Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Optics Express

Fast Hong-Ou-Mandel interferometry through spectrally resolved detection

Xiyue Cao, Ling Hong, Yuanyuan Chen, Lixiang Chen

Published Apr 7, 2025• 0 citations
Publisher

Abstract

Extracting information from a fast-moving object plays a crucial role in better understanding natural phenomena and exploring the unknown world. The conventional Hong-Ou-Mandel (HOM) sensor can acquire temporal information of an object using the single-shot method. However, this method is strictly limited by the temporal resolution of coincidence detection. On the other hand, implementing a suitable quantum interferometer for tracking fast-moving objects with relatively little technological effort has long been sought after, particularly for photon-sensitive biological and chemical dynamic processes. Here, we present a fast HOM interferometer based on quantum interference on a biphoton beat note and spectrally resolved detection. To verify the feasibility of our method, we demonstrate a proof-of-principle experiment that implements a fast HOM sensor for observing the track of a moving translation stage. These results may facilitate the use of quantum interference for enhancing the temporal resolution and processing speed in a fast HOM-based sensor, which has an important scientific significance in both fundamental research and applied science.

DOI
10.1364/oe.543563

Related papers

Spectrally Resolved Hong-Ou-Mandel Interferometry with Discrete Color Entanglement

Congzhen Chen, Yuanyuan Chen, Lixiang Chen

Hong-Ou-Mandel (HOM) interferometry is a powerful quantum metrology technique to reconstruct the surface-depth profile of transparent samples with complementary benefits of measurement precision and experimental robustness. It is generally assumed that a trade-off exists between the standard HOM interferometry sensitivity and its ambiguity-free dynamic range. Here we challenge this ``well-known'' assumption through the implementation of spectrally resolved HOM interferometry with discrete color entanglement, and show that the well-separated frequencies embedded in a quantum state suffices to achieve great advantages in enhancing the temporal resolution but without limiting its ambiguity-free dynamic range. Backed by the Fisher-information analysis, spectrally resolved coincidence detection is an optimal measurement strategy as it enables us to recover the quantum Cram\'er-Rao bound. These results may significantly facilitate the use of spectrally resolved quantum interference for real-time quantum information processing, such as ultrafast phase transition and spectral-temporal photography.

Physical Review Applied•May 30, 2023•18 citations

Attosecond delay metrology beyond the photon coherence time with spectrally resolved Hong-Ou-Mandel interferometry

Yingwen Zhang, Kyle Jordan, Duncan England +3 more

Hong-Ou-Mandel (HOM) interferometry enables delay estimation at the quantum precision limit but is traditionally constrained to path differences within the coherence time of the interfering photons. Here, we demonstrate single-measurement path-delay sensing at the measurement Cramer-Rao bound using spectrally resolved HOM interference, thereby removing the conventional dynamic-range limitation imposed by the photon coherence window, with no scanning required for calibration. By extracting delay information from the spectral interference fringes of spectrally entangled photon pairs, we retain near-optimal sensitivity over an operational range exceeding the photon coherence time by over two orders of magnitude. Using one million detected photon pairs, we achieve a time-delay precision of 20 attosecond (6 nm), while real-time operation (at 1 Hz) yields 330 attosecond (100 nm) precision. Because the estimator relies on fringe periodicity rather than absolute coincidence rates, the method is intrinsically robust to photon losses and variations in interference visibility, eliminating the need for recalibration. As a practical demonstration, we measure the thickness of a 300 um transmissive target with nanometer-scale precision. These results mark a significant step towards deploying quantum-limited measurements in real-world sensing applications using HOM interferometry.

quant-pharXiv:2607.16849•Jul 21, 2026•0 citations

High speed imaging of spectral-temporal correlations in Hong-Ou-Mandel interference

Yingwen Zhang, Duncan G. England, ANDREI NOMEROTSKI +1 more

In this work we demonstrate spectral-temporal correlation measurements of the Hong-Ou-Mandel (HOM) interference effect with the use of a spectrometer based on a photon-counting camera. This setup allows us to take, within seconds, spectral temporal correlation measurements on entangled photon sources with sub-nanometer spectral resolution and nanosecond timing resolution. Through post processing, we can observe the HOM behaviour for any number of spectral filters of any shape and width at any wavelength over the observable spectral range. Our setup also offers great versatility in that it is capable of operating at a wide spectral range from the visible to the near infrared and does not require a pulsed pump laser for timing purposes. This work offers the ability to gain large amounts of spectral and temporal information from a HOM interferometer quickly and efficiently and will be a very useful tool for many quantum technology applications and fundamental quantum optics research.

arXiv:2105.09431•Optics Express•Jul 17, 2021•36 citations

Real-time displacement measurement with the ultimate quantum precision through spectrally resolved two-photon interference

Yingwen Zhang, Duncan G. England, Vincenzo Tamma +2 more

We demonstrate real-time displacement measurement using spectrally resolved Hong–Ou–Mandel (HOM) interference that saturates the quantum Cram´er-Rao bound. Unlike conventional HOM-based methods, our approach does not require the displacement to be confined within the HOM dip width, typically a few tens of microns. By analyzing the periodicity of spectral interference fringes, we can maintain sensitivity at the quantum limit over displacement ranges extending to hundreds of microns. In principle, the measurable range can be extended up to the coherence length of the pump laser, limited only by the spectral resolution of the detector. We further demonstrate that real-time displacement tracking is feasible with current technology, establishing this technique as a practical and powerful tool for quantum-enhanced sensing and metrology.

