Atomic clocks represent the most advanced instruments for providing time-frequency standards, with increasing demand for designs that offer high frequency stability while minimizing size. Central to an atomic clock’s function is the atomic vapor cell, which serves as the quantum reference. Compared to traditional cells, wafer-level micro-electro-mechanical systems (MEMS) vapor cells enable cost-effective, scalable production and facilitate integration with silicon-based chips. In this work, we present a wafer-level MEMS vapor cell featuring an innovative silicon-glass-silicon transverse optical path structure. A single wafer is used to fabricate 24 identical atomic vapor cells, each with precise dimensions of 14 mm×14 mm×4.3 mm, ensuring scalability. We demonstrate an optical frequency standard that combines modulation transfer spectroscopy (MTS) with a MEMS vapor cell, featuring a compact design with excellent performance. This frequency standard achieves stability over averaging times of 1–400 s, with short-term stability of 2.6×10 −13 at 1 s and 5.1×10 −14 at 200 s. The laser linewidth is only 3.9 kHz, marking a substantial improvement over existing thermal standards, and opening potential applications in navigation, radar, and precision measurement. This work provides a crucial step toward the development of chip-scale optical clocks.
Atomic clocks represent the most advanced instruments for providing time-frequency standards, with increasing demand for designs that offer high frequency stability while minimizing size. Central to an atomic clock’s function is the atomic vapor cell, which serves as the quantum reference. Compared to traditional cells, wafer-level micro-electro-mechanical systems (MEMS) vapor cells enable cost-effective, scalable production and facilitate integration with silicon-based chips. In this work, we present a wafer-level MEMS vapor cell featuring an innovative silicon-glass-silicon transverse optical path structure. A single wafer is used to fabricate 24 identical atomic vapor cells, each with precise dimensions of 14 mm×14 mm×4.3 mm, ensuring scalability. We demonstrate an optical frequency standard that combines modulation transfer spectroscopy (MTS) with a MEMS vapor cell, featuring a compact design with excellent performance. This frequency standard achieves stability over averaging times of 1–400 s, with short-term stability of 2.6×10 −13 at 1 s and 5.1×10 −14 at 200 s. The laser linewidth is only 3.9 kHz, marking a substantial improvement over existing thermal standards, and opening potential applications in navigation, radar, and precision measurement. This work provides a crucial step toward the development of chip-scale optical clocks.
This work introduces an innovative optical frequency standard that leverages MEMS vapor cells to achieve exceptional stability. To attain these objectives, we have integrated the modulation transfer spectroscopy (MTS) technique, which not only ensures high stability but also contributes to minimal power consumption in a compact form factor. Employing MTS with a high signal-to-noise ratio and utilizing a full bandwidth, high-speed servo feedback, we have successfully stabilized the laser frequency at the hyperfine transitions of rubidium atomic lines within the MEMS vapor cell. Furthermore, after the laser is locked, there is a significant narrowing effect on the laser linewidth. The current specifications of our compact optical frequency standard include a frequency Allan deviation of 4.8E-13@1s and the laser linewidth of only 18 kHz.
This study investigates the application of miniature quantum references within small-scale optical atomic frequency standards, utilizing a diminutive 87 Rb glass cell, dimensions of 6 mm × 6 mm × 6 mm, to establish a quantum frequency standard.By employing the transition spectrum from 5 2 S 1/2 F = 2 to 5 2 P 3/2 F 0 =3, this study successfully demonstrates the development of a compact rubidium atomic optical frequency standard via modulation transfer spectroscopy (MTS).Subsequent to frequency stabilization, the 780 nm clock laser exhibits a linewidth of 6.9 kHz, and its out-of-loop short-term stability reaches 4.1 × 10 -13 @ 1 s, as confirmed through beat frequency analysis.This research not only provides a practical blueprint for the development of small optical atomic frequency standards but also lays down essential groundwork for future advancements in chip-level optical frequency standard technologies.
Microfabricated (MEMS) alkali vapor cells are at the core of high-precision integrated atomic quantum sensors and devices, such as microwave and optical clocks, or magnetometers. The first chip-scale atomic device was a microwave atomic clock based on coherent population trapping. It has offered in its industrial and commercialized version an ultra-low size-power-instability budget, impacting a plethora of industrial and scientific applications. Nevertheless, the short-term stability of these clocks is usually limited at about 10−10 at 1 s.Hot vapor MEMS-based optical frequency standards constitute a new generation of miniaturized clocks, with enhanced stability. These references keep the benefit of using wafer-scalable and mass-producible vapor cells while preventing ultra-high vacuum technologies and laser cooling. Among the transitions explored, the 6S1/2 − 7P1/2 near-UV transition of Cs atom was used to demonstrate an optical reference with a stability of 2.1 × 10−13 at 1 s and averaging down to a few 10−14. However, this reference was based on a 5 cm-long glass-blown cell, not compliant with the advent of a fullyminiaturized and low-power optical clock.In this work, we present the characterization of sub-Doppler resonances detected in a microfabricated cell by probing, in a simple saturated absorption configuration, the Cs atom 6S1/2 – 7P1/2 transition at 459 nm. The impact of the laser intensity and cell temperature on the sub-Doppler resonance is experimentally investigated. Optimal values are identified for the development of a near-UV microcell-stabilized frequency reference. Detection noise measurements are also reported, predicting a short-term stability in the 10−13 range at 1 s. Tests of cells with embedded getters are under progress for improved purity of the cell inner atmosphere and narrowing of the resonance. Latest results will be presented at the conference.
