Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:2401.11853 · APL Quantum

Fast measurement of group index variation with optimum precision using Hong–Ou–Mandel interferometry

Sandeep Singh, Vimlesh Kumar, G. K. Samanta

Published Dec 1, 2024• 2 citations
arXivHTMLPDF

Abstract

Hong–Ou–Mandel (HOM) interferometry has emerged as a valuable means for quantum sensing applications, particularly in measuring physical parameters that influence the relative optical delay between photon pairs. Unlike classical techniques, HOM-based quantum sensors offer higher resolution due to the intrinsic dispersion cancellation property of correlated photon pairs. Due to the use of single photons, HOM-based quantum sensors typically involve a large integration time to acquire the signal and subsequent post-processing for high-resolution measurements, restricting their use for real-time operations. Based on our understanding of the relationship between measurement resolution and the gain medium length that produces photon pairs, we report here on the development of an HOM-based quantum sensor for high-precision group index measurements. Using a 1 mm long periodically poled KTP (PPKTP) crystal for photon-pair generation, we have measured the group index with a precision of ∼6.75×10−6 per centimeter of sample length at an integration time of 100 ms, surpassing the previous reports by 400%. Typically, the measurement range reduces with the increase in the resolution. However, using a novel scheme compensating photon delay due to group index changes stepwise with an optical delay stage, we have measured the group index variation of PPKTP crystal over a range of 3.5 × 10−3 for a temperature change from 25 to 200 °C, corresponding to an optical delay adjustment of ∼200 μm while maintaining the same precision (∼6.75×10−6 per centimeter of sample length). The current results establish the usefulness of HOM-interferometer-based quantum sensors for fast, precise, and long-range measurements in various applications, including quantum optical coherence tomography.

DOI
10.1063/5.0220993

Related papers

Near‐Video Frame Rate Quantum Sensing Using Hong–Ou–Mandel Interferometry

Sandeep Singh, Vimlesh Kumar, Varun Sharma +2 more

Abstract Hong–Ou–Mandel (HOM) interference, bunching of two indistinguishable photons on a balanced beam‐splitter, has emerged as a promising tool for quantum sensing. There is a need for wide spectral‐bandwidth photon pairs (for high‐resolution sensing) with high brightness (for fast sensing). Here, the generation of photon‐pairs with flexible spectral‐bandwidth even using single‐frequency, continuous‐wave diode laser enabling high‐precision, real‐time sensing is showed. Using 1‐mm‐long periodically‐poled KTP crystal, degenerate, photon‐pairs with spectral‐bandwidth of 163.42±1.68 nm are produced resulting in a HOM‐dip width of 4.01±0.04 m to measure a displacement of 60 nm, and sufficiently high brightness to enable the measurement of vibrations with amplitude of 205 ± 0.75 nm and frequency of 8 Hz. Fisher‐information (FI) and maximum likelihood estimation enables optical delay measurements as small as 4.97 nm with precision (Cramér–Rao bound) and accuracy of 0.89 and 0.54 nm, respectively, therefore showing HOM sensing capability for real‐time, precision‐augmented, in‐field quantum sensing applications.

arXiv:2304.13300•Advanced Quantum Technologies•Sep 21, 2023•6 citations

Attosecond delay metrology beyond the photon coherence time with spectrally resolved Hong-Ou-Mandel interferometry

Yingwen Zhang, Kyle Jordan, Duncan England +3 more

Hong-Ou-Mandel (HOM) interferometry enables delay estimation at the quantum precision limit but is traditionally constrained to path differences within the coherence time of the interfering photons. Here, we demonstrate single-measurement path-delay sensing at the measurement Cramer-Rao bound using spectrally resolved HOM interference, thereby removing the conventional dynamic-range limitation imposed by the photon coherence window, with no scanning required for calibration. By extracting delay information from the spectral interference fringes of spectrally entangled photon pairs, we retain near-optimal sensitivity over an operational range exceeding the photon coherence time by over two orders of magnitude. Using one million detected photon pairs, we achieve a time-delay precision of 20 attosecond (6 nm), while real-time operation (at 1 Hz) yields 330 attosecond (100 nm) precision. Because the estimator relies on fringe periodicity rather than absolute coincidence rates, the method is intrinsically robust to photon losses and variations in interference visibility, eliminating the need for recalibration. As a practical demonstration, we measure the thickness of a 300 um transmissive target with nanometer-scale precision. These results mark a significant step towards deploying quantum-limited measurements in real-world sensing applications using HOM interferometry.

