Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Physical Review A

Suppression of systematic effects in a single-species atomic comagnetometer

Yixin Zhao, Junhe Zheng, Wei Xiao, Xiang Peng, Teng Wu, Hong Mei Guo

Published Dec 27, 2024• 2 citations
Publisher

Abstract

The atomic comagnetometer is capable of reducing the effect of magnetic-field variations through comparing the synchronous measurement results from at least two magnetometers. A new configuration of comagnetometer is based on an ensemble of identical atoms or molecules, and possesses the ability to suppress the magnetic-field-gradient-induced systematic effect. We present a comprehensive analysis on the systematic effects of a single-species cesium atomic comagnetometer. Experimental results reveal that the dominant systematic effect arises from the light shift. We propose a method to suppress the light-shift-induced systematic effect, combined with quantitative investigations on other sources of systematic effects. The optimized system is able to search for the hypothetical spin-dependent gravitational energy of a proton at a level of ${10}^{\ensuremath{-}19}$ eV.

DOI
10.1103/physreva.110.063122

Related papers

Single-Species Atomic Comagnetometer Based on Rb 87 Atoms

Zhiguo Wang, Xiang Peng, Rui Zhang +5 more

The comagnetometer has been one of the most sensitive devices with which to test new physics related to spin-dependent interactions, but the comagnetometers based on overlapping ensembles of multiple spin species usually suffer from systematic errors due to magnetic field gradients. Here, we propose a comagnetometer based on the Zeeman transitions of the dual hyperfine levels in ground-state ^{87}Rb atoms, which shows nearly negligible sensitivity to variations of laser power and frequency, magnetic field, and magnetic field gradients. We measured the hypothetical spin-dependent gravitational energy of the proton with the comagnetometer, which is smaller than 4×10^{-18} eV, comparable to the most stringent existing constraint. Through optimizing the system parameters such as cell temperature, laser power, amplitude of driving magnetic field, as well as choosing better current source, it is possible to improve the sensitivity of the comagnetometer further.

arXiv:1812.06830•Physical Review Letters•May 13, 2020•53 citations

New Classes of Systematic Effects in Gas Spin Comagnetometers

D. Sheng, Aaron Kabcenell, Michael V. Romalis

Atomic comagnetometers are widely used in precision measurements searching for spin interactions beyond the standard model. We describe a new (3)He-(129)Xe comagnetometer probed by Rb atoms and use it to identify two general classes of systematic effects in gas comagnetometers, one associated with diffusion in second-order magnetic-field gradients and another due to temperature gradients. We also develop and confirm experimentally a general and practical approach for calculating spin relaxation and frequency shifts due to arbitrary magnetic-field gradients.

arXiv:1407.4402•Physical Review Letters•Oct 16, 2014•95 citations

New Classes of Magnetic Noise Self-Compensation Effects in Atomic Comagnetometer

Yushu Qin, Zhenhan Shao, Taizhou Hong +3 more

Precision measurements of anomalous spin-dependent interactions are often hindered by magnetic noise and other magnetic systematic effects. Atomic comagnetometers use the distinct spin precession of two species and have emerged as important tools for effectively mitigating the magnetic noise. Nevertheless, the operation of existing comagnetometers is limited to very low-frequency noise commonly below 1 Hz. Here, we report a new type of atomic comagnetometer based on a magnetic noise self-compensation mechanism originating from the destructive interference between alkali-metal and noble-gas spins. Our comagnetometer employing K-^{3}He system remarkably suppresses magnetic noise exceeding 2 orders of magnitude at higher frequencies up to 160 Hz. Moreover, we discover that the capability of our comagnetometer to suppress magnetic noise is spatially dependent on the orientation of the noise and can be conveniently controlled by adjusting the applied bias magnetic field. Our findings open up new possibilities for precision measurements, including enhancing the search sensitivity of spin-dark matter particles interactions into unexplored parameter space.

