IEEE Sensors Journal

Analysis and Suppression of Optical-Magnetic Misalignment in an Atomic Comagnetometer

Ze Cai, Lihong Duan, Kai Zhang, Linlin Yuan, Hang Gao, Feng Liu, Xusheng Lei, Wei Quan

Published Nov 18, 2024• 3 citations
Publisher

Abstract

Ultrasensitive atomic comagnetometers (ACMs) are invaluable tools for both inertial measurement and fundamental physics research. However, the misalignment between the pump light and the main magnetic field affects the polarization characteristics of nuclear spins of the noble gas atoms, making it a significant source of noise. In this article, an atomic magnetometer response model with the optical-magnetic misalignment error is established, and the mechanism of the influence of optical-magnetic misalignment on nuclear spin polarization is analyzed. An in situ evaluation method and a suppression method of optical-magnetic misalignment error are proposed, and their effectiveness is verified through experiments with varying pump light incidence directions. The experimental results indicate that after optical-magnetic alignment using the proposed method, the spin polarization of the coupled atomic ensemble is enhanced by 20.7%, and the longitudinal relaxation rate of the nuclear spin is reduced by 6.9%. Additionally, the amplitude-frequency response (AFR) of the x-axis magnetic field is reduced by 33.2% at 1 Hz and by 53.1% at frequencies below 0.002 Hz. This indicates an improvement in the transverse magnetic field error suppression capability of the ACMs.

DOI
10.1109/jsen.2024.3495700

Related papers

Analysis and suppression of the misalignment error for the pumping laser in the atomic comagnetometer

Jiong Huang, Wenfeng Fan, Zhuo Wang +5 more

The misalignment error of the pumping laser in the atomic comagnetometer (ACM) dramatically diminishes the efficiency of the optical pumping process (characterized by the polarization of the hybrid atomic spin ensembles containing electron spins and nuclear spins) and deteriorates the performance of the ACM (characterized by the Allan standard deviation). In this work, a steady-state response model considering the misalignment error of the pumping laser is established and an in-situ evaluation method for this error is proposed. Based on the evaluation method, the influence of this misalignment error on the pumping efficiency and the performance of the ACM is quantitatively analyzed. Furthermore, a pumping laser alignment method based on the second harmonic of a single-beam magnetometer is then proposed, whose effectiveness is verified by experiments. The experimental results show that compared to the original ACM with the severely misaligned pumping laser, the polarization of the hybrid atomic spin ensembles of the ACM with the pumping laser aligned by the proposed method is increased by about 19%, and the corresponding Allan variance at 100s is reduced by about 40%.

Optics Express•Feb 7, 2022•30 citations

Comprehensive analysis of the impact of optical magnetic misalignment on the performance of the SERF co-magnetometer

Ze Yu Cai, Lihong Duan, Shimiao Fan +2 more

The ultra-sensitive atomic co-magnetometer based on the spin-exchange relaxation-free (SERF) regime is a valuable tool for inertial measurements and fundamental physics research. However, the optical magnetic misalignment effect is a significant source of error in SERF co-magnetometers, limiting their magnetic field suppression ability and long-term stability. This paper establishes a response model of angular velocity and magnetic field for the SERF co-magnetometer. The impact of optical magnetic misalignment on the scale factor, magnetic field amplitude-frequency response, and angular velocity errors caused by magnetic noise is systematically investigated. The results indicate that the scale factor and magnetic field suppression ability decrease as the optical magnetic misalignment angle increases, while the angular velocity errors caused by magnetic noise increase as the misalignment angle increases. Finally, experimental results demonstrate that the optical-magnetic misalignment effect significantly compromises the long-term stability of SERF co-magnetometers, underscoring its substantial influence on the overall performance. This work contributes to understanding the mechanism of optical magnetic misalignment effects on the SERF co-magnetometer and enhances its performance.

