Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

AVS Quantum Science

40Ca+ optical clocks in China

Hua Guan, Baolin Zhang, Huaqing Zhang, Yao Huang, Yanmei Hao, Mengyan Zeng, Kelin Gao

Published Oct 11, 2021• 4 citations
Publisher

Abstract

In this review, the improvements made in the past two decades for 40Ca+ optical clocks in China are presented. Uncertainty of below 1.3×10−17 was achieved by applying the “magic” RF trapping frequency and introducing a generalized Ramsey excitation scheme. The stability of 40Ca+ optical clocks has been improved to 2.5×10−15/τ with an uptime rate of 93.8% by implementing two ameliorated lock algorithms in the Ramsey excitation scheme. A long-term clock frequency comparison shows a clock stability of 6.3 × 10−18 in an averaging time of 524 000 s. A robust and transportable clock installed in an air-conditioned car trailer can achieve almost the same performance of laboratory clocks. A height difference between transportable and laboratory clocks was measured with an uncertainty of 0.33 m and the absolute frequency of 40Ca+ optical clock transitions was remeasured as 411 042 129 776 400.41(23) Hz, with a fractional uncertainty of 5.6×10−16 based on a Cs fountain clock in the National Institute of Metrology after the transportable clock was transported from Wuhan to Beijing. The author predicts that transportable single-ion optical clocks especially based on the 40Ca+ will make a significant contribution to the construction of a world-wide optical clock network and the redefinition of the unit of time in the future.

DOI
10.1116/5.0056771

Related papers

Improvement in the stability of a 40Ca+ ion optical clock using the Ramsey method

Baolin Zhang, Yao Huang, Yanmei Hao +4 more

The fractional uncertainty of the 40Ca+ optical clock in our laboratory has been evaluated to be 2.2×10−17, but it is difficult to evaluate the statistical uncertainty of the output frequency at this level, limited by the frequency stability associated with the quantum projection noise (QPN). A reduction in the stability is required to shorten the averaging time for a certain statistical uncertainty level. To improve the stability, the Ramsey method is introduced in the locking process. To improve the reliability and continuity, we introduce the idea of using auxiliary Rabi probes to avoid fringe slips in the Ramsey interrogation and to automatically search for resonance. The stability of a single 40Ca+ ion frequency standard is improved from 6.3×10−15/τ to 2.5×10−15/τ, where τ is the averaging time in seconds, which is close to the QPN limit for an 80-ms-long Ramsey interrogation. We obtain a stability of 1.5×10−17 at an averaging time of 21 000 s and an uptime rate of 93.8% for a 34-h-long run. These methods can easily be applied to other ion or neutral atom optical clocks.

Journal of Applied Physics•Oct 14, 2020•15 citations

A compact, transportable optical clock with 1×10−17 uncertainty and its absolute frequency measurement

Jian Zhong Cao, Jinbo Yuan, Shaomao Wang +13 more

We report a robust, compact, and transportable optical clock (TOC-729-2) based on a trapped single 40Ca+ ion with a systematic uncertainty of 1.1×10−17, which is limited by the black-body radiation shift uncertainty at room temperature. By comparing it with the previous transportable optical clock (TOC-729-1) similar but completely independent, the instability was measured to be better than 1.2×10−14/τ. Benefiting from the modular and integrated design, this TOC was constructed in a volume of ∼0.33 m3 excluding the controlling electronics in 19-in. racks. After being moved ∼1200 km away by express delivery, the single-ion signal was restored within 24 h. With the TOC uptime of 92% in 35-day period, the absolute frequency of the 729 nm transition of 40Ca+ was measured using a satellite link to International Atomic Time (TAI) to provide traceability to the SI second, and the result is 411 042 129 776 400.15(22) Hz, corresponding to a relative uncertainty of 5.3×10−16.

Applied Physics Letters•Jan 31, 2022•22 citations

40Ca+ optical frequency standards with high accuracy

Guan Hua, Yao Huang, Chengbin Li +1 more

With the development of the technologies in the lasers and the manipulation of cold atoms, the high precision optical frequency standards have been extensively studied and built in recent years. These high precision frequency standards may play an important role in establishing the new time reference, promoting the researches in the fundamental fields, fulfilling the national strategic needs, etc. In this paper, the research progress of high accuracy 40Ca+ optical frequency standard in Wuhan Institute of Physics and Mathematics (WIPM) of Chinese Academy of Sciences is presented. A new ULE super cavity is adopted for stabilizing the frequency of 729 nm clock laser, and the stability of the laser is improved now to 2×10-15 in a duration of 1-100 s. By controlling the external fields and other environmental influences, especially suppressing the micromotion effects of the trapped ion, the uncertainty of the optical frequency standard based on a single 40Ca+ is reduced to 5.5×10-17. The stability of 5×10-17 in a duration of 20000 s is achieved via the comparison between two 40Ca+ optical frequency standards. Several precision measurement experiments are performed, based on the high precision 40Ca+ optical frequency standard. The absolute value of the clock transition frequency of the 40Ca+ optical frequency standard is measured second time, using an optical comb referenced to a hydrogen maser which is calibrated via GPS referenced to UTC (NIM)) using the precise point positioning data-processing technique. The frequency offset of UTC (NIM) relative to the SI second can be evaluated through BIPM circular-T reports, and the newly measured value of m 4s 2S1/2-3m d 2D5/2 transition is adopted by CCTF-20, thus updating the recommended value of 40Ca+ optical clock transition. Besides the absolute frequency measurement, the magic wavelengths of 40Ca+ optical clock transition are measured precisely, and this work is a milestone for establishing all-optical trapped-ion clocks. The lifetime of the m 3 d 2D3/2 and m 3 d 2D5/2 state in 40Ca+ are precisely measured, too. The work mentioned above contributes to the researches of the precision measurements based on cold atomic systems.

Acta Physica Sinica•Jan 1, 2018•4 citations

Single-ion, transportable optical atomic clocks

Marion Delehaye, Clément Lacroûte

For the past 15 years, tremendous progress within the fields of laser stabilization, optical frequency combs and atom cooling and trapping have allowed the realization of optical atomic clocks with unrivaled performances. These instruments can perform frequency comparisons with fractional uncertainties well below 10-17, finding applications in fundamental physics tests, relativistic geodesy and time and frequency metrology. Even though most optical clocks are currently laboratory setups, several proposals for using these clocks for field measurements or within an optical clock network have been published, and most of time and frequency metrology institutes have started to develop transportable optical clocks. For the purpose of this special issue, we chose to focus on trapped-ion optical clocks. Even though their short-term fractional frequency stability is impaired by a lower signal-to-noise ratio, they offer a high potential for compactness: trapped ions demand low optical powers and simple loading schemes, and can be trapped in small vacuum chambers. We review recent advances on the clock key components, including ion trap and ultra-stable optical cavity, as well as existing projects and experiments which draw the picture of what future transportable, single-ion optical clocks may resemble.

arXiv:1804.02168•Journal of Modern Optics•Mar 7, 2018•42 citations

The progress of the precision spectroscopy with single trapped and laser cooled 40Ca+ ion

Hua Guan, 高克林, Yao HUANG

The experimental study at Wuhan Institute of Physics and Mathematics (WIPM), Chinese Academy of Scienses (CAS) on the precision spetroscopy based on single trapped Ca+ ion is described in this paper. A single Ca+ ion is trapped in a miniature Paul trap and laser cooled to Lamb-Dicke regime, and the ion can be trapped more than 2 months. The linewidth of the 729 nm laser for probing the Ca+ 4s2S1/2-3d2D5/2 clock transition is reduced to lessthan 1 Hz by locked to a super cavity, and the 729 nm laser can be locked more than 1 month continuously. Two similar Ca + ion optical frequency standards are set up for frequency comparison. The systematic uncertainty is evaluated to be <6 ´ 10−17 for both ftrquency standards. The frequency difference of two frequency standards is measured to be 3.0 (5.5) ´ 10−17 within 42 d. The Allan deviation for a single clock is measured to be 1×10−14τ−1/2 with a 3-d-continuous comparison, the stability for a reaches 7 ´ 10−17 at an averaging time of 20000 s. Meanwhile, the absolute frequency of the Ca+ 4s2S1/2-3d2D5/2 clock transition is measured to be 411042129776401.7(1.1) Hz with respect to the SI second through the Global Positioning System (GPSx). The precision spectroscopy experiments are carried out based on the single Ca+ ion system. The magic wavelengths for the Ca+ optical frequency standardare measured to be λ|mj|=1/2=395.7992(7) nm and λ|mj|=3/2=395.7990(7) nm, which agrees with theoretical calculation made by Tang et al. The lifetime of the 3d2D5/2 is measured to be 1174(10) ms, which is agree with the experimental measurement made by University of Oxford and University of Innsbruck and the recent theoretical calculation made by Sahoo.

Zhongguo kexue. Wulixue Lixue Tianwenxue•Jun 17, 2016•0 citations

Progress towards a 40Ca+ optical clock with a fractional uncertainty at the 10−18 level

Yao Huang, Hua Guan, Kelin Gao

We recently reported a 5×10-17level frequency comparison of two40Ca+optical clocks, one of which has fractional frequency uncertainty of 3.4×10-17, limited by the BBR effect. Here we present progress towards a40Ca+optical clock with uncertainty at the 10-18level. The differential static scalar polarizability Δα0 of the40Ca+ion clock transition is obtained by precisely measuring the “magic” rf drive frequency. Δα0 is measured as -7.2653(44)x10-40J m2/V2, the blackbody radiation shift is then calculated to be 0.3790(2) Hz at 300 K. The contribution of the blackbody shift coefficient to the uncertainty of the optical clock at room temperature is reduced to 5.6×10-19, the excess micromotion induced clock uncertainty is also reduced to the 10-19level by choosing the appropriate trap drive frequency. With a suppression of the BBR field temperature uncertainty to the sub-Kelvin level and improved clock stability, a robust, relatively low-cost40Ca+ion clock with uncertainty at 10-18level can be made.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•Jul 1, 2017•0 citations
In this review, the improvements made in the past two decades for 40Ca+ optical clocks in China are presented. Uncertainty of below 1.3×10−17 was achieved by applying the “magic” RF trapping frequency and introducing a generalized Ramsey excitation scheme. The stability of 40Ca+ optical clocks has been improved to 2.5×10−15/τ with an uptime rate of 93.8% by implementing two ameliorated lock algorithms in the Ramsey excitation scheme. A long-term clock frequency comparison shows a clock stability of 6.3 × 10−18 in an averaging time of 524 000 s. A robust and transportable clock installed in an air-conditioned car trailer can achieve almost the same performance of laboratory clocks. A height difference between transportable and laboratory clocks was measured with an uncertainty of 0.33 m and the absolute frequency of 40Ca+ optical clock transitions was remeasured as 411 042 129 776 400.41(23) Hz, with a fractional uncertainty of 5.6×10−16 based on a Cs fountain clock in the National Institute of Metrology after the transportable clock was transported from Wuhan to Beijing. The author predicts that transportable single-ion optical clocks especially based on the 40Ca+ will make a significant contribution to the construction of a world-wide optical clock network and the redefinition of the unit of time in the future.
The fractional uncertainty of the 40Ca+ optical clock in our laboratory has been evaluated to be 2.2×10−17, but it is difficult to evaluate the statistical uncertainty of the output frequency at this level, limited by the frequency stability associated with the quantum projection noise (QPN). A reduction in the stability is required to shorten the averaging time for a certain statistical uncertainty level. To improve the stability, the Ramsey method is introduced in the locking process. To improve the reliability and continuity, we introduce the idea of using auxiliary Rabi probes to avoid fringe slips in the Ramsey interrogation and to automatically search for resonance. The stability of a single 40Ca+ ion frequency standard is improved from 6.3×10−15/τ to 2.5×10−15/τ, where τ is the averaging time in seconds, which is close to the QPN limit for an 80-ms-long Ramsey interrogation. We obtain a stability of 1.5×10−17 at an averaging time of 21 000 s and an uptime rate of 93.8% for a 34-h-long run. These methods can easily be applied to other ion or neutral atom optical clocks.
We report a robust, compact, and transportable optical clock (TOC-729-2) based on a trapped single 40Ca+ ion with a systematic uncertainty of 1.1×10−17, which is limited by the black-body radiation shift uncertainty at room temperature. By comparing it with the previous transportable optical clock (TOC-729-1) similar but completely independent, the instability was measured to be better than 1.2×10−14/τ. Benefiting from the modular and integrated design, this TOC was constructed in a volume of ∼0.33 m3 excluding the controlling electronics in 19-in. racks. After being moved ∼1200 km away by express delivery, the single-ion signal was restored within 24 h. With the TOC uptime of 92% in 35-day period, the absolute frequency of the 729 nm transition of 40Ca+ was measured using a satellite link to International Atomic Time (TAI) to provide traceability to the SI second, and the result is 411 042 129 776 400.15(22) Hz, corresponding to a relative uncertainty of 5.3×10−16.
With the development of the technologies in the lasers and the manipulation of cold atoms, the high precision optical frequency standards have been extensively studied and built in recent years. These high precision frequency standards may play an important role in establishing the new time reference, promoting the researches in the fundamental fields, fulfilling the national strategic needs, etc. In this paper, the research progress of high accuracy 40Ca+ optical frequency standard in Wuhan Institute of Physics and Mathematics (WIPM) of Chinese Academy of Sciences is presented. A new ULE super cavity is adopted for stabilizing the frequency of 729 nm clock laser, and the stability of the laser is improved now to 2×10-15 in a duration of 1-100 s. By controlling the external fields and other environmental influences, especially suppressing the micromotion effects of the trapped ion, the uncertainty of the optical frequency standard based on a single 40Ca+ is reduced to 5.5×10-17. The stability of 5×10-17 in a duration of 20000 s is achieved via the comparison between two 40Ca+ optical frequency standards. Several precision measurement experiments are performed, based on the high precision 40Ca+ optical frequency standard. The absolute value of the clock transition frequency of the 40Ca+ optical frequency standard is measured second time, using an optical comb referenced to a hydrogen maser which is calibrated via GPS referenced to UTC (NIM)) using the precise point positioning data-processing technique. The frequency offset of UTC (NIM) relative to the SI second can be evaluated through BIPM circular-T reports, and the newly measured value of m 4s 2S1/2-3m d 2D5/2 transition is adopted by CCTF-20, thus updating the recommended value of 40Ca+ optical clock transition. Besides the absolute frequency measurement, the magic wavelengths of 40Ca+ optical clock transition are measured precisely, and this work is a milestone for establishing all-optical trapped-ion clocks. The lifetime of the m 3 d 2D3/2 and m 3 d 2D5/2 state in 40Ca+ are precisely measured, too. The work mentioned above contributes to the researches of the precision measurements based on cold atomic systems.
For the past 15 years, tremendous progress within the fields of laser stabilization, optical frequency combs and atom cooling and trapping have allowed the realization of optical atomic clocks with unrivaled performances. These instruments can perform frequency comparisons with fractional uncertainties well below 10-17, finding applications in fundamental physics tests, relativistic geodesy and time and frequency metrology. Even though most optical clocks are currently laboratory setups, several proposals for using these clocks for field measurements or within an optical clock network have been published, and most of time and frequency metrology institutes have started to develop transportable optical clocks. For the purpose of this special issue, we chose to focus on trapped-ion optical clocks. Even though their short-term fractional frequency stability is impaired by a lower signal-to-noise ratio, they offer a high potential for compactness: trapped ions demand low optical powers and simple loading schemes, and can be trapped in small vacuum chambers. We review recent advances on the clock key components, including ion trap and ultra-stable optical cavity, as well as existing projects and experiments which draw the picture of what future transportable, single-ion optical clocks may resemble.
The experimental study at Wuhan Institute of Physics and Mathematics (WIPM), Chinese Academy of Scienses (CAS) on the precision spetroscopy based on single trapped Ca+ ion is described in this paper. A single Ca+ ion is trapped in a miniature Paul trap and laser cooled to Lamb-Dicke regime, and the ion can be trapped more than 2 months. The linewidth of the 729 nm laser for probing the Ca+ 4s2S1/2-3d2D5/2 clock transition is reduced to lessthan 1 Hz by locked to a super cavity, and the 729 nm laser can be locked more than 1 month continuously. Two similar Ca + ion optical frequency standards are set up for frequency comparison. The systematic uncertainty is evaluated to be <6 ´ 10−17 for both ftrquency standards. The frequency difference of two frequency standards is measured to be 3.0 (5.5) ´ 10−17 within 42 d. The Allan deviation for a single clock is measured to be 1×10−14τ−1/2 with a 3-d-continuous comparison, the stability for a reaches 7 ´ 10−17 at an averaging time of 20000 s. Meanwhile, the absolute frequency of the Ca+ 4s2S1/2-3d2D5/2 clock transition is measured to be 411042129776401.7(1.1) Hz with respect to the SI second through the Global Positioning System (GPSx). The precision spectroscopy experiments are carried out based on the single Ca+ ion system. The magic wavelengths for the Ca+ optical frequency standardare measured to be λ|mj|=1/2=395.7992(7) nm and λ|mj|=3/2=395.7990(7) nm, which agrees with theoretical calculation made by Tang et al. The lifetime of the 3d2D5/2 is measured to be 1174(10) ms, which is agree with the experimental measurement made by University of Oxford and University of Innsbruck and the recent theoretical calculation made by Sahoo.
We recently reported a 5×10-17level frequency comparison of two40Ca+optical clocks, one of which has fractional frequency uncertainty of 3.4×10-17, limited by the BBR effect. Here we present progress towards a40Ca+optical clock with uncertainty at the 10-18level. The differential static scalar polarizability Δα0 of the40Ca+ion clock transition is obtained by precisely measuring the “magic” rf drive frequency. Δα0 is measured as -7.2653(44)x10-40J m2/V2, the blackbody radiation shift is then calculated to be 0.3790(2) Hz at 300 K. The contribution of the blackbody shift coefficient to the uncertainty of the optical clock at room temperature is reduced to 5.6×10-19, the excess micromotion induced clock uncertainty is also reduced to the 10-19level by choosing the appropriate trap drive frequency. With a suppression of the BBR field temperature uncertainty to the sub-Kelvin level and improved clock stability, a robust, relatively low-cost40Ca+ion clock with uncertainty at 10-18level can be made.