Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Journal of Applied Physics

Demonstration of a high-performance pulsed optically pumped Rb clock based on a compact magnetron-type microwave cavity

Seung Won Kang, Mohammadreza Gharavipour, C. Affolderbach, Florian Gruet, G. Mileti

Published Mar 12, 2015• 63 citations
Publisher

Abstract

We demonstrate a high-performance pulsed optically pumped (POP) Rb vapor-cell clock based on a magnetron-type microwave cavity of only 44 cm3 external volume. Using optical detection, an unprecedented 35% contrast of the Ramsey signal has been obtained. Both the signal-to-noise ratio (of 30 000) and the estimated shot-noise limit of 1.7 × 10−14 τ−1/2 are at the same level as those found with a bigger cylindrical TE011 cavity (100 cm3 inner volume) and are sufficient for achieving excellent clock stability. Rabi oscillations are measured and indicate a sufficiently uniform microwave magnetic field distribution inside the cavity. The instability sources for the POP clock's performance are analyzed. A short-term stability of 2.1 × 10−13 τ−1/2 is demonstrated which is consistent with the noise budget.

DOI
10.1063/1.4914493

Related papers

Pulsed optical pumping in a Rb vapor cell using a compact magnetron-type microwave cavity

Songbai Kang, C. Affolderbach, Florian Gruet +3 more

A compact magnetron-type microwave cavity has previously been developed for a high performance Rb atomic clock based on conventional continuous-wave double-resonance (DR) interrogation. This magnetron-type cavity shows a homogenous microwave field distribution while having a cavity volume of only 35 cm3. So it is interesting for realizing a high performance Rb cell clock based on pulsed optical pumping (POP) technique with a reduced physics package size. In this proceeding we report on the evaluation of pulsed optical pumping with our magnetron-type cavity. Using the pulsed technique and optical detection, high-contrast Ramsey fringes were observed. The central fringe of the Ramsey signal has a linewidth of 160 Hz and contrast of 35%. Under these conditions, the shot-noise limit is estimated at a level around 2×10-14τ-1/2which shows the great potential of a POP clock based on the compact magnetron-type cavity. The Rabi oscillation result also indicates an acceptable uniform field distribution inside the cavity for a high-performance POP clock. Some optimizations of pumping and detection power for improving the contrast are also presented.

European Frequency and Time Forum•Jun 1, 2014•6 citations

Microwave Pulse-Coherent Technique-Based Clock With a Novel Magnetron-Type Cavity

Qiang Hao, Wenxiang Xue, Wenbing Li +5 more

We report a high-performance pulsed optically pumped (POP) Rb clock based on a novel magnetron-type microwave cavity. The cavity has a volume of 30 mL, enabling a highly homogenous microwave field distribution. With the laser frequency tuning to the ground-state hyperfine level F = 2 of the D2line, we observe a Ramsey fringe contrast of 52% in terms of optical absorption detection. The resultant shot noise limit is estimated to be 1.6 × 10-14τ-1/2. The clock frequency stability is measured as 2.3 × 10-13τ-1/2(1-100 s), which is limited by the relative intensity noise of the light.

IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control•Nov 26, 2019•16 citations

μ POP Clock: A Microcell Atomic Clock Based on a Double-Resonance Ramsey Scheme

Etienne Batori, C. Affolderbach, Matthieu Pellaton +5 more

We demonstrate and study a microcell microwave atomic clock based on optical-microwave double resonance (DR) interrogation operated in a pulsed Ramsey scheme, called the \ensuremath{\mu}POP clock, based on a microfabricated Rb vapor cell and a micro-loop-gap microwave resonator. For the mm-scale dimensions of this cell, the population and coherence relaxation rates of the Rb clock transition are on the order of 4--5 kHz, which puts constraints on the useful Ramsey times and overall pulse sequence in view of optimized clock performance. Our proof-of-principle demonstration of the \ensuremath{\mu}POP clock shows that the pulsed DR approach is nevertheless feasible and results in a short-term clock stability of 1 \ifmmode\times\else\texttimes\fi{} ${10}^{\ensuremath{-}11}$ \ensuremath{\tau}${}^{\ensuremath{-}1/2}$ and reaching the \ensuremath{\le}2 \ifmmode\times\else\texttimes\fi{} ${10}^{\ensuremath{-}12}$ level at timescales of 1000 s to one day. The short-term instability budget established for the \ensuremath{\mu}POP clock shows that the main limitation to the short-term stability arises from the detection noise. Thanks to the pulsed Ramsey scheme, light-shift effects are strongly reduced in the \ensuremath{\mu}POP clock, which opens perspectives for further improvements of long-term clock stability, in view of future generations of miniature vapor-cell clocks with enhanced performances based on the DR scheme.

