Laser & Optoelectronics Progress

基于CPT效应矢量磁场测量技术发展现状与展望

王学锋 Wang Xuefeng, 刘崇泰 Liu Chongtai, 卢向东 Lu Xiangdong, 李建军 Li Jianjun, 邓意成 Deng Yicheng, 徐强锋 Xu Qiangfeng

Published Jan 1, 2025• 1 citation
Publisher

Abstract

High-precision measurement of geomagnetic field is important in many applications, including geology and geomagnetic-matching navigation. A single atomic magnetometer cannot simultaneously realize high-precision measurements of the magnitude and direction of geomagnetic field. A promising solution of magnetic field vector measurement is a type of atomic magnetometer based on coherent population trapping (CPT) effect. Firstly, the principle of measuring magnetic field vector based on the CPT effect is introduced. Then, two types of methods for measuring magnetic field vector with or without auxiliary coils are discussed, and three key technologies for measuring magnetic field vector based on CPT effect are discussed, including accurate measurement of gradient magnetic field, continuous real-time measurement of magnetic field vector, closed-loop control of measurement system, and interference suppression. Finally, the application prospects of CPT-based magnetic field vector measurement methods are explored from three aspects: calibration and compensation of heading error, reduction of the effect of magnetic field gradient with micro-electromechanical system atomic vapor cell technology, and elimination of optical power fluctuations with an optical power compensation algorithm.

DOI
10.3788/lop240673

Related papers

Vector magnetometer based on the effect of coherent population trapping

Valeriy Andryushkov, Daba A. Radnatarov, Sergey M Kobtsev

The method is presented for converting a coherent population trapping (CPT) atomic clock into a CPT vector (compass-) magnetometer without mechanically moving parts through a relatively simple add-on. The system of 3D Helmholtz coils was used for compensation of the external magnetic field, allowing measurement of both strength and direction of a magnetic field at the sensitivity level of s u b − n T / H z 1 / 2 within a 10-Hz bandwidth. Angular resolution of the developed vector magnetometer amounts to about 1 0 − 2 degrees.

Applied Optics•Apr 21, 2022•35 citations

Four-peak tracking autonomous omni-directional CPT atomic magnetometer

XueFeng WANG, YiCheng DENG, XiangDong LU +2 more

Omni-directional measurement of the geomagnetic field in satellites is necessary. Coherent population trapping (CPT) atomic magnetometer is theoretically capable of omni-directional measurement of magnetic fields, but it requires a reference signal in the direction of the magnetic field. To solve this problem, a new control method was proposed in this paper to trap four CPT signals. First, the control system demodulates the CPT differential signals with n=–3, n=–2, n=+2, and n=+3 by a time-division frequency modulation. Second, these CPT differential signals are fused to obtain two new feedback signals: one feedback signal used to calibrate the central frequency between n=±2 or n=±3, and the other feedback signal used to adjust the frequency between the central frequency and the CPT signals with n=±2 or n=±3. When a change in the magnetic field direction causes CPT signals with n=±2 or ±3 to disappear, the two feedback signals remain unaffected. Therefore, this control method does not require a fluxgate magnetometer to provide the magnetic field direction for mode switching and can obtain continuous magnetic data without losing lock in the range of 0°–360°. This means that it is an autonomous omni-directional CPT atomic magnetometer.

Zhongguo kexue. Wulixue Lixue Tianwenxue•Sep 23, 2024•0 citations

原子磁力仪的研究进展与发展趋势

宗昕冉 Zong Xinran, 陈海军 Chen Haijun

As instruments for accurately measuring magnetic fields, atomic magnetometers play a significant role in various fields, including fundamental physics, earth sciences, biomedicine, and national defense. This study presents a comprehensive review of the technical development of atomic magnetometers, covering their major categories and basic features, while providing a detailed discussion of the current research status and development trends of alkali metal optical pumping magnetometers, coherent population trapping atomic magnetometers, spin exchange relaxation-free atomic magnetometers, and nonlinear magneto-optical rotation atomic magnetometers. The study first classifies magnetometers based on classical physics principles and quantum effects. This is followed by an in-depth discussion of the working principles, sensitivity, dynamic range, bandwidth, and other key performance indicators of the four types of quantum-effect atomic magnetometers. The study then describes their advantages and challenges under various application scenarios. Finally, future developmental directions for magnetometer technologies are considered. These include miniaturization, integration, enhancement of vector magnetic field measurement capabilities, and potential applications in biomedical imaging and geophysical exploration.

