Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)

Pulsed optically pumped Rb clock: A high stability vapor cell frequency standard

Filippo Levi, Claudio Eligio Calosso, A. Godone, Salvatore Micalizio

Published Jul 1, 2013• 3 citations
Publisher

Abstract

In this paper we report the results we obtained with a prototype of pulsed optically pumped (POP) Rb clock. In terms of frequency stability, an Allan deviation σy(τ)=1.7 ×10-13τ-1/2has been measured, where τ is the integration time. In addition, the long term frequency drift results below 10-14/day. In the paper we also describe a technique to stabilize the amplitude of the microwave signal using the atoms themselves as discriminator. Moreover, an anomalously large temperature sensitivity of the clock frequency and a technique to keep it under control are also reported. Finally, we describe some non linear effects that modify the shape of the clock signal represented by the Ramsey central fringe.

DOI
10.1109/eftf-ifc.2013.6702182

Related papers

The pulsed optically pumped Rb frequency standards in National Time Service Center

Du Zhi-jing, Shougang Zhang, Jie Liu +3 more

In this paper we report a laboratory prototype of pulsed optically pumped (POP) rubidium frequency standard. In POP operation the pumping, interrogation, and detection phases are separated in time, avoiding the coupling between microwave and optical coherence. The POP87Rb vapor-cell frequency standard was studied experimentally based on the detection of free induction microwave signal or optical absorption signal. Ramsey fringes were obtained based on87Rb in buffer gas, with FWHM of 65Hz and 150Hz for microwave and optical central Ramsey fringes respectively. The atomic quality factor was on the order of 108. With microwave detection, the achieved frequency stability was 1.2×10-12τ-1/2(τ=1~100s).

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•May 1, 2012•3 citations

Study of Pulsed Optically Pumped Rb Frequency Standard

Shougang Zhang

The pulsed optically pumped(POP) 87Rb vapor-cell frequency standard was studied based on the detection of free induction microwave signal or optical absorption signal.In POP operation the pumping,interrogation,and detection phases are separated in time,avoiding the coupling between microwave and optical coherence.The theoretical results show that an oscillation period doubled with respect to the classical Ramsey method which leads to a doubled atomic quality factor Q,and the reduction of optical shift and cavity pulling shift will be obtained,when the atoms are submitted to π/2 Ramsey microwave pulse.In experiment Ramsey fringes were obtained with a clock prototype based on 87Rb in buffer gas,with bandwidth of 65 Hz and 150 Hz for microwave and optical signal respectively.The frequency stability achieved was 1.2×10-12 for measurement times up to 100 s.

Wuhan Daxue xuebao. Xinxi kexue ban•Jan 1, 2011•0 citations

Integrated pulsed optically pumped Rb atomic clock with frequency stability of 10 − 15

Qiang Hao, Shaojie Yang, Jun Ruan +2 more

Pulsed optically pumped (POP) Rb atomic clock is considered to be a powerful technique for the Rb atomic clock due to the capability of light-shift mitigation and atomic spectroscopy narrowing. Relevant investigations are conducted over two decades, however, no integrated prototype of such a kind of clock has been reported yet. Here, we present an integrated prototype of the POP Rb atomic clock and quantitatively characterize its physical properties. The atomic clock shows a short-term fractional frequency stability of $2.6\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}13}/\sqrt{\ensuremath{\tau}}$ (where $\ensuremath{\tau}$ is the averaging time), and comes to $2.3\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}15}$ with 40 000 s averaging (drift removed) under atmospheric conditions. Physical effects contributing to the long-term frequency stability are carefully analyzed and cavity-pulling shift is identified as the leading limit. The techniques presented here enable realizing a low ${10}^{\ensuremath{-}15}$ level vapor-cell atomic clock under atmospheric conditions, which could benefit a wide range of terrestrial applications, such as quantum communication, decimeter-level terrestrial positioning.

Physical Review Applied•Feb 1, 2024•16 citations

Pulsed optically pumped rubidium clock with high frequency-stability performance

Salvatore Micalizio, A. Godone, Claudio Eligio Calosso +3 more

In this paper, we present the performance of a vapor-cell rubidium frequency standard working in the pulsed regime, in which the clock signal is represented by a Ramsey pattern observed on an optically detected laser absorption signal. The main experimental results agree with previously reported theoretical predictions. In particular, we measured a relative frequency stability of σy(τ) - 1.6 × 10(-13)τ-1/2 for integration times, τ, up to 200 s, which represents a record in short-term stability for a vapor-cell clock. We also discuss the most important physical phenomena that contribute to this result.

IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control•Mar 1, 2012•36 citations

Frequency stability of a pulsed optically pumped atomic clock with narrow Ramsey linewidth

Haixiao Lin, Jianliao Deng, Jinda Lin +2 more

In general, the linewidth of the Ramsey central fringe (RCF) is equal to 1/(2T), where T is the Ramsey free-evolution time. We demonstrate that the RCF linewidth of a pulsed optically pumped (POP) atomic clock with orthogonal polarization detection based on the magneto-optical rotation effect can be narrowed down to 1/(4T). The Allan deviation of the POP atomic clock decreases from 2.4×10−13τ−1/2 to 1.4×10−13τ−1/2. This corresponds to an improvement in the frequency stability by about 60%. We also estimate the main noise sources that limit the short-term frequency stability of the POP atomic clock.