Physical Review Applied•Nov 14, 2022•30 citations

Pulsed optically pumped Rb clock: A high stability vapor cell frequency standard

Filippo Levi, Claudio Eligio Calosso, A. Godone +1 more

In this paper we report the results we obtained with a prototype of pulsed optically pumped (POP) Rb clock. In terms of frequency stability, an Allan deviation σy(τ)=1.7 ×10-13τ-1/2has been measured, where τ is the integration time. In addition, the long term frequency drift results below 10-14/day. In the paper we also describe a technique to stabilize the amplitude of the microwave signal using the atoms themselves as discriminator. Moreover, an anomalously large temperature sensitivity of the clock frequency and a technique to keep it under control are also reported. Finally, we describe some non linear effects that modify the shape of the clock signal represented by the Ramsey central fringe.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•Jul 1, 2013•1 citation

High performance vapour-cell frequency standards

Mohammadreza Gharavipour, C. Affolderbach, Songbai Kang +4 more

We report our investigations on a compact high-performance rubidium (Rb) vapourcell clock based on microwave-optical double-resonance (DR).These studies are done in both DR continuous-wave (CW) and Ramsey schemes using the same Physics Package (PP), with the same Rb vapour cell and a magnetron-type cavity with only 45 cm 3 external volume.In the CW-DR scheme, we demonstrate a DR signal with a contrast of 26% and a linewidth of 334 Hz; in Ramsey-DR mode Ramsey signals with higher contrast up to 35% and a linewidth of 160 Hz have been demonstrated.Short-term stabilities of 1.4×10 -13 τ -1/2 and 2.4×10 -13 τ -1/2 are measured for CW-DR and Ramsey-DR schemes, respectively.In the Ramsey-DR operation, thanks to the separation of light and microwave interactions in time, the light-shift effect has been suppressed which allows improving the long-term clock stability as compared to CW-DR operation.Implementations in miniature atomic clocks are considered. IntroductionSince the first invention of lamp-pumped rubidium (Rb) clocks in the 1960's [1,2], the demand for a stable, reliable, and compact Rb frequency standard with low power consumption has been growing, for various applications fields such as industry, telecommunication, navigation, space applications (e.g.GPS [3], GALILEO [4] and COMPASS [5]).Recently, thanks to the semiconductor laser technology, laser-pumped Rb clocks have been considered in several studies, for their better optical pumping efficiency results in short-term frequency stabilities at least one order of magnitude better than their lamp-pumped counterparts [6][7][8][9].This opened up also several new schemes for vapour-cell atomic clocks, such as the continuous-wave (CW) Rb clock [9], coherent population trapping (CPT) Cs clock [10] and pulsed optical pumping (POP) Rb clock [11].In this paper we report our studies on high-performance Rb frequency standards based on the laser-microwave double-resonance (DR) scheme, using both CW and Ramsey interrogation.Both CW-DR and Ramsey-DR schemes require two resonant electromagnetic fields of light and microwave.In the case of CW-DR, the laser optically pumps the vapour of the Rb atoms by creating a polarization of the atomic ground-state; simultaneously the microwave field, generated from a quartz oscillator and is near-resonant with the 87 Rb hyperfine clock transition (energy levels 5 2 S 1/2 │F g =1, m F =0˃ ↔│F g =2, m F =0˃), is applied.The opacity of the Rb vapour to the transmitted light signal as a function of microwave frequency is a measure of the atomic ground state polarization known as CW-DR signal [9].In CW-DR, the steps of optical pumping, microwave interrogation and optical detection are applied simultaneously (figure 1(b)).In the case of Ramsey-DR, these three sequences are separated in time, see figure 1(c): first, during optical pumping a strong laser pulse creates a significant atom population imbalance between