Optics Express•Apr 10, 2025•4 citations

In situ decoupling of pump-induced spin polarization noise in atomic spin sensors

Dinghui Gong, Xiaofei Huang, Di Gong +5 more

In atomic spin sensors based on optical pumping, pump beam instabilities can drive atomic spin polarization fluctuations, referred to here as pump-induced spin polarization noise, which may limit sensitivity and long-term stability. Because the local pump field inside the cell can differ from that inferred from external optical diagnostics, it remains difficult to directly quantify the actual in situ spin polarization noise and to evaluate and suppress its contribution to the sensor noise floor. Here, we propose an in situ decoupling method based on spin dynamics, in which a large longitudinal detuning field suppresses magnetic field and rotation responses, while a transverse projection field converts pump-induced fluctuations in longitudinal spin polarization into a measurable transverse spin signal. Demonstrated in a K-Rb-21Ne spin exchange relaxation free (SERF) comagnetometer, the proposed method suppresses the magnetic-field response by approximately 180-fold and enhances the pump-power-noise response by approximately 380-fold, thereby enabling effective separation and evaluation of pump-induced spin polarization noise. The method employs the atomic ensemble as an in situ probe of the spin dynamic response to the local pump optical field. It enables quantitative identification of pump fluctuation associated noise and direct evaluation of optical field stability under actual operating conditions, thereby providing an experimental basis for optical field stabilization and noise suppression assessment in SERF comagnetometers and related alkali atomic spin sensors.

Applied Physics Letters•Aug 24, 2026•0 citations

Magnetic noise suppression based on mid-frequency magnetic field response in SERF atomic comagnetometers

Ze Yu Cai, Zhihong Wu, Feng Liu +4 more

The atomic comagnetometers (ACMs) based on the spin-exchange relaxation-free (SERF) regime exhibit extremely high sensitivity in angular velocity measurements, positioning them as leading candidates for next-generation precision inertial sensing. However, magnetic noise remains a significant factor that contributes significantly to long-term bias drift. Here, a comprehensive model in full-frequency band of the angular velocity measurement error induced by magnetic noise in ACMs is established. Based on the proposed model, what we believe to be a new method is proposed to reduce magnetic noise error by suppressing the magnetic field response in the mid-frequency range. After optimizing the temperature of the vapor cell to minimize the magnetic field response in the mid-frequency range, the angular velocity measurement error caused by magnetic noise was reduced by 20.4%, and the bias drift was improved by 34.8%. The theories and methods proposed in this study innovatively highlight the critical role of mid-frequency magnetic field responses in suppressing magnetic noise errors, and provide important guidance for improving bias drift in SERF ACMs.

Optics Express•Jul 14, 2025•3 citations

Analysis and Suppression for Critical Optical Nonorthogonal Noise in SERF Comagnetometers

Zitong Xu, Kai Wei, Chang Liu +6 more

Ultrasensitive atomic comagnetometers have proven to be valuable tools for precise measurement and search for new physics. Besides, comagnetometers have potential for inertial navigation and quantum information. Despite their great potential, sensitivity improvement has been limited by different types of noise. To address this issue, the sources and magnitudes of noises are comprehensively analyzed and a suppression method is proposed for the most critical noise source, optical non-orthogonality. The optical non-orthogonality leads to critical transverse pumping effect, thus transverse light shift, and transverse effective magnetic noise. A direct correlation between the optical non-orthogonality and the electronic spin transverse relaxation rate is found, and a method for suppression of the optical non-orthogonality is proposed accordingly. Finally, the optical non-orthogonal noise is suppressed by 3.1 dB. Besides, an increase of 5.2 dB in the scale factor is achieved. With the combined effect of noise suppression and scale factor enhancement, the resulting inertial rotation sensitivity of 2.4×10-8rad/s/Hz1/2in the frequency range from 1 to 3 Hz is among the most sensitive comagnetometers, which opens up promising opportunities for new physics measurements, such as the search for ultralight dark matter and the fifth force.

IEEE Transactions on Instrumentation and Measurement•Jan 1, 2024•16 citations

A Highly Sensitive In Situ Magnetic Field Fluctuation Measurement Method Based on Nuclear-Spin Depolarization in an Atomic Comagnetometer

Haoying Pang, Wenfeng Fan, Jiong Huang +3 more

In this article, a highly sensitivein situmagnetic field fluctuation measurement method is proposed based on nuclear-spin depolarization in a spin-exchange relaxation-free (SERF) atomic comagnetometer (ACM). The steady-state model of the hybrid atomic spin ensemble is systematically studied. According to the theoretical model, two different states of nuclear-spin polarization and unpolarization lead to different sensitivities of the system to rotation and magnetic fields. The gradient magnetic field (GMF) is employed to change the state of nuclear-spin polarization of the noble gas, transforming the ACM into an atomic magnetometer (AM). The polarization and relaxation rates of the electron spin and nuclear spin under the two measurement modes are measured and compared by the magnetic resonance method and transient response method. At the same time, the performances in the ACM and AM are tested. Detailed experiments verify that the AM can achieve sensitivity for the magnetic field measurement with an average value of$53.6~\mathbf {fT/Hz^{1/2}}$in the frequency range of$10\sim 30$Hz. The Allan variance method is adopted to evaluate the$x$- and$y$-axis magnetic field stabilities of the ACM, and the magnitudes are 61.6 and 55.9 fT at 100 s, contributing about 4.9$\times 10\mathbf {^{-3}}\,\,\mathbf {^{\circ }/h}$and 2.6$\times 10\mathbf {^{-4}}\,\,\mathbf {^{\circ }/h}$to the long-term stability of the ACM. This method can not only realize the high-sensitivityin situmeasurement of the close-to-zero magnetic field and its fluctuation but also realize the switching of the two measurement modes of rotation and magnetic field measurements, which is essential for the evaluation of magnetic field error.