quant-pharXiv:2607.16849•Jul 21, 2026•0 citations

Variation of the Hong-Ou-Mandel interference dip with crystal length

Sandeep Singh, Varun Sharma, Vimlesh Kumar +1 more

Two-photon interference, commonly known as Hong-Ou-Mandel (HOM) interference [1] , has attracted a great deal of interest in quantum sensing, including the precision timing measurements [2] and quantum optical coherence tomography [3] . While the dip of the HOM interference is the direct measure of the purity of the single-photon, the width of the HOM dip relates to the coherence time of the interfering photons. The broad consensus for using the HOM interferometer for sensing application remained the HOM dip width as the limiting factor for the precision measurements. As a consequence, the ultra-broadband photon sources have long been hailed as a vital prerequisite for ultra-precise HOM interferometry. Here, we have studied the variation in the width of the HOM dip with the crystal length for the continuous-wave pump laser and measured the HOM dip as low as 8.2 ± 0.2 µm corresponding to the spectral width of the single-photon source of 79.6±1.9 nm useful for sensitive sensing applications.

Conference on Lasers and Electro-Optics Europe & European Quantum Electronics Conference (CLEO/Europe-EQEC)•Jun 21, 2021•1 citation

Quantum Imaging of Birefringent Samples using Hong-Ou-Mandel Interference

Carolina Gonçalves, Tiago D. Ferreira, Catarina S. Monteiro +1 more

Two-photon interference in a Hong-Ou-Mandel (HOM) interferometer can be used as a quantum sensing mechanism due to the sensitivity of the interference dip to perturbations of the photon indistinguishability. In particular, recent works have generalized this concept to microscopy setups, but the sensitivity to optical path differences constrains its application to samples with thickness variation typically below a few micrometers if tracking changes in the coincidences at a fixed delay. Extending the concept to polarization microscopy and circumventing this limitation, this manuscript explores the use of a narrowband photon pair source with coherence length >1 mm to broaden the HOM dip. Thus, realistic sample-thickness variations introduce negligible temporal distinguishability, and changes in coincidence rate at the dip centre are then dominated by sample-induced polarization effects. To compute the polarization rotation, we develop a statistical model for the interferometer, derive the Fisher information, and establish a maximum-likelihood estimator for the local fast-axis angle. Recording dip and baseline frames at each sample position via raster scanning, the experimental results validate the framework, agreeing with classical polarized-intensity images while demonstrating operation at a maximum-precision regime and insensitiveness to layer thickness. Overall, the approach enclosed provides a quantum-based quantitative imaging of birefringent structures, which can motivate further advantageous applications, including enhanced signal-to-noise ratio and lower damage imaging of photosensitive samples.

quant-pharXiv:2512.19637•Dec 23, 2025•0 citations

Quantum imaging of the fast-axis angle using Hong–Ou–Mandel interference

Carolina Gonçalves, Tiago D. Ferreira, Catarina S. Monteiro +1 more

Two-photon interference in a Hong–Ou–Mandel (HOM) interferometer can be used as a quantum sensing mechanism due to the sensitivity of the interference dip to perturbations of the photon indistinguishability. In particular, recent studies have generalized this concept to microscopy setups, but the sensitivity to optical path differences constrains its application to samples with thickness variation typically below a few micrometers if tracking changes in the coincidences at a fixed delay. Extending the concept to polarization microscopy and circumventing this limitation, this manuscript explores the use of a narrowband photon pair source with coherence length >1 mm to broaden the HOM dip. Thus, realistic sample-thickness variations introduce negligible temporal distinguishability, and changes in coincidence rate at the dip center are then dominated by sample-induced polarization effects. To compute the polarization rotation, we develop a statistical model for the interferometer, derive the Fisher information, and establish a maximum-likelihood estimator for the local fast-axis angle. Recording dip and baseline frames at each sample position via raster scanning, the experimental results validate the framework, agreeing with classical polarized-intensity images while demonstrating operation close to the maximum-precision regime allowed by the statistical model and insensitivity to layer thickness. Overall, this proof-of-concept demonstrates thickness-insensitive quantum mapping of the local fast-axis angle, which may motivate future developments toward more comprehensive birefringence characterization and low-damage imaging of photosensitive samples, while the present proof-of-concept focuses on the half-wave-like regime, where the local fast-axis angle can be estimated with a single-parameter model.

