Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Science

Improving Optical Clocks

Published Nov 18, 2004• 0 citations
Publisher
DOI
10.1126/science.306.5700.1255c

Related papers

Optical lattice clocks near the QPN limit: a tenfold improvement in optical clock stability

Travis Nicholson

Bulletin of the American Physical Society•Jun 7, 2013•0 citations

An improved optical clock with ultracold calcium atoms

Tatiana Nazarova, C. Degenhardt, Christian Lisdat +3 more

Conference on Lasers and Electro-Optics•Jan 1, 2005•0 citations

Improvement of Stability of 40 Ca + Optical Clock with State Preparation

Mengyan Zeng, Yao Huang, H. Shao +5 more

Stability is one of most important performances of an atomic clock. Here we describe our recent work on improving the stability of our 40 Ca + optical clock. State preparation is adopted to transfer the ion to the ground-state magnetic sublevel of the clock transition, after the quenching laser transfers the ion to the ground state at each cycle. Using this method, the stability for 40 Ca + optical clock is improved to about . Compared with in previous work, the averaging time is decreased to reach a given level of statistical uncertainty in a clock comparison .

Chinese Physics Letters•Jul 1, 2018•6 citations

Smarter optical clocks

Nature India•Dec 20, 2009•0 citations

Optical lattice clocks

S. Bize

•Oct 10, 2023•0 citations

A transportable 40 Ca + optical clock with 1.6 × 10 − 15 / τ frequency instability enabled by improved magnetic shielding and comb-based frequency stability transfer

Ruming Hu, Zixiao Ma, Baolin Zhang +12 more

Abstract Here, we develop a compact multilayer magnetic shield for a transportable optical clock, achieving shielding factors of up to 10 5 . To improve the frequency stability of the transportable optical clock, we improved the magnetic-field environment of a transportable 40 Ca + ion optical clock (TCIOC) using the newly developed magnetic shielding system and reduced the clock-laser frequency noise by transferring the stability of an ultrastable reference laser through an optical frequency comb. These improvements enabled the coherent interrogation time to be extended from 40 ms to 320 ms . A time-interleaved self-comparison yielded a measured short-term fractional frequency instability of 1.6 × 10 − 15 / τ , close to the estimated quantum projection noise-limited instability of 1.18 × 10 − 15 / τ . Meanwhile, the uncertainty contributions associated with the DC second-order Zeeman shift and the servo error were reduced to 1.1 × 10 − 21 and 4.5 × 10 − 19 . These results provide a practical basis for further improving the performance of transportable optical clocks.

New Journal of Physics•Aug 20, 2026•0 citations
Stability is one of most important performances of an atomic clock. Here we describe our recent work on improving the stability of our 40 Ca + optical clock. State preparation is adopted to transfer the ion to the ground-state magnetic sublevel of the clock transition, after the quenching laser transfers the ion to the ground state at each cycle. Using this method, the stability for 40 Ca + optical clock is improved to about . Compared with in previous work, the averaging time is decreased to reach a given level of statistical uncertainty in a clock comparison .
Abstract Here, we develop a compact multilayer magnetic shield for a transportable optical clock, achieving shielding factors of up to 10 5 . To improve the frequency stability of the transportable optical clock, we improved the magnetic-field environment of a transportable 40 Ca + ion optical clock (TCIOC) using the newly developed magnetic shielding system and reduced the clock-laser frequency noise by transferring the stability of an ultrastable reference laser through an optical frequency comb. These improvements enabled the coherent interrogation time to be extended from 40 ms to 320 ms . A time-interleaved self-comparison yielded a measured short-term fractional frequency instability of 1.6 × 10 − 15 / τ , close to the estimated quantum projection noise-limited instability of 1.18 × 10 − 15 / τ . Meanwhile, the uncertainty contributions associated with the DC second-order Zeeman shift and the servo error were reduced to 1.1 × 10 − 21 and 4.5 × 10 − 19 . These results provide a practical basis for further improving the performance of transportable optical clocks.