IEEE Transactions on Instrumentation and Measurement•Jan 1, 2022•19 citations
Ultrasensitive atomic comagnetometers (ACMs) are invaluable tools for both inertial measurement and fundamental physics research. However, the misalignment between the pump light and the main magnetic field affects the polarization characteristics of nuclear spins of the noble gas atoms, making it a significant source of noise. In this article, an atomic magnetometer response model with the optical-magnetic misalignment error is established, and the mechanism of the influence of optical-magnetic misalignment on nuclear spin polarization is analyzed. An in situ evaluation method and a suppression method of optical-magnetic misalignment error are proposed, and their effectiveness is verified through experiments with varying pump light incidence directions. The experimental results indicate that after optical-magnetic alignment using the proposed method, the spin polarization of the coupled atomic ensemble is enhanced by 20.7%, and the longitudinal relaxation rate of the nuclear spin is reduced by 6.9%. Additionally, the amplitude-frequency response (AFR) of the x-axis magnetic field is reduced by 33.2% at 1 Hz and by 53.1% at frequencies below 0.002 Hz. This indicates an improvement in the transverse magnetic field error suppression capability of the ACMs.
The misalignment error of the pumping laser in the atomic comagnetometer (ACM) dramatically diminishes the efficiency of the optical pumping process (characterized by the polarization of the hybrid atomic spin ensembles containing electron spins and nuclear spins) and deteriorates the performance of the ACM (characterized by the Allan standard deviation). In this work, a steady-state response model considering the misalignment error of the pumping laser is established and an in-situ evaluation method for this error is proposed. Based on the evaluation method, the influence of this misalignment error on the pumping efficiency and the performance of the ACM is quantitatively analyzed. Furthermore, a pumping laser alignment method based on the second harmonic of a single-beam magnetometer is then proposed, whose effectiveness is verified by experiments. The experimental results show that compared to the original ACM with the severely misaligned pumping laser, the polarization of the hybrid atomic spin ensembles of the ACM with the pumping laser aligned by the proposed method is increased by about 19%, and the corresponding Allan variance at 100s is reduced by about 40%.
The ultra-sensitive atomic co-magnetometer based on the spin-exchange relaxation-free (SERF) regime is a valuable tool for inertial measurements and fundamental physics research. However, the optical magnetic misalignment effect is a significant source of error in SERF co-magnetometers, limiting their magnetic field suppression ability and long-term stability. This paper establishes a response model of angular velocity and magnetic field for the SERF co-magnetometer. The impact of optical magnetic misalignment on the scale factor, magnetic field amplitude-frequency response, and angular velocity errors caused by magnetic noise is systematically investigated. The results indicate that the scale factor and magnetic field suppression ability decrease as the optical magnetic misalignment angle increases, while the angular velocity errors caused by magnetic noise increase as the misalignment angle increases. Finally, experimental results demonstrate that the optical-magnetic misalignment effect significantly compromises the long-term stability of SERF co-magnetometers, underscoring its substantial influence on the overall performance. This work contributes to understanding the mechanism of optical magnetic misalignment effects on the SERF co-magnetometer and enhances its performance.
In atomic spin sensors based on optical pumping, pump beam instabilities can drive atomic spin polarization fluctuations, referred to here as pump-induced spin polarization noise, which may limit sensitivity and long-term stability. Because the local pump field inside the cell can differ from that inferred from external optical diagnostics, it remains difficult to directly quantify the actual in situ spin polarization noise and to evaluate and suppress its contribution to the sensor noise floor. Here, we propose an in situ decoupling method based on spin dynamics, in which a large longitudinal detuning field suppresses magnetic field and rotation responses, while a transverse projection field converts pump-induced fluctuations in longitudinal spin polarization into a measurable transverse spin signal. Demonstrated in a K-Rb-21Ne spin exchange relaxation free (SERF) comagnetometer, the proposed method suppresses the magnetic-field response by approximately 180-fold and enhances the pump-power-noise response by approximately 380-fold, thereby enabling effective separation and evaluation of pump-induced spin polarization noise. The method employs the atomic ensemble as an in situ probe of the spin dynamic response to the local pump optical field. It enables quantitative identification of pump fluctuation associated noise and direct evaluation of optical field stability under actual operating conditions, thereby providing an experimental basis for optical field stabilization and noise suppression assessment in SERF comagnetometers and related alkali atomic spin sensors.
