Optical lattice clocks demonstrate advantages in metrology and frontier physics because of their high stability.Here, we present approaches to enhancing the stability by decoupling the noise related to the short-term and long-term stability.For the short-term stability, we optimize the clock laser by decoupling the frequency noise, and optimize each noise contribution individually until it is below the thermal noise limit.For the long-term stability, we introduce a method to decouple the instability caused by systematic effects.Having identified that the collision frequency shift was the main limiting factor in our systems, we thus optimized the atom number fluctuations in optical lattices.Through targeted optimization, we achieve a synchronous comparison of two clocks with an average stability of 3.2 × 10 -16 = τ p and a long-term stability of 2.4 × 10 -18 at 8000 s.This work provides an analytical framework for enhancing optical clock stability.
Optical lattice clocks demonstrate advantages in metrology and frontier physics because of their high stability.Here, we present approaches to enhancing the stability by decoupling the noise related to the short-term and long-term stability.For the short-term stability, we optimize the clock laser by decoupling the frequency noise, and optimize each noise contribution individually until it is below the thermal noise limit.For the long-term stability, we introduce a method to decouple the instability caused by systematic effects.Having identified that the collision frequency shift was the main limiting factor in our systems, we thus optimized the atom number fluctuations in optical lattices.Through targeted optimization, we achieve a synchronous comparison of two clocks with an average stability of 3.2 × 10 -16 = τ p and a long-term stability of 2.4 × 10 -18 at 8000 s.This work provides an analytical framework for enhancing optical clock stability.
Frequency metrology underpins precise measurements. At the forefront of this field are optical clocks which can perform measurements that are accurate to more digits than those in the number representing seconds elapsed from the beginning of the universe. Frequency estimation errors in the operation of optical clocks lead to frequency instability, prohibiting them from reaching high accuracies on short to medium time scales, and limiting access to interesting measurements of the atomic environment and exotic external perturbations such as gravity fields or fields of fundamentally new physical origins. Optical lattice traps are typically employed in state-of-the-art optical clocks to suppress Doppler effects. By carefully tuning the optical lattice to the magic wavelength, unwanted Stark shifts can be suppressed significantly, allowing operation with thousands of atoms and minimising the fundamental source of frequency estimation errors, namely the quantum projection noise, to around 3 × 10−17 at 1 s. In this thesis, the status of the two Strontium optical lattice clocks at NPL, Sr1 and Sr2, is presented going over a few interesting measurement campaigns from the past years involving Sr1 and the latest experimental efforts to re-enable operation of Sr2. A model of clock stability is developed by incorporating known and new frameworks to characterise the relation between the operating parameters of optical clocks and their performance, with relevance to the NPL lattice clocks and beyond. In particular, a method is identified for addressing the main technical noise for optical lattice clocks, the Dick effect, which typically has a magnitude of 10−16 at 1 s and prevents optical lattice clocks from reaching the quantum projection noise level. By taking advantage of dynamical decoupling we can engineer an optimised duty cycle with benefits in general for systems limited by the optical coherence of the clock laser. Moreover, a study of other noise sources in the NPL lattice clocks is conducted using synchronous measurements between Sr1 and Sr2, revealing a large contribution from linear Zeeman shifts, also at the 10−16 level, and a plan to tackle them is detailed. A hybrid clock architecture is discussed showing how optical lattice clocks can improve the optical coherence of ion clocks thanks to their higher servo rate, and a preliminary experimental demonstration is reported. Finally, a new type of spectroscopy is presented which completely avoids aliasing of linear Zeeman shifts by simultaneously driving transitions with opposite Zeeman sensitivities. Such a technique also enables the continuous interrogation of atoms, a crucial missing component in the Dick-free conveyor belt lattice clock concept heralded as the next standard of stable optical clocks.
