Science

Improving Optical Clocks

Published Nov 18, 2004• 0 citations
Publisher
DOI
10.1126/science.306.5700.1255c

Related papers

An improved optical clock with ultracold calcium atoms

Tatiana Nazarova, C. Degenhardt, Christian Lisdat +3 more

Conference on Lasers and Electro-Optics•Jan 1, 2005•0 citations

Improvement of Stability of 40 Ca + Optical Clock with State Preparation

Mengyan Zeng, Yao Huang, Hongyong Shao +5 more

Stability is one of most important performances of an atomic clock. Here we describe our recent work on improving the stability of our 40 Ca + optical clock. State preparation is adopted to transfer the ion to the ground-state magnetic sublevel of the clock transition, after the quenching laser transfers the ion to the ground state at each cycle. Using this method, the stability for 40 Ca + optical clock is improved to about . Compared with in previous work, the averaging time is decreased to reach a given level of statistical uncertainty in a clock comparison .

Chinese Physics Letters•Jul 1, 2018•7 citations

Smarter optical clocks

Nature India•Dec 20, 2009•0 citations

A transportable 40 Ca + optical clock with 1.6 × 10 − 15 / τ frequency instability enabled by improved magnetic shielding and comb-based frequency stability transfer

Ruming Hu, Zixiao Ma, Baolin Zhang +12 more

Here, we develop a compact multilayer magnetic shield for a transportable optical clock, achieving shielding factors of up to 10 5 . To improve the frequency stability of the transportable optical clock, we improved the magnetic-field environment of a transportable 40 Ca + ion optical clock (TCIOC) using the newly developed magnetic shielding system and reduced the clock-laser frequency noise by transferring the stability of an ultrastable reference laser through an optical frequency comb. These improvements enabled the coherent interrogation time to be extended from 40 ms to 320 ms . A time-interleaved self-comparison yielded a measured short-term fractional frequency instability of 1.6 × 10 − 15 / τ , close to the estimated quantum projection noise-limited instability of 1.18 × 10 − 15 / τ . Meanwhile, the uncertainty contributions associated with the DC second-order Zeeman shift and the servo error were reduced to 1.1 × 10 − 21 and 4.5 × 10 − 19 . These results provide a practical basis for further improving the performance of transportable optical clocks.

New Journal of Physics•Sep 1, 2026•0 citations

Active Optical Clock

Jingbiao Chen

arXiv:physics/0512096•Chinese Science Bulletin•Dec 12, 2005•4 citations

Stability Improvement of an Aluminum Ion Optical Clock

B. Wang, Z. Y. Ma, Liren Pang +5 more

Based on the current initiative to redefine the SI “second”, the optical clock has been demonstrated by many laboratories as a favorable candidate due to its excellent performance indicators. We describe the evaluation of uncertainty and optimization of stability in an aluminum-ion optical clock system based on quantum logic spectroscopy. The uncertainty evaluation of the current optical clock system is$1.6\times 10^{-18}$. The frequency stability of a single system has been improved from 3.9$\times 10^{-15} / \sqrt{\tau}$to 2.6$\times 10^{-15} / \sqrt{\tau}$by using the servo-controlled self-comparison locking method.

European Frequency and Time Forum•Jun 25, 2024•0 citations
Stability is one of most important performances of an atomic clock. Here we describe our recent work on improving the stability of our 40 Ca + optical clock. State preparation is adopted to transfer the ion to the ground-state magnetic sublevel of the clock transition, after the quenching laser transfers the ion to the ground state at each cycle. Using this method, the stability for 40 Ca + optical clock is improved to about . Compared with in previous work, the averaging time is decreased to reach a given level of statistical uncertainty in a clock comparison .
Here, we develop a compact multilayer magnetic shield for a transportable optical clock, achieving shielding factors of up to 10 5 . To improve the frequency stability of the transportable optical clock, we improved the magnetic-field environment of a transportable 40 Ca + ion optical clock (TCIOC) using the newly developed magnetic shielding system and reduced the clock-laser frequency noise by transferring the stability of an ultrastable reference laser through an optical frequency comb. These improvements enabled the coherent interrogation time to be extended from 40 ms to 320 ms . A time-interleaved self-comparison yielded a measured short-term fractional frequency instability of 1.6 × 10 − 15 / τ , close to the estimated quantum projection noise-limited instability of 1.18 × 10 − 15 / τ . Meanwhile, the uncertainty contributions associated with the DC second-order Zeeman shift and the servo error were reduced to 1.1 × 10 − 21 and 4.5 × 10 − 19 . These results provide a practical basis for further improving the performance of transportable optical clocks.
Based on the current initiative to redefine the SI “second”, the optical clock has been demonstrated by many laboratories as a favorable candidate due to its excellent performance indicators. We describe the evaluation of uncertainty and optimization of stability in an aluminum-ion optical clock system based on quantum logic spectroscopy. The uncertainty evaluation of the current optical clock system is1.6×10−181.6\times 10^{-18}1.6×10−18. The frequency stability of a single system has been improved from 3.9×10−15/τ\times 10^{-15} / \sqrt{\tau}×10−15/τ​to 2.6×10−15/τ\times 10^{-15} / \sqrt{\tau}×10−15/τ​by using the servo-controlled self-comparison locking method.