The atomic comagnetometers (ACMs) based on the spin-exchange relaxation-free (SERF) regime exhibit extremely high sensitivity in angular velocity measurements, positioning them as leading candidates for next-generation precision inertial sensing. However, magnetic noise remains a significant factor that contributes significantly to long-term bias drift. Here, a comprehensive model in full-frequency band of the angular velocity measurement error induced by magnetic noise in ACMs is established. Based on the proposed model, what we believe to be a new method is proposed to reduce magnetic noise error by suppressing the magnetic field response in the mid-frequency range. After optimizing the temperature of the vapor cell to minimize the magnetic field response in the mid-frequency range, the angular velocity measurement error caused by magnetic noise was reduced by 20.4%, and the bias drift was improved by 34.8%. The theories and methods proposed in this study innovatively highlight the critical role of mid-frequency magnetic field responses in suppressing magnetic noise errors, and provide important guidance for improving bias drift in SERF ACMs.
Ultrasensitive atomic comagnetometers have proven to be valuable tools for precise measurement and search for new physics. Besides, comagnetometers have potential for inertial navigation and quantum information. Despite their great potential, sensitivity improvement has been limited by different types of noise. To address this issue, the sources and magnitudes of noises are comprehensively analyzed and a suppression method is proposed for the most critical noise source, optical non-orthogonality. The optical non-orthogonality leads to critical transverse pumping effect, thus transverse light shift, and transverse effective magnetic noise. A direct correlation between the optical non-orthogonality and the electronic spin transverse relaxation rate is found, and a method for suppression of the optical non-orthogonality is proposed accordingly. Finally, the optical non-orthogonal noise is suppressed by 3.1 dB. Besides, an increase of 5.2 dB in the scale factor is achieved. With the combined effect of noise suppression and scale factor enhancement, the resulting inertial rotation sensitivity of 2.4×10-8rad/s/Hz1/2in the frequency range from 1 to 3 Hz is among the most sensitive comagnetometers, which opens up promising opportunities for new physics measurements, such as the search for ultralight dark matter and the fifth force.
In this article, a highly sensitivein situmagnetic field fluctuation measurement method is proposed based on nuclear-spin depolarization in a spin-exchange relaxation-free (SERF) atomic comagnetometer (ACM). The steady-state model of the hybrid atomic spin ensemble is systematically studied. According to the theoretical model, two different states of nuclear-spin polarization and unpolarization lead to different sensitivities of the system to rotation and magnetic fields. The gradient magnetic field (GMF) is employed to change the state of nuclear-spin polarization of the noble gas, transforming the ACM into an atomic magnetometer (AM). The polarization and relaxation rates of the electron spin and nuclear spin under the two measurement modes are measured and compared by the magnetic resonance method and transient response method. At the same time, the performances in the ACM and AM are tested. Detailed experiments verify that the AM can achieve sensitivity for the magnetic field measurement with an average value of53.6 fT/Hz1/253.6~\mathbf {fT/Hz^{1/2}}53.6 fT/Hz1/2in the frequency range of10∼3010\sim 3010∼30Hz. The Allan variance method is adopted to evaluate thexxx- andyyy-axis magnetic field stabilities of the ACM, and the magnitudes are 61.6 and 55.9 fT at 100 s, contributing about 4.9×10−3  ∘/h\times 10\mathbf {^{-3}}\,\,\mathbf {^{\circ }/h}×10−3∘/hand 2.6×10−4  ∘/h\times 10\mathbf {^{-4}}\,\,\mathbf {^{\circ }/h}×10−4∘/hto the long-term stability of the ACM. This method can not only realize the high-sensitivityin situmeasurement of the close-to-zero magnetic field and its fluctuation but also realize the switching of the two measurement modes of rotation and magnetic field measurements, which is essential for the evaluation of magnetic field error.