Neutral atom optical standards require the highest levels of laser precision to operate near the limit set by quantum fluctuations. We develop state-of-the-art ultra-stable laser systems to achieve a factor of 10 enhancement in clock measurement precision and additionally demonstrate optical linewidths below 50 mHz. The most stable of these lasers reaches its thermal noise floor of 1 × 10-16 fractional frequency instability, allowing the attainment of near quantum-noise-limited clock operation with single-clock instabilities of 3×10-16 at 1 s. We utilize this high level of spectral resolution to operate a 87Sr optical lattice clock in a regime in which quantum collisions play a dominant role in the dynamics, enabling the study of quantum many-body physics. With a fractional level of precision of near 1 × 10-16 at 1 s, we clearly resolve the signatures of many-body interactions. We find that the complicated interplay between the p wave-dominated elastic and inelastic interaction processes between lattice-trapped atoms leads to severe lineshape distortion, shifts, and loss of Ramsey fringe contrast. We additionally explore the theoretical prediction that these many-body interactions will modify the quantum fluctuations of the system and we find that in certain parameter regimes the quantum noise distribution exhibits a quadrature dependence. We further present technological advancements that will permit ultra-stable lasers to operate with reduced thermal noise, leading to a potential gain of an additional factor of 10 in stability. This indicates that laser fractional frequency instabilities of 1 × 10-17 are within experimental reach, as is a fully-quantum-limited regime of optical clock operation.
Many-particle optical lattice clocks have the potential for unprecedented measurement precision and stability due to their low quantum projection noise. However, this potential has so far never been realized because clock stability has been limited by frequency noise of optical local oscillators. By synchronously probing two 87Sr lattice systems using a laser with a thermal noise floor of $1\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}15}$, we remove classically correlated laser noise from the intercomparison, but this does not demonstrate independent clock performance. With an improved optical oscillator that has a $1\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}16}$ thermal noise floor, we demonstrate an order of magnitude improvement over the best reported stability of any independent clock, achieving a fractional instability of $1\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}17}$ in 1000 s of averaging time for synchronous or asynchronous comparisons. This result is within a factor of 2 of the combined quantum projection noise limit for a 160 ms probe time with $\ensuremath{\sim}{10}^{3}$ atoms in each clock. We further demonstrate that even at this high precision, the overall systematic uncertainty of our clock is not limited by atomic interactions. For the second Sr clock, which has a cavity-enhanced lattice, the atomic-density-dependent frequency shift is evaluated to be $\ensuremath{-}3.11\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}17}$ with an uncertainty of $8.2\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}19}$.
The frequency stability of many optical atomic clocks is limited by the coherence of their local oscillator. Here, we present a measurement protocol that overcomes the laser coherence limit. It relies on engineered dynamical decoupling of laser phase noise and near-synchronous interrogation of two clocks. One clock coarsely tracks the laser phase using dynamical decoupling; the other refines this estimate using a high-resolution phase measurement. While the former needs to have a high signal-to-noise ratio, the latter clock may operate with any number of particles. The protocol effectively enables minute-long Ramsey interrogation for coherence times of few seconds as provided by the current best ultrastable laser systems. We demonstrate implementation of the protocol in a realistic proof-of-principle experiment, where we interrogate for 0.5 s at a laser coherence time of 77 ms. Here, a single lattice clock is used to emulate synchronous interrogation of two separate clocks in the presence of artificial laser frequency noise. We discuss the frequency instability of a single-ion clock that would result from using the protocol for stabilisation, under these conditions and for minute-long interrogation, and find expected instabilities of σy(τ) = 8 × 10−16(τ/s)−1/2 and σy(τ) = 5 × 10−17(τ/s)−1/2, respectively.
Objective System stability and uncertainty are the two most important indicators of a clock, which represent the fluctuation of the clock output frequency in the time domain and the possible deviation between the clock output frequency and the absolute frequency, respectively. Stability improvement can reduce the measurement error of system frequency shifts and thus decrease systematic uncertainty. At present, the factors that limit the stability of an optical lattice clock mainly include quantum projection noise and Dick noise. By extending the optical probing time (τp), the effective operating rate of the clock can be improved, and the quantum projection noise and Dick noise can be reduced at the same time. However, compared with those of a case having smaller τp (such as 100 ms), the collisional frequency shifts are in the same order of magnitude as the Rabi frequency, and the loss of particles in the excited state due to inelastic scattering is enhanced when both τp and the number of atoms are large (e.g., τp=500 ms, N=6000). At the same time, the difference in Rabi frequency between the atoms in