APL Photonics•Jun 1, 2026•0 citations

High precision metrology from the fisher information of a Hong-Ou-Mandel interferometer

Ashley Lyons, George C. Knee, Eliot Bolduc +4 more

Quantum interference forces two indistinguishable input photons to depart a beamsplitter in the same (of two possible) spatial output modes; this is known as the Hong-Ou-Mandel (HOM) effect. It provides a quantitative way of measuring the distinguishability between two photons and also has been utilised to determine their relative temporal delays [1, 2]. HOM interferometry offers numerous advantages over its classical counterpart, most importantly it lacks any dependence on the phase of the photons and therefore can potentially provide reliable measurements in environments where the phase is unstable. To date there have been very few investigations on the precision that is achievable with HOM interferometry. Experiments with collinear geometries have yielded sensitivities as low as 0.1fs however these approaches are limited to measurements of birefringence and other polarisation dependent effects [3, 4], as the precision derives from the inherently stable shared path of the photon pairs. Typical non-shared path HOM interferometers exhibit resolution of roughly 1–3 fs (0.3–1 μm).

Conference on Lasers and Electro-Optics Europe & European Quantum Electronics Conference (CLEO/Europe-EQEC)•Jun 1, 2017•0 citations
Hong–Ou–Mandel (HOM) interferometry has emerged as a valuable means for quantum sensing applications, particularly in measuring physical parameters that influence the relative optical delay between photon pairs. Unlike classical techniques, HOM-based quantum sensors offer higher resolution due to the intrinsic dispersion cancellation property of correlated photon pairs. Due to the use of single photons, HOM-based quantum sensors typically involve a large integration time to acquire the signal and subsequent post-processing for high-resolution measurements, restricting their use for real-time operations. Based on our understanding of the relationship between measurement resolution and the gain medium length that produces photon pairs, we report here on the development of an HOM-based quantum sensor for high-precision group index measurements. Using a 1 mm long periodically poled KTP (PPKTP) crystal for photon-pair generation, we have measured the group index with a precision of ∼6.75×10−6 per centimeter of sample length at an integration time of 100 ms, surpassing the previous reports by 400%. Typically, the measurement range reduces with the increase in the resolution. However, using a novel scheme compensating photon delay due to group index changes stepwise with an optical delay stage, we have measured the group index variation of PPKTP crystal over a range of 3.5 × 10−3 for a temperature change from 25 to 200 °C, corresponding to an optical delay adjustment of ∼200 μm while maintaining the same precision (∼6.75×10−6 per centimeter of sample length). The current results establish the usefulness of HOM-interferometer-based quantum sensors for fast, precise, and long-range measurements in various applications, including quantum optical coherence tomography.
Abstract Hong–Ou–Mandel (HOM) interference, bunching of two indistinguishable photons on a balanced beam‐splitter, has emerged as a promising tool for quantum sensing. There is a need for wide spectral‐bandwidth photon pairs (for high‐resolution sensing) with high brightness (for fast sensing). Here, the generation of photon‐pairs with flexible spectral‐bandwidth even using single‐frequency, continuous‐wave diode laser enabling high‐precision, real‐time sensing is showed. Using 1‐mm‐long periodically‐poled KTP crystal, degenerate, photon‐pairs with spectral‐bandwidth of 163.42±1.68 nm are produced resulting in a HOM‐dip width of 4.01±0.04 m to measure a displacement of 60 nm, and sufficiently high brightness to enable the measurement of vibrations with amplitude of 205 ± 0.75 nm and frequency of 8 Hz. Fisher‐information (FI) and maximum likelihood estimation enables optical delay measurements as small as 4.97 nm with precision (Cramér–Rao bound) and accuracy of 0.89 and 0.54 nm, respectively, therefore showing HOM sensing capability for real‐time, precision‐augmented, in‐field quantum sensing applications.
Hong-Ou-Mandel (HOM) interferometry enables delay estimation at the quantum precision limit but is traditionally constrained to path differences within the coherence time of the interfering photons. Here, we demonstrate single-measurement path-delay sensing at the measurement Cramer-Rao bound using spectrally resolved HOM interference, thereby removing the conventional dynamic-range limitation imposed by the photon coherence window, with no scanning required for calibration. By extracting delay information from the spectral interference fringes of spectrally entangled photon pairs, we retain near-optimal sensitivity over an operational range exceeding the photon coherence time by over two orders of magnitude. Using one million detected photon pairs, we achieve a time-delay precision of 20 attosecond (6 nm), while real-time operation (at 1 Hz) yields 330 attosecond (100 nm) precision. Because the estimator relies on fringe periodicity rather than absolute coincidence rates, the method is intrinsically robust to photon losses and variations in interference visibility, eliminating the need for recalibration. As a practical demonstration, we measure the thickness of a 300 um transmissive target with nanometer-scale precision. These results mark a significant step towards deploying quantum-limited measurements in real-world sensing applications using HOM interferometry.
