URSI Asia-Pacific Radio Science Conference

Recent Advances in High-Precision 40Ca+ Optical Clocks: Laboratory-Based and Transportable Systems Pushing the Limits of Timekeeping

Hua Guan

Published Jan 1, 2025• 0 citations
Publisher
DOI
10.46620/ursiaprasc25/owrz2596

Related papers

Optical Lattice Clocks for Precision Time and Frequency Metrology

Masao Takamoto, Hidetoshi Katori

Lecture notes in physics•Dec 29, 2015•4 citations

Design of a Board-Level Integrated Multi-Channel Radio Frequency Source for the Transportable 40Ca+ Ion Optical Clock

Bin Wang, Yuanhang Yang, Huaqing Zhang +5 more

As one of the most precise timekeeping instruments ever developed, the optical clock will be used as the measuring equipment for the next generation of second definition. The demand for the miniaturization of optical clocks is progressively urgent. In this paper, a multi-channel radio frequency (RF) module with a 20% volume of the commercial module is designed and implemented for the transportable 40Ca+ ion optical clock. Based on the double-crystal oscillator interlocking technique, a 1 GHz low-phase noise reference source is developed for direct digital synthesis. Through the simulation and optimization of the signal link design, the frequency range of the low phase-noise RF signal can reach 0–400 MHz with a 4 μHz resolution. Through two-stage power amplifying with different kinds of filters, it can achieve an output power of up to +33 dBm (2 W) at 100 MHz with a 25 dB phase noise lower than the commercial module at 1 Hz, and its third harmonic suppression ratio has been reduced by more than 20 dB at the frequency point of 300 MHz. This multi-channel RF module is used for the power stability and timing control test of a 729 nm clock laser to meet the requirements of the transportable 40Ca+ optical clock. Additionally, this module can also be applied to other quantum systems such as the quantum absolute gravimeter, quantum gyroscopes, and quantum computers.

Sensors•Feb 10, 2025•0 citations

Improving Optical Clocks

Science•Nov 18, 2004•0 citations

40Ca+ optical clocks in China

Hua Guan, Baolin Zhang, Huaqing Zhang +4 more

In this review, the improvements made in the past two decades for 40Ca+ optical clocks in China are presented. Uncertainty of below 1.3×10−17 was achieved by applying the “magic” RF trapping frequency and introducing a generalized Ramsey excitation scheme. The stability of 40Ca+ optical clocks has been improved to 2.5×10−15/τ with an uptime rate of 93.8% by implementing two ameliorated lock algorithms in the Ramsey excitation scheme. A long-term clock frequency comparison shows a clock stability of 6.3 × 10−18 in an averaging time of 524 000 s. A robust and transportable clock installed in an air-conditioned car trailer can achieve almost the same performance of laboratory clocks. A height difference between transportable and laboratory clocks was measured with an uncertainty of 0.33 m and the absolute frequency of 40Ca+ optical clock transitions was remeasured as 411 042 129 776 400.41(23) Hz, with a fractional uncertainty of 5.6×10−16 based on a Cs fountain clock in the National Institute of Metrology after the transportable clock was transported from Wuhan to Beijing. The author predicts that transportable single-ion optical clocks especially based on the 40Ca+ will make a significant contribution to the construction of a world-wide optical clock network and the redefinition of the unit of time in the future.

AVS Quantum Science•Oct 11, 2021•4 citations

40Ca+ optical frequency standards with high accuracy

Guan Hua, Yao Huang, Chengbin Li +1 more

With the development of the technologies in the lasers and the manipulation of cold atoms, the high precision optical frequency standards have been extensively studied and built in recent years. These high precision frequency standards may play an important role in establishing the new time reference, promoting the researches in the fundamental fields, fulfilling the national strategic needs, etc. In this paper, the research progress of high accuracy 40Ca+ optical frequency standard in Wuhan Institute of Physics and Mathematics (WIPM) of Chinese Academy of Sciences is presented. A new ULE super cavity is adopted for stabilizing the frequency of 729 nm clock laser, and the stability of the laser is improved now to 2×10-15 in a duration of 1-100 s. By controlling the external fields and other environmental influences, especially suppressing the micromotion effects of the trapped ion, the uncertainty of the optical frequency standard based on a single 40Ca+ is reduced to 5.5×10-17. The stability of 5×10-17 in a duration of 20000 s is achieved via the comparison between two 40Ca+ optical frequency standards. Several precision measurement experiments are performed, based on the high precision 40Ca+ optical frequency standard. The absolute value of the clock transition frequency of the 40Ca+ optical frequency standard is measured second time, using an optical comb referenced to a hydrogen maser which is calibrated via GPS referenced to UTC (NIM)) using the precise point positioning data-processing technique. The frequency offset of UTC (NIM) relative to the SI second can be evaluated through BIPM circular-T reports, and the newly measured value of m 4s 2S1/2-3m d 2D5/2 transition is adopted by CCTF-20, thus updating the recommended value of 40Ca+ optical clock transition. Besides the absolute frequency measurement, the magic wavelengths of 40Ca+ optical clock transition are measured precisely, and this work is a milestone for establishing all-optical trapped-ion clocks. The lifetime of the m 3 d 2D3/2 and m 3 d 2D5/2 state in 40Ca+ are precisely measured, too. The work mentioned above contributes to the researches of the precision measurements based on cold atomic systems.