Optical and Quantum Sensing and Precision Metrology II•Mar 5, 2026•0 citations

Spectrally resolved Hong–Ou–Mandel interferometry for quantum-optical coherence tomography

Pablo Yepiz-Graciano, Alí Angulo, Dorilian Lopez-Mago +2 more

In this paper, we revisit the well-known Hong–Ou–Mandel (HOM) effect in which two photons, which meet at a beamsplitter, can interfere destructively, leading to null in coincidence counts. In a standard HOM measurement, the coincidence counts across the two output ports of the beamsplitter are monitored as the temporal delay between the two photons prior to the beamsplitter is varied, resulting in the well-known HOM dip. We show, both theoretically and experimentally, that by leaving the delay fixed at a particular value while relying on spectrally resolved coincidence photon counting, we can reconstruct the HOM dip, which would have been obtained through a standard delay-scanning, non-spectrally resolved HOM measurement. We show that our numerical reconstruction procedure exhibits a novel dispersion cancellation effect, to all orders. We discuss how our present work can lead to a drastic reduction in the time required to acquire a HOM interferogram, and specifically discuss how this could be of particular importance for the implementation of efficient quantum-optical coherence tomography devices.

arXiv:2005.10177•Photonics Research•Mar 26, 2020•44 citations

Fast measurement of group index variation with optimum precision using Hong–Ou–Mandel interferometry

Sandeep Singh, Vimlesh Kumar, G. K. Samanta

Hong–Ou–Mandel (HOM) interferometry has emerged as a valuable means for quantum sensing applications, particularly in measuring physical parameters that influence the relative optical delay between photon pairs. Unlike classical techniques, HOM-based quantum sensors offer higher resolution due to the intrinsic dispersion cancellation property of correlated photon pairs. Due to the use of single photons, HOM-based quantum sensors typically involve a large integration time to acquire the signal and subsequent post-processing for high-resolution measurements, restricting their use for real-time operations. Based on our understanding of the relationship between measurement resolution and the gain medium length that produces photon pairs, we report here on the development of an HOM-based quantum sensor for high-precision group index measurements. Using a 1 mm long periodically poled KTP (PPKTP) crystal for photon-pair generation, we have measured the group index with a precision of ∼6.75×10−6 per centimeter of sample length at an integration time of 100 ms, surpassing the previous reports by 400%. Typically, the measurement range reduces with the increase in the resolution. However, using a novel scheme compensating photon delay due to group index changes stepwise with an optical delay stage, we have measured the group index variation of PPKTP crystal over a range of 3.5 × 10−3 for a temperature change from 25 to 200 °C, corresponding to an optical delay adjustment of ∼200 μm while maintaining the same precision (∼6.75×10−6 per centimeter of sample length). The current results establish the usefulness of HOM-interferometer-based quantum sensors for fast, precise, and long-range measurements in various applications, including quantum optical coherence tomography.