Rydberg-atom electrometry, as an emerging cutting-edge technology, features high sensitivity, broad bandwidth, calibration-free operation, and beyond. However, until now the key atomic vapor cells used for confining electric field-sensitive Rydberg atoms nearly made with traditional glass-blown techniques, hindering the miniaturization, integration, and batch manufacturing. Here, we present the wafer-level MEMS atomic vapor cells with glass-silicon-glass sandwiched structure that are batch-manufactured for both frequency stability and electric field measurement. We use specially customized ultra-thick silicon wafers with a resistivity exceeding 10,000 Ω cm, three orders of magnitude higher than that of typical silicon, and a thickness of 6 mm, providing a 4-fold improvement in optical interrogation length. With the as-developed MEMS atomic vapor cell, we configured a high-sensitivity Rydberg-atom electrometry with the minimal detectable microwave field to be 2.8 mV/cm. This combination of miniaturization and sensitivity represents a significant advance in the state-of-the-art field of Rydberg-atom electrometry, paving the way for chip-scale Rydberg-atom electrometry and potentially opening up new applications in a wider variety of fields.
Microfabricated (MEMS) alkali vapor cells are at the core of high-precision integrated atomic quantum sensors and devices [1], such as microwave and optical clocks, or magnetometers. The first chip-scale atomic device was a microwave atomic clock based on coherent population trapping [2]. It has offered in its industrial and commercialized version an ultra-low size-power -instability budget, impacting a plethora of industrial and scientific applications. Nevertheless, the short-term stability of these clocks is usually limited at about 10−10 at 1 s. Hot vapor MEMS-based optical frequency standards constitute a new generation of miniaturized clocks, with enhanced stability. These references keep the benefit of using wafer-scalable and mass-producible vapor cells while preventing ultra-high vacuum technologies and laser cooling. Among the transitions explored, the 6S1/2 → 7P1/2 near-UV transition of Cs atom was used to demonstrate an optical reference with a stability of 2.1 × 10−13 at 1 s and averaging down to a few 10−14 [3]. However, this reference was based on a 5 cm-long glass-blown cell, not compliant with the advent of a fully-miniaturized and low-power optical clock. In this work [4], we present the characterization of sub-Doppler resonances detected in a microfabricated cell by probing, in a simple saturated absorption configuration, the Cs atom 6S1/2 → 7P1/2 transition at 459 nm. The impact of the laser intensity and cell temperature on the sub-Doppler resonance is experimentally investigated. Optimal values are identified for the development of a near-UV microcell-stabilized frequency reference. Detection noise measurements are also reported, predicting a short-term stability in the 10−13 range at 1 s. Tests of cells with embedded getters are under progress for improved purity of the cell inner atmosphere and narrowing of the resonance.
Optical wavelength standards, based on the optical transitions of atoms or molecules, provide ultra-high precision frequency references and are the core technology of next-generation optical clocks. Their stability far exceeds that of the microwave frequency range, laying the foundation for precision metrology and cutting-edge scientific research. The wavelength standard device based on the 5S1/2-5D3/2 hyperfine level two-photon transition of 87Rb atoms exhibits significant advantages such as no Doppler broadening, high signal-to-noise ratio (SNR), and potential for miniaturization and chip integration, showing important application potential in precision measurement fields like rubidium atomic clocks and optical communication. In this paper, an experimental setup for two-photon transition was constructed using an external cavity diode laser (ECDL), achieving stable locking of the 778 nm wavelength by modulating the laser current. The effects of the temperature and length of the atomic vapor cell on the blue fluorescence linewidth, SNR, and frequency stability were systematically studied, further optimizing the system. By using an atomic vapor cell designed at Brewster's angle, optical reflection loss was effectively reduced, compensating for the impact of shortened optical path on frequency stability in miniaturized atomic vapor cells. This provides new research directions and performance enhancement solutions for the miniaturization and chip integration of two-photon transition systems. In the improved system, a Brewster-angle glass vapor cell with a length of 30 mm was used and heated to 110°C, achieving a linewidth of 1.69 MHz full width at half maximum (FWHM) and a SNR of 20 dB. The system demonstrated a instability of 9.86×10-11 over a 1-second averaging time and a minimum instability of 5.79×10-11 over a 5.7-second averaging time. This achievement provides key technological support for the practical application of the next generation of miniaturized optical atomic clocks, with the potential for widespread use in portable metrology equipment and space science through integrated design and noise suppression optimization in the future.