Frequency Comparison of Two High-Accuracy Al + Optical Clocks

C. W. Chou, David B. Hume, Jeroen C. J. Koelemeij, D. J. Wineland, Till Rosenband

Published Feb 17, 2010• 899 citations
arXivHTMLPDF

Abstract

We have constructed an optical clock with a fractional frequency inaccuracy of 8.6x10{-18}, based on quantum logic spectroscopy of an Al+ ion. A simultaneously trapped Mg+ ion serves to sympathetically laser cool the Al+ ion and detect its quantum state. The frequency of the {1}S{0}<-->{3}P{0} clock transition is compared to that of a previously constructed Al+ optical clock with a statistical measurement uncertainty of 7.0x10{-18}. The two clocks exhibit a relative stability of 2.8x10{-15}tau{-1/2}, and a fractional frequency difference of -1.8x10{-17}, consistent with the accuracy limit of the older clock.

DOI
10.1103/physrevlett.104.070802

Related papers

High-Stability Single-Ion Clock with 5.5 × 10 − 19 Systematic Uncertainty

Mason C. Marshall, Daniel A. Rodriguez Castillo, Willa J. Arthur-Dworschack +10 more

We report a single-ion optical atomic clock with a fractional frequency uncertainty of 5.5×10^{-19} and fractional frequency stability of 3.5×10^{-16}/sqrt[τ/s], based on quantum logic spectroscopy of a single ^{27}Al^{+} ion. A cotrapped ^{25}Mg^{+} ion provides sympathetic cooling and quantum logic readout of the ^{27}Al^{+}^{1}S_{0}↔^{3}P_{0} clock transition. A Rabi probe duration of 1 s, enabled by laser stability transfer from a remote cryogenic silicon cavity across a 3.6 km fiber link, results in a threefold reduction in instability compared to previous ^{27}Al^{+} clocks. Systematic uncertainties are lower due to an improved ion trap electrical design, which reduces excess micromotion, and a new vacuum system, which reduces collisional shifts. We also perform a direction-sensitive measurement of the ac magnetic field due to the rf ion trap, eliminating systematic uncertainty due to field orientation.

arXiv:2504.13071•Physical Review Letters•Jul 14, 2025•63 citations

Quantum-logic-based 25 Mg + - 27 Al + optical frequency standard for the redefinition of the SI second

Zhiyu Ma, Ke Deng, Z. Y. Wang +13 more

Optical clocks have been demonstrated to be good choices to redefine the SI ``second.'' With this goal, we have constructed a quantum-logic-based ${}^{27}$$\mathrm{Al}$${}^{+}$ ion optical clock with a fractional frequency uncertainty of $1.6\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}18}$. A ${}^{25}$$\mathrm{Mg}$${}^{+}$ ion is used as the logic ion for sympathetic cooling, state readout, and frequency-shift measurement of the ${}^{27}$$\mathrm{Al}$${}^{+}$ ion. The stability of the optical clock is $2.6\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}15}/\sqrt{\ensuremath{\tau}}$, measured with a self-comparison method.

Physical Review Applied•Apr 8, 2024•17 citations

Al + 27 Quantum-Logic Clock with a Systematic Uncertainty below 10 − 18

Samuel M. Brewer, Jwo-Sy Chen, Aaron M. Hankin +5 more

We describe an optical atomic clock based on quantum-logic spectroscopy of the ^{1}S_{0}↔^{3}P_{0} transition in ^{27}Al^{+} with a systematic uncertainty of 9.4×10^{-19} and a frequency stability of 1.2×10^{-15}/sqrt[τ]. A ^{25}Mg^{+} ion is simultaneously trapped with the ^{27}Al^{+} ion and used for sympathetic cooling and state readout. Improvements in a new trap have led to reduced secular motion heating, compared to previous ^{27}Al^{+} clocks, enabling clock operation with ion secular motion near the three-dimensional ground state. Operating the clock with a lower trap drive frequency has reduced excess micromotion compared to previous ^{27}Al^{+} clocks. Both of these improvements have led to a reduced time-dilation shift uncertainty. Other systematic uncertainties including those due to blackbody radiation and the second-order Zeeman effect have also been reduced.

arXiv:1902.07694•Physical Review Letters•Jul 15, 2019•711 citations

Al+ Optical Clocks for Fundamental Physics and Geodesy

James Chin-wen Chou

Laser-cooled trapped atoms have long been recognized as potentially very accurate frequency standards for clocks. Ultimate accuracies of 10-18 to 10-19 appear possible, limited by the time-dilation of trapped ions that move at laser-cooled velocities. The Al+ ion is an attractive candidate for high accuracy, owing to its narrow electronic transition in the optical regime and low sensitivity to ambient field perturbations. Precision spectroscopy on Al+ is enabled by quantum information techniques. With Al+ “quantum-logic” clocks, the current accuracy of 8.6×10-18 has enabled a geo-potential-difference measurement that detected a height change of 37±17 cm due to the gravitational red-shift. We have also observed quantum coherence between two Al+ ions with a record Q-factor of 3.4×1016, and compared the Al+ resonance frequency to that of a single Hg+ ion to place limits on the temporal variation of the fine-structure constant.

