Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Conference on Lasers and Electro-Optics Europe & European Quantum Electronics Conference (CLEO/Europe-EQEC)

High precision metrology from the fisher information of a Hong-Ou-Mandel interferometer

Ashley Lyons, George C. Knee, Eliot Bolduc, Thomas Roger, Jonathan Leach, Erik Ganger, Daniele Faccio

Published Jun 1, 2017• 0 citations
Publisher

Abstract

Quantum interference forces two indistinguishable input photons to depart a beamsplitter in the same (of two possible) spatial output modes; this is known as the Hong-Ou-Mandel (HOM) effect. It provides a quantitative way of measuring the distinguishability between two photons and also has been utilised to determine their relative temporal delays [1, 2]. HOM interferometry offers numerous advantages over its classical counterpart, most importantly it lacks any dependence on the phase of the photons and therefore can potentially provide reliable measurements in environments where the phase is unstable. To date there have been very few investigations on the precision that is achievable with HOM interferometry. Experiments with collinear geometries have yielded sensitivities as low as 0.1fs however these approaches are limited to measurements of birefringence and other polarisation dependent effects [3, 4], as the precision derives from the inherently stable shared path of the photon pairs. Typical non-shared path HOM interferometers exhibit resolution of roughly 1–3 fs (0.3–1 μm).

DOI
10.1109/cleoe-eqec.2017.8087362

Related papers

Sample-half-inserted quantum interferometer

Wei Li, Tao Xie, Yu-Hang Luo +11 more

Quantum technologies have been widely recognized as unprecedented opportunities for ultra-high precision metrology. As a celebrated example in modern quantum optics, the Hong-Ou-Mandel (HOM) interferometer is well-known for enabling temporal resolutions on the attosecond scale. However, the relatively low Fisher information per trial in ordinary HOM measurements typically necessitates tens of thousands of repetitions to achieve such precision. Here, we propose and demonstrate a sample-half-inserted HOM (SHOM) interferometer, which enhances the Fisher information by five orders of magnitude in a single interference event. By introducing an asymmetric photon-sample interaction, the SHOM configuration produces a distinctive dip-bump-dip interference structure, converting what was previously viewed as an artifact into a helpful metrological resource. Experimentally, we measured the optical path difference with an average precision of 4.09 nm (13.63 as) and an average accuracy of 1.22 nm (4.07 as) using $O(10^7)$ photons. Our results establish SHOM interferometry as an efficient phase-insensitive approach, not only paving the way toward practical quantum-enhanced thickness measurement for transparent materials, but also serving as an elegant strategy to improve the performance of various quantum devices.

quant-pharXiv:2608.03622•Physical Review Letters•Aug 5, 2026•3 citations

The non-local Hong-Ou-Mandel effect

Yuki Kodama, Jonte R. Hance, Holger F. Hofmann

Two-photon interference effects arise because photons are indistinguishable particles. In the wellknown Hong-Ou-Mandel (HOM) effect, the transmission of two photons at a beam splitter interferes destructively with the reflection of both photons, requiring both photons to "bunch up" by leaving the beam splitter on the same side. Here, we show that the interference between locally propagating photons and photons exchanged by a mode swap can be implemented by post-selecting spatially separated photon outputs of a four-path interferometer. Even though the photons detected at spatially separated locations must have travelled along paths that never met up at the same beam splitter, the Hong-Ou-Mandel effect can be observed in correlations between the output ports that originate from the association of detection events with non-local output modes defined by the two single photon inputs. Local phase shifts can be used to map out non-classical correlations between the photons detected at different output locations, clarifying the role of linear optics in generating entanglement between spatially separated photons. Our work thus establishes a fundamental relation between multiphoton interference and entanglement, opening the door to new possibilities in optical quantum technologies.

quant-pharXiv:2604.10886•Apr 14, 2026•0 citations

Quantum Imaging of Birefringent Samples using Hong-Ou-Mandel Interference

Carolina Gonçalves, Tiago D. Ferreira, Catarina S. Monteiro +1 more

Two-photon interference in a Hong-Ou-Mandel (HOM) interferometer can be used as a quantum sensing mechanism due to the sensitivity of the interference dip to perturbations of the photon indistinguishability. In particular, recent works have generalized this concept to microscopy setups, but the sensitivity to optical path differences constrains its application to samples with thickness variation typically below a few micrometers if tracking changes in the coincidences at a fixed delay. Extending the concept to polarization microscopy and circumventing this limitation, this manuscript explores the use of a narrowband photon pair source with coherence length >1 mm to broaden the HOM dip. Thus, realistic sample-thickness variations introduce negligible temporal distinguishability, and changes in coincidence rate at the dip centre are then dominated by sample-induced polarization effects. To compute the polarization rotation, we develop a statistical model for the interferometer, derive the Fisher information, and establish a maximum-likelihood estimator for the local fast-axis angle. Recording dip and baseline frames at each sample position via raster scanning, the experimental results validate the framework, agreeing with classical polarized-intensity images while demonstrating operation at a maximum-precision regime and insensitiveness to layer thickness. Overall, the approach enclosed provides a quantum-based quantitative imaging of birefringent structures, which can motivate further advantageous applications, including enhanced signal-to-noise ratio and lower damage imaging of photosensitive samples.