Two-photon interference, commonly known as Hong-Ou-Mandel (HOM) interference [1] , has attracted a great deal of interest in quantum sensing, including the precision timing measurements [2] and quantum optical coherence tomography [3] . While the dip of the HOM interference is the direct measure of the purity of the single-photon, the width of the HOM dip relates to the coherence time of the interfering photons. The broad consensus for using the HOM interferometer for sensing application remained the HOM dip width as the limiting factor for the precision measurements. As a consequence, the ultra-broadband photon sources have long been hailed as a vital prerequisite for ultra-precise HOM interferometry. Here, we have studied the variation in the width of the HOM dip with the crystal length for the continuous-wave pump laser and measured the HOM dip as low as 8.2 ± 0.2 µm corresponding to the spectral width of the single-photon source of 79.6±1.9 nm useful for sensitive sensing applications.
Two-photon interference in a Hong-Ou-Mandel (HOM) interferometer can be used as a quantum sensing mechanism due to the sensitivity of the interference dip to perturbations of the photon indistinguishability. In particular, recent works have generalized this concept to microscopy setups, but the sensitivity to optical path differences constrains its application to samples with thickness variation typically below a few micrometers if tracking changes in the coincidences at a fixed delay. Extending the concept to polarization microscopy and circumventing this limitation, this manuscript explores the use of a narrowband photon pair source with coherence length >1 mm to broaden the HOM dip. Thus, realistic sample-thickness variations introduce negligible temporal distinguishability, and changes in coincidence rate at the dip centre are then dominated by sample-induced polarization effects. To compute the polarization rotation, we develop a statistical model for the interferometer, derive the Fisher information, and establish a maximum-likelihood estimator for the local fast-axis angle. Recording dip and baseline frames at each sample position via raster scanning, the experimental results validate the framework, agreeing with classical polarized-intensity images while demonstrating operation at a maximum-precision regime and insensitiveness to layer thickness. Overall, the approach enclosed provides a quantum-based quantitative imaging of birefringent structures, which can motivate further advantageous applications, including enhanced signal-to-noise ratio and lower damage imaging of photosensitive samples.
Two-photon interference in a Hong–Ou–Mandel (HOM) interferometer can be used as a quantum sensing mechanism due to the sensitivity of the interference dip to perturbations of the photon indistinguishability. In particular, recent studies have generalized this concept to microscopy setups, but the sensitivity to optical path differences constrains its application to samples with thickness variation typically below a few micrometers if tracking changes in the coincidences at a fixed delay. Extending the concept to polarization microscopy and circumventing this limitation, this manuscript explores the use of a narrowband photon pair source with coherence length >1 mm to broaden the HOM dip. Thus, realistic sample-thickness variations introduce negligible temporal distinguishability, and changes in coincidence rate at the dip center are then dominated by sample-induced polarization effects. To compute the polarization rotation, we develop a statistical model for the interferometer, derive the Fisher information, and establish a maximum-likelihood estimator for the local fast-axis angle. Recording dip and baseline frames at each sample position via raster scanning, the experimental results validate the framework, agreeing with classical polarized-intensity images while demonstrating operation close to the maximum-precision regime allowed by the statistical model and insensitivity to layer thickness. Overall, this proof-of-concept demonstrates thickness-insensitive quantum mapping of the local fast-axis angle, which may motivate future developments toward more comprehensive birefringence characterization and low-damage imaging of photosensitive samples, while the present proof-of-concept focuses on the half-wave-like regime, where the local fast-axis angle can be estimated with a single-parameter model.
Quantum interference forces two indistinguishable input photons to depart a beamsplitter in the same (of two possible) spatial output modes; this is known as the Hong-Ou-Mandel (HOM) effect. It provides a quantitative way of measuring the distinguishability between two photons and also has been utilised to determine their relative temporal delays [1, 2]. HOM interferometry offers numerous advantages over its classical counterpart, most importantly it lacks any dependence on the phase of the photons and therefore can potentially provide reliable measurements in environments where the phase is unstable. To date there have been very few investigations on the precision that is achievable with HOM interferometry. Experiments with collinear geometries have yielded sensitivities as low as 0.1fs however these approaches are limited to measurements of birefringence and other polarisation dependent effects [3, 4], as the precision derives from the inherently stable shared path of the photon pairs. Typical non-shared path HOM interferometers exhibit resolution of roughly 1–3 fs (0.3–1 μm).