•Jul 13, 2011•0 citations

A multi-ion optical clock with $\mathbf{5 \times 10^{-19}}$ uncertainty

Melina Filzinger, Martin R. Steinel, Jian Jiang +4 more

Today's most accurate clocks are based on laser spectroscopy of electronic transitions in single trapped ions and feature fractional frequency uncertainties below $1\times10^{-18}$. Scaling these systems to multiple, simultaneously interrogated ions reduces measurement times, driving recent advances in multi-ion clocks. However, maintaining state-of-the-art systematic uncertainties while increasing the number of ions remains a central challenge. Here, we report on a multi-ion optical atomic clock with a fractional frequency uncertainty of $5.3\times10^{-19}$ and up to 10 \Sr ions. Ion-resolved state detection enables minimization of position-dependent shifts, with residual effects suppressed below the $10^{-20}$-level. Clock operation with eight to ten ions reduces the measurement time by a factor of 4.8 compared to single-ion operation. A comparison with an established \Yb single-ion clock yields an unperturbed frequency ratio of $0.6926711632159660405(20)$, with a statistical uncertainty of $0.9\times10^{-18}$ and a combined uncertainty of $2.9\times 10^{-18}$. These results demonstrate robust multi-ion clock operation with reduced averaging time and state-of-the-art accuracy.

physics.atom-phCross-listedarXiv:2603.23446•Mar 25, 2026•0 citations

Single-Ion Optical Clock Based on Quantum Logic Spectroscopy

Kazuhiro Hayasaka

This paper presents an overview of the Al+ optical clock, which is based on quantum logic spectroscopy and provides the most accurate frequency measurement ever reported. Dehmelt’s original design of the optical clock was not realized due to the difficulty in generating the vacuum ultraviolet radiation necessary for laser cooling and the ion’s quantum state detection. The problem was solved by sympathetically cooling the ion with another ion and detecting the quantum state using the ancillary ion. The method, which is called quantum logic spectroscopy, comes from the use of phonon qubit as a bus of the quantum state of the ions in the Cirac-Zoller ion-trap quantum computer. The clock can be simplifi ed by introducing direct excitation by vacuum ultraviolet radiation or another ion species. The clock’s stability will be improved more than ten times by a middle-term stabilized clock laser.

The Review of Laser Engineering•Jan 1, 2013•1 citation
We have constructed an optical clock with a fractional frequency inaccuracy of 8.6x10{-18}, based on quantum logic spectroscopy of an Al+ ion. A simultaneously trapped Mg+ ion serves to sympathetically laser cool the Al+ ion and detect its quantum state. The frequency of the {1}S{0}<-->{3}P{0} clock transition is compared to that of a previously constructed Al+ optical clock with a statistical measurement uncertainty of 7.0x10{-18}. The two clocks exhibit a relative stability of 2.8x10{-15}tau{-1/2}, and a fractional frequency difference of -1.8x10{-17}, consistent with the accuracy limit of the older clock.
We report a single-ion optical atomic clock with a fractional frequency uncertainty of 5.5×10^{-19} and fractional frequency stability of 3.5×10^{-16}/sqrt[τ/s], based on quantum logic spectroscopy of a single ^{27}Al^{+} ion. A cotrapped ^{25}Mg^{+} ion provides sympathetic cooling and quantum logic readout of the ^{27}Al^{+}^{1}S_{0}↔^{3}P_{0} clock transition. A Rabi probe duration of 1 s, enabled by laser stability transfer from a remote cryogenic silicon cavity across a 3.6 km fiber link, results in a threefold reduction in instability compared to previous ^{27}Al^{+} clocks. Systematic uncertainties are lower due to an improved ion trap electrical design, which reduces excess micromotion, and a new vacuum system, which reduces collisional shifts. We also perform a direction-sensitive measurement of the ac magnetic field due to the rf ion trap, eliminating systematic uncertainty due to field orientation.
Optical clocks have been demonstrated to be good choices to redefine the SI ``second.'' With this goal, we have constructed a quantum-logic-based 27{}^{27}27Al\mathrm{Al}Al+{}^{+}+ ion optical clock with a fractional frequency uncertainty of $1.6\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}18}$. A 25{}^{25}25Mg\mathrm{Mg}Mg+{}^{+}+ ion is used as the logic ion for sympathetic cooling, state readout, and frequency-shift measurement of the 27{}^{27}27Al\mathrm{Al}Al+{}^{+}+ ion. The stability of the optical clock is $2.6\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}15}/\sqrt{\ensuremath{\tau}}$, measured with a self-comparison method.
We describe an optical atomic clock based on quantum-logic spectroscopy of the ^{1}S_{0}↔^{3}P_{0} transition in ^{27}Al^{+} with a systematic uncertainty of 9.4×10^{-19} and a frequency stability of 1.2×10^{-15}/sqrt[τ]. A ^{25}Mg^{+} ion is simultaneously trapped with the ^{27}Al^{+} ion and used for sympathetic cooling and state readout. Improvements in a new trap have led to reduced secular motion heating, compared to previous ^{27}Al^{+} clocks, enabling clock operation with ion secular motion near the three-dimensional ground state. Operating the clock with a lower trap drive frequency has reduced excess micromotion compared to previous ^{27}Al^{+} clocks. Both of these improvements have led to a reduced time-dilation shift uncertainty. Other systematic uncertainties including those due to blackbody radiation and the second-order Zeeman effect have also been reduced.
Laser-cooled trapped atoms have long been recognized as potentially very accurate frequency standards for clocks. Ultimate accuracies of 10-18 to 10-19 appear possible, limited by the time-dilation of trapped ions that move at laser-cooled velocities. The Al+ ion is an attractive candidate for high accuracy, owing to its narrow electronic transition in the optical regime and low sensitivity to ambient field perturbations. Precision spectroscopy on Al+ is enabled by quantum information techniques. With Al+ “quantum-logic” clocks, the current accuracy of 8.6×10-18 has enabled a geo-potential-difference measurement that detected a height change of 37±17 cm due to the gravitational red-shift. We have also observed quantum coherence between two Al+ ions with a record Q-factor of 3.4×1016, and compared the Al+ resonance frequency to that of a single Hg+ ion to place limits on the temporal variation of the fine-structure constant.
A multi-ion optical clock with 5×10−19\mathbf{5 \times 10^{-19}}5×10−19 uncertainty
Today's most accurate clocks are based on laser spectroscopy of electronic transitions in single trapped ions and feature fractional frequency uncertainties below 1×10−181\times10^{-18}1×10−18. Scaling these systems to multiple, simultaneously interrogated ions reduces measurement times, driving recent advances in multi-ion clocks. However, maintaining state-of-the-art systematic uncertainties while increasing the number of ions remains a central challenge. Here, we report on a multi-ion optical atomic clock with a fractional frequency uncertainty of 5.3×10−195.3\times10^{-19}5.3×10−19 and up to 10 \Sr ions. Ion-resolved state detection enables minimization of position-dependent shifts, with residual effects suppressed below the 10−2010^{-20}10−20-level. Clock operation with eight to ten ions reduces the measurement time by a factor of 4.8 compared to single-ion operation. A comparison with an established \Yb single-ion clock yields an unperturbed frequency ratio of 0.6926711632159660405(20)0.6926711632159660405(20)0.6926711632159660405(20), with a statistical uncertainty of 0.9×10−180.9\times10^{-18}0.9×10−18 and a combined uncertainty of 2.9×10−182.9\times 10^{-18}2.9×10−18. These results demonstrate robust multi-ion clock operation with reduced averaging time and state-of-the-art accuracy.
This paper presents an overview of the Al+ optical clock, which is based on quantum logic spectroscopy and provides the most accurate frequency measurement ever reported. Dehmelt’s original design of the optical clock was not realized due to the difficulty in generating the vacuum ultraviolet radiation necessary for laser cooling and the ion’s quantum state detection. The problem was solved by sympathetically cooling the ion with another ion and detecting the quantum state using the ancillary ion. The method, which is called quantum logic spectroscopy, comes from the use of phonon qubit as a bus of the quantum state of the ions in the Cirac-Zoller ion-trap quantum computer. The clock can be simplifi ed by introducing direct excitation by vacuum ultraviolet radiation or another ion species. The clock’s stability will be improved more than ten times by a middle-term stabilized clock laser.