quant-pharXiv:2512.19637•Dec 23, 2025•0 citations

Attosecond-resolution Hong-Ou-Mandel interferometry

Ashley Lyons, George C. Knee, Eliot Bolduc +4 more

When two indistinguishable photons are each incident on separate input ports of a beamsplitter, they "bunch" deterministically, exiting via the same port as a direct consequence of their bosonic nature. This two-photon interference effect has long-held the potential for application in precision measurement of time delays, such as those induced by transparent specimens with unknown thickness profiles. However, the technique has never achieved resolutions significantly better than the few-femtosecond (micrometer) scale other than in a common-path geometry that severely limits applications. We develop the precision of Hong-Ou-Mandel interferometry toward the ultimate limits dictated by statistical estimation theory, achieving few-attosecond (or nanometer path length) scale resolutions in a dual-arm geometry, thus providing access to length scales pertinent to cell biology and monoatomic layer two-dimensional materials.

arXiv:1708.08351•Science Advances•May 4, 2018•205 citations

Beyond coincidence in Hong-Ou-Mandel interferometry

Hannah Scott, Dominic Branford, Niclas Westerberg +2 more

The Hong-Ou-Mandel effect provides a mechanism to determine the distinguishability of a photon pair by measuring the bunching rates of two photons interfering at a beam splitter. Of particular interest is the distinguishability in time, which can be used to probe a time delay. Photon detectors themselves give some timing information, however, while that resolution may dwarf that of an interferometric technique, typical analyses reduce the interference to a binary event, neglecting temporal information in the detector. By modeling detectors with number and temporal resolution we demonstrate a greater precision than coincidence rates or temporal data alone afford. Moreover, the additional information can allow simultaneous estimation of a time delay alongside calibration parameters, opening up the possibility of calibration-free protocols and approaching the precision of the quantum Cram\'er-Rao bound.

arXiv:2005.14696•Physical Review A•Sep 10, 2020•23 citations

Dual wavelength Hong-Ou-Mandel imaging

Ashley Lyons, Khales Kassem, Daniele Faccio +1 more

Hong-Ou-Mandel (HOM) interferometry, manifesting as photon bunching at a beamsplitter, can provide high precision optical path length sensing yet is robust to phase noise and immune to phase-wrapping. In this work we demonstrate how the sensitivity of HOM based imaging can be enhanced using dual wavelength illumination whilst maintaining its high level of robustness. We observe a beating in the second order correlation function due to the interference between the two wavelengths bands with a periodicity determined by the wavelength separation. These small-scale features can be used to precisely determine optical path length at the nanometre scale whilst a coarse (micron scale) estimation can be obtained by measuring only one of the bands.