Physical Review Letters•Jul 11, 2024•22 citations

Analysis and Suppression of Optical-Magnetic Misalignment in an Atomic Comagnetometer

Ze Cai, Lihong Duan, Kai Zhang +5 more

Ultrasensitive atomic comagnetometers (ACMs) are invaluable tools for both inertial measurement and fundamental physics research. However, the misalignment between the pump light and the main magnetic field affects the polarization characteristics of nuclear spins of the noble gas atoms, making it a significant source of noise. In this article, an atomic magnetometer response model with the optical-magnetic misalignment error is established, and the mechanism of the influence of optical-magnetic misalignment on nuclear spin polarization is analyzed. An in situ evaluation method and a suppression method of optical-magnetic misalignment error are proposed, and their effectiveness is verified through experiments with varying pump light incidence directions. The experimental results indicate that after optical-magnetic alignment using the proposed method, the spin polarization of the coupled atomic ensemble is enhanced by 20.7%, and the longitudinal relaxation rate of the nuclear spin is reduced by 6.9%. Additionally, the amplitude-frequency response (AFR) of the x-axis magnetic field is reduced by 33.2% at 1 Hz and by 53.1% at frequencies below 0.002 Hz. This indicates an improvement in the transverse magnetic field error suppression capability of the ACMs.

IEEE Sensors Journal•Nov 18, 2024•3 citations

Suppression of heading errors in Bell-Bloom optically pumped free-induction-decay alkali-metal atomic magnetometers

S.-Q. Liu, X.-K. Wang, Xiangdong Zhang +2 more

Heading errors of atomic magnetometers refer to the dependence of measurement results on the sensor orientation with respect to the external magnetic field. There are three main sources of such errors: the light shift effect, the linear nuclear-spin Zeeman effect, and the nonlinear Zeeman effect. In this work, we suppress the first two effects by using the Bell-Bloom optical pumping method and probe the atomic signals while the pumping beam is off, and focus on the heading error induced by nonlinear Zeeman effect while the sensor operates in the geomagnetic field range. We demonstrate several schemes to suppress this remaining heading error within 1 nT using a single magnetometer or a comagnetometer. In the magnetometer system, two schemes are developed to average out the horizontal atomic polarization in space or in time, respectively. In the comagnetometer system, we combine the simultaneously measured Larmor frequencies of two different alkali atoms to either suppress the heading error or extract the orientation of the pumping beam relative to the bias field.

arXiv:2502.13414•Physical Review A•Feb 26, 2025•6 citations

Dual-Axis Measurement and Suppression Method for Light Shift Based on a Single-Beam Compact SERF Atomic Magnetometer

Kexuan Miao, Tao Hu, Yan Chang +2 more

The light shift in a spin-exchange relaxation-free (SERF) atomic magnetometer (AM) generated by detuning of circularly polarized pump light, results in deviations of orthogonality measurement and attenuation of magnetometer response. In this paper, we propose and systematically investigate a dual-axis method to suppress light shift based on a self-developed single-beam compact SERF AM capable of measuring magnetic field components along two orthogonal sensitive axes. By sequentially observing the non-sensitive axis response and applying a magnetic field along the pump light direction, the virtual magnetic field induced by light shift is compensated and is rigorously demonstrated as a dominant component in this direction. Experimental results show a significant reduction in crosstalk between the dual sensitive axes, improving accuracy in resonant frequency determination of87Rb atoms and orthogonality evaluation of triaxial coils. Furthermore, the performance of dual-axis measurement in the SERF AM is tested, showing a more notable enhancement than that of single-axis measurement.

