigations are conducted over two decades, however, no integrated prototype of such a kind of clock has been reported yet. Here, we present an integrated prototype of the POP Rb atomic clock and quantitatively characterize its physical properties. The atomic clock shows a short-term fractional frequency stability of $2.6\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}13}/\sqrt{\ensuremath{\tau}}$ (where $\ensuremath{\tau}$ is the averaging time), and comes to $2.3\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}15}$ with 40 000 s averaging (drift removed) under atmospheric conditions. Physical effects contributing to the long-term frequency stability are carefully analyzed and cavity-pulling shift is identified as the leading limit. The techniques presented here enable realizing a low ${10}^{\ensuremath{-}15}$ level vapor-cell atomic clock under atmospheric conditions, which could benefit a wide range of terrestrial applications, such as quantum communication, decimeter-level terrestrial positioning.