Quantitative Phase Imaging•Mar 12, 2024•0 citations
Quantum interference forces two indistinguishable input photons to depart a beamsplitter in the same (of two possible) spatial output modes; this is known as the Hong-Ou-Mandel (HOM) effect. It provides a quantitative way of measuring the distinguishability between two photons and also has been utilised to determine their relative temporal delays [1, 2]. HOM interferometry offers numerous advantages over its classical counterpart, most importantly it lacks any dependence on the phase of the photons and therefore can potentially provide reliable measurements in environments where the phase is unstable. To date there have been very few investigations on the precision that is achievable with HOM interferometry. Experiments with collinear geometries have yielded sensitivities as low as 0.1fs however these approaches are limited to measurements of birefringence and other polarisation dependent effects [3, 4], as the precision derives from the inherently stable shared path of the photon pairs. Typical non-shared path HOM interferometers exhibit resolution of roughly 1–3 fs (0.3–1 μm).
Quantum technologies have been widely recognized as unprecedented opportunities for ultra-high precision metrology. As a celebrated example in modern quantum optics, the Hong-Ou-Mandel (HOM) interferometer is well-known for enabling temporal resolutions on the attosecond scale. However, the relatively low Fisher information per trial in ordinary HOM measurements typically necessitates tens of thousands of repetitions to achieve such precision. Here, we propose and demonstrate a sample-half-inserted HOM (SHOM) interferometer, which enhances the Fisher information by five orders of magnitude in a single interference event. By introducing an asymmetric photon-sample interaction, the SHOM configuration produces a distinctive dip-bump-dip interference structure, converting what was previously viewed as an artifact into a helpful metrological resource. Experimentally, we measured the optical path difference with an average precision of 4.09 nm (13.63 as) and an average accuracy of 1.22 nm (4.07 as) using O(107)O(10^7)O(107) photons. Our results establish SHOM interferometry as an efficient phase-insensitive approach, not only paving the way toward practical quantum-enhanced thickness measurement for transparent materials, but also serving as an elegant strategy to improve the performance of various quantum devices.
Two-photon interference effects arise because photons are indistinguishable particles. In the wellknown Hong-Ou-Mandel (HOM) effect, the transmission of two photons at a beam splitter interferes destructively with the reflection of both photons, requiring both photons to "bunch up" by leaving the beam splitter on the same side. Here, we show that the interference between locally propagating photons and photons exchanged by a mode swap can be implemented by post-selecting spatially separated photon outputs of a four-path interferometer. Even though the photons detected at spatially separated locations must have travelled along paths that never met up at the same beam splitter, the Hong-Ou-Mandel effect can be observed in correlations between the output ports that originate from the association of detection events with non-local output modes defined by the two single photon inputs. Local phase shifts can be used to map out non-classical correlations between the photons detected at different output locations, clarifying the role of linear optics in generating entanglement between spatially separated photons. Our work thus establishes a fundamental relation between multiphoton interference and entanglement, opening the door to new possibilities in optical quantum technologies.
Two-photon interference in a Hong-Ou-Mandel (HOM) interferometer can be used as a quantum sensing mechanism due to the sensitivity of the interference dip to perturbations of the photon indistinguishability. In particular, recent works have generalized this concept to microscopy setups, but the sensitivity to optical path differences constrains its application to samples with thickness variation typically below a few micrometers if tracking changes in the coincidences at a fixed delay. Extending the concept to polarization microscopy and circumventing this limitation, this manuscript explores the use of a narrowband photon pair source with coherence length >1 mm to broaden the HOM dip. Thus, realistic sample-thickness variations introduce negligible temporal distinguishability, and changes in coincidence rate at the dip centre are then dominated by sample-induced polarization effects. To compute the polarization rotation, we develop a statistical model for the interferometer, derive the Fisher information, and establish a maximum-likelihood estimator for the local fast-axis angle. Recording dip and baseline frames at each sample position via raster scanning, the experimental results validate the framework, agreeing with classical polarized-intensity images while demonstrating operation at a maximum-precision regime and insensitiveness to layer thickness. Overall, the approach enclosed provides a quantum-based quantitative imaging of birefringent structures, which can motivate further advantageous applications, including enhanced signal-to-noise ratio and lower damage imaging of photosensitive samples.
When two indistinguishable photons are each incident on separate input ports of a beamsplitter, they "bunch" deterministically, exiting via the same port as a direct consequence of their bosonic nature. This two-photon interference effect has long-held the potential for application in precision measurement of time delays, such as those induced by transparent specimens with unknown thickness profiles. However, the technique has never achieved resolutions significantly better than the few-femtosecond (micrometer) scale other than in a common-path geometry that severely limits applications. We develop the precision of Hong-Ou-Mandel interferometry toward the ultimate limits dictated by statistical estimation theory, achieving few-attosecond (or nanometer path length) scale resolutions in a dual-arm geometry, thus providing access to length scales pertinent to cell biology and monoatomic layer two-dimensional materials.
The Hong-Ou-Mandel effect provides a mechanism to determine the distinguishability of a photon pair by measuring the bunching rates of two photons interfering at a beam splitter. Of particular interest is the distinguishability in time, which can be used to probe a time delay. Photon detectors themselves give some timing information, however, while that resolution may dwarf that of an interferometric technique, typical analyses reduce the interference to a binary event, neglecting temporal information in the detector. By modeling detectors with number and temporal resolution we demonstrate a greater precision than coincidence rates or temporal data alone afford. Moreover, the additional information can allow simultaneous estimation of a time delay alongside calibration parameters, opening up the possibility of calibration-free protocols and approaching the precision of the quantum Cram\'er-Rao bound.
Hong-Ou-Mandel (HOM) interferometry, manifesting as photon bunching at a beamsplitter, can provide high precision optical path length sensing yet is robust to phase noise and immune to phase-wrapping. In this work we demonstrate how the sensitivity of HOM based imaging can be enhanced using dual wavelength illumination whilst maintaining its high level of robustness. We observe a beating in the second order correlation function due to the interference between the two wavelengths bands with a periodicity determined by the wavelength separation. These small-scale features can be used to precisely determine optical path length at the nanometre scale whilst a coarse (micron scale) estimation can be obtained by measuring only one of the bands.