European Frequency and Time Forum
Stability Improvement of an Aluminum Ion Optical Clock
B. Wang, Z. Y. Ma, Liren Pang, R. Gong, S. Q. Wei, Ke Deng, J. Zhang, Z. H. Lu
Abstract
Based on the current initiative to redefine the SI “second”, the optical clock has been demonstrated by many laboratories as a favorable candidate due to its excellent performance indicators. We describe the evaluation of uncertainty and optimization of stability in an aluminum-ion optical clock system based on quantum logic spectroscopy. The uncertainty evaluation of the current optical clock system is$1.6\times 10^{-18}$. The frequency stability of a single system has been improved from 3.9$\times 10^{-15} / \sqrt{\tau}$to 2.6$\times 10^{-15} / \sqrt{\tau}$by using the servo-controlled self-comparison locking method.