Acta Physica Sinica•Jan 1, 2018•4 citations

Optical lattice clocks : Metrology and quantum technologies

Jérôme Lodewyck

•Nov 1, 2019•0 citations
As one of the most precise timekeeping instruments ever developed, the optical clock will be used as the measuring equipment for the next generation of second definition. The demand for the miniaturization of optical clocks is progressively urgent. In this paper, a multi-channel radio frequency (RF) module with a 20% volume of the commercial module is designed and implemented for the transportable 40Ca+ ion optical clock. Based on the double-crystal oscillator interlocking technique, a 1 GHz low-phase noise reference source is developed for direct digital synthesis. Through the simulation and optimization of the signal link design, the frequency range of the low phase-noise RF signal can reach 0–400 MHz with a 4 μHz resolution. Through two-stage power amplifying with different kinds of filters, it can achieve an output power of up to +33 dBm (2 W) at 100 MHz with a 25 dB phase noise lower than the commercial module at 1 Hz, and its third harmonic suppression ratio has been reduced by more than 20 dB at the frequency point of 300 MHz. This multi-channel RF module is used for the power stability and timing control test of a 729 nm clock laser to meet the requirements of the transportable 40Ca+ optical clock. Additionally, this module can also be applied to other quantum systems such as the quantum absolute gravimeter, quantum gyroscopes, and quantum computers.
In this review, the improvements made in the past two decades for 40Ca+ optical clocks in China are presented. Uncertainty of below 1.3×10−17 was achieved by applying the “magic” RF trapping frequency and introducing a generalized Ramsey excitation scheme. The stability of 40Ca+ optical clocks has been improved to 2.5×10−15/τ with an uptime rate of 93.8% by implementing two ameliorated lock algorithms in the Ramsey excitation scheme. A long-term clock frequency comparison shows a clock stability of 6.3 × 10−18 in an averaging time of 524 000 s. A robust and transportable clock installed in an air-conditioned car trailer can achieve almost the same performance of laboratory clocks. A height difference between transportable and laboratory clocks was measured with an uncertainty of 0.33 m and the absolute frequency of 40Ca+ optical clock transitions was remeasured as 411 042 129 776 400.41(23) Hz, with a fractional uncertainty of 5.6×10−16 based on a Cs fountain clock in the National Institute of Metrology after the transportable clock was transported from Wuhan to Beijing. The author predicts that transportable single-ion optical clocks especially based on the 40Ca+ will make a significant contribution to the construction of a world-wide optical clock network and the redefinition of the unit of time in the future.
With the development of the technologies in the lasers and the manipulation of cold atoms, the high precision optical frequency standards have been extensively studied and built in recent years. These high precision frequency standards may play an important role in establishing the new time reference, promoting the researches in the fundamental fields, fulfilling the national strategic needs, etc. In this paper, the research progress of high accuracy 40Ca+ optical frequency standard in Wuhan Institute of Physics and Mathematics (WIPM) of Chinese Academy of Sciences is presented. A new ULE super cavity is adopted for stabilizing the frequency of 729 nm clock laser, and the stability of the laser is improved now to 2×10-15 in a duration of 1-100 s. By controlling the external fields and other environmental influences, especially suppressing the micromotion effects of the trapped ion, the uncertainty of the optical frequency standard based on a single 40Ca+ is reduced to 5.5×10-17. The stability of 5×10-17 in a duration of 20000 s is achieved via the comparison between two 40Ca+ optical frequency standards. Several precision measurement experiments are performed, based on the high precision 40Ca+ optical frequency standard. The absolute value of the clock transition frequency of the 40Ca+ optical frequency standard is measured second time, using an optical comb referenced to a hydrogen maser which is calibrated via GPS referenced to UTC (NIM)) using the precise point positioning data-processing technique. The frequency offset of UTC (NIM) relative to the SI second can be evaluated through BIPM circular-T reports, and the newly measured value of m 4s 2S1/2-3m d 2D5/2 transition is adopted by CCTF-20, thus updating the recommended value of 40Ca+ optical clock transition. Besides the absolute frequency measurement, the magic wavelengths of 40Ca+ optical clock transition are measured precisely, and this work is a milestone for establishing all-optical trapped-ion clocks. The lifetime of the m 3 d 2D3/2 and m 3 d 2D5/2 state in 40Ca+ are precisely measured, too. The work mentioned above contributes to the researches of the precision measurements based on cold atomic systems.