arXiv:2401.11853•APL Quantum•Dec 1, 2024•2 citations
Extracting information from a fast-moving object plays a crucial role in better understanding natural phenomena and exploring the unknown world. The conventional Hong-Ou-Mandel (HOM) sensor can acquire temporal information of an object using the single-shot method. However, this method is strictly limited by the temporal resolution of coincidence detection. On the other hand, implementing a suitable quantum interferometer for tracking fast-moving objects with relatively little technological effort has long been sought after, particularly for photon-sensitive biological and chemical dynamic processes. Here, we present a fast HOM interferometer based on quantum interference on a biphoton beat note and spectrally resolved detection. To verify the feasibility of our method, we demonstrate a proof-of-principle experiment that implements a fast HOM sensor for observing the track of a moving translation stage. These results may facilitate the use of quantum interference for enhancing the temporal resolution and processing speed in a fast HOM-based sensor, which has an important scientific significance in both fundamental research and applied science.
Hong-Ou-Mandel (HOM) interferometry is a powerful quantum metrology technique to reconstruct the surface-depth profile of transparent samples with complementary benefits of measurement precision and experimental robustness. It is generally assumed that a trade-off exists between the standard HOM interferometry sensitivity and its ambiguity-free dynamic range. Here we challenge this ``well-known'' assumption through the implementation of spectrally resolved HOM interferometry with discrete color entanglement, and show that the well-separated frequencies embedded in a quantum state suffices to achieve great advantages in enhancing the temporal resolution but without limiting its ambiguity-free dynamic range. Backed by the Fisher-information analysis, spectrally resolved coincidence detection is an optimal measurement strategy as it enables us to recover the quantum Cram\'er-Rao bound. These results may significantly facilitate the use of spectrally resolved quantum interference for real-time quantum information processing, such as ultrafast phase transition and spectral-temporal photography.
Hong-Ou-Mandel (HOM) interferometry enables delay estimation at the quantum precision limit but is traditionally constrained to path differences within the coherence time of the interfering photons. Here, we demonstrate single-measurement path-delay sensing at the measurement Cramer-Rao bound using spectrally resolved HOM interference, thereby removing the conventional dynamic-range limitation imposed by the photon coherence window, with no scanning required for calibration. By extracting delay information from the spectral interference fringes of spectrally entangled photon pairs, we retain near-optimal sensitivity over an operational range exceeding the photon coherence time by over two orders of magnitude. Using one million detected photon pairs, we achieve a time-delay precision of 20 attosecond (6 nm), while real-time operation (at 1 Hz) yields 330 attosecond (100 nm) precision. Because the estimator relies on fringe periodicity rather than absolute coincidence rates, the method is intrinsically robust to photon losses and variations in interference visibility, eliminating the need for recalibration. As a practical demonstration, we measure the thickness of a 300 um transmissive target with nanometer-scale precision. These results mark a significant step towards deploying quantum-limited measurements in real-world sensing applications using HOM interferometry.
In this work we demonstrate spectral-temporal correlation measurements of the Hong-Ou-Mandel (HOM) interference effect with the use of a spectrometer based on a photon-counting camera. This setup allows us to take, within seconds, spectral temporal correlation measurements on entangled photon sources with sub-nanometer spectral resolution and nanosecond timing resolution. Through post processing, we can observe the HOM behaviour for any number of spectral filters of any shape and width at any wavelength over the observable spectral range. Our setup also offers great versatility in that it is capable of operating at a wide spectral range from the visible to the near infrared and does not require a pulsed pump laser for timing purposes. This work offers the ability to gain large amounts of spectral and temporal information from a HOM interferometer quickly and efficiently and will be a very useful tool for many quantum technology applications and fundamental quantum optics research.
We demonstrate real-time displacement measurement using spectrally resolved Hong–Ou–Mandel (HOM) interference that saturates the quantum Cram´er-Rao bound. Unlike conventional HOM-based methods, our approach does not require the displacement to be confined within the HOM dip width, typically a few tens of microns. By analyzing the periodicity of spectral interference fringes, we can maintain sensitivity at the quantum limit over displacement ranges extending to hundreds of microns. In principle, the measurable range can be extended up to the coherence length of the pump laser, limited only by the spectral resolution of the detector. We further demonstrate that real-time displacement tracking is feasible with current technology, establishing this technique as a practical and powerful tool for quantum-enhanced sensing and metrology.
In this paper, we revisit the well-known Hong–Ou–Mandel (HOM) effect in which two photons, which meet at a beamsplitter, can interfere destructively, leading to null in coincidence counts. In a standard HOM measurement, the coincidence counts across the two output ports of the beamsplitter are monitored as the temporal delay between the two photons prior to the beamsplitter is varied, resulting in the well-known HOM dip. We show, both theoretically and experimentally, that by leaving the delay fixed at a particular value while relying on spectrally resolved coincidence photon counting, we can reconstruct the HOM dip, which would have been obtained through a standard delay-scanning, non-spectrally resolved HOM measurement. We show that our numerical reconstruction procedure exhibits a novel dispersion cancellation effect, to all orders. We discuss how our present work can lead to a drastic reduction in the time required to acquire a HOM interferogram, and specifically discuss how this could be of particular importance for the implementation of efficient quantum-optical coherence tomography devices.
Hong–Ou–Mandel (HOM) interferometry has emerged as a valuable means for quantum sensing applications, particularly in measuring physical parameters that influence the relative optical delay between photon pairs. Unlike classical techniques, HOM-based quantum sensors offer higher resolution due to the intrinsic dispersion cancellation property of correlated photon pairs. Due to the use of single photons, HOM-based quantum sensors typically involve a large integration time to acquire the signal and subsequent post-processing for high-resolution measurements, restricting their use for real-time operations. Based on our understanding of the relationship between measurement resolution and the gain medium length that produces photon pairs, we report here on the development of an HOM-based quantum sensor for high-precision group index measurements. Using a 1 mm long periodically poled KTP (PPKTP) crystal for photon-pair generation, we have measured the group index with a precision of ∼6.75×10−6 per centimeter of sample length at an integration time of 100 ms, surpassing the previous reports by 400%. Typically, the measurement range reduces with the increase in the resolution. However, using a novel scheme compensating photon delay due to group index changes stepwise with an optical delay stage, we have measured the group index variation of PPKTP crystal over a range of 3.5 × 10−3 for a temperature change from 25 to 200 °C, corresponding to an optical delay adjustment of ∼200 μm while maintaining the same precision (∼6.75×10−6 per centimeter of sample length). The current results establish the usefulness of HOM-interferometer-based quantum sensors for fast, precise, and long-range measurements in various applications, including quantum optical coherence tomography.