Laser & Optoelectronics Progress•Jan 1, 2025•1 citation

Nonlinear Zeeman Effect Suppression for CPT Atom Magnetometers

Qiuchang Jia, Feifan Yang, Xianyang Huo +2 more

Geomagnetic measurement relies on high-sensitivity sensors, where coherent population trapping (CPT) magnetometers show promise due to advantages such as no dead zone and miniaturization capability. However, their sensitivity in geomagnetic environments is limited by the nonlinear Zeeman effect. This article establishes a magnetic field measurement model that suppresses this effect by utilizing the linear relationship between the external magnetic field and the frequency difference of the two peaks resulting from the resplitting of the zeroth-order CPT resonance. Theoretical analysis confirms that, at geomagnetic field strength, the frequency difference maintains a strict linear proportionality of 55.713 kHz/mT, whereas traditional methods fail due to higher order energy shifts. To enhance the weak CPT resonance, a closed-loop control system based on spontaneous fluorescence feedback was implemented, stabilizing the excited-state population via real-time laser power adjustment. Experimental results show that under closed-loop operation, the CPT signal amplitude increases approximately threefold with no significant linewidth broadening, theoretically improving sensitivity by 1.1 times, and the resplit double-peak structure is clearly observed in a geomagnetic environment. This approach provides a viable strategy for improving the sensitivity and accuracy of CPT magnetometers in geomagnetic field measurements.

IEEE Transactions on Instrumentation and Measurement•Jan 1, 2026•0 citations

High-accuracy CPT-based atomic magnetometer with compact optical and electronic architecture

Ruochen Zhang, Renfeng Dai, Hua Liu

We present a compact CPT-based atomic magnetometer utilizing a directly modulated VCSEL and phase-sensitive detection. The device achieves a static magnetic field measurement accuracy of 20 pT (1σ) with directional consistency exceeding 99.6%. Calibration using saddle and solenoidal coils yields a linear response with coil coefficients of 708.4 nT/mA and 2466.3 nT/mA, respectively, closely matching an optically pumped Mx-type magnetometer. The results validate the feasibility of portable, high-sensitivity CPT magnetometers for real-time vector magnetic field sensing.

Optics Letters•Oct 14, 2025•1 citation

Demonstration of a field-deployable vector magnetometer using synchronous coherent population trapping and feedback compensation mechanism

Renu Tripathi, G. S. Pati, Mauricio Pulido

We have developed a field-deployable vector magnetometer using a small rubidium vapor cell, which is capable of measuring the magnitude and direction of the earth's magnetic field with high accuracy and sensitivity. The magnetometer measures Larmor precession of rubidium atoms using the phenomenon, called synchronous coherent population trapping (SCPT). This gives the advantage of producing a high contrast and narrow linewidth resonance needed for measuring the magnetic field with high accuracy and sensitivity. The magnetometer exhibits sub-nT/√Hz sensitivities in measuring the field components along the three directions.