Applied Optics•Apr 13, 2018•14 citations

THE PULSED OPTICALLY PUMPED CLOCK: MICROWAVE AND OPTICAL DETECTION

Salvatore Micalizio, Aldo Godone, Filippo Levi +1 more

We present theoretical and experimental studies concerning the realization of a rubidium vapor cell frequency standard based on the pulsed optical pumping (POP) technique. This technique is extremely powerful since it avoids in principle the light shift effect and the noise conversions from the laser to the clock signal. The detection of the clock transition in the microwave domain (the so called POP maser) has been extensively investigated at INRIM and a frequency stability of 1.1 × 10 -12 τ -1/2 has been measured until integration times of 10 5 s, reaching the level of 5 × 10 -15 (drift removed). The optical detection is still under evaluation but this technique may lead in effect to some advantages with respect to the microwave detection, such as a lower or negligible cavity pulling, a lower operation temperature (which implies a lower spin exchange contribution) and a higher signal-to-noise ratio. All these features may lead to a better frequency stability performance than that previously reached.

Symposium on Frequency Standards and Metrology•May 1, 2009•0 citations
In this paper we report the results we obtained with a prototype of pulsed optically pumped (POP) Rb clock. In terms of frequency stability, an Allan deviation σy(τ)=1.7 ×10-13τ-1/2has been measured, where τ is the integration time. In addition, the long term frequency drift results below 10-14/day. In the paper we also describe a technique to stabilize the amplitude of the microwave signal using the atoms themselves as discriminator. Moreover, an anomalously large temperature sensitivity of the clock frequency and a technique to keep it under control are also reported. Finally, we describe some non linear effects that modify the shape of the clock signal represented by the Ramsey central fringe.
In this paper we report a laboratory prototype of pulsed optically pumped (POP) rubidium frequency standard. In POP operation the pumping, interrogation, and detection phases are separated in time, avoiding the coupling between microwave and optical coherence. The POP87Rb vapor-cell frequency standard was studied experimentally based on the detection of free induction microwave signal or optical absorption signal. Ramsey fringes were obtained based on87Rb in buffer gas, with FWHM of 65Hz and 150Hz for microwave and optical central Ramsey fringes respectively. The atomic quality factor was on the order of 108. With microwave detection, the achieved frequency stability was 1.2×10-12τ-1/2(τ=1~100s).
The pulsed optically pumped(POP) 87Rb vapor-cell frequency standard was studied based on the detection of free induction microwave signal or optical absorption signal.In POP operation the pumping,interrogation,and detection phases are separated in time,avoiding the coupling between microwave and optical coherence.The theoretical results show that an oscillation period doubled with respect to the classical Ramsey method which leads to a doubled atomic quality factor Q,and the reduction of optical shift and cavity pulling shift will be obtained,when the atoms are submitted to π/2 Ramsey microwave pulse.In experiment Ramsey fringes were obtained with a clock prototype based on 87Rb in buffer gas,with bandwidth of 65 Hz and 150 Hz for microwave and optical signal respectively.The frequency stability achieved was 1.2×10-12 for measurement times up to 100 s.
Pulsed optically pumped (POP) Rb atomic clock is considered to be a powerful technique for the Rb atomic clock due to the capability of light-shift mitigation and atomic spectroscopy narrowing. Relevant investigations are conducted over two decades, however, no integrated prototype of such a kind of clock has been reported yet. Here, we present an integrated prototype of the POP Rb atomic clock and quantitatively characterize its physical properties. The atomic clock shows a short-term fractional frequency stability of $2.6\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}13}/\sqrt{\ensuremath{\tau}}$ (where $\ensuremath{\tau}$ is the averaging time), and comes to $2.3\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}15}$ with 40 000 s averaging (drift removed) under atmospheric conditions. Physical effects contributing to the long-term frequency stability are carefully analyzed and cavity-pulling shift is identified as the leading limit. The techniques presented here enable realizing a low ${10}^{\ensuremath{-}15}$ level vapor-cell atomic clock under atmospheric conditions, which could benefit a wide range of terrestrial applications, such as quantum communication, decimeter-level terrestrial positioning.
In this paper, we present the performance of a vapor-cell rubidium frequency standard working in the pulsed regime, in which the clock signal is represented by a Ramsey pattern observed on an optically detected laser absorption signal. The main experimental results agree with previously reported theoretical predictions. In particular, we measured a relative frequency stability of σy(τ) - 1.6 × 10(-13)τ-1/2 for integration times, τ, up to 200 s, which represents a record in short-term stability for a vapor-cell clock. We also discuss the most important physical phenomena that contribute to this result.
In general, the linewidth of the Ramsey central fringe (RCF) is equal to 1/(2T), where T is the Ramsey free-evolution time. We demonstrate that the RCF linewidth of a pulsed optically pumped (POP) atomic clock with orthogonal polarization detection based on the magneto-optical rotation effect can be narrowed down to 1/(4T). The Allan deviation of the POP atomic clock decreases from 2.4×10−13τ−1/2 to 1.4×10−13τ−1/2. This corresponds to an improvement in the frequency stability by about 60%. We also estimate the main noise sources that limit the short-term frequency stability of the POP atomic clock.
We present theoretical and experimental studies concerning the realization of a rubidium vapor cell frequency standard based on the pulsed optical pumping (POP) technique. This technique is extremely powerful since it avoids in principle the light shift effect and the noise conversions from the laser to the clock signal. The detection of the clock transition in the microwave domain (the so called POP maser) has been extensively investigated at INRIM and a frequency stability of 1.1 × 10 -12 τ -1/2 has been measured until integration times of 10 5 s, reaching the level of 5 × 10 -15 (drift removed). The optical detection is still under evaluation but this technique may lead in effect to some advantages with respect to the microwave detection, such as a lower or negligible cavity pulling, a lower operation temperature (which implies a lower spin exchange contribution) and a higher signal-to-noise ratio. All these features may lead to a better frequency stability performance than that previously reached.