IEEE Sensors Journal•Jan 7, 2025•2 citations
The atomic comagnetometer is capable of reducing the effect of magnetic-field variations through comparing the synchronous measurement results from at least two magnetometers. A new configuration of comagnetometer is based on an ensemble of identical atoms or molecules, and possesses the ability to suppress the magnetic-field-gradient-induced systematic effect. We present a comprehensive analysis on the systematic effects of a single-species cesium atomic comagnetometer. Experimental results reveal that the dominant systematic effect arises from the light shift. We propose a method to suppress the light-shift-induced systematic effect, combined with quantitative investigations on other sources of systematic effects. The optimized system is able to search for the hypothetical spin-dependent gravitational energy of a proton at a level of 10\ensuremath−19{10}^{\ensuremath{-}19}10\ensuremath−19 eV.
The comagnetometer has been one of the most sensitive devices with which to test new physics related to spin-dependent interactions, but the comagnetometers based on overlapping ensembles of multiple spin species usually suffer from systematic errors due to magnetic field gradients. Here, we propose a comagnetometer based on the Zeeman transitions of the dual hyperfine levels in ground-state ^{87}Rb atoms, which shows nearly negligible sensitivity to variations of laser power and frequency, magnetic field, and magnetic field gradients. We measured the hypothetical spin-dependent gravitational energy of the proton with the comagnetometer, which is smaller than 4×10^{-18} eV, comparable to the most stringent existing constraint. Through optimizing the system parameters such as cell temperature, laser power, amplitude of driving magnetic field, as well as choosing better current source, it is possible to improve the sensitivity of the comagnetometer further.
Atomic comagnetometers are widely used in precision measurements searching for spin interactions beyond the standard model. We describe a new (3)He-(129)Xe comagnetometer probed by Rb atoms and use it to identify two general classes of systematic effects in gas comagnetometers, one associated with diffusion in second-order magnetic-field gradients and another due to temperature gradients. We also develop and confirm experimentally a general and practical approach for calculating spin relaxation and frequency shifts due to arbitrary magnetic-field gradients.
Precision measurements of anomalous spin-dependent interactions are often hindered by magnetic noise and other magnetic systematic effects. Atomic comagnetometers use the distinct spin precession of two species and have emerged as important tools for effectively mitigating the magnetic noise. Nevertheless, the operation of existing comagnetometers is limited to very low-frequency noise commonly below 1 Hz. Here, we report a new type of atomic comagnetometer based on a magnetic noise self-compensation mechanism originating from the destructive interference between alkali-metal and noble-gas spins. Our comagnetometer employing K-^{3}He system remarkably suppresses magnetic noise exceeding 2 orders of magnitude at higher frequencies up to 160 Hz. Moreover, we discover that the capability of our comagnetometer to suppress magnetic noise is spatially dependent on the orientation of the noise and can be conveniently controlled by adjusting the applied bias magnetic field. Our findings open up new possibilities for precision measurements, including enhancing the search sensitivity of spin-dark matter particles interactions into unexplored parameter space.
Ultrasensitive atomic comagnetometers (ACMs) are invaluable tools for both inertial measurement and fundamental physics research. However, the misalignment between the pump light and the main magnetic field affects the polarization characteristics of nuclear spins of the noble gas atoms, making it a significant source of noise. In this article, an atomic magnetometer response model with the optical-magnetic misalignment error is established, and the mechanism of the influence of optical-magnetic misalignment on nuclear spin polarization is analyzed. An in situ evaluation method and a suppression method of optical-magnetic misalignment error are proposed, and their effectiveness is verified through experiments with varying pump light incidence directions. The experimental results indicate that after optical-magnetic alignment using the proposed method, the spin polarization of the coupled atomic ensemble is enhanced by 20.7%, and the longitudinal relaxation rate of the nuclear spin is reduced by 6.9%. Additionally, the amplitude-frequency response (AFR) of the x-axis magnetic field is reduced by 33.2% at 1 Hz and by 53.1% at frequencies below 0.002 Hz. This indicates an improvement in the transverse magnetic field error suppression capability of the ACMs.
Heading errors of atomic magnetometers refer to the dependence of measurement results on the sensor orientation with respect to the external magnetic field. There are three main sources of such errors: the light shift effect, the linear nuclear-spin Zeeman effect, and the nonlinear Zeeman effect. In this work, we suppress the first two effects by using the Bell-Bloom optical pumping method and probe the atomic signals while the pumping beam is off, and focus on the heading error induced by nonlinear Zeeman effect while the sensor operates in the geomagnetic field range. We demonstrate several schemes to suppress this remaining heading error within 1 nT using a single magnetometer or a comagnetometer. In the magnetometer system, two schemes are developed to average out the horizontal atomic polarization in space or in time, respectively. In the comagnetometer system, we combine the simultaneously measured Larmor frequencies of two different alkali atoms to either suppress the heading error or extract the orientation of the pumping beam relative to the bias field.
The light shift in a spin-exchange relaxation-free (SERF) atomic magnetometer (AM) generated by detuning of circularly polarized pump light, results in deviations of orthogonality measurement and attenuation of magnetometer response. In this paper, we propose and systematically investigate a dual-axis method to suppress light shift based on a self-developed single-beam compact SERF AM capable of measuring magnetic field components along two orthogonal sensitive axes. By sequentially observing the non-sensitive axis response and applying a magnetic field along the pump light direction, the virtual magnetic field induced by light shift is compensated and is rigorously demonstrated as a dominant component in this direction. Experimental results show a significant reduction in crosstalk between the dual sensitive axes, improving accuracy in resonant frequency determination of87Rb atoms and orthogonality evaluation of triaxial coils. Furthermore, the performance of dual-axis measurement in the SERF AM is tested, showing a more notable enhancement than that of single-axis measurement.