Journal of Physics Conference Series•Jun 1, 2016•20 citations

THE PULSED OPTICALLY PUMPED CLOCK: MICROWAVE AND OPTICAL DETECTION

Salvatore Micalizio, Aldo Godone, Filippo Levi +1 more

We present theoretical and experimental studies concerning the realization of a rubidium vapor cell frequency standard based on the pulsed optical pumping (POP) technique. This technique is extremely powerful since it avoids in principle the light shift effect and the noise conversions from the laser to the clock signal. The detection of the clock transition in the microwave domain (the so called POP maser) has been extensively investigated at INRIM and a frequency stability of 1.1 × 10-12τ-1/2 has been measured until integration times of 105 s, reaching the level of 5 × 10-15 (drift removed). The optical detection is still under evaluation but this technique may lead in effect to some advantages with respect to the microwave detection, such as a lower or negligible cavity pulling, a lower operation temperature (which implies a lower spin exchange contribution) and a higher signal-to-noise ratio. All these features may lead to a better frequency stability performance than that previously reached. Read More: http://www.worldscientific.com/doi/abs/10.1142/9789812838223_0040

Symposium on Frequency Standards and Metrology•May 1, 2009•0 citations
We demonstrate a high-performance pulsed optically pumped (POP) Rb vapor-cell clock based on a magnetron-type microwave cavity of only 44 cm3 external volume. Using optical detection, an unprecedented 35% contrast of the Ramsey signal has been obtained. Both the signal-to-noise ratio (of 30 000) and the estimated shot-noise limit of 1.7 × 10−14 τ−1/2 are at the same level as those found with a bigger cylindrical TE011 cavity (100 cm3 inner volume) and are sufficient for achieving excellent clock stability. Rabi oscillations are measured and indicate a sufficiently uniform microwave magnetic field distribution inside the cavity. The instability sources for the POP clock's performance are analyzed. A short-term stability of 2.1 × 10−13 τ−1/2 is demonstrated which is consistent with the noise budget.
A compact magnetron-type microwave cavity has previously been developed for a high performance Rb atomic clock based on conventional continuous-wave double-resonance (DR) interrogation. This magnetron-type cavity shows a homogenous microwave field distribution while having a cavity volume of only 35 cm3. So it is interesting for realizing a high performance Rb cell clock based on pulsed optical pumping (POP) technique with a reduced physics package size. In this proceeding we report on the evaluation of pulsed optical pumping with our magnetron-type cavity. Using the pulsed technique and optical detection, high-contrast Ramsey fringes were observed. The central fringe of the Ramsey signal has a linewidth of 160 Hz and contrast of 35%. Under these conditions, the shot-noise limit is estimated at a level around 2×10-14τ-1/2which shows the great potential of a POP clock based on the compact magnetron-type cavity. The Rabi oscillation result also indicates an acceptable uniform field distribution inside the cavity for a high-performance POP clock. Some optimizations of pumping and detection power for improving the contrast are also presented.
We report a high-performance pulsed optically pumped (POP) Rb clock based on a novel magnetron-type microwave cavity. The cavity has a volume of 30 mL, enabling a highly homogenous microwave field distribution. With the laser frequency tuning to the ground-state hyperfine level F = 2 of the D2line, we observe a Ramsey fringe contrast of 52% in terms of optical absorption detection. The resultant shot noise limit is estimated to be 1.6 × 10-14τ-1/2. The clock frequency stability is measured as 2.3 × 10-13τ-1/2(1-100 s), which is limited by the relative intensity noise of the light.
We demonstrate and study a microcell microwave atomic clock based on optical-microwave double resonance (DR) interrogation operated in a pulsed Ramsey scheme, called the \ensuremath{\mu}POP clock, based on a microfabricated Rb vapor cell and a micro-loop-gap microwave resonator. For the mm-scale dimensions of this cell, the population and coherence relaxation rates of the Rb clock transition are on the order of 4--5 kHz, which puts constraints on the useful Ramsey times and overall pulse sequence in view of optimized clock performance. Our proof-of-principle demonstration of the \ensuremath{\mu}POP clock shows that the pulsed DR approach is nevertheless feasible and results in a short-term clock stability of 1 \ifmmode\times\else\texttimes\fi{} ${10}^{\ensuremath{-}11}$ \ensuremath{\tau}${}^{\ensuremath{-}1/2}$ and reaching the \ensuremath{\le}2 \ifmmode\times\else\texttimes\fi{} ${10}^{\ensuremath{-}12}$ level at timescales of 1000 s to one day. The short-term instability budget established for the \ensuremath{\mu}POP clock shows that the main limitation to the short-term stability arises from the detection noise. Thanks to the pulsed Ramsey scheme, light-shift effects are strongly reduced in the \ensuremath{\mu}POP clock, which opens perspectives for further improvements of long-term clock stability, in view of future generations of miniature vapor-cell clocks with enhanced performances based on the DR scheme.
In this paper we report the results we obtained with a prototype of pulsed optically pumped (POP) Rb clock. In terms of frequency stability, an Allan deviation σy(τ)=1.7 ×10-13τ-1/2has been measured, where τ is the integration time. In addition, the long term frequency drift results below 10-14/day. In the paper we also describe a technique to stabilize the amplitude of the microwave signal using the atoms themselves as discriminator. Moreover, an anomalously large temperature sensitivity of the clock frequency and a technique to keep it under control are also reported. Finally, we describe some non linear effects that modify the shape of the clock signal represented by the Ramsey central fringe.
We report our investigations on a compact high-performance rubidium (Rb) vapourcell clock based on microwave-optical double-resonance (DR).These studies are done in both DR continuous-wave (CW) and Ramsey schemes using the same Physics Package (PP), with the same Rb vapour cell and a magnetron-type cavity with only 45 cm 3 external volume.In the CW-DR scheme, we demonstrate a DR signal with a contrast of 26% and a linewidth of 334 Hz; in Ramsey-DR mode Ramsey signals with higher contrast up to 35% and a linewidth of 160 Hz have been demonstrated.Short-term stabilities of 1.4×10 -13 τ -1/2 and 2.4×10 -13 τ -1/2 are measured for CW-DR and Ramsey-DR schemes, respectively.In the Ramsey-DR operation, thanks to the separation of light and microwave interactions in time, the light-shift effect has been suppressed which allows improving the long-term clock stability as compared to CW-DR operation.Implementations in miniature atomic clocks are considered. IntroductionSince the first invention of lamp-pumped rubidium (Rb) clocks in the 1960's [1,2], the demand for a stable, reliable, and compact Rb frequency standard with low power consumption has been growing, for various applications fields such as industry, telecommunication, navigation, space applications (e.g.GPS [3], GALILEO [4] and COMPASS [5]).Recently, thanks to the semiconductor laser technology, laser-pumped Rb clocks have been considered in several studies, for their better optical pumping efficiency results in short-term frequency stabilities at least one order of magnitude better than their lamp-pumped counterparts [6][7][8][9].This opened up also several new schemes for vapour-cell atomic clocks, such as the continuous-wave (CW) Rb clock [9], coherent population trapping (CPT) Cs clock [10] and pulsed optical pumping (POP) Rb clock [11].In this paper we report our studies on high-performance Rb frequency standards based on the laser-microwave double-resonance (DR) scheme, using both CW and Ramsey interrogation.Both CW-DR and Ramsey-DR schemes require two resonant electromagnetic fields of light and microwave.In the case of CW-DR, the laser optically pumps the vapour of the Rb atoms by creating a polarization of the atomic ground-state; simultaneously the microwave field, generated from a quartz oscillator and is near-resonant with the 87 Rb hyperfine clock transition (energy levels 5 2 S 1/2 │F g =1, m F =0˃ ↔│F g =2, m F =0˃), is applied.The opacity of the Rb vapour to the transmitted light signal as a function of microwave frequency is a measure of the atomic ground state polarization known as CW-DR signal [9].In CW-DR, the steps of optical pumping, microwave interrogation and optical detection are applied simultaneously (figure 1(b)).In the case of Ramsey-DR, these three sequences are separated in time, see figure 1(c): first, during optical pumping a strong laser pulse creates a significant atom population imbalance between
We present theoretical and experimental studies concerning the realization of a rubidium vapor cell frequency standard based on the pulsed optical pumping (POP) technique. This technique is extremely powerful since it avoids in principle the light shift effect and the noise conversions from the laser to the clock signal. The detection of the clock transition in the microwave domain (the so called POP maser) has been extensively investigated at INRIM and a frequency stability of 1.1 × 10-12τ-1/2 has been measured until integration times of 105 s, reaching the level of 5 × 10-15 (drift removed). The optical detection is still under evaluation but this technique may lead in effect to some advantages with respect to the microwave detection, such as a lower or negligible cavity pulling, a lower operation temperature (which implies a lower spin exchange contribution) and a higher signal-to-noise ratio. All these features may lead to a better frequency stability performance than that previously reached. Read More: http://www.worldscientific.com/doi/abs/10.1142/9789812838223_0040