SPIE Quantum Information Science, Sensing, and Computation•Jun 7, 2024•0 citations
High-precision measurement of geomagnetic field is important in many applications, including geology and geomagnetic-matching navigation. A single atomic magnetometer cannot simultaneously realize high-precision measurements of the magnitude and direction of geomagnetic field. A promising solution of magnetic field vector measurement is a type of atomic magnetometer based on coherent population trapping (CPT) effect. Firstly, the principle of measuring magnetic field vector based on the CPT effect is introduced. Then, two types of methods for measuring magnetic field vector with or without auxiliary coils are discussed, and three key technologies for measuring magnetic field vector based on CPT effect are discussed, including accurate measurement of gradient magnetic field, continuous real-time measurement of magnetic field vector, closed-loop control of measurement system, and interference suppression. Finally, the application prospects of CPT-based magnetic field vector measurement methods are explored from three aspects: calibration and compensation of heading error, reduction of the effect of magnetic field gradient with micro-electromechanical system atomic vapor cell technology, and elimination of optical power fluctuations with an optical power compensation algorithm.
The method is presented for converting a coherent population trapping (CPT) atomic clock into a CPT vector (compass-) magnetometer without mechanically moving parts through a relatively simple add-on. The system of 3D Helmholtz coils was used for compensation of the external magnetic field, allowing measurement of both strength and direction of a magnetic field at the sensitivity level of s u b − n T / H z 1 / 2 within a 10-Hz bandwidth. Angular resolution of the developed vector magnetometer amounts to about 1 0 − 2 degrees.
Omni-directional measurement of the geomagnetic field in satellites is necessary. Coherent population trapping (CPT) atomic magnetometer is theoretically capable of omni-directional measurement of magnetic fields, but it requires a reference signal in the direction of the magnetic field. To solve this problem, a new control method was proposed in this paper to trap four CPT signals. First, the control system demodulates the CPT differential signals with n=–3, n=–2, n=+2, and n=+3 by a time-division frequency modulation. Second, these CPT differential signals are fused to obtain two new feedback signals: one feedback signal used to calibrate the central frequency between n=±2 or n=±3, and the other feedback signal used to adjust the frequency between the central frequency and the CPT signals with n=±2 or n=±3. When a change in the magnetic field direction causes CPT signals with n=±2 or ±3 to disappear, the two feedback signals remain unaffected. Therefore, this control method does not require a fluxgate magnetometer to provide the magnetic field direction for mode switching and can obtain continuous magnetic data without losing lock in the range of 0°–360°. This means that it is an autonomous omni-directional CPT atomic magnetometer.
As instruments for accurately measuring magnetic fields, atomic magnetometers play a significant role in various fields, including fundamental physics, earth sciences, biomedicine, and national defense. This study presents a comprehensive review of the technical development of atomic magnetometers, covering their major categories and basic features, while providing a detailed discussion of the current research status and development trends of alkali metal optical pumping magnetometers, coherent population trapping atomic magnetometers, spin exchange relaxation-free atomic magnetometers, and nonlinear magneto-optical rotation atomic magnetometers. The study first classifies magnetometers based on classical physics principles and quantum effects. This is followed by an in-depth discussion of the working principles, sensitivity, dynamic range, bandwidth, and other key performance indicators of the four types of quantum-effect atomic magnetometers. The study then describes their advantages and challenges under various application scenarios. Finally, future developmental directions for magnetometer technologies are considered. These include miniaturization, integration, enhancement of vector magnetic field measurement capabilities, and potential applications in biomedical imaging and geophysical exploration.
Geomagnetic measurement relies on high-sensitivity sensors, where coherent population trapping (CPT) magnetometers show promise due to advantages such as no dead zone and miniaturization capability. However, their sensitivity in geomagnetic environments is limited by the nonlinear Zeeman effect. This article establishes a magnetic field measurement model that suppresses this effect by utilizing the linear relationship between the external magnetic field and the frequency difference of the two peaks resulting from the resplitting of the zeroth-order CPT resonance. Theoretical analysis confirms that, at geomagnetic field strength, the frequency difference maintains a strict linear proportionality of 55.713 kHz/mT, whereas traditional methods fail due to higher order energy shifts. To enhance the weak CPT resonance, a closed-loop control system based on spontaneous fluorescence feedback was implemented, stabilizing the excited-state population via real-time laser power adjustment. Experimental results show that under closed-loop operation, the CPT signal amplitude increases approximately threefold with no significant linewidth broadening, theoretically improving sensitivity by 1.1 times, and the resplit double-peak structure is clearly observed in a geomagnetic environment. This approach provides a viable strategy for improving the sensitivity and accuracy of CPT magnetometers in geomagnetic field measurements.
We present a compact CPT-based atomic magnetometer utilizing a directly modulated VCSEL and phase-sensitive detection. The device achieves a static magnetic field measurement accuracy of 20 pT (1σ) with directional consistency exceeding 99.6%. Calibration using saddle and solenoidal coils yields a linear response with coil coefficients of 708.4 nT/mA and 2466.3 nT/mA, respectively, closely matching an optically pumped Mx-type magnetometer. The results validate the feasibility of portable, high-sensitivity CPT magnetometers for real-time vector magnetic field sensing.
We have developed a field-deployable vector magnetometer using a small rubidium vapor cell, which is capable of measuring the magnitude and direction of the earth's magnetic field with high accuracy and sensitivity. The magnetometer measures Larmor precession of rubidium atoms using the phenomenon, called synchronous coherent population trapping (SCPT). This gives the advantage of producing a high contrast and narrow linewidth resonance needed for measuring the magnetic field with high accuracy and sensitivity. The magnetometer exhibits sub-nT/√Hz sensitivities in measuring the field components along the three directions.