different external states and different lattice sites also rises (inhomogeneous excitation induced by atomic temperature, atomic interactions, clock laser frequency noise, and the detuning angle between the clock laser and the lattice light). All these factors make the excitation fraction of the clock transition spectrum line decrease and the linewidth widen when τp is large and eventually lead to the stability of the clock below the corresponding Dick limit. Methods In this paper, based on the prototype of the 87Sr one-dimensional space optical lattice clock, we experimentally observe the influence of atomic interactions on spectral linewidth and excitation fraction and even the corresponding influence on system stability. In the experiment, we measure the Rabi spectrum of clock transition at 6000 and 2000 atoms. In the measurements, the atomic temperature is kept at 3 μK (for T is constant, the number of atoms is proportional to the atomic density). The detuning angle between the clock laser and the lattice light is 13 mrad, and the optical probing time is set as 500 ms. Additionally, the stability of the optical lattice clock at two different atomic densities (for 6000 and 2000 atoms, respectively) is measured by the interleaved self-comparison method. Results and Discussions The research results of the dramatic effect of atomic interactions on the Rabi spectrum (Fig. 4) are shown. The Rabi spectrum of clock transition at the high atomic density (6000 atoms) is achieved experimentally, which has a maximum excitation fraction of 0.49 and a full width at half maximum (FWHM) of 4 Hz [Fig. 4(a)]. On the contrary, the maximum excitation fraction is 0.68, and the FWHM is 1.9 Hz under the condition of the low atomic density (2000 atoms) [Fig. 4(c)]. The results clearly demonstrate that the suppression of the excitation fraction and the broadening of the spectrum are caused by atomic interactions [Fig. 4(a) and (c)], which is coincident with the theoretical expectation. Moreover, when the clock laser resonates with the clock transition, the atoms trapped in the lattice are decreased distinctly [Fig. 4(b)]. This indicates that inelastic collisions between excited particles make a part of atoms escape from the trapping of the lattice. When the total number of atoms is reduced, the atomic loss caused by inelastic collisions is nearly not observed [Fig. 4(d)] in the experimental setup. This result also conforms to the two-body interaction theory. We also present the experimental results of the self-comparison stability at high and low atomic densities (Fig. 5). The self-comparison stability under the high-density condition is 2.6×10-15 (τ/s)-0.5, while it is 1×10-15 (τ/s)-0.5 under the low-density condition. The stability of the system is improved to 2.6 times by reducing the number of atoms. Conclusions In summary, the suppression of the excitation fraction and the broadening of the clock transition spectrum induced by atomic interactions are observed experimentally on the prototype of the 87Sr one-dimensional space optical lattice clock, and the atomic loss due to inelastic collisions is also found. The Rabi spectra are measured experimentally in the conditions of 6000 and 2000 atoms in lattice. The excitation fraction and linewidth for the large number of atoms are 0.49 and 4 Hz, and those for the small number of atoms are 0.68 and 1.9 Hz, respectively. At the same time, the atomic loss caused by inelastic collisions is also observed when the number of atoms is large. In the experiment, by measuring self-comparison stability at different atomic densities, we confirm that reducing the number of atoms to 1/3 can improve the system stability by 1.6 times. Finally, a spectrum with a linewidth of 1.9 Hz is achieved, and the self-comparison stability of the prototype of the space optical lattice clock is improved to 1×10-15 (τ/s)-0.5. The experimental results in this paper are significant for the study of the influence of many-body interactions in optical lattices on the clock transition spectrum. The measurement results of stability show that the best stability can be obtained by optimizing the atomic density of the optical lattice atomic clock.
Laser noise usually limits the stability of optical frequency ratio measurements, limiting the speed and precision one can compare two atomic frequency standards. In this talk I will describe two methods, correlation and differential spectroscopy, which utilize correlations in laser noise to increase the achievable interrogation time and thus increase the frequency comparison stability. Correlation spectroscopy is a technique which uses a parity measurement following a synchronized Ramsey interrogation to measure the relative frequency of two similar frequency atomic clocks. With this technique we achieve a measurement instability of (4×10^(-16))⁄√(τ⁄s) for a comparison of two single 27Al+ ion clocks. Differential spectroscopy uses an atomic clock with low projection noise, here a 171Yb lattice clock, to correct the phase noise of a second, higher frequency clock’s local oscillator thereby reducing the measurement instability to the level of the first. This can be further extended using two lattice clocks in a zero dead time configuration to correct the phase noise beyond the interrogation time reachable for a single Yb lattice clock. With these techniques we achieve measurement stabilities of (2.5×10^(-16))⁄√(τ⁄s) and (2×10^(-16))⁄√(τ⁄s) for a comparison between a single 27Al+ ion clock and a 171Yb lattice clock running as single clock and in a zero dead time configuration respectively. In addition to these techniques, I will also discuss recent progress towards characterizing the systematics of the NIST 40Ca+